Normalized to: Sawyer, D.
[1]
oai:arXiv.org:2003.08851 [pdf] - 2077086
An Extreme Precision Radial Velocity Pipeline: First Radial Velocities
from EXPRES
Petersburg, Ryan R.;
Ong, J. M. Joel;
Zhao, Lily L.;
Blackman, Ryan T.;
Brewer, John M.;
Buchhave, Lars A.;
Cabot, Samuel H. C.;
Davis, Allen B.;
Jurgenson, Colby A.;
Leet, Christopher;
McCracken, Tyler M.;
Sawyer, David;
Sharov, Mikhail;
Tronsgaard, René;
Szymkowiak, Andrew E.;
Fischer, Debra A.
Submitted: 2020-03-19
The EXtreme PREcision Spectrograph (EXPRES) is an environmentally stabilized,
fiber-fed, $R=137,500$, optical spectrograph. It was recently commissioned at
the 4.3-m Lowell Discovery Telescope (LDT) near Flagstaff, Arizona. The
spectrograph was designed with a target radial-velocity (RV) precision of
30$\mathrm{~cm~s^{-1}}$. In addition to instrumental innovations, the EXPRES
pipeline, presented here, is the first for an on-sky, optical, fiber-fed
spectrograph to employ many novel techniques---including an "extended flat"
fiber used for wavelength-dependent quantum efficiency characterization of the
CCD, a flat-relative optimal extraction algorithm, chromatic barycentric
corrections, chromatic calibration offsets, and an ultra-precise laser
frequency comb for wavelength calibration. We describe the reduction,
calibration, and radial-velocity analysis pipeline used for EXPRES and present
an example of our current sub-meter-per-second RV measurement precision, which
reaches a formal, single-measurement error of 0.3$\mathrm{~m~s^{-1}}$ for an
observation with a per-pixel signal-to-noise ratio of 250. These velocities
yield an orbital solution on the known exoplanet host 51 Peg that matches
literature values with a residual RMS of 0.895$\mathrm{~m~s^{-1}}$.
[2]
oai:arXiv.org:2003.08852 [pdf] - 2089157
Performance Verification of the EXtreme PREcision Spectrograph
Blackman, Ryan T.;
Fischer, Debra A.;
Jurgenson, Colby A.;
Sawyer, David;
McCracken, Tyler M.;
Szymkowiak, Andrew E.;
Petersburg, Ryan R.;
Ong, J. M. Joel;
Brewer, John M.;
Zhao, Lily L.;
Leet, Christopher;
Buchhave, Lars A.;
Tronsgaard, René;
Llama, Joe;
Sawyer, Travis;
Davis, Allen B.;
Cabot, Samuel H. C.;
Shao, Michael;
Trahan, Russell;
Nemati, Bijan;
Genoni, Matteo;
Pariani, Giorgio;
Riva, Marco;
Probst, Rafael A.;
Holzwarth, Ronald;
Steinmetz, Tilo;
Fournier, Paul;
Pawluczyk, Rafal
Submitted: 2020-03-19
The EXtreme PREcision Spectrograph (EXPRES) is a new Doppler spectrograph
designed to reach a radial velocity measurement precision sufficient to detect
Earth-like exoplanets orbiting nearby, bright stars. We report on extensive
laboratory testing and on-sky observations to quantitatively assess the
instrumental radial velocity measurement precision of EXPRES, with a focused
discussion of individual terms in the instrument error budget. We find that
EXPRES can reach a single-measurement instrument calibration precision better
than 10 cm/s, not including photon noise from stellar observations. We also
report on the performance of the various environmental, mechanical, and optical
subsystems of EXPRES, assessing any contributions to radial velocity error. For
atmospheric and telescope related effects, this includes the fast tip-tilt
guiding system, atmospheric dispersion compensation, and the chromatic exposure
meter. For instrument calibration, this includes the laser frequency comb
(LFC), flat-field light source, CCD detector, and effects in the optical
fibers. Modal noise is mitigated to a negligible level via a chaotic fiber
agitator, which is especially important for wavelength calibration with the
LFC. Regarding detector effects, we empirically assess the impact on radial
velocity precision due to pixel-position non-uniformities (PPNU) and charge
transfer inefficiency (CTI). EXPRES has begun its science survey to discover
exoplanets orbiting G-dwarf and K-dwarf stars, in addition to transit
spectroscopy and measurements of the Rossiter-McLaughlin effect.
