Normalized to: Scarff, A.
[1]
oai:arXiv.org:2004.03463 [pdf] - 2077253
The COSINE-100 Liquid Scintillator Veto System
Adhikari, G.;
de Souza, E. Barbosa;
Carlin, N.;
Choi, J. J.;
Choi, S.;
Djamal, M.;
Ezeribe, A. C.;
Franca, L. E.;
Ha, C.;
Hahn, I. S.;
Jeon, E. J.;
Jo, J. H.;
Kang, W. G.;
Kauer, M.;
Kim, H.;
Kim, H. J.;
Kim, K. W.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H.;
Ko, Y. J.;
Lee, E. K.;
Lee, H. S.;
Lee, J.;
Lee, J. Y.;
Lee, M. H.;
Lee, S. H.;
Leonard, D. S.;
Manzato, B. B.;
Maruyama, R. H.;
Neal, R. J.;
Olsen, S. L.;
Park, B. J.;
Park, H. K.;
Park, H. S.;
Park, K. S.;
Pitta, R. L. C.;
Prihtiadi, H.;
Ra, S. J.;
Rott, C.;
Shin, K. A.;
Scarff, A.;
Spooner, N. J. C.;
Thompson, W. G.;
Yang, L.;
Yu, G. H.
Submitted: 2020-04-05
This paper describes the liquid scintillator veto system for the COSINE-100
dark matter experiment and its performance. The COSINE-100 detector consists of
8 NaI(Tl) crystals immersed in 2,200~L of linear alkylbenzene based liquid
scintillator. The liquid scintillator tags between 65 and 75\% of the internal
$^{40}$K background in the 2--6~keV energy region. We also describe the
background model for the liquid scintillator, which is primarily used to assess
its energy calibration and threshold.
[2]
oai:arXiv.org:1907.04963 [pdf] - 1996712
Comparison between DAMA/LIBRA and COSINE-100 in the light of Quenching
Factors
Ko, Y. J.;
Kim, K. W.;
Adhikari, G.;
Adhikari, P.;
de Souza, E. Barbosa;
Carlin, N.;
Choi, J. J.;
Choi, S.;
Djamal, M.;
Ezeribe, A. C.;
Ha, C.;
Hahn, I. S.;
Jeon, E. J.;
Jo, J. H.;
Kang, W. G.;
Kauer, M.;
Kim, G. S.;
Kim, H.;
Kim, H. J.;
Kim, N. Y.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H.;
Lee, E. K.;
Lee, H. S.;
Lee, J.;
Lee, J. Y.;
Lee, M. H.;
Lee, S. H.;
Leonard, D. S.;
Lynch, W. A.;
Manzato, B. B.;
Maruyama, R. H.;
Neal, R. J.;
Olsen, S. L.;
Park, B. J.;
Park, H. K.;
Park, H. S.;
Park, K. S.;
Pitta, R. L. C.;
Prihtiadi, H.;
Ra, S. J.;
Rott, C.;
Shin, K. A.;
Scarff, A.;
Spooner, N. J. C.;
Thompson, W. G.;
Yang, L.;
Yu, G. H.
Submitted: 2019-07-10, last modified: 2019-10-23
There is a long standing debate about whether or not the annual modulation
signal reported by the DAMA/LIBRA collaboration is induced by Weakly
Interacting Massive Particles~(WIMP) in the galaxy's dark matter halo
scattering from nuclides in their NaI(Tl) crystal target/detector. This is
because regions of WIMP-mass vs. WIMP-nucleon cross-section parameter space
that can accommodate the DAMA/LIBRA-phase1 modulation signal in the context of
the standard WIMP dark matter galactic halo and isospin-conserving~(canonical),
spin-independent~(SI) WIMP-nucleon interactions have been excluded by many of
other dark matter search experiments including COSINE-100, which uses the same
NaI(Tl) target/detector material.
Moreover, the recently released DAMA/LIBRA-phase2 results are inconsistent
with an interpretation as WIMP-nuclide scattering via the canonical SI
interaction and prefer, instead, isospin-violating or spin-dependent
interactions.
Dark matter interpretations of the DAMA/LIBRA signal are sensitive to the
NaI(Tl) scintillation efficiency for nuclear recoils, which is characterized by
so-called quenching factors~(QF), and the QF values used in previous studies
differ significantly from recently reported measurements, which may have led to
incorrect interpretations of the DAMA/LIBRA signal. In this article, the
compatibility of the DAMA/LIBRA and COSINE-100 results, in light of the new QF
measurements is examined for different possible types of WIMP-nucleon
interactions. The resulting allowed parameter space regions associated with the
DAMA/LIBRA signal are explicitly compared with 90\% confidence level upper
limits from the initial 59.5~day COSINE-100 exposure. With the newly measured
QF values, the allowed 3$\sigma$ regions from the DAMA/LIBRA data are still
generally excluded by the COSINE-100 data.
[3]
oai:arXiv.org:1909.13881 [pdf] - 1972740
Demonstration of ThGEM-Multiwire Hybrid Charge Readout for Directional
Dark Matter Searches
Submitted: 2019-09-30, last modified: 2019-10-02
Sensitivities of current directional dark matter search detectors using gas
time projection chambers are now constrained by target mass. A ton-scale gas
TPC detector will require large charge readout areas. We present a first
demonstration of a novel ThGEM-Multiwire hybrid charge readout technology which
combines the robust nature and high gas gain of Thick Gaseous Electron
Multipliers with lower capacitive noise of a one-plane multiwire charge readout
in SF$_6$ target gas. Measurements performed with this hybrid detector show an
ion drift velocity of $139~\pm~12~\text{ms}^{-1}$ in a reduced drift field
$\text{E/N}$ of $93~\text{Td}~(10^{-17}~\text{V cm}^{2})$ at a gas gain of
$2470\pm160$ in 20 Torr of pure SF$_\text{6}$ target gas.
