sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Sawano, T.

Normalized to: Sawano, T.

17 article(s) in total. 223 co-authors, from 1 to 12 common article(s). Median position in authors list is 9,0.

[1]  oai:arXiv.org:1904.10775  [pdf] - 1898030
Exponentially Decaying Extended Emissions Following Short Gamma-Ray Bursts with Possible Luminosity -- E-folding Time Correlation
Comments: 22 pages, 6 figures, accepted for publication in ApJ
Submitted: 2019-04-24
The origin of extended emissions following prompt emissions of short gamma-ray bursts (SGRBs) is in mystery. The long-term activity of the extended emission is responsible for promising electromagnetic counterparts to gravitational waves and, so that it may be a key to uncovering the progenitor of SGRBs. We investigate the early X-ray light curves of 26 SGRBs with known redshifts observed with the X-Ray Telescope aboard the {\it Neil Gehrels Swift Observatory} ({\it Swift}). We find that the exponential temporal decay model is able to describe the extended emissions comprehensively with a rest-frame e-folding time of 20 -- 200 seconds. We also estimate the isotropic equivalent energies of the extended emission with the exponential decay model and of the prompt emission, compared with those of the prompt emission. Then, it is revealed that the extended emission is 0 -- 3 orders of magnitude less powerful than the prompt emission. We find a strong correlation between the expected maximum luminosity and e-folding time which can be described by a power-law with an index of $-3.3$ and whose chance probability of $8.2\times10^{-6}$ if there is no observation bias of {\it Swift}. The exponential temporal decay may be interpreted to come from the spin-down time scale of the rotation energy of a highly magnetized neutron star, and/or fallback accretion onto a disk surrounding a black hole with an exponentially decaying magnetic flux by magnetic reconnection.
[2]  oai:arXiv.org:1903.05963  [pdf] - 1875381
Systematic study for gas-to-dust ratio of short gamma-ray burst afterglows
Comments: 15 pages, 4 figures
Submitted: 2019-03-14
Extra-galactic X-ray absorption and optical extinction are often found in gamma-ray burst (GRB) afterglows and they could be tracers of both circumburst and host galaxy environments. By performing spectral analyses for spectral energy distribution of 9 short GRB (SGRB) afterglows with known redshift, we investigated a ratio of the equivalent hydrogen column density to the dust extinction, N^{rest}_{H}/A^{rest}_{V}, in the rest frame of each SGRB. We found that the distribution of N^{rest}_{H}/A^{rest}_{V} is systematically smaller than the one for long GRBs, and is roughly consistent with the gas-to-dust ratio in the Milky Way. This result means that the measured gas-to-dust ratio of SGRBs would originate from the interstellar medium in each host galaxy. This scenario supports the prediction that SGRBs occur in non star-forming regions in the host galaxies.
[3]  oai:arXiv.org:1703.07600  [pdf] - 1564143
Imaging Polarimeter for a Sub-MeV Gamma-Ray All-Sky Survey using an Electron-Tracking Compton Camera
Comments: 22 pages, 19 figures, 1 table, accepted for publication in ApJ
Submitted: 2017-03-22
X-ray and gamma-ray polarimetry is a promising tool to study the geometry and the magnetic configuration of various celestial objects, such as binary black holes or gamma-ray bursts (GRBs). However, statistically significant polarizations have been detected in few of the brightest objects. Even though future polarimeters using X-ray telescopes are expected to observe weak persistent sources, there are no effective approaches to survey transient and serendipitous sources with a wide field of view (FoV). Here we present an electron-tracking Compton camera (ETCC) as a highly-sensitive gamma-ray imaging polarimeter. The ETCC provides powerful background rejection and a high modulation factor over a FoV of up to 2$\pi$ sr thanks to its excellent imaging based on a well-defined point spread function. Importantly, we demonstrated for the first time the stability of the modulation factor under realistic conditions of off-axis incidence and huge backgrounds using the SPring-8 polarized X-ray beam. The measured modulation factor of the ETCC was 0.65 $\pm$ 0.01 at 150 keV for an off-axis incidence with an oblique angle of 30$^\circ$ and was not degraded compared to the 0.58 $\pm$ 0.02 at 130 keV for on-axis incidence. These measured results are consistent with the simulation results. Consequently, we found that the satellite-ETCC proposed in Tanimori et al. (2015) would provide all-sky surveys of weak persistent sources of 13 mCrab with 10% polarization for a 10$^{7}$ s exposure and over 20 GRBs down to a $6\times10^{-6}$ erg cm$^{-2}$ fluence and 10% polarization during a one-year observation.
