sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Schattenburg, Mark

Normalized to: Schattenburg, M.

12 article(s) in total. 51 co-authors, from 1 to 9 common article(s). Median position in authors list is 7,0.

[1]  oai:arXiv.org:2004.13001  [pdf] - 2119963
Optical design of diffraction-limited X-ray telescopes
Comments: 20 pages, 11 figures, accepted for publication in Applied Optics
Submitted: 2020-04-24
Astronomical imaging with micro-arcsecond ($\mu$as) angular resolution could enable breakthrough scientific discoveries. Previously-proposed $\mu$as X-ray imager designs have been interferometers with limited effective collecting area. Here we describe X-ray telescopes achieving diffraction-limited performance over a wide energy band with large effective area, employing a nested-shell architecture with grazing-incidence mirrors, while matching the optical path lengths between all shells. We present two compact nested-shell Wolter Type 2 grazing-incidence telescope designs for diffraction-limited X-ray imaging: a micro-arcsecond telescope design with 14 $\mu$as angular resolution and 2.9 m$^2$ of effective area at 5 keV photon energy ($\lambda$=0.25 nm), and a smaller milli-arcsecond telescope design with 525 $\mu$as resolution and 645 cm$^2$ effective area at 1 keV ($\lambda$=1.24 nm). We describe how to match the optical path lengths between all shells in a compact mirror assembly, and investigate chromatic and off-axis aberrations. Chromatic aberration results from total external reflection off of mirror surfaces, and we greatly mitigate its effects by slightly adjusting the path lengths in each mirror shell. The mirror surface height error and alignment requirements for diffraction-limited performance are challenging but arguably achieveable in the coming decades. Since the focal ratio for a diffraction-limited X-ray telescope is extremely large ($f/D$~10$^5$), the only important off-axis aberration is curvature of field, so a 1 arcsecond field of view is feasible with a flat detector. The detector must fly in formation with the mirror assembly, but relative positioning tolerances are on the order of 1 m over a distance of some tens to hundreds of kilometers. While there are many challenges to achieving diffraction-limited X-ray imaging, we did not find any fundamental barriers.
[2]  oai:arXiv.org:1812.08229  [pdf] - 1834189
Demonstration of resolving power $\lambda/\Delta\lambda > 10,000$ for a space-based x-ray transmission grating spectrometer
Comments:
Submitted: 2018-12-19
We present measurements of the resolving power of a soft x-ray spectrometer consisting of 200 nm-period lightweight, alignment-insensitive critical-angle transmission (CAT) gratings and a lightweight slumped-glass Wolter-I focusing mirror pair. We measure and model contributions from source, mirrors, detector pixel size, and grating period variation to the natural line width spectrum of the Al and Mg K$_{\alpha_1 \alpha_2}$ doublets. Measuring up to 18$^{\rm th}$ diffraction order at characteristic Al-K wavelengths we consistently obtain small broadening due to gratings corresponding to a minimum effective grating resolving power $R_g > 10,000$ with 90\% confidence. Upper limits are often compatible with $R_g = \infty$. Independent fitting of different diffraction orders, as well as ensemble fitting of multiple orders at multiple wavelengths, gives compatible results. Our data leads to uncertainties for the Al-K$_{\alpha}$ doublet line width and line separation parameters 2-3 times smaller than values found in the literature. Data from three different gratings are mutually compatible. This demonstrates that CAT gratings perform in excess of the requirements for the Arcus Explorer mission and are suitable for next-generation space-based x-ray spectrometer designs with resolving power 5-10 times higher than the transmission grating spectrometer on the Chandra X-ray Observatory.
