Normalized to: Schreiber, J.
[1]
oai:arXiv.org:1005.1487 [pdf] - 1026738
The Photodetector Array Camera and Spectrometer (PACS) on the Herschel
Space Observatory
Poglitsch, A.;
Waelkens, C.;
Geis, N.;
Feuchtgruber, H.;
Vandenbussche, B.;
Rodriguez, L.;
Krause, O.;
Renotte, E.;
van Hoof, C.;
Saraceno, P.;
Cepa, J.;
Kerschbaum, F.;
Agnese, P.;
Ali, B.;
Altieri, B.;
Andreani, P.;
Augueres, J. -L.;
Balog, Z.;
Barl, L.;
Bauer, O. H.;
Belbachir, N.;
Benedettini, M.;
Billot, N.;
Boulade, O.;
Bischof, H.;
Blommaert, J.;
Callut, E.;
Cara, C.;
Cerulli, R.;
Cesarsky, D.;
Contursi, A.;
Creten, Y.;
De Meester, W.;
Doublier, V.;
Doumayrou, E.;
Duband, L.;
Exter, K.;
Genzel, R.;
Gillis, J. -M.;
Grözinger, U.;
Henning, T.;
Herreros, J.;
Huygen, R.;
Inguscio, M.;
Jakob, G.;
Jamar, C.;
Jean, C.;
de Jong, J.;
Katterloher, R.;
Kiss, C.;
Klaas, U.;
Lemke, D.;
Lutz, D.;
Madden, S.;
Marquet, B.;
Martignac, J.;
Mazy, A.;
Merken, P.;
Montfort, F.;
Morbidelli, L.;
Müller, T.;
Nielbock, M.;
Okumura, K.;
Orfei, R.;
Ottensamer, R.;
Pezzuto, S.;
Popesso, P.;
Putzeys, J.;
Regibo, S.;
Reveret, V.;
Royer, P.;
Sauvage, M.;
Schreiber, J.;
Stegmaier, J.;
Schmitt, D.;
Schubert, J.;
Sturm, E.;
Thiel, M.;
Tofani, G.;
Vavrek, R.;
Wetzstein, M.;
Wieprecht, E.;
Wiezorrek, E.
Submitted: 2010-05-10, last modified: 2010-05-20
The Photodetector Array Camera and Spectrometer (PACS) is one of the three
science instruments on ESA's far infrared and submillimetre observatory. It
employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25
pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64
pixels, respectively, to perform integral-field spectroscopy and imaging
photometry in the 60-210\mu\ m wavelength regime. In photometry mode, it
simultaneously images two bands, 60-85\mu\ m or 85-125\mu\m and 125-210\mu\ m,
over a field of view of ~1.75'x3.5', with close to Nyquist beam sampling in
each band. In spectroscopy mode, it images a field of 47"x47", resolved into
5x5 pixels, with an instantaneous spectral coverage of ~1500km/s and a spectral
resolution of ~175km/s. We summarise the design of the instrument, describe
observing modes, calibration, and data analysis methods, and present our
current assessment of the in-orbit performance of the instrument based on the
Performance Verification tests. PACS is fully operational, and the achieved
performance is close to or better than the pre-launch predictions.
[2]
oai:arXiv.org:1005.2290 [pdf] - 1032443
Tracing the sites of obscured star formation in the Antennae galaxies
with Herschel-PACS
Submitted: 2010-05-13
FIR imaging of interacting galaxies allows locating even hidden sites of star
formation and measuring of the relative strength of nuclear and extra-nuclear
star formation. We want to resolve the star-forming sites in the nearby system
of the Antennae. Thanks to the unprecedented sharpness and depth of the PACS
camera onboard ESA's Herschel Space Observatory, it is possible for the first
time to achieve a complete assessment of individual star-forming knots in the
FIR with scan maps at 70, 100, and 160 um. We used clump extraction photometry
and SED diagnostics to derive the properties related to star-forming activity.
The PACS 70, 100, and 160 um maps trace the knotty structure of the most recent
star formation along an arc between the two nuclei in the overlap area. The
resolution of the starburst knots and additional multi-wavelength data allow
their individual star formation history and state to be analysed. In
particular, the brightest knot in the mid-infrared (K1), east of the southern
nucleus, exhibits the highest activity by far in terms of dust heating and star
formation rate, efficiency, and density. With only 2 kpc in diameter, this area
has a 10-1000 um luminosity, which is as high as that of our Milky Way. It
shows the highest deficiency in radio emission in the radio-to-FIR luminosity
ratio and a lack of X-ray emission, classifying it as a very young complex. The
brightest 100 and 160 um emission region (K2), which is close to the collision
front and consists of 3 knots, also shows a high star formation density and
efficiency and lack of X-ray emission in its most obscured part, but an excess
in the radio-to-FIR luminosity ratio. This suggests a young stage, too, but
different conditions in its interstellar medium. Our results provide important
checkpoints for numerical simulations of interacting galaxies when modelling
the star formation and stellar feedback.