[4]  oai:arXiv.org:1702.01483  [pdf] - 1535425
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on Geometrical Optics
Comments: 22 pages, 8 figures
Submitted: 2017-02-05
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, which would be, for nuclear MeV gammas, only possible via complete reconstruction of the Compton process. Recently we have revealed that "Electron Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function (PSF). The information of an incoming gamma is kept along a ray with the PSF and that is equivalent to geometrical optics. Here we present an imaging-spectroscopic measurement with the ETCC. Our results highlight the intrinsic difficulty with CCs in performing accurate imaging, and show that the ETCC surmounts this problem. The imaging capability also helps the ETCC suppress the noise level dramatically by ~3 orders of magnitude without a shielding structure. Furthermore, full reconstruction of Compton process with the ETCC provides spectra free of Compton edges. These results mark the first proper imaging of nuclear gammas based on the genuine geometrical optics.
[5]  oai:arXiv.org:1610.02396  [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Comments: 58 pages, 26 figures, accepted by Physics Reports
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
[6]  oai:arXiv.org:1607.06191  [pdf] - 1849127
Development of wide-field low-energy X-ray imaging detectors for HiZ-GUNDAM
Comments: 11 pages, 8 figures, SPIE Astronomical Telescopes + Instrumentation (2016)
Submitted: 2016-07-21
We are planning a future gamma-ray burst (GRB) mission HiZ-GUNDAM to probe the early universe beyond the redshift of z > 7. Now we are developing a small prototype model of wide-field low-energy X-ray imaging detectors to observe high-z GRBs, which cover the energy range of 1 - 20 keV. In this paper, we report overview of its prototype system and performance, especially focusing on the characteristics and radiation tolerance of high gain analog ASIC specifically designed to read out small charge signals.
[7]  oai:arXiv.org:1506.02359  [pdf] - 1318051
X-raying extended emission and rapid decay of short gamma-ray bursts
Comments: 14 pages, 6 figures, 3 tables. Submitted to ApJ
Submitted: 2015-06-08, last modified: 2015-11-27
Extended emission is a mystery in short gamma-ray bursts (SGRBs). By making time resolved spectral analyses of brightest nine events observed by ${\it Swift}$ XRT, we obviously classify the early X-ray emission of SGRBs into two types. One is the extended emission with exponentially rapid decay, which shows significant spectral softening during hundreds seconds since the SGRB trigger and is also detected by ${\it Swift}$-BAT. The other is a dim afterglow only showing power-law decay over $10^4$ s. The correlations between the temporal decay and spectral indices of the extended emissions are inconsistent with the $\alpha$-$\beta$ correlation expected for the high-latitude curvature emission from a uniform jet. The observed too-rapid decay suggests the emission from a photosphere or a patchy surface, and manifests the stopping central engine via such as magnetic reconnection at the black hole.
[8]  oai:arXiv.org:1508.00990  [pdf] - 1268655
New readout and data-acquisition system in an electron-tracking Compton camera for MeV gamma-ray astronomy (SMILE-II)
Comments: 11 pages, 24 figures
Submitted: 2015-08-05, last modified: 2015-08-29
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for detecting scattered gamma rays. After the success of a first balloon experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$ TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$ medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II). To achieve this goal, a 100-times-larger detection area compared with that of SMILE-I is required without changing the weight or power consumption of the detector system. In addition, the event rate is also expected to dramatically increase during observation. Here, we describe both the concept and the performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to manage 100 times more data while satisfying the severe restrictions regarding the weight and power consumption imposed by a balloon-borne observation. In particular, to improve the detection efficiency of the fine tracks in the TPC from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in the TPC. Therefore, for efficient management of such large amounts of data, we developed a data-acquisition system with parallel data flow.
