Normalized to: Sawano, T.
[1]
oai:arXiv.org:1904.10775 [pdf] - 1898030
Exponentially Decaying Extended Emissions Following Short Gamma-Ray
Bursts with Possible Luminosity -- E-folding Time Correlation
Submitted: 2019-04-24
The origin of extended emissions following prompt emissions of short
gamma-ray bursts (SGRBs) is in mystery. The long-term activity of the extended
emission is responsible for promising electromagnetic counterparts to
gravitational waves and, so that it may be a key to uncovering the progenitor
of SGRBs. We investigate the early X-ray light curves of 26 SGRBs with known
redshifts observed with the X-Ray Telescope aboard the {\it Neil Gehrels Swift
Observatory} ({\it Swift}). We find that the exponential temporal decay model
is able to describe the extended emissions comprehensively with a rest-frame
e-folding time of 20 -- 200 seconds. We also estimate the isotropic equivalent
energies of the extended emission with the exponential decay model and of the
prompt emission, compared with those of the prompt emission. Then, it is
revealed that the extended emission is 0 -- 3 orders of magnitude less powerful
than the prompt emission. We find a strong correlation between the expected
maximum luminosity and e-folding time which can be described by a power-law
with an index of $-3.3$ and whose chance probability of $8.2\times10^{-6}$ if
there is no observation bias of {\it Swift}. The exponential temporal decay may
be interpreted to come from the spin-down time scale of the rotation energy of
a highly magnetized neutron star, and/or fallback accretion onto a disk
surrounding a black hole with an exponentially decaying magnetic flux by
magnetic reconnection.
[2]
oai:arXiv.org:1903.05963 [pdf] - 1875381
Systematic study for gas-to-dust ratio of short gamma-ray burst
afterglows
Submitted: 2019-03-14
Extra-galactic X-ray absorption and optical extinction are often found in
gamma-ray burst (GRB) afterglows and they could be tracers of both circumburst
and host galaxy environments. By performing spectral analyses for spectral
energy distribution of 9 short GRB (SGRB) afterglows with known redshift, we
investigated a ratio of the equivalent hydrogen column density to the dust
extinction, N^{rest}_{H}/A^{rest}_{V}, in the rest frame of each SGRB. We found
that the distribution of N^{rest}_{H}/A^{rest}_{V} is systematically smaller
than the one for long GRBs, and is roughly consistent with the gas-to-dust
ratio in the Milky Way. This result means that the measured gas-to-dust ratio
of SGRBs would originate from the interstellar medium in each host galaxy. This
scenario supports the prediction that SGRBs occur in non star-forming regions
in the host galaxies.
[3]
oai:arXiv.org:1703.07600 [pdf] - 1564143
Imaging Polarimeter for a Sub-MeV Gamma-Ray All-Sky Survey using an
Electron-Tracking Compton Camera
Komura, Shotaro;
Takada, Atsushi;
Mizumura, Yoshitaka;
Miyamoto, Shohei;
Takemura, Taito;
Kishimoto, Tetsuro;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Matsuoka, Yoshihiro;
Miuchi, Kentaro;
Mizumoto, Tetsuya;
Nakamasu, Yuma;
Nakamura, Kiseki;
Oda, Makoto;
Parker, Joseph D.;
Sawano, Tatsuya;
Sonoda, Shinya;
Tanimori, Toru;
Tomono, Dai;
Yoshikawa, Kei
Submitted: 2017-03-22
X-ray and gamma-ray polarimetry is a promising tool to study the geometry and
the magnetic configuration of various celestial objects, such as binary black
holes or gamma-ray bursts (GRBs). However, statistically significant
polarizations have been detected in few of the brightest objects. Even though
future polarimeters using X-ray telescopes are expected to observe weak
persistent sources, there are no effective approaches to survey transient and
serendipitous sources with a wide field of view (FoV). Here we present an
electron-tracking Compton camera (ETCC) as a highly-sensitive gamma-ray imaging
polarimeter. The ETCC provides powerful background rejection and a high
modulation factor over a FoV of up to 2$\pi$ sr thanks to its excellent imaging
based on a well-defined point spread function. Importantly, we demonstrated for
the first time the stability of the modulation factor under realistic
conditions of off-axis incidence and huge backgrounds using the SPring-8
polarized X-ray beam. The measured modulation factor of the ETCC was 0.65 $\pm$
0.01 at 150 keV for an off-axis incidence with an oblique angle of 30$^\circ$
and was not degraded compared to the 0.58 $\pm$ 0.02 at 130 keV for on-axis
incidence. These measured results are consistent with the simulation results.