[3]
oai:arXiv.org:astro-ph/0701297 [pdf] - 88426
The SINFONI pipeline
Modigliani, Andrea;
Hummel, Wolfgang;
Abuter, Roberto;
Amico, Paola;
Ballester, Pascal;
Davies, Richard;
Dumas, Christophe;
Horrobin, Mattew;
Neeser, Mark;
Kissler-Patig, Markus;
Peron, Michele;
Rehunanen, Juha;
Schreiber, Juergen;
Szeifert, Thomas
Submitted: 2007-01-10, last modified: 2007-02-05
The SINFONI data reduction pipeline, as part of the ESO-VLT Data Flow System,
provides recipes for Paranal Science Operations, and for Data Flow Operations
at Garching headquarters. At Paranal, it is used for the quick-look data
evaluation. For Data Flow Operations, it fulfills several functions: creating
master calibrations; monitoring instrument health and data quality; and
reducing science data for delivery to service mode users. The pipeline is
available to the science community for reprocessing data with personalised
reduction strategies and parameters. The pipeline recipes can be executed
either with EsoRex at the command line level or through the Gasgano graphical
user interface. The recipes are implemented with the ESO Common Pipeline
Library (CPL).
SINFONI is the Spectrograph for INtegral Field Observations in the Near
Infrared (1.1-2.45 um) at the ESO-VLT. SINFONI was developed and build by ESO
and MPE in collaboration with NOVA. It consists of the SPIFFI integral field
spectrograph and an adaptive optics module which allows diffraction limited and
seeing limited observations. The image slicer of SPIFFI chops the SINFONI field
of view on the sky in 32 slices which are re-arranged to a pseudo slit. The
latter is dispersed by one of the four possible gratings (J, H, K, H+K). The
detector thus sees a spatial dimension (along the pseudo-slit) and a spectral
dimension.
We describe in this paper the main data reduction procedures of the SINFONI
pipeline, which is based on SPRED - the SPIFFI data reduction software
developed by MPE, and the most recent developments after more than a year of
SINFONI operations.
[4]
oai:arXiv.org:astro-ph/0306191 [pdf] - 57272
SINFONI - Integral Field Spectroscopy at 50 milli-arcsecond resolution
with the ESO VLT
Eisenhauer, F.;
Bonnet, H.;
Abuter, R.;
Bickert, K.;
Bianca-Marchet, F.;
Brynnel, J.;
Conzelmann, R.;
Delabre, B.;
Donaldson, R.;
Farinato, J.;
Fedrigo, E.;
Finger, G.;
Genzel, R.;
Hubin, N.;
Iserlohe, C.;
Kasper, M.;
Kissler-Patig, M.;
Monnet, G.;
Roehrle, C.;
Schreiber, J.;
Stroebele, S.;
Tecza, M.;
Thatte, N.;
Weisz, H.
Submitted: 2003-06-10, last modified: 2003-06-11
SINFONI is an adaptive optics assisted near-infrared integral field
spectrometer for the ESO VLT. The Adaptive Optics Module (built by the ESO
Adaptive Optics Group) is a 60-elements curvature-sensor based system, designed
for operations with natural or sodium laser guide stars. The near-infrared
integral field spectrometer SPIFFI (built by the Infrared Group of MPE)
provides simultaneous spectroscopy of 32 x 32 spatial pixels, and a spectral
resolving power of up to 3300. The adaptive optics module is in the phase of
integration; the spectrometer is presently tested in the laboratory. We provide
an overview of the project, with particular emphasis on the problems
encountered in designing and building an adaptive optics assisted spectrometer.
[5]
oai:arXiv.org:astro-ph/0008398 [pdf] - 1232542
A new era of spectroscopy: SINFONI, NIR integral field spectroscopy at
the diffraction limit of an 8m telescope
Submitted: 2000-08-25
SINFONI, the SINgle Faint Object Near-infrared Investigation, is an
instrument for the Very Large Telescope (VLT), which will start its operation
mid 2002 and allow for the first time near infrared (NIR) integral field
spectroscopy at the diffraction limit of an 8-m telescope. SINFONI is the
combination of two state-of-the art instruments, the integral field
spectrometer SPIFFI, built by the Max-Planck-Institut fuer extraterrestrische
Physik (MPE), and the adaptive optics (AO) system MACAO, built by the European
Southern Observatory (ESO). It will allow a unique type of observations by
delivering simultaneously high spatial resolution (pixel sizes 0.025arcsec to
0.25arcsec) and a moderate spectral resolution (R~2000 to R~4500), where the
higher spectral resolution mode will allow for software OH suppression. This
opens new prospects for astronomy.
[6]
oai:arXiv.org:astro-ph/0008296 [pdf] - 1232536
Imaging the Universe in 3D with the VLT: The Next Generation Field
Spectrometer SPIFFI
Submitted: 2000-08-18
We present SPIFFI, the integral field spectrometer for the VLT. This
instrument allows simultaneous observation of infrared spectra in more than
1000 image points of a two dimensional field. With its set of four gratings and
a pixel scale that can be varied by a factor of ten, SPIFFI provides high
flexibility, and at the same time offers the unique possibility of diffraction
limited imaging spectroscopy at an 8m-class telescope, when fed by the adaptive
optics system MACAO. We outline the scientific drivers for building such an
instrument, the concept of image slicing, the optical design, and the
implementation of SPIFFI.