[4]
oai:arXiv.org:1905.12861 [pdf] - 1975280
Study of cosmogenic radionuclides in the COSINE-100 NaI(Tl) detectors
de Souza, E. Barbosa;
Park, B. J.;
Adhikari, G.;
Adhikari, P.;
Carlin, N.;
Choi, J. J.;
Choi, S.;
Djamal, M.;
Ezeribe, A. C.;
Ha, C.;
Hahn, I. S.;
Jeon, E. J.;
Jo, J. H.;
Kang, W. G.;
Kauer, M.;
Kim, G. S.;
Kim, H.;
Kim, H. J.;
Kim, K. W.;
Kim, N. Y.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H.;
Ko, Y. J.;
Kudryavtsev, V. A.;
Lee, E. K.;
Lee, H. S.;
Lee, J.;
Lee, J. Y.;
Lee, M. H.;
Lee, S. H.;
Leonard, D. S.;
Lynch, W. A.;
Manzato, B. B.;
Maruyama, R. H.;
Neal, R. J.;
Olsen, S. L.;
Park, H. K.;
Park, H. S.;
Park, K. S.;
Pitta, R. L. C.;
Prihtiadi, H.;
Ra, S. J.;
Rott, C.;
Shin, K. A.;
Scarff, A.;
Spooner, N. J. C.;
Thompson, W. G.;
Yang, L.;
Yu, G. H.;
Collaboration, COSINE-100
Submitted: 2019-05-30, last modified: 2019-09-15
COSINE-100 is a direct detection dark matter search experiment that uses a
106 kg array of eight NaI(Tl) crystals that are kept underground at the
Yangyang Underground Laboratory to avoid cosmogenic activation of radioisotopes
by cosmic rays. Even though the cosmogenic activity is declining with time,
there are still significant background rates from the remnant nuclides. In this
paper, we report measurements of cosmogenic isotope contaminations with less
than one year half-lives that are based on extrapolations of the time dependent
activities of their characteristic energy peaks to activity rates at the time
the crystals were deployed underground. For longer-lived $^{109}$Cd
($T_{1/2}=1.6$ y) and $^{22}$Na ($T_{1/2}=2.6$ y), we investigate time
correlations of characteristic $\gamma$/X-ray peaks. The inferred sea-level
production rates are compared with caluclations based on the ACTIVIA and
MENDL-2 model calculations and experimental data. For $^{3}$H, which has a
long, 12.3 year half-life, we evaluated the activity levels from the exposure
times and determined a cosmogenic activation rate that is consistent with other
measurements.
[5]
oai:arXiv.org:1806.07043 [pdf] - 1944785
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in
Germanium with CDMSlite
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwal, S. R.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Banik, S.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-06-19, last modified: 2019-08-16
Future direct searches for low-mass dark matter particles with germanium
detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds
from radioactive isotopes activated by cosmogenic radiation inside the
germanium. There are limited experimental data available to constrain
production rates and a large spread of theoretical predictions. We examine the
calculation of expected production rates, and analyze data from the second run
of the CDMS low ionization threshold experiment (CDMSlite) to estimate the
rates for several isotopes. We model the measured CDMSlite spectrum and fit for
contributions from tritium and other isotopes. Using the knowledge of the
detector history, these results are converted to cosmogenic production rates at
sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H,
1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
[6]
oai:arXiv.org:1903.10098 [pdf] - 1922966
Search for a Dark Matter-Induced Annual Modulation Signal in NaI(Tl)
with the COSINE-100 Experiment
Collaboration, COSINE-100;
:;
Adhikari, G.;
Adhikari, P.;
de Souza, E. Barbosa;
Carlin, N.;
Choi, S.;
Djamal, M.;
Ezeribe, A. C.;
Ha, C.;
Hahn, I. S.;
Jeon, E. J.;
Jo, J. H.;
Joo, H. W.;
Kang, W. G.;
Kang, W.;
Kauer, M.;
Kim, G. S.;
Kim, H.;
Kim, H. J.;
Kim, K. W.;
Kim, N. Y.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H.;
Ko, Y. J.;
Kudryavtsev, V. A.;
Lee, H. S.;
Lee, J.;
Lee, J. Y.;
Lee, M. H.;
Leonard, D. S.;
Lynch, W. A.;
Maruyama, R. H.;
Mouton, F.;
Olsen, S. L.;
Park, B. J.;
Park, H. K.;
Park, H. S.;
Park, K. S.;
Pitta, R. L. C.;
Prihtiadi, H.;
Ra, S. J.;
Rott, C.;
Shin, K. A.;
Scarff, A.;
Spooner, N. J. C.;
Thompson, W. G.;
Yang, L.;
Yu, G. H.