[3]
oai:arXiv.org:1802.01642 [pdf] - 1637702
Modal Noise Mitigation through Fiber Agitation for Fiber-fed Radial
Velocity Spectrographs
Submitted: 2018-02-05
Optical fiber modal noise is a limiting factor for high precision
spectroscopy signal-to-noise in the near-infrared and visible. Unabated,
especially when using highly coherent light sources for wavelength calibration,
modal noise can induce radial velocity (RV) errors that hinder the discovery of
low-mass (and potentially Earth-like) planets. Previous research in this field
has found sufficient modal noise mitigation through the use of an integrating
sphere, but this requires extremely bright light sources, a luxury not
necessarily afforded by the next generation of high-resolution optical
spectrographs. Otherwise, mechanical agitation, which "mixes" the fiber's modal
patterns and allows the noise to be averaged over minutes-long exposures,
provides some noise reduction but the exact mechanism behind improvement in
signal-to-noise and RV drift has not been fully explored or optimized by the
community. Therefore, we have filled out the parameter space of modal noise
agitation techniques in order to better understand agitation's contribution to
mitigating modal noise and to discover a better method for agitating fibers. We
find that modal noise is best suppressed by the quasi-chaotic motion of two
high-amplitude agitators oscillating with varying phase for fibers with large
core diameters and low azimuthal symmetry. This work has subsequently
influenced the design of a fiber agitator, to be installed with the EXtreme
PREcision Spectrograph, that we estimate will reduce modal-noise-induced RV
error to less than 3.2 cm/s.
[4]
oai:arXiv.org:1606.04413 [pdf] - 1530831
EXPRES: A Next Generation RV Spectrograph in the Search for Earth-like
Worlds
Submitted: 2016-06-14
The EXtreme PREcision Spectrograph (EXPRES) is an optical fiber fed echelle
instrument being designed and built at the Yale Exoplanet Laboratory to be
installed on the 4.3-meter Discovery Channel Telescope operated by Lowell
Observatory. The primary science driver for EXPRES is to detect Earth-like
worlds around Sun-like stars. With this in mind, we are designing the
spectrograph to have an instrumental precision of 15 cm/s so that the on-sky
measurement precision (that includes modeling for RV noise from the star) can
reach to better than 30 cm/s. This goal places challenging requirements on
every aspect of the instrument development, including optomechanical design,
environmental control, image stabilization, wavelength calibration, and data
analysis. In this paper we describe our error budget, and instrument
optomechanical design.
[5]
oai:arXiv.org:1602.07939 [pdf] - 1411343
State of the Field: Extreme Precision Radial Velocities
Fischer, Debra;
Anglada-Escude, Guillem;
Arriagada, Pamela;
Baluev, Roman V.;
Bean, Jacob L.;
Bouchy, Francois;
Buchhave, Lars A.;
Carroll, Thorsten;
Chakraborty, Abhijit;
Crepp, Justin R.;
Dawson, Rebekah I.;
Diddams, Scott A.;
Dumusque, Xavier;
Eastman, Jason D.;
Endl, Michael;
Figueira, Pedro;
Ford, Eric B.;
Foreman-Mackey, Daniel;
Fournier, Paul;
Furesz, Gabor;
Gaudi, B. Scott;
Gregory, Philip C.;
Grundahl, Frank;
Hatzes, Artie P.;
Hebrard, Guillaume;
Herrero, Enrique;
Hogg, David W.;
Howard, Andrew W.;
Johnson, John A.;
Jorden, Paul;
Jurgenson, Colby A.;
Latham, David W.;
Laughlin, Greg;
Loredo, Thomas J.;
Lovis, Christophe;
Mahadevan, Suvrath;
McCracken, Tyler M.;
Pepe, Francesco;
Perez, Mario;
Phillips, David F.;
Plavchan, Peter P.;
Prato, Lisa;
Quirrenbach, Andreas;
Reiners, Ansgar;
Robertson, Paul;
Santos, Nuno C.;
Sawyer, David;
Segransan, Damien;
Sozzetti, Alessandro;
Steinmetz, Tilo;
Szentgyorgyi, Andrew;
Udry, Stephane;
Valenti, Jeff A.;
Wang, Sharon X.;
Wittenmyer, Robert A.;
Wright, Jason T.