Consequently, we found that the satellite-ETCC proposed in Tanimori et al.
(2015) would provide all-sky surveys of weak persistent sources of 13 mCrab
with 10% polarization for a 10$^{7}$ s exposure and over 20 GRBs down to a
$6\times10^{-6}$ erg cm$^{-2}$ fluence and 10% polarization during a one-year
observation.
[4]
oai:arXiv.org:1702.01483 [pdf] - 1535425
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on
Geometrical Optics
Tanimori, Toru;
Mizumura, Yoshitaka;
Takada, Atsushi;
Miyamoto, Shohei;
Takemura, Taito;
Kishimoto, Tetsuro;
Komura, Shotaro;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Matsuoka, Yoshihiro;
Miuchi, Kentaro;
Mizumoto, Tetsuya;
Nakamasu, Yuma;
Nakamura, Kiseki;
Parker, Joseph D.;
Sawano, Tatsuya;
Sonoda, Shinya;
Tomono, Dai;
Yoshikawa, Kei
Submitted: 2017-02-05
Since the discovery of nuclear gamma-rays, its imaging has been limited to
pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does
not keep physical information (intensity, or brightness in Optics) along a ray,
and thus is capable of no more than qualitative imaging of bright objects. To
attain quantitative imaging, cameras that realize geometrical optics is
essential, which would be, for nuclear MeV gammas, only possible via complete
reconstruction of the Compton process. Recently we have revealed that "Electron
Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function
(PSF). The information of an incoming gamma is kept along a ray with the PSF
and that is equivalent to geometrical optics. Here we present an
imaging-spectroscopic measurement with the ETCC. Our results highlight the
intrinsic difficulty with CCs in performing accurate imaging, and show that the
ETCC surmounts this problem. The imaging capability also helps the ETCC
suppress the noise level dramatically by ~3 orders of magnitude without a
shielding structure. Furthermore, full reconstruction of Compton process with
the ETCC provides spectra free of Compton edges. These results mark the first
proper imaging of nuclear gammas based on the genuine geometrical optics.
[5]
oai:arXiv.org:1610.02396 [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Battat, J. B. R.;
Irastorza, I. G.;
Aleksandrov, A.;
Guler, M. Ali;
Asada, T.;
Baracchini, E.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Buonaura, A.;
Burdge, K.;
Cebrian, S.;
Colas, P.;
Consiglio, L.;
Dafni, T.;
D'Ambrosio, N.;
Deaconu, C.;
De Lellis, G.;
Descombes, T.;
Di Crescenzo, A.;
Di Marco, N.;
Druitt, G.;
Eggleston, R.;
Ferrer-Ribas, E.;
Fusayasu, T.;
Galan, J.;
Galati, G.;
Garcia, J. A.;
Garza, J. G.;
Gentile, V.;
Garcia-Sciveres, M.;
Giomataris, Y.;
Guerrero, N.;
Guillaudin, O.;
Harton, J.;
Hashimoto, T.;
Hedges, M. T.;
Iguaz, F.;
Ikeda, T.;
Jaegle, I.;
Kadyk, J. A.;
Katsuragawa, T.;
Komura, S.;
Kubo, H.;
Kuge, K.;
Lamblin, J.;
Lauria, A.;
Lee, E. R.;
Lewis, P.;
Leyton, M.;
Loomba, D.;
Lopez, J. P.;
Luzon, G.;
Mayet, F.;
Mirallas, H.;
Miuchi, K.;
Mizumoto, T.;
Mizumura, Y.;
Monacelli, P.;
Monroe, J.;
Montesi, M. C.;
Naka, T.;
Nakamura, K.;
Nishimura, H.;
Ochi, A.;
Papevangelou, T.;
Parker, J. D.;
Phan, N. S.;
Pupilli, F.;
Richer, J. P.;
Riffard, Q.;
Rosa, G.;
Santos, D.;
Sawano, T.;
Sekiya, H.;
Seong, I. S.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Taishaku, R.;
Takada, A.;
Takeda, A.;
Tanaka, M.;
Tanimori, T.;
Thorpe, T. N.;
Tioukov, V.;
Tomita, H.;
Umemoto, A.;
Vahsen, S. E.;
Yamaguchi, Y.;
Yoshimoto, M.;
Zayas, E.