Submitted: 2019-03-24, last modified: 2019-07-25
We present new constraints on the dark matter-induced annual modulation
signal using 1.7 years, of COSINE-100 data with a total exposure of 97.7
kg$\cdot$years. The COSINE-100 experiment, consisting of 106 kg of NaI(Tl)
target material, is designed to carry out a model-independent test of
DAMA/LIBRA's claim of WIMP discovery by searching for the same annual
modulation signal using the same NaI(Tl) target. The crystal data show a 2.7
cpd/kg/keV background rate on average in the 2--6 keV energy region of
interest. Using a $\chi$-squared minimization method we observe best fit values
for modulation amplitude and phase of 0.0092$\pm$0.0067 cpd/kg/keV and
127.2$\pm$45 d, respectively.
[7]
oai:arXiv.org:1904.00128 [pdf] - 1908653
COSINE-100 and DAMA/LIBRA-phase2 in WIMP effective models
Collaboration, COSINE-100;
:;
Adhikari, G.;
Adhikari, P.;
de Souza, E. Barbosa;
Carlin, N.;
Choi, S.;
Djamal, M.;
Ezeribe, A. C.;
Ha, C.;
Hahn, I. S.;
Jeon, E. J.;
Jo, J. H.;
Joo, H. W.;
Kang, W. G.;
Kang, W.;
Kauer, M.;
Kim, G. S.;
Kim, H.;
Kim, H. J.;
Kim, K. W.;
Kim, N. Y.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H.;
Ko, Y. J.;
Kudryavtsev, V. A.;
Lee, H. S.;
Lee, J.;
Lee, J. Y.;
Lee, M. H.;
Leonard, D. S.;
Lynch, W. A.;
Maruyama, R. H.;
Mouton, F.;
Olsen, S. L.;
Park, B. J.;
Park, H. K.;
Park, H. S.;
Park, K. S.;
Pitta, R. L. C.;
Prihtiadi, H.;
Ra, S. J.;
Rott, C.;
Shin, K. A.;
Scarff, A.;
Spooner, N. J. C.;
Thompson, W. G.;
Yang, L.;
Group, G. H. Yu. The Sogang Phenomenology;
:;
Kang, Sunghyun;
Scopel, Stefano;
Tomar, Gaurav;
Yoon, Jong-Hyun
Submitted: 2019-03-29, last modified: 2019-06-30
Assuming a standard Maxwellian for the WIMP velocity distribution, we obtain
the bounds from null WIMP search results of 59.5 days of COSINE-100 data on the
DAMA/LIBRA-phase2 modulation effect within the context of the non-relativistic
effective theory of WIMP-nucleus scattering. Here, we systematically assume
that one of the effective operators allowed by Galilean invariance dominates in
the effective Hamiltonian of a spin-1/2 dark matter (DM) particle. We find
that, although DAMA/LIBRA and COSINE-100 use the same sodium-iodide target, the
comparison of the two results still depends on the particle-physics model. This
is mainly due to two reasons: i) the WIMP signal spectral shape; ii) the
expected modulation fractions, when the upper bound on the time-averaged rate
in COSINE-100 is converted into a constraint on the annual modulation component
in DAMA/LIBRA. We find that the latter effect is the dominant one. For several
effective operators the expected modulation fractions are larger than in the
standard spin-independent or spin-dependent interaction cases. As a
consequence, compatibility between the modulation effect observed in DAMA/LIBRA
and the null result from COSINE-100 is still possible for several
non-relativistic operators. At low WIMP masses such relatively high values of
the modulation fractions arise because COSINE-100 is mainly sensitive to
WIMP-sodium scattering events, due to the higher threshold compared to
DAMA/LIBRA. A next COSINE analysis is expected to have a full sensitivity for
the 5$\sigma$ region of DAMA/LIBRA.
[8]
oai:arXiv.org:1906.01791 [pdf] - 1895649
An experiment to search for dark matter interactions using sodium iodide
detectors
Adhikari, Govinda;
Adhikari, Pushparaj;
de Souza, Estella Barbosa;
Carlin, Nelson;
Choi, Seonho;
Djamal, Mitra;
Ezeribe, Anthony C.;
Ha, Chang Hyon;
Hahn, Insik;
Hubbard, Antonia J. F.;
Jeon, Eunju;
Jo, Jay Hyun;
Joo, Hanwool;
Kang, Woon Gu;
Kang, Woosik;
Kauer, Matthew;
Kim, Bonghee;
Kim, Hyounggyu;
Kim, Hongjoo;
Kim, Kyungwon;
Kim, Nam Young;
Kim, Sun Kee;
Kim, Yeongduk;
Kim, Yong-Hamb;
Ko, Young Ju;
Kudryavtsev, Vitaly A.;
Lee, Hyun Su;
Lee, Jaison;
Lee, Jooyoung;
Lee, Moo Hyun;
Leonard, Douglas S.;
Lynch, Warren A.;
Maruyama, Reina H.;
Mouton, Frederic;
Olsen, Stephen L.;
Park, Byungju;
Park, Hyang Kyu;
Park, Hyeonseo;
Park, Jungsic;
Park, Kangsoon;
Pettus, Walter C.;
Prihtiadi, Hafizh;
Ra, Sejin;
Rott, Carsten;
Scarff, Andrew;
Shin, Keon Ah;
Spooner, Neil J. C.;
Thompson, William G.;
Yang, Liang;
Yong, Seok Hyun
Submitted: 2019-06-04
Observations of galaxies and primordial radiation suggest that the Universe
is made mostly of non-luminous dark matter. Several types of new fundamental
particles have been proposed as candidates for dark matter such as weakly
interacting massive particles (WIMPs) but no definitive signal has been seen
despite concerted efforts by many collaborations. One exception is the
much-debated claim by the DAMA collaboration of a statistically significant
annual modulation in the event rate of their experiment with a period and phase
consistent with that expected from WIMP dark matter. Several groups have been
working to develop experiments with the aim of reproducing DAMA's results using
the same target medium. Here we report results from the initial operation of
the COSINE-100 experiment. COSINE-100 uses sodium iodide as the target
medium-the same medium as DAMA-and is designed to carry out a model-independent
test of DAMA's claim. Initial data based on the first 59.5 days indicate that
there is no excess of events over the expected background, confirming that
DAMA's annual modulation signal is in severe tension with results from other
experiments under the assumption of dark matter having spin independent
interactions and the Standard Halo Model. COSINE-100 is now taking data to
study the presence of dark matter-induced annual modulation in the event rate
of the sodium iodide detectors.