Submitted: 2016-02-25, last modified: 2016-02-27
The Second Workshop on Extreme Precision Radial Velocities defined circa 2015
the state of the art Doppler precision and identified the critical path
challenges for reaching 10 cm/s measurement precision. The presentations and
discussion of key issues for instrumentation and data analysis and the workshop
recommendations for achieving this precision are summarized here.
Beginning with the HARPS spectrograph, technological advances for precision
radial velocity measurements have focused on building extremely stable
instruments. To reach still higher precision, future spectrometers will need to
produce even higher fidelity spectra. This should be possible with improved
environmental control, greater stability in the illumination of the
spectrometer optics, better detectors, more precise wavelength calibration, and
broader bandwidth spectra. Key data analysis challenges for the precision
radial velocity community include distinguishing center of mass Keplerian
motion from photospheric velocities, and the proper treatment of telluric
contamination. Success here is coupled to the instrument design, but also
requires the implementation of robust statistical and modeling techniques.
Center of mass velocities produce Doppler shifts that affect every line
identically, while photospheric velocities produce line profile asymmetries
with wavelength and temporal dependencies that are different from Keplerian
signals.
Exoplanets are an important subfield of astronomy and there has been an
impressive rate of discovery over the past two decades. Higher precision radial
velocity measurements are required to serve as a discovery technique for
potentially habitable worlds and to characterize detections from transit
missions. The future of exoplanet science has very different trajectories
depending on the precision that can ultimately be achieved with Doppler
measurements.
[6]
oai:arXiv.org:1601.06024 [pdf] - 1345386
Design and Construction of VUES: the Vilnius University Echelle
Spectrograph
Submitted: 2016-01-22
In February of 2014 the Yale Exoplanet Laboratory was commissioned to design,
build, and deliver a high resolution (R = 60,000) spectrograph for the
1.65-meter telescope at the Moletai Astronomical Observatory. The observatory
is operated by the Institute of Theoretical Physics and Astronomy at Vilnius
University. The Vilnius University Echelle Spectrograph (VUES) is a white-pupil
design that is fed via an octagonal fiber from the telescope and has an
operational bandpass from 400 to 880 nm. VUES incorporates a novel modular
optomechanical design that allows for quick assembly and alignment on
commercial optical tables. This approach allowed the spectrograph to be
assembled and commissioned at Yale using lab optical tables and then
reassembled at the observatory on a different optical table with excellent
repeatability. The assembly and alignment process for the spectrograph was
reduced to a few days, allowing the spectrograph to be completely disassembled
for shipment to Lithuania, and then installed at the observatory during a
10-day period in June of 2015.