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
[6]
oai:arXiv.org:1607.06191 [pdf] - 1849127
Development of wide-field low-energy X-ray imaging detectors for
HiZ-GUNDAM
Yoshida, Kazuki;
Yonetoku, Daisuke;
Sawano, Tatsuya;
Ikeda, Hirokazu;
Harayama, Atsushi;
Arimoto, Makoto;
Kagawa, Yasuaki;
Ina, Masao;
Hatori, Satoshi;
Kume, Kyo;
Mizushima, Satoshi;
Hasegawa, Takashi
Submitted: 2016-07-21
We are planning a future gamma-ray burst (GRB) mission HiZ-GUNDAM to probe
the early universe beyond the redshift of z > 7. Now we are developing a small
prototype model of wide-field low-energy X-ray imaging detectors to observe
high-z GRBs, which cover the energy range of 1 - 20 keV. In this paper, we
report overview of its prototype system and performance, especially focusing on
the characteristics and radiation tolerance of high gain analog ASIC
specifically designed to read out small charge signals.
[7]
oai:arXiv.org:1506.02359 [pdf] - 1318051
X-raying extended emission and rapid decay of short gamma-ray bursts
Submitted: 2015-06-08, last modified: 2015-11-27
Extended emission is a mystery in short gamma-ray bursts (SGRBs). By making
time resolved spectral analyses of brightest nine events observed by ${\it
Swift}$ XRT, we obviously classify the early X-ray emission of SGRBs into two
types. One is the extended emission with exponentially rapid decay, which shows
significant spectral softening during hundreds seconds since the SGRB trigger
and is also detected by ${\it Swift}$-BAT. The other is a dim afterglow only
showing power-law decay over $10^4$ s. The correlations between the temporal
decay and spectral indices of the extended emissions are inconsistent with the
$\alpha$-$\beta$ correlation expected for the high-latitude curvature emission
from a uniform jet. The observed too-rapid decay suggests the emission from a
photosphere or a patchy surface, and manifests the stopping central engine via
such as magnetic reconnection at the black hole.
[8]
oai:arXiv.org:1508.00990 [pdf] - 1268655
New readout and data-acquisition system in an electron-tracking Compton
camera for MeV gamma-ray astronomy (SMILE-II)
Mizumoto, Tetsuya;
Matsuoka, Yoshihiro;
Mizumura, Yoshitaka;
Tanimori, Toru;
Kubo, Hidetoshi;
Takada, Atsushi;
Iwaki, Satoru;
Sawano, Tatsuya;
Nakamura, Kiseki;
Komura, Shotaro;
Nakamura, Shogo;
Kishimoto, Tetsuro;
Oda, Makoto;
Miyamoto, Shohei;
Takemura, Taito;
Parker, Joseph D.;
Tomono, Dai;
Sonoda, Shinya;
Miuchi, Kentaro;
Kurosawa, Shunsuke
Submitted: 2015-08-05, last modified: 2015-08-29
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton
camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation
background and attaining the high sensitivity of near 1 mCrab in space. Our
ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas
detector for tracking recoil electrons and a position-sensitive scintillation
camera for detecting scattered gamma rays. After the success of a first balloon
experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$
TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV
gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$
medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial
sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II).