[9]
oai:arXiv.org:1804.10697 [pdf] - 1877835
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive
Detector
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Banik, S.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Di Stefano, P. C. F.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Leyva, J. V.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E. H.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Romani, R. K.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
So, J.;
Speller, D.;
Stanford, C.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-04-27, last modified: 2019-05-03
We present the first limits on inelastic electron-scattering dark matter and
dark photon absorption using a prototype SuperCDMS detector having a charge
resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device).
These electron-recoil limits significantly improve experimental constraints on
dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We
demonstrate a sensitivity to dark photons competitive with other leading
approaches but using substantially less exposure (0.49 gram days). These
results demonstrate the scientific potential of phonon-mediated semiconductor
detectors that are sensitive to single electronic excitations.
[10]
oai:arXiv.org:1808.09098 [pdf] - 1873743
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood
Fit
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Banik, S.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
De Brienne, F.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Neog, H.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stanford, C.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-08-27, last modified: 2019-04-25
The Cryogenic Dark Matter Search low ionization threshold experiment
(CDMSlite) searches for interactions between dark matter particles and
germanium nuclei in cryogenic detectors. The experiment has achieved a low
energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark
matter particles. We present an analysis of the final CDMSlite data set, taken
with a different detector than was used for the two previous CDMSlite data
sets. This analysis includes a data "salting" method to protect against bias,
improved noise discrimination, background modeling, and the use of profile
likelihood methods to search for a dark matter signal in the presence of
backgrounds. We achieve an energy threshold of 70 eV and significantly improve
the sensitivity for dark matter particles with masses between 2.5 and 10
GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark
matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$
cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous
CDMSlite result.
[11]
oai:arXiv.org:1805.09942 [pdf] - 1867949
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS
Germanium Detectors
Agnese, Robert;
Aralis, Taylor;
Aramaki, Tsuguo;
Arnquist, Isaac;
Azadbakht, Elham;
Baker, William;
Banik, Samir;
Barker, D'Ann;
Bauer, Dan;
Binder, Thomas;
Bowles, Michael;
Brink, Paul;
Bunker, Ray;
Cabrera, Blas;
Calkins, Robert;
Cartaro, Concetta;
Cerdeno, David;
Chang, Yen-Yung;
Cooley, Jodi;
Cornell, Brett;
Cushman, Priscilla;
Di Stefano, Philippe;
Doughty, Todd;
Fascione, Eleanor;
Figueroa, Tali;
Fink, Caleb;
Fritts, Matt;
Gerbier, Gilles;
Germond, Richard;
Ghaith, Muad;
Golwala, Sunil;
Harris, Rusty;
Hong, Ziqing;
Hoppe, Eric;
Hsu, Lauren;
Huber, Martin;
Iyer, Vijay;
Jardin, Dan;
Jena, Chitrasen;
Kelsey, Michael;
Kennedy, Allison;
Kubik, Andrew;
Kurinsky, Noah;
Lawrence, Richard;
Loer, Ben;
Lopez-Asamar, Elias;
Lukens, Pat;
MacDonell, Danika;
Mahapatra, Rupak;
Mandic, Vuk;
Mast, Nicholas;
Miller, Eric;
Mirabolfathi, Nader;
Mohanty, Bedangadas;
Morales, Jorge;
Nelson, Jack;
Orrell, John;
Oser, Scott;
Page, William;
Partridge, Richard;
Pepin, Mark;
Ponce, Francisco;
Poudel, Sudip;
Pyle, Matt;
Qiu, Hang;
Rau, Wolfgang;
Reisetter, Angela;
Ren, Tom;
Reynolds, Tyler;
Roberts, Amy;
Robinson, Alan;
Rogers, Hannah;
Saab, Tarek;
Sadoulet, Bernard;
Sander, Joel;
Scarff, Andrew;
Schnee, Richard;
Scorza, Silvia;
Senapati, Kartik;
Serfass, Bruno;
Speller, Danielle;
Stein, Matthew;
Street, Joseph;
Tanaka, Hirohisa;
Toback, David;
Underwood, Ryan;
Villano, Anthony;
von Krosigk, Belina;
Watkins, Samuel;
Wilson, Jon;
Wilson, Matthew;
Winchell, Joshua;
Wright, Dennis;
Yellin, Steve;
Young, Betty;
Zhang, Xiaohe;
Zhao, Xuji
Submitted: 2018-05-24, last modified: 2019-04-16
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan
Underground Laboratory studied energy loss associated with Frenkel defect
formation in germanium crystals at mK temperatures using in situ $^{210}$Pb
sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its
expected 103 keV endpoint energy and determine an energy loss of
$\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this
result and using TRIM simulations, we extract the first experimentally
determined average displacement threshold energy of
$\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for
the analysis thresholds of future germanium-based dark matter searches.
