Normalized to: Scholz, B.
[1]
oai:arXiv.org:1608.00957 [pdf] - 1511854
Measurement of the ionization produced by sub-keV silicon nuclear
recoils in a CCD dark matter detector
Chavarria, A. E.;
Collar, J. I.;
Peña, J. R.;
Privitera, P.;
Robinson, A. E.;
Scholz, B.;
Sengul, C.;
Zhou, J.;
Estrada, J.;
Izraelevitch, F.;
Tiffenberg, J.;
Neto, J. R. T. de Mello;
Machado, D. Torres
Submitted: 2016-08-02, last modified: 2016-11-09
We report a measurement of the ionization efficiency of silicon nuclei
recoiling with sub-keV kinetic energy in the bulk silicon of a charge-coupled
device (CCD). Nuclear recoils are produced by low-energy neutrons ($<$24 keV)
from a $^{124}$Sb-$^{9}$Be photoneutron source, and their ionization signal is
measured down to 60 eV electron equivalent. This energy range, previously
unexplored, is relevant for the detection of low-mass dark matter particles.
The measured efficiency is found to deviate from the extrapolation to low
energies of the Lindhard model. This measurement also demonstrates the
sensitivity to nuclear recoils of CCDs employed by DAMIC, a dark matter direct
detection experiment located in the SNOLAB underground laboratory.
[2]
oai:arXiv.org:1608.03588 [pdf] - 1531249
Measurement of the low-energy quenching factor in germanium using an
$^{88}$Y/Be photoneutron source
Submitted: 2016-08-11
We employ an $^{88}$Y/Be photoneutron source to derive the quenching factor
for neutron-induced nuclear recoils in germanium, probing recoil energies from
a few hundred eV$_{nr}$ to 8.5keV$_{nr}$. A comprehensive Monte Carlo
simulation of our setup is compared to experimental data employing a Lindhard
model with a free electronic energy loss $k$ and an adiabatic correction for
sub-keV$_{nr}$ nuclear recoils. The best fit $k=0.179\pm 0.001$ obtained using
a Monte Carlo Markov Chain (MCMC) ensemble sampler is in good agreement with
previous measurements, confirming the adequacy of the Lindhard model to
describe the stopping of few-keV ions in germanium crystals at a temperature of
$\sim$77 K. This value of $k$ corresponds to a quenching factor of 13.7 % to
25.3 % for nuclear recoil energies between 0.3 keV$_{nr}$ and 8.5 keV$_{nr}$,
respectively.
[3]
oai:arXiv.org:1407.7524 [pdf] - 903589
Coherent neutrino-nucleus scattering detection with a CsI[Na]
scintillator at the SNS spallation source
Submitted: 2014-07-28, last modified: 2014-08-20
We study the possibility of using CsI[Na] scintillators as an advantageous
target for the detection of coherent elastic neutrino-nucleus scattering
(CENNS), using the neutrino emissions from the SNS spallation source at Oak
Ridge National Laboratory. The response of this material to low-energy nuclear
recoils like those expected from this process is characterized. Backgrounds are
studied using a 2 kg low-background prototype crystal in a dedicated radiation
shield. The conclusion is that a planned 14 kg detector should measure
approximately 550 CENNS events per year above a demonstrated $\sim7$ keVnr
low-energy threshold, with a signal-to-background ratio sufficient for a first
measurement of the CENNS cross-section. The cross-section for the
$^{208}$Pb($\nu_{e},e^{-}$)$^{208}$Bi reaction, of interest for future
supernova neutrino detection, can be simultaneously obtained.