To achieve this goal, a 100-times-larger detection area compared with that of
SMILE-I is required without changing the weight or power consumption of the
detector system. In addition, the event rate is also expected to dramatically
increase during observation. Here, we describe both the concept and the
performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to
manage 100 times more data while satisfying the severe restrictions regarding
the weight and power consumption imposed by a balloon-borne observation. In
particular, to improve the detection efficiency of the fine tracks in the TPC
from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in
the TPC. Therefore, for efficient management of such large amounts of data, we
developed a data-acquisition system with parallel data flow.
[9]
oai:arXiv.org:1508.01287 [pdf] - 1259555
A performance study of an electron-tracking Compton camera with a
compact system for environmental gamma-ray observation
Mizumoto, Tetsuya;
Tomono, Dai;
Takada, Atsushi;
Tanimori, Toru;
Komura, Shotaro;
Kubo, Hidetoshi;
Matsuoka, Yoshihiro;
Mizumura, Yoshitaka;
Nakamura, Kiseki;
Nakamura, Shogo;
Oda, Makoto;
Parker, Joseph D.;
Sawano, Tatsuya;
Bando, Naoto;
Nabetani, Akira
Submitted: 2015-08-06
An electron-tracking Compton camera (ETCC) is a detector that can determine
the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an
event-by-event basis. It is a hybrid detector consisting of a gaseous time
projection chamber (TPC), that is the Compton-scattering target and the tracker
of recoil electrons, and a position-sensitive scintillation camera that absorbs
of the scattered gamma rays, to measure gamma rays in the environment from
contaminated soil. To measure of environmental gamma rays from soil
contaminated with radioactive cesium (Cs), we developed a portable
battery-powered ETCC system with a compact readout circuit and data-acquisition
system for the SMILE-II experiment. We checked the gamma-ray imaging ability
and ETCC performance in the laboratory by using several gamma-ray point
sources. The performance test indicates that the field of view (FoV) of the
detector is about 1$\;$sr and that the detection efficiency and angular
resolution for 662$\;$keV gamma rays from the center of the FoV is $(9.31 \pm
0.95) \times 10^{^-5}$ and $5.9^{\circ} \pm 0.6^{\circ}$, respectively.
Furthermore, the ETCC can detect 0.15$\;\mu\rm{Sv/h}$ from a $^{137}$Cs
gamma-ray source with a significance of 5$\sigma$ in 13 min in the laboratory.
In this paper, we report the specifications of the ETCC and the results of the
performance tests. Furthermore, we discuss its potential use for environmental
gamma-ray measurements.
[10]
oai:arXiv.org:1507.03850 [pdf] - 1267930
An Electron-Tracking Compton Telescope for a Survey of the Deep Universe
by MeV gamma-rays
Tanimori, T.;
Kubo, H.;
Takada, A.;
Iwaki, S.;
Komura, S.;
Kurosawa, S.;
Matsuoka, Y.;
Miuchi, K.;
Miyamoto, S.;
Mizumoto, T.;
Mizumura, Y.;
Nakamura, K.;
Nakamura, S.;
Oda, M.;
Parker, J. D.;
Sawano, T.;
Sonoda, S.;
Takemura, T.;
Tomono, D.;
Ueno, K.