[12]
oai:arXiv.org:1811.09344 [pdf] - 1863893
The First Direct Search for Inelastic Boosted Dark Matter with
COSINE-100
Ha, C.;
Adhikari, G.;
Adhikari, P.;
de Souza, E. Barbosa;
Carlin, N.;
Choi, S.;
Djamal, M.;
Ezeribe, A. C.;
Hahn, I. S.;
Jeon, E. J.;
Jo, J. H.;
Joo, H. W.;
Kang, W. G.;
Kang, W.;
Kauer, M.;
Kim, G. S.;
Kim, H.;
Kim, H. J.;
Kim, K. W.;
Kim, N. Y.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H.;
Ko, Y. J.;
Kudryavtsev, V. A.;
Lee, H. S.;
Lee, J.;
Lee, J. Y.;
Lee, M. H.;
Leonard, D. S.;
Lynch, W. A.;
Maruyama, R. H.;
Mouton, F.;
Olsen, S. L.;
Park, B. J.;
Park, H. K.;
Park, H. S.;
Park, K. S.;
Pitta, R. L. C.;
Prihtiadi, H.;
Ra, S. J.;
Rott, C.;
Shin, K. A.;
Scarff, A.;
Spooner, N. J. C.;
Thompson, W. G.;
Yang, L.;
Yu, G. H.
Submitted: 2018-11-22, last modified: 2019-01-30
A search for inelastic boosted dark matter (iBDM) using the COSINE-100
detector with 59.5 days of data is presented. This relativistic dark matter is
theorized to interact with the target material through inelastic scattering
with electrons, creating a heavier state that subsequently produces standard
model particles, such as an electron-positron pair. In this study, we search
for this electron-positron pair in coincidence with the initially scattered
electron as a signature for an iBDM interaction. No excess over the predicted
background event rate is observed. Therefore, we present limits on iBDM
interactions under various hypotheses, one of which allows us to explore an
area of the experimental search for iBDM using a terrestrial detector.
[13]
oai:arXiv.org:1806.09788 [pdf] - 1764379
The COSINE-100 Data Acquisition System
Collaboration, COSINE-100;
:;
Adhikari, G.;
Adhikari, P.;
de Souza, E. Barbosa;
Carlin, N.;
Choi, S.;
Choi, W.;
Djamal, M.;
Ezeribe, A. C.;
Ha, C.;
Hahn, I. S.;
Hubbard, A. J. F.;
Jeon, E. J.;
Jo, J. H.;
Joo, H. W.;
Kang, W. G.;
Kang, W. S.;
Kauer, M.;
Kim, H.;
Kim, H. J.;
Kim, K. W.;
Kim, M. C.;
Kim, N. Y.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H;
Kudryavtsev, V. A.;
Lee, H. S.;
Lee, J.;
Lee, M. H.;
Lim, K. E.;
Leonard, D. S.;
Maruyama, R. H.;
Mouton, F.;
Na, S.;
Olsen, S. L.;
Park, H. K.;
Park, H. S.;
Park, J. S.;
Park, K. S.;
Pettus, W.;
Prihtiadi, H.;
Rott, C.;
Scarff, A.;
Spooner, N. J. C.;
Thompson, W. G.;
Yang, L.
Submitted: 2018-06-26
COSINE-100 is a dark matter direct detection experiment designed to test the
annual modulation signal observed by the DAMA/LIBRA experiment. COSINE-100
consists of 8 NaI(Tl) crystals with a total mass of 106 kg, a 2200 L liquid
scintillator veto, and 37 muon detector panels. We present details of the data
acquisition system of COSINE-100, including waveform storage using flash
analog-to-digital converters for crystal events and integrated charge storage
using charge-sensitive analog-to-digital converters for liquid scintillator and
plastic scintillator muon veto events. We also discuss several trigger
conditions developed in order to distinguish signal events from photomultiplier
noise events. The total trigger rate observed for the crystal/liquid
scintillator (plastic scintillator) detector is 15 Hz (24 Hz).
[14]
oai:arXiv.org:1804.05167 [pdf] - 1709418
Background model for the NaI(Tl) crystals in COSINE-100
Adhikari, P.;
Adhikari, G.;
de Souza, E. Barbosa;
Carlin, N.;
Choi, S.;
Choi, W. Q.;
Djamal, M.;
Ezeribe, A. C.;
Ha, C.;
Hahn, I. S.;
Hubbard, A. J. F.;
Jeon, E. J.;
Jo, J. H.;
Joo, H. W.;
Kang, W. G.;
Kauer, M.;
Kang, W. S.;
Kim, B. H.;
Kim, H.;
Kim, H. J.;
Kim, K. W.;
Kim, M. C.;
Kim, N. Y.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H.;
Kudryavtsev, V. A.;
Lee, H. S.;
Lee, J.;
Lee, J. Y.;
Lee, M. H.;
Leonard, D. S.;
Lynch, W. A.;
Maruyama, R. H.;
Mouton, F.;
Olsen, S. L.;
Park, H. K.;
Park, H. S.;
Park, J. S.;
Park, K. S.;
Pettus, W.;
Prihtiadi, H.;
Ra, S.;
Rott, C.;
Scarff, A.;
Spooner, N. J. C.;
Thompson, W. G.;
Yang, L.;
Yong, S. H.