[3]  oai:arXiv.org:1607.04517  [pdf] - 1521256
Critical-angle x-ray transmission grating spectrometer with extended bandpass and resolving power > 10,000
Comments: submitted to Proc. SPIE 9905
Submitted: 2016-07-15
Several high priority subjects in astrophysics can be addressed by a state-of-the-art soft x-ray grating spectrometer (XGS). An Explorer-scale, large-area (> 1,000 cm2), high resolving power (R > 3,000) XGS is highly feasible based on Critical-Angle Transmission (CAT) gratings, even for telescopes with angular resolution of 5-10 arcsec. Significantly higher performance can be provided by a CAT XGS on an X-ray-Surveyor-type mission. CAT gratings combine the advantages of blazed reflection gratings (high efficiency, use of higher diffraction orders) with those of transmission gratings (low mass, relaxed alignment and temperature requirements, transparent at high energies) with minimal mission resource demands. They are high-efficiency blazed transmission gratings that consist of freestanding, ultra-high aspect-ratio grating bars made from SOI wafers using anisotropic dry and wet etch techniques. Blazing is achieved through reflection off grating bar sidewalls. Silicon is well matched to the soft x-ray band, and existing silicon CAT gratings exceed 30% absolute diffraction efficiency, with clear paths for improvement. CAT gratings coated with heavier elements allow extension of the CAT grating principle to higher energies and larger angles, enabling higher resolving power at shorter wavelengths. We show x-ray data from CAT gratings coated with platinum using atomic layer deposition, and demonstrate blazing to higher energies and much larger blaze angles than possible with silicon. We measure resolving power of a CAT XGS consisting of a Wolter-I focusing mirror pair from GSFC and CAT gratings, performed at the MSFC SLF. Measurement of the Al Ka doublet in 18th order shows resolving power > 10,000, based on preliminary analysis. This demonstrates that currently fabricated CAT gratings are compatible with the most advanced XGS designs for future soft x-ray spectroscopy missions.
[4]  oai:arXiv.org:0904.3382  [pdf] - 23561
Distribution and Structure of Matter in and around Galaxies
Comments: A White Paper Submitted to the Astro2010 Decadal Survey
Submitted: 2009-04-22
Understanding the origins and distribution of matter in the Universe is one of the most important quests in physics and astronomy. Themes range from astro-particle physics to chemical evolution in the Galaxy to cosmic nucleosynthesis and chemistry in an anticipation of a full account of matter in the Universe. Studies of chemical evolution in the early Universe will answer questions about when and where the majority of metals were formed, how they spread and why they appar today as they are. The evolution of matter in our Universe cannot be characterized as a simple path of development. In fact the state of matter today tells us that mass and matter is under constant reformation through on-going star formation, nucleosynthesis and mass loss on stellar and galactic scales. X-ray absorption studies have evolved in recent years into powerful means to probe the various phases of interstellar and intergalactic media. Future observatories such as IXO and Gen-X will provide vast new opportunities to study structure and distribution of matter with high resolution X-ray spectra. Specifically the capabilities of the soft energy gratings with a resolution of R=3000 onboard IXO will provide ground breaking determinations of element abundance, ionization structure, and dispersion velocities of the interstellar and intergalactic media of our Galaxy and the Local Group
[5]  oai:arXiv.org:0904.3385  [pdf] - 23562
Structure and Evolution of Pre-Main Sequence Stars
Comments: A White Paper Submitted to the Astro2010 Decadal Survey
Submitted: 2009-04-22
Low-mass pre-main sequence (PMS) stars are strong and variable X-ray emitters, as has been well established by EINSTEIN and ROSAT observatories. It was originally believed that this emission was of thermal nature and primarily originated from coronal activity (magnetically confined loops, in analogy with Solar activity) on contracting young stars. Broadband spectral analysis showed that the emission was not isothermal and that elemental abundances were non-Solar. The resolving power of the Chandra and XMM X-ray gratings spectrometers have provided the first, tantalizing details concerning the physical conditions such as temperatures, densities, and abundances that characterize the X-ray emitting regions of young star. These existing high resolution spectrometers, however, simply do not have the effective area to measure diagnostic lines for a large number of PMS stars over required to answer global questions such as: how does magnetic activity in PMS stars differ from that of main sequence stars, how do they evolve, what determines the population structure and activity in stellar clusters, and how does the activity influence the evolution of protostellar disks. Highly resolved (R>3000) X-ray spectroscopy at orders of magnitude greater efficiency than currently available will provide major advances in answering these questions. This requires the ability to resolve the key diagnostic emission lines with a precision of better than 100 km/s.