Submitted: 2015-07-14, last modified: 2015-08-04
Photon imaging for MeV gammas has serious difficulties due to huge
backgrounds and unclearness in images, which are originated from incompleteness
in determining the physical parameters of Compton scattering in detection,
e.g., lack of the directional information of the recoil electrons. The recent
major mission/instrument in the MeV band, Compton Gamma Ray
Observatory/COMPTEL, which was Compton Camera (CC), detected mere $\sim30$
persistent sources. It is in stark contrast with $\sim$2000 sources in the GeV
band. Here we report the performance of an Electron-Tracking Compton Camera
(ETCC), and prove that it has a good potential to break through this stagnation
in MeV gamma-ray astronomy. The ETCC provides all the parameters of
Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter
Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx),
which CCs cannot measure, is also obtained, and is found to be indeed helpful
to reduce the background under conditions similar to space. Accordingly the
significance in gamma detection is improved severalfold. On the other hand, SPD
is essential to determine the point-spread function (PSF) quantitatively. The
SPD resolution is improved close to the theoretical limit for multiple
scattering of recoil electrons. With such a well-determined PSF, we demonstrate
for the first time that it is possible to provide reliable sensitivity in
Compton imaging without utilizing an optimization algorithm. As such, this
study highlights the fundamental weak-points of CCs. In contrast we demonstrate
the possibility of ETCC reaching the sensitivity below $1\times10^{-12}$ erg
cm$^{-2}$ s$^{-1}$ at 1 MeV.
[11]
oai:arXiv.org:1412.3918 [pdf] - 1223621
Performance of a new electron-tracking Compton camera under intense
radiations from a water target irradiated with a proton beam
Matsuoka, Yoshihiro;
Tanimori, T.;
Kubo, H.;
Takada, A.;
Parker, J. D.;
Mizumoto, T.;
Mizumura, Y.;
Iwaki, S.;
Sawano, T.;
Komura, S.;
Kishimoto, T.;
Oda, M.;
Takemura, T.;
Miyamoto, S.;
Sonoda, S.;
Tomono, D.;
Miuchi, K.;
Kabuki, S.;
Kurosawa, S.
Submitted: 2014-12-12, last modified: 2015-01-22
We have developed an electron-tracking Compton camera (ETCC) for use in
next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time
projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC
measures the three dimensional tracks of Compton-recoil electrons, the ETCC can
completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates
efficient background rejection power in Compton-kinematics tests, identifies
particle from the energy deposit rate (dE/dX) registered in the TPC, and
provides high quality imaging by completely reconstructing the Compton
scattering process. We are planning the "Sub-MeV gamma ray Imaging
Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey
satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for
observing the Crab nebula, are ongoing. However, observations at balloon
altitudes or satellite orbits are obstructed by radiation background from the
atmosphere and the detector itself. The background rejection power was checked
using proton accelerator experiments conducted at the Research Center for
Nuclear Physics, Osaka University. To create the intense radiation fields
encountered in space, which comprise gamma rays, neutrons, protons, and other
energetic entities, we irradiated a water target with a 140 MeV proton beam and
placed a SMILE-II ETCC near the target. In this situation, the counting rate
was five times than that expected at the balloon altitude. Nonetheless, the
ETCC stably operated and identified particles sufficiently to obtain a clear
gamma ray image of the checking source. Here, we report the performance of our
detector and demonstrate its effective background rejection based in electron
tracking experiments.