Submitted: 2018-04-14, last modified: 2018-06-11
The COSINE-100 dark matter search experiment is an array of NaI(Tl) crystal
detectors located in the Yangyang Underground Laboratory (Y2L). To understand
measured backgrounds in the NaI(Tl) crystals we have performed Monte Carlo
simulations using the Geant4 toolkit and developed background models for each
crystal that consider contributions from both internal and external sources,
including cosmogenic nuclides. The background models are based on comparisons
of measurement data with Monte Carlo simulations that are guided by a campaign
of material assays and are used to evaluate backgrounds and identify their
sources. The average background level for the six crystals (70 kg total mass)
that are studied is 3.5 counts/day/keV/kg in the (2-6) keV energy interval. The
dominant contributors in this energy region are found to be $^{210}$Pb and
$^3$H.
[15]
oai:arXiv.org:1711.00943 [pdf] - 1648681
Performance of 20:1 multiplexer for large area charge readouts in
directional dark matter TPC detectors
Submitted: 2017-11-02, last modified: 2018-03-12
More target mass is required in current TPC based directional dark matter
detectors for improved detector sensitivity. This can be achieved by scaling up
the detector volumes, but this results in the need for more analogue signal
channels. A possible solution to reducing the overall cost of the charge
readout electronics is to multiplex the signal readout channels. Here, we
present a multiplexer system in expanded mode based on LMH6574 chips produced
by Texas Instruments, originally designed for video processing. The setup has a
capability of reducing the number of readouts in such TPC detectors by a factor
of 20. Results indicate that the important charge distribution asymmetry along
an ionization track is retained after multiplexed signals are demultiplexed.
[16]
oai:arXiv.org:1710.05299 [pdf] - 1648653
Initial Performance of the COSINE-100 Experiment
Adhikari, G.;
Adhikari, P.;
de Souza, E. Barbosa;
Carlin, N.;
Choi, S.;
Choi, W. Q.;
Djamal, M.;
Ezeribe, A. C.;
Ha, C.;
Hahn, I. S.;
Hubbard, A. J. F.;
Jeon, E. J.;
Jo, J. H.;
Joo, H. W.;
Kang, W.;
Kang, W. G.;
Kauer, M.;
Kim, B. H.;
Kim, H.;
Kim, H. J.;
Kim, K. W.;
Kim, M. C.;
Kim, N. Y.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H.;
Kudryavtsev, V. A.;
Lee, H. S.;
Lee, J.;
Lee, J. Y.;
Lee, M. H.;
Leonard, D. S.;
Lim, K. E.;
Lynch, W. A.;
Maruyama, R. H.;
Mouton, F.;
Olsen, S. L.;
Park, H. K.;
Park, H. S.;
Park, J. S.;
Park, K. S.;
Pettus, W.;
Pierpoint, Z. P.;
Prihtiadi, H.;
Ra, S.;
Rogers, F. R.;
Rott, C.;
Scarff, A.;
Spooner, N. J. C.;
Thompson, W. G.;
Yang, L.;
Yong, S. H.
Submitted: 2017-10-15, last modified: 2018-02-11
COSINE is a dark matter search experiment based on an array of low background
NaI(Tl) crystals located at the Yangyang underground laboratory. The assembly
of COSINE-100 was completed in the summer of 2016 and the detector is currently
collecting physics quality data aimed at reproducing the DAMA/LIBRA experiment
that reported an annual modulation signal. Stable operation has been achieved
and will continue for at least two years. Here, we describe the design of
COSINE-100, including the shielding arrangement, the configuration of the
NaI(Tl) crystal detection elements, the veto systems, and the associated
operational systems, and we show the current performance of the experiment.
[17]
oai:arXiv.org:1712.02011 [pdf] - 1648729
Muon detector for the COSINE-100 experiment
Collaboration, COSINE-100;
:;
Prihtiadi, H.;
Adhikari, G.;
Adhikari, P.;
de Souza, E. Barbosa;
Carlin, N.;
Choi, S.;
Choi, W. Q.;
Djamal, M.;
Ezeribe, A. C.;
Ha, C.;
Hahn, I. S.;
Hubbard, A. J. F.;
Jeon, E. J.;
Jo, J. H.;
Joo, H. W.;
Kang, W.;
Kang, W. G.;
Kauer, M.;
Kim, B. H.;
Kim, H.;
Kim, H. J.;
Kim, K. W.;
Kim, N. Y.;
Kim, S. K.;
Kim, Y. D.;
Kim, Y. H.;
Kudryavtsev, V. A.;
Lee, H. S.;
Lee, J.;
Lee, J. Y.;
Lee, M. H.;
Leonard, D. S.;
Lim, K. E.;
Lynch, W. A.;
Maruyama, R. H.;
Mouton, F.;
Olsen, S. L.;
Park, H. K.;
Park, H. S.;
Park, J. S.;
Park, K. S.;
Pettus, W.;
Pierpoint, Z. P.;
Ra, S.;
Rogers, F. R.;
Rott, C.;
Scarff, A.;
Spooner, N. J. C.;
Thompson, W. G.;
Yang, L.;
Yong, S. H.