[6]  oai:arXiv.org:astro-ph/0507035  [pdf] - 74204
The Chandra High Energy Transmission Grating: Design, Fabrication, Ground Calibration and Five Years in Flight
Comments: 34 pages (including 30 figures), accepted for publication in PASP
Submitted: 2005-07-01
Details of the design, fabrication, ground and flight calibration of the High Energy Transmission Grating, HETG, on the Chandra X-ray Observatory are presented after five years of flight experience. Specifics include the theory of phased transmission gratings as applied to the HETG, the Rowland design of the spectrometer, details of the grating fabrication techniques, and the results of ground testing and calibration of the HETG. For nearly six years the HETG has operated essentially as designed, although it has presented some subtle flight calibration effects.
[7]  oai:arXiv.org:astro-ph/0312509  [pdf] - 61722
Chandra High-Resolution X-Ray Spectrum of Supernova Remnant 1E0102.2-7219
Comments: 47 pages, 14 figures, accepted for publication in ApJ
Submitted: 2003-12-18
Chandra High Energy Transmission Grating Spectrometer observations of the supernova remnant 1E0102.2-7219 in the Small Magellanic Cloud reveal a spectrum dominated by X-ray emission lines from hydrogen-like and helium-like ions of oxygen, neon, magnesium and silicon, with little iron. The dispersed spectrum shows a series of monochromatic images of the source in the light of individual spectral lines. Detailed examination of these dispersed images reveals Doppler shifts within the supernova remnant, indicating bulk matter velocities on the order of 1000 km/s. These bulk velocities suggest an expanding ring-like structure with additional substructure, inclined to the line of sight. A two-dimensional spatial/velocity map of the SNR shows a striking spatial separation of redshifted and blueshifted regions, and indicates a need for further investigation before an adequate 3D model can be found. The radii of the ring-like images of the dispersed spectrum vary with ionization stage, supporting an interpretation of progressive ionization due to passage of the reverse shock through the ejecta. Plasma diagnostics with individual emission lines of oxygen are consistent with an ionizing plasma in the low density limit, and provide temperature and ionization constraints on the plasma. Assuming a pure metal plasma, the mass of oxygen is estimated at ~6 solar masses, consistent with a massive progenitor.
[8]  oai:arXiv.org:astro-ph/0105060  [pdf] - 42289
High Resolution Spectroscopy of Two Oxygen-Rich SNRs with the Chandra HETG
Comments: 9 pages, 5 figures; To be published in Young Supernova Remnants: Eleventh Astrophysics Conference, College Park, Maryland, October 2000 (AIP Conference Proceedings), eds. S. S. Holt and U. Hwang (American Institute of Physics, Melville, NY)
Submitted: 2001-05-03
The HETG can be used to obtain spatially resolved spectra of moderately extended sources. We present preliminary results for two well studied, oxygen rich supernova remnants in the Magellanic clouds, E0102-72 and N132D. The dispersed spectrum of E0102-72 shows images of the remnant in the light of individual emission lines from H-like and He-like ions of O, Mg, Ne and He-like Si with no evidence of Fe. The diameters of the images for various ions, measured in the cross-dispersion direction, increase monotonically with the ionization age for the given ion. This shows in detail the progression of the reverse shock through the expanding stellar ejecta. We see clear evidence for asymmetric Doppler shifts across E0102-72 of ~2000 km/s. These can be modelled approximately by a partially-filled, expanding shell inclined to the line of sight. The dispersed spectrum of N132D is more affected by spatial/spectral overlap but also shows monochromatic images in several strong lines. Preliminary spectra have been extracted for several bright knots. Some regions of oxygen-rich material, presumably stellar ejecta, are clearly identified. Additional details on E0102-72 are presented by Flanagan et al. and Davis et al. in these proceedings, and further analysis is in progress.