[12]
oai:arXiv.org:1406.4202 [pdf] - 1215007
High-z gamma-ray bursts for unraveling the dark ages mission HiZ-GUNDAM
Yonetoku, Daisuke;
Mihara, Tatehiro;
Sawano, Tatsuya;
Ikeda, Hirokazu;
Harayama, Atsushi;
Takata, Shunsuke;
Yoshida, Kazuki;
Seta, Hiroki;
Toyanago, Asuka;
Kagawa, Yasuaki;
Kawai, Kentaro;
Kawai, Nobuyuki;
Sakamoto, Takanori;
Serino, Motoko;
Kurosawa, Shunsuke;
Gunji, Shuichi;
Tanimori, Toru;
Murakami, Toshio;
Yatsu, Yoichi;
Yamaoka, Kazutaka;
Yoshida, Atsumasa;
Kawabata, Koji;
Matsumoto, Toshio;
Tsumura, Koji;
Matsuura, Shuji;
Shirahata, Mai;
Okita, Hirofumi;
Yanagisawa, Kensi;
Yoshida, Michitoshi;
Motohara, Kentaro;
group, HiZ-GUNDAM working
Submitted: 2014-06-16
We are now investigating and studying a small satellite mission HiZ-GUNDAM
for future observation of gamma-ray bursts (GRBs). The mission concept is to
probe "the end of dark ages and the dawn of formation of astronomical objects",
i.e. the physical condition of early universe beyond the redshift z > 7. We
will consider two kinds of mission payloads, (1) wide field X-ray imaging
detectors for GRB discovery, and (2) a near infrared telescope with 30 cm in
diameter to select the high-z GRB candidates effectively. In this paper, we
explain some requirements to promote the GRB cosmology based on the past
observations, and also introduce the mission concept of HiZ-GUNDAM and basic
development of X-ray imaging detectors.
[13]
oai:arXiv.org:1402.5463 [pdf] - 1347421
Short Gamma Ray Burst Formation Rate from BATSE data using E_p-L_p
correlation and the minimum gravitational wave event rate of coalescing
compact binary
Submitted: 2014-02-21, last modified: 2014-06-10
Using 72 Short Gamma Ray Bursts (SGRBs) with well determined spectral data
observed by BATSE, we determine their redshift and the luminosity by applying
$E_p$--$L_p$ correlation for SGRBs found by \cite{tsutsui13}. For 53 SGRBs with
the observed flux brighter than $4 \times 10^{-6}~{\rm erg~cm^{-2}s^{-1}}$, the
cumulative redshift distribution up to $z=1$ agrees well with that of 22 {\it
Swift}~SGRBs. This suggests that the redshift determination by the $E_p$--$L_p$
correlation for SGRBs works well. The minimum event rate at $z=0$ is estimated
as $\rho_{SGRB}(0) = 6.3_{-3.9}^{+3.1} \times 10^{-10}~{\rm
events~Mpc^{-3}yr^{-1}}$ so that the minimum beaming angle is
$0.6^\circ-7.8^\circ$ assuming the merging rate of $10^{-7}-4\times
10^{-6}~{\rm events~Mpc^{-3}yr^{-1}}$ suggested from the binary pulsar data.
Interestingly, this angle is consistent with that for SGRB130603B of $\sim
4^\circ-8^\circ$\citep{fong13b}. On the other hand, if we assume the beaming
angle of $\sim 6^\circ$ suggested from four SGRBs with the observed value of
beaming angle, the minimum event rate including off-axis SGRBs is estimated as
$\rho_{SGRB,all}^{min}(0)=1.15_{-0.71}^{+0.57}\times 10^{-7}~{\rm
events~Mpc^{-3}yr^{-1}}$. If SGRBs are induced by coalescence of binary neutron
stars (NSs) and/or black holes (BHs), this event rate leads to the minimum
gravitational-wave detection rate of $\rm 3.9_{-2.4}^{+1.9}
(152_{-94}^{+75})~events~y^{-1}$ for NS-NS (NS-BH) binary, respectively, by a
worldwide network with KAGRA, advanced-LIGO, advanced-Virgo, and GEO.
[14]
oai:arXiv.org:1312.0438 [pdf] - 829396
Development of a 30 cm-cube Electron-Tracking Compton Camera for the
SMILE-II Experiment
Mizumura, Y.;
Tanimori, T.;
Kubo, H.;
Takada, A.;
Parker, J. D.;
Mizumoto, T.;
Sonoda, S.;
Tomono, D.;
Sawano, T.;
Nakamura, K.;
Matsuoka, Y.;
Komura, S.;
Nakamura, S.;
Oda, M.;
Miuchi, K.;
Kabuki, S.;
Kishimoto, Y.;
Kurosawa, S.;
Iwaki, S.