[7]
oai:arXiv.org:1106.1706 [pdf] - 371192
The BigBOSS Experiment
Schlegel, D.;
Abdalla, F.;
Abraham, T.;
Ahn, C.;
Prieto, C. Allende;
Annis, J.;
Aubourg, E.;
Azzaro, M.;
Baltay, S. Bailey. C.;
Baugh, C.;
Bebek, C.;
Becerril, S.;
Blanton, M.;
Bolton, A.;
Bromley, B.;
Cahn, R.;
Carton, P. -H.;
Cervantes-Cota, J. L.;
Chu, Y.;
Cortes, M.;
Dawson, K.;
Dey, A.;
Dickinson, M.;
Diehl, H. T.;
Doel, P.;
Ealet, A.;
Edelstein, J.;
Eppelle, D.;
Escoffier, S.;
Evrard, A.;
Faccioli, L.;
Frenk, C.;
Geha, M.;
Gerdes, D.;
Gondolo, P.;
Gonzalez-Arroyo, A.;
Grossan, B.;
Heckman, T.;
Heetderks, H.;
Ho, S.;
Honscheid, K.;
Huterer, D.;
Ilbert, O.;
Ivans, I.;
Jelinsky, P.;
Jing, Y.;
Joyce, D.;
Kennedy, R.;
Kent, S.;
Kieda, D.;
Kim, A.;
Kim, C.;
Kneib, J. -P.;
Kong, X.;
Kosowsky, A.;
Krishnan, K.;
Lahav, O.;
Lampton, M.;
LeBohec, S.;
Brun, V. Le;
Levi, M.;
Li, C.;
Liang, M.;
Lim, H.;
Lin, W.;
Linder, E.;
Lorenzon, W.;
de la Macorra, A.;
Magneville, Ch.;
Malina, R.;
Marinoni, C.;
Martinez, V.;
Majewski, S.;
Matheson, T.;
McCloskey, R.;
McDonald, P.;
McKay, T.;
McMahon, J.;
Menard, B.;
Miralda-Escude, J.;
Modjaz, M.;
Montero-Dorta, A.;
Morales, I.;
Mostek, N.;
Newman, J.;
Nichol, R.;
Nugent, P.;
Olsen, K.;
Padmanabhan, N.;
Palanque-Delabrouille, N.;
Park, I.;
Peacock, J.;
Percival, W.;
Perlmutter, S.;
Peroux, C.;
Petitjean, P.;
Prada, F.;
Prieto, E.;
Prochaska, J.;
Reil, K.;
Rockosi, C.;
Roe, N.;
Rollinde, E.;
Roodman, A.;
Ross, N.;
Rudnick, G.;
Ruhlmann-Kleider, V.;
Sanchez, J.;
Sawyer, D.;
Schimd, C.;
Schubnell, M.;
Scoccimaro, R.;
Seljak, U.;
Seo, H.;
Sheldon, E.;
Sholl, M.;
Shulte-Ladbeck, R.;
Slosar, A.;
Smith, D. S.;
Smoot, G.;
Springer, W.;
Stril, A.;
Szalay, A. S.;
Tao, C.;
Tarle, G.;
Taylor, E.;
Tilquin, A.;
Tinker, J.;
Valdes, F.;
Wang, J.;
Wang, T.;
Weaver, B. A.;
Weinberg, D.;
White, M.;
Wood-Vasey, M.;
Yang, J.;
Yeche, X. Yang. Ch.;
Zakamska, N.;
Zentner, A.;
Zhai, C.;
Zhang, P.
Submitted: 2011-06-09
BigBOSS is a Stage IV ground-based dark energy experiment to study baryon
acoustic oscillations (BAO) and the growth of structure with a wide-area galaxy
and quasar redshift survey over 14,000 square degrees. It has been
conditionally accepted by NOAO in response to a call for major new
instrumentation and a high-impact science program for the 4-m Mayall telescope
at Kitt Peak. The BigBOSS instrument is a robotically-actuated, fiber-fed
spectrograph capable of taking 5000 simultaneous spectra over a wavelength
range from 340 nm to 1060 nm, with a resolution R = 3000-4800.
Using data from imaging surveys that are already underway, spectroscopic
targets are selected that trace the underlying dark matter distribution. In
particular, targets include luminous red galaxies (LRGs) up to z = 1.0,
extending the BOSS LRG survey in both redshift and survey area. To probe the
universe out to even higher redshift, BigBOSS will target bright [OII] emission
line galaxies (ELGs) up to z = 1.7. In total, 20 million galaxy redshifts are
obtained to measure the BAO feature, trace the matter power spectrum at smaller
scales, and detect redshift space distortions. BigBOSS will provide additional
constraints on early dark energy and on the curvature of the universe by
measuring the Ly-alpha forest in the spectra of over 600,000 2.2 < z < 3.5
quasars.
BigBOSS galaxy BAO measurements combined with an analysis of the broadband
power, including the Ly-alpha forest in BigBOSS quasar spectra, achieves a FOM
of 395 with Planck plus Stage III priors. This FOM is based on conservative
assumptions for the analysis of broad band power (kmax = 0.15), and could grow
to over 600 if current work allows us to push the analysis to higher wave
numbers (kmax = 0.3). BigBOSS will also place constraints on theories of
modified gravity and inflation, and will measure the sum of neutrino masses to
0.024 eV accuracy.