Submitted: 2017-12-05
The COSINE-100 dark matter search experiment has started taking physics data
with the goal of performing an independent measurement of the annual modulation
signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic
scintillator panels in the outermost layer of the shield surrounding the
COSINE-100 detector. It is used to detect cosmic ray muons in order to
understand the impact of the muon annual modulation on dark matter analysis.
Assembly and initial performance test of each module have been performed at a
ground laboratory. The installation of the detector in Yangyang Underground
Laboratory (Y2L) was completed in the summer of 2016. Using three months of
data, the muon underground flux was measured to be 328 $\pm$ 1(stat.)$\pm$
10(syst.) muons/m$^2$/day. In this report, the assembly of the muon detector
and the results from the analysis are presented.
[18]
oai:arXiv.org:1707.07772 [pdf] - 1586332
Demonstration of radon removal from SF$_6$ using molecular sieves
Submitted: 2017-07-24, last modified: 2017-10-04
The gas SF$_6$ has become of interest as a negative ion drift gas for use in
directional dark matter searches. However, as for other targets in such
searches, it is important that radon contamination can be removed as this
provides a source of unwanted background events. In this work we demonstrate
for the first time filtration of radon from SF$_6$ gas by using a molecular
sieve. Four types of sieves from Sigma-Aldrich were investigated, namely
3{\AA}, 4{\AA}, 5{\AA} and 13X. A manufactured radon source was used for the
tests. This was attached to a closed loop system in which gas was flowed
through the filters and a specially adapted Durridge RAD7 radon detector. In
these measurements, it was found that only the 5{\AA} type was able to
significantly reduce the radon concentration without absorbing the SF$_6$ gas.
The sieve was able to reduce the initial radon concentration of 3875 $\pm$ 13
Bqm$^{-3}$ in SF$_6$ gas by 87% when cooled with dry ice. The ability of the
cooled 5{\AA} molecular sieve filter to significantly reduce radon
concentration from SF$_6$ provides a promising foundation for the construction
of a radon filtration setup for future ultra-sensitive SF$_6$ gas rare-event
physics experiments.
[19]
oai:arXiv.org:1707.09431 [pdf] - 1586535
Measurement of directional range components of nuclear recoil tracks in
a fiducialised dark matter detector
Battat, J. B. R.;
Daw, E. J.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Harton, J. L.;
Lafler, R.;
Lee, E. R.;
Loomba, D.;
Lynch, W.;
Miller, E. H.;
Mouton, F.;
Paling, S.;
Phan, N.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F. G.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.
Submitted: 2017-07-28
We present results from the first measurement of axial range components of
fiducialized neutron induced nuclear recoil tracks using the DRIFT directional
dark matter detector. Nuclear recoil events are fiducialized in the DRIFT
experiment using temporal charge carrier separations between different species
of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this
measurement, neutron-induced nuclear recoil tracks were generated by exposing
the detector to $^{252}$Cf source from different directions. Using these
events, the sensitivity of the detector to the expected axial directional
signatures were investigated as the neutron source was moved from one detector
axis to another. Results obtained from these measurements show clear
sensitivity of the DRIFT detector to the axial directional signatures in this
fiducialization gas mode.
[21]
oai:arXiv.org:1701.00171 [pdf] - 1564000
Low Threshold Results and Limits from the DRIFT Directional Dark Matter
Detector
Battat, J. B. R.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Harton, J. L.;
Lafler, R.;
Law, E.;
Lee, E. R.;
Loomba, D.;
Lumnah, A.;
Miller, E. H.;
Monte, A.;
Mouton, F.;
Paling, S. M.;
Phan, N. S.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F. G.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Waldram, N.
Submitted: 2016-12-31, last modified: 2017-03-27
We present results from a 54.7 live-day shielded run of the DRIFT-IId
detector, the world's most sensitive, directional, dark matter detector.
Several improvements were made relative to our previous work including a lower
threshold for detection, a more robust analysis and a tenfold improvement in
our gamma rejection factor. After analysis, no events remain in our fiducial
region leading to an exclusion curve for spin-dependent WIMP-proton
interactions which reaches 0.28 pb at 100 GeV/c^2 a fourfold improvement on our
previous work. We also present results from a 45.4 live-day unshielded run of
the DRIFT-IId detector during which 14 nuclear recoil-like events were
observed. We demonstrate that the observed nuclear recoil rate of 0.31+/-0.08
events per day is consistent with detection of ambient, fast neutrons emanating
from the walls of the Boulby Underground Science Facility.
[22]
oai:arXiv.org:1602.05939 [pdf] - 1538892
First search for a dark matter annual modulation signal with NaI(Tl) in
the Southern Hemisphere by DM-Ice17
Collaboration, DM-Ice;
:;
de Souza, E. Barbosa;
Cherwinka, J.;
Cole, A.;
Ezeribe, A. C.;
Grant, D.;
Halzen, F.;
Heeger, K. M.;
Hsu, L.;
Hubbard, A. J. F.;
Jo, J. H.;
Karle, A.;
Kauer, M.;
Kudryavtsev, V. A.;
Lim, K. E.;
Macdonald, C.;
Maruyama, R. H.;
Mouton, F.;
Paling, S. M.;
Pettus, W.;
Pierpoint, Z. P.;
Reilly, B. N.;
Robinson, M.;
Rogers, F. R.;
Sandstrom, P.;
Scarff, A.;
Spooner, N. J. C.;
Telfer, S.;
Yang, L.