[9]  oai:arXiv.org:astro-ph/0105058  [pdf] - 42287
Ionization and Velocity Structure in the Supernova Remnant E0102-72
Comments: 8 pages, 9 figures; To appear in the ASP Conference Series for X-ray Astronomy 2000, Palermo Italy, eds. Giacconi, Stella & Serio
Submitted: 2001-05-03
The High Energy Transmission Grating (HETG) Spectrometer aboard the Chandra X-Ray Observatory was used to observe E0102-72, a ~1000 year old, oxygen rich supernova in the Small Magellanic Cloud. The HETG disperses the image of the remnant into a spectrum of images in the light of individual X-ray emission lines. Doppler shifts in the strongest lines of oxygen and neon reveal bulk motions of up to 2000 km/sec with a complex morphology. Comparison of progressive ionization stages of magnesium, neon, oxygen and silicon provide new insights into the mechanism of the `reverse shock' that heats the stellar ejecta.
[10]  oai:arXiv.org:astro-ph/0105040  [pdf] - 42269
Ionization Structure and the Reverse Shock in E0102-72
Comments: 4 pages, 6 figures; To appear in "Young Supernova Remnants" (11th Annual Astrophysics Conference in Maryland), S. S. Holt & U. Hwang (eds), AIP, New York (2001)
Submitted: 2001-05-02, last modified: 2001-05-03
The young oxygen-rich supernova remnant E0102-72 in the Small Magellanic Cloud has been observed with the High Energy Transmission Grating Spectrometer of Chandra. The high resolution X-ray spectrum reveals images of the remnant in the light of individual emission lines of oxygen, neon, magnesium and silicon. The peak emission region for hydrogen-like ions lies at larger radial distance from the SNR center than the corresponding helium-like ions, suggesting passage of the ejecta through the "reverse shock". We examine models which test this interpretation, and we discuss the implications.
[11]  oai:arXiv.org:astro-ph/0105038  [pdf] - 42267
Spectral Line Imaging Observations of 1E0102.2-7219
Comments: To appear in "Young Supernova Remnants" (11th Annual Astrophysics Conference in Maryland), S. S. Holt & U. Hwang (eds), AIP, New York (2001)
Submitted: 2001-05-02
E0102-72 is the second brightest X-ray source in the Small Magellanic Cloud and the brightest supernova remnant in the SMC. We observed this SNR for ~140 ksec with the High Energy Transmission Gratings (HETG) aboard the Chandra X-ray Observatory. The small angular size and high surface brightness make this an excellent target for HETG and we resolve the remnant into individual lines. We observe fluxes from several lines which include O VIII Ly$\alpha$, Ly$\beta$, and O VII along with several lines from Ne X, Ne IX and Mg XII. These line ratios provide powerful constraints on the electron temperature and the ionization age of the remnant.
[12]  oai:arXiv.org:astro-ph/0006457  [pdf] - 36837
High Resolution X-Ray Spectra of Capella: Initial Results from the Chandra High Energy Transmission Grating Spectrometer
Comments: 9 pages, 3 figures (1 color) accepted for ApJL
Submitted: 2000-06-30
High resolution spectra of the active binary Capella (G8 III + G1 III) covering the energy range 0.4-8.0 keV (1.5-30 Angstroms) show a large number of emission lines, demonstrating the performance of the HETGS. A preliminary application of plasma diagnostics provides information on coronal temperatures and densities. Lines arising from different elements in a range of ionization states indicate that Capella has plasma with a broad range of temperatures, from log T = 6.3 to 7.2, generally consistent with recent results from observations with the Extreme Ultraviolet Explorer (EUVE) and the Advanced Satellite for Cosmology and Astrophysics (ASCA). The electron density is determined from He-like O VII lines, giving the value N_e=10^10 cm^-3 at T_e=2*10^6 K; He-like lines formed at higher temperatures give only upper limits to the electron density. The density and emission measure from O VII lines together indicate that the coronal loops are significantly smaller than the stellar radius.