Schlerman, E.
Normalized to: Schlerman, E.
2 article(s) in total. 13 co-authors, from 1 to 2 common article(s). Median position in authors list is 6,5.
[1]
oai:arXiv.org:1707.00204 [pdf] - 1585390
Timing calibration of the APOLLO experiment
Submitted: 2017-07-01
The Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) began
millimeter-precision ranging to the Moon in 2006. Until now, a comprehensive
validation of APOLLO system range accuracy has not been possible because of
centimeter-scale deficiencies in computational models of the Earth-Moon range,
and because APOLLO lacked an internal timing calibration system. Here, we
report on the development of a system that enables in-situ calibration of the
timing response of the APOLLO apparatus, simultaneous with lunar range
measurements. The system was installed in August 2016. Preliminary results show
that the APOLLO system can provide lunar range measurements with millimeter
accuracy.
[2]
oai:arXiv.org:1706.09550 [pdf] - 1598075
An absolute calibration system for millimeter-accuracy APOLLO
measurements
Adelberger, E. G.;
Battat, J. B. R.;
Birkmeier, K. J.;
Colmenares, N. R.;
Davis, R.;
Hoyle, C. D.;
Huang, L. R.;
McMillan, R. J.;
Murphy, T. W.;
Schlerman, E.;
Skrobol, C.;
Stubbs, C. W.;
Zach, A.
Submitted: 2017-06-28
Lunar laser ranging provides a number of leading experimental tests of
gravitation -- important in our quest to unify General Relativity and the
Standard Model of physics. The Apache Point Observatory Lunar Laser-ranging
Operation (APOLLO) has for years achieved median range precision at the ~2 mm
level. Yet residuals in model-measurement comparisons are an order-of-magnitude
larger, raising the question of whether the ranging data are not nearly as
accurate as they are precise, or if the models are incomplete or
ill-conditioned. This paper describes a new absolute calibration system (ACS)
intended both as a tool for exposing and eliminating sources of systematic
error, and also as a means to directly calibrate ranging data in-situ. The
system consists of a high-repetition-rate (80 MHz) laser emitting short (< 10
ps) pulses that are locked to a cesium clock. In essence, the ACS delivers
photons to the APOLLO detector at exquisitely well-defined time intervals as a
"truth" input against which APOLLO's timing performance may be judged and
corrected. Preliminary analysis indicates no inaccuracies in APOLLO data beyond
the ~3 mm level, suggesting that historical APOLLO data are of high quality and
motivating continued work on model capabilities. The ACS provides the means to
deliver APOLLO data both accurate and precise below the 2 mm level.