Submitted: 2016-02-18, last modified: 2017-02-28
We present the first search for a dark matter annual modulation signal in the
Southern Hemisphere conducted with NaI(Tl) detectors, performed by the DM-Ice17
experiment. Nuclear recoils from dark matter interactions are expected to yield
an annually modulated signal independent of location within the Earth's
hemispheres. DM-Ice17, the first step in the DM-Ice experimental program,
consists of 17 kg of NaI(Tl) located at the South Pole under 2200 m.w.e.
overburden of Antarctic glacial ice. Taken over 3.6 years for a total exposure
of 60.8 kg yr, DM-Ice17 data are consistent with no modulation in the energy
range of 4-20 keV, providing the strongest limits on weakly interacting massive
particle dark matter from a direct detection experiment located in the Southern
Hemisphere. The successful deployment and stable long-term operation of
DM-Ice17 establishes the South Pole ice as a viable location for future dark
matter searches and in particular for a high-sensitivity NaI(Tl) dark matter
experiment to directly test the DAMA/LIBRA claim of the observation of dark
matter.
[23]
oai:arXiv.org:1410.7821 [pdf] - 1250420
First background-free limit from a directional dark matter experiment:
results from a fully fiducialised DRIFT detector
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Gold, M.;
Harton, J. L.;
Landers, J. M.;
Law, E.;
Lee, E. R.;
Loomba, D.;
Lumnah, A.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Mouton, F.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Vahsen, S. E.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-10-28, last modified: 2015-07-23
The addition of O2 to gas mixtures in time projection chambers containing CS2
has recently been shown to produce multiple negative ions that travel at
slightly different velocities. This allows a measurement of the absolute
position of ionising events in the z (drift) direction. In this work, we apply
the z-fiducialisation technique to a directional dark matter search. In
particular, we present results from a 46.3 live-day source-free exposure of the
DRIFT-IId detector run in this completely new mode. With full-volume
fiducialisation, we have achieved the first background-free operation of a
directional detector. The resulting exclusion curve for spin-dependent
WIMP-proton interactions reaches 1.1 pb at 100 GeV/c2, a factor of 2 better
than our previous work. We describe the automated analysis used here, and argue
that detector upgrades, implemented after the acquisition of these data, will
bring an additional factor of >3 improvement in the near future.
[24]
oai:arXiv.org:1407.3938 [pdf] - 1215675
Radon in the DRIFT-II directional dark matter TPC: emanation, detection
and mitigation
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Fox, J. R.;
Gauvreau, J. -L.;
Gold, M.;
Harmon, L. J.;
Harton, J. L.;
Landers, J. M.;
Lee, E. R.;
Loomba, D.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Pipe, M.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-07-15, last modified: 2014-08-25
Radon gas emanating from materials is of interest in environmental science
and also a major concern in rare event non-accelerator particle physics
experiments such as dark matter and double beta decay searches, where it is a
major source of background. Notable for dark matter experiments is the
production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils
of radon daughter isotopes, which can mimic the signal expected from WIMP
interactions. Presented here are results of measurements of radon emanation
from detector materials in the 1 metre cubed DRIFT-II directional dark matter
gas time projection chamber experiment. Construction and operation of a radon
emanation facility for this work is described, along with an analysis to
continuously monitor DRIFT data for the presence of internal 222Rn and 218Po.
Applying this analysis to historical DRIFT data, we show how systematic
substitution of detector materials for alternatives, selected by this device
for low radon emanation, has resulted in a factor of ~10 reduction in internal
radon rates. Levels are found to be consistent with the sum from separate radon
emanation measurements of the internal materials and also with direct
measurement using an attached alpha spectrometer. The current DRIFT detector,
DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 {\mu}Bq/l with current
analysis efficiency, potentially opening up DRIFT technology as a new tool for
sensitive radon assay of materials.
[25]
oai:arXiv.org:1404.2253 [pdf] - 934775
Background Assay and Rejection in DRIFT
Brack, Jeff;
Daw, Ed;
Dorofeev, Alexei;
Ezeribe, Anthony;
Gauvreau, Jean-Luc;
Gold, Michael;
Harton, John;
Lafler, Randy;
Lauer, Robert;
Lee, Eric R.;
Loomba, Dinesh;
Matthews, John;
Miller, Eric H.;
Monte, Alissa;
Murphy, Alex;
Paling, Sean;
Phan, Nguyen;
Sadler, Steve;
Scarff, Andrew;
Snowden-Ifft, Daniel;
Spooner, Neil;
Telfer, Sam;
Walker, Daniel;
Williams, Matt;
Yuriev, Leonid
Submitted: 2014-04-08
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with
directional sensitivity to WIMP-induced nuclear recoils. Its primary
backgrounds were due to alpha decays from contamination on the central cathode.
Efforts to reduce these backgrounds led to replacing the 20 \mu m wire central
cathode with one constructed from 0.9 \mu m aluminized mylar, which is almost
totally transparent to alpha particles. Detailed modeling of the nature and
origin of the remaining backgrounds led to an in-situ, ppt-sensitive assay of
alpha decay backgrounds from the central cathode. This led to further
improvements in the thin-film cathode resulting in over 2 orders of magnitude
reduction in backgrounds compared to the wire cathode. Finally, the addition of
O$_2$ to CS$_2$ gas was found to produce multiple species of electronegative
charge carriers, providing a method to determine the absolute position of
nuclear recoils and reject all known remaining backgrounds while retaining a
high efficiency for nuclear recoil detection.