Submitted: 2013-12-02, last modified: 2014-02-07
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed
the Electron-Tracking Compton Camera (ETCC), and carried out the first
performance test at room condition using several gamma-ray sources in the
sub-MeV energy band. Using a simple track analysis for a quick first test of
the performance, the gamma-ray imaging capability was demonstrated by clear
images and 5.3 degrees of angular resolution measure (ARM) measured at 662 keV.
As the greatest impact of this work, a gamma-ray detection efficiency on the
order of $10^{-4}$ was achieved at the sub-MeV gamma-ray band, which is one
order of magnitude higher than our previous experiment. This angular resolution
and detection efficiency enables us to detect the Crab Nebula at the 5 sigma
level with several hours observation at balloon altitude in middle latitude.
Furthermore, good consistency of efficiencies between this performance test and
simulation including only physical processes has a large importance; it means
we achieve nearly 100% detection of Compton recoil electrons. Thus, our
estimation of enhancements by upgrades of the detector is more dependable. We
are planning to confirm the imaging capability of the ETCC by observation of
celestial objects in the SMILE-II (Sub-MeV gamma ray Imaging Loaded-on-balloon
Experiment II). The SMILE-II and following SMILE-III project will be an
important key of sub-MeV/MeV gamma-ray astronomy.
[15]
oai:arXiv.org:1109.3099 [pdf] - 1084087
NEWAGE
Miuchi, Kentaro;
Nakamura, Kiseki;
Takada, Atsushi;
Iwaki, Satoshi;
Kubo, Hidetoshi;
Mizumoto, Tetsuya;
Nishimura, Hironobu;
Parker, Joseph;
Sawano, Tatsuya;
Tanimori, Toru;
Sekiya, Hiroyuki;
Takeda, Atsushi;
Fusayasu, Takahiro;
Sugiyama, Akira;
Tanaka, Manobu
Submitted: 2011-09-14, last modified: 2011-09-15
NEWAGE is a direction-sensitive dark matter search experiment with a gaseous
time-projection chamber. We improved the direction-sensitive dark matter limits
by our underground measurement. After the first underground run, we replaced
the detector components with radio-pure materials. We also studied the
possibilities of head-tail recognition of nuclear tracks in the surface
laboratory. For the future large volume detector, we are developing a pixel
ASIC named QPIX. In this paper, these recent R&D activities are described.
[16]
oai:arXiv.org:1002.1794 [pdf] - 1025066
First underground results with NEWAGE-0.3a direction-sensitive dark
matter detector
Miuchi, Kentaro;
Nishimura, Hironobu;
Hattori, Kaori;
Higashi, Naoki;
Ida, Chihiro;
Iwaki, Satoshi;
Kabuki, Shigeto;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Nakamura, Kiseki;
Parker, Joseph;
Sawano, Tatsuya;
Takahashi, Michiaki;
Tanimori, Toru;
Taniue, Kojiro;
Ueno, Kazuki;
Sekiya, Hiroyuki;
Takeda, Atsushi;
Tsuchiya, Ken'ichi;
Takada, Atsushi
Submitted: 2010-02-09
A direction-sensitive dark matter search experiment at Kamioka underground
laboratory with the NEWAGE-0.3a detector was performed. The NEWAGE- 0.3a
detector is a gaseous micro-time-projection chamber filled with CF4 gas at 152
Torr. The fiducial volume and target mass are 20*25*31 cm3 and 0.0115 kg,
respectively. With an exposure of 0.524 kgdays, improved spin-dependent weakly
interacting massive particle (WIMP)-proton cross section limits by a
direction-sensitive method were achieved including a new record of 5400 pb for
150 GeV/c2 WIMPs. We studied the remaining background and found that ambient
gamma-rays contributed about one-fifth of the remaining background and
radioactive contaminants inside the gas chamber contributed the rest.
[17]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.