[9]  oai:arXiv.org:1508.01287  [pdf] - 1259555
A performance study of an electron-tracking Compton camera with a compact system for environmental gamma-ray observation
Comments: 10 pages, 7 figures, proceeding of the 10th International Conference on Position Sensitive Detectors (PSD10)
Submitted: 2015-08-06
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the scattered gamma rays, to measure gamma rays in the environment from contaminated soil. To measure of environmental gamma rays from soil contaminated with radioactive cesium (Cs), we developed a portable battery-powered ETCC system with a compact readout circuit and data-acquisition system for the SMILE-II experiment. We checked the gamma-ray imaging ability and ETCC performance in the laboratory by using several gamma-ray point sources. The performance test indicates that the field of view (FoV) of the detector is about 1$\;$sr and that the detection efficiency and angular resolution for 662$\;$keV gamma rays from the center of the FoV is $(9.31 \pm 0.95) \times 10^{^-5}$ and $5.9^{\circ} \pm 0.6^{\circ}$, respectively. Furthermore, the ETCC can detect 0.15$\;\mu\rm{Sv/h}$ from a $^{137}$Cs gamma-ray source with a significance of 5$\sigma$ in 13 min in the laboratory. In this paper, we report the specifications of the ETCC and the results of the performance tests. Furthermore, we discuss its potential use for environmental gamma-ray measurements.
[10]  oai:arXiv.org:1507.03850  [pdf] - 1267930
An Electron-Tracking Compton Telescope for a Survey of the Deep Universe by MeV gamma-rays
Comments: 19 pages, 12 figures, Accepted to the Astrophysical Journal
Submitted: 2015-07-14, last modified: 2015-08-04
Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which are originated from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton Camera (CC), detected mere $\sim30$ persistent sources. It is in stark contrast with $\sim$2000 sources in the GeV band. Here we report the performance of an Electron-Tracking Compton Camera (ETCC), and prove that it has a good potential to break through this stagnation in MeV gamma-ray astronomy. The ETCC provides all the parameters of Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx), which CCs cannot measure, is also obtained, and is found to be indeed helpful to reduce the background under conditions similar to space. Accordingly the significance in gamma detection is improved severalfold. On the other hand, SPD is essential to determine the point-spread function (PSF) quantitatively. The SPD resolution is improved close to the theoretical limit for multiple scattering of recoil electrons. With such a well-determined PSF, we demonstrate for the first time that it is possible to provide reliable sensitivity in Compton imaging without utilizing an optimization algorithm. As such, this study highlights the fundamental weak-points of CCs. In contrast we demonstrate the possibility of ETCC reaching the sensitivity below $1\times10^{-12}$ erg cm$^{-2}$ s$^{-1}$ at 1 MeV.
[11]  oai:arXiv.org:1412.3918  [pdf] - 1223621
Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam
Comments: 10 pages, 8figures, http://www-cr.scphys.kyoto-u.ac.jp/research/MeV-gamma/wiki/wiki.cgi , PSD10
Submitted: 2014-12-12, last modified: 2015-01-22
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient background rejection power in Compton-kinematics tests, identifies particle from the energy deposit rate (dE/dX) registered in the TPC, and provides high quality imaging by completely reconstructing the Compton scattering process. We are planning the "Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for observing the Crab nebula, are ongoing. However, observations at balloon altitudes or satellite orbits are obstructed by radiation background from the atmosphere and the detector itself. The background rejection power was checked using proton accelerator experiments conducted at the Research Center for Nuclear Physics, Osaka University. To create the intense radiation fields encountered in space, which comprise gamma rays, neutrons, protons, and other energetic entities, we irradiated a water target with a 140 MeV proton beam and placed a SMILE-II ETCC near the target. In this situation, the counting rate was five times than that expected at the balloon altitude. Nonetheless, the ETCC stably operated and identified particles sufficiently to obtain a clear gamma ray image of the checking source. Here, we report the performance of our detector and demonstrate its effective background rejection based in electron tracking experiments.
[12]  oai:arXiv.org:1406.4202  [pdf] - 1215007
High-z gamma-ray bursts for unraveling the dark ages mission HiZ-GUNDAM
Comments: 12 pages, 9 figures, SPIE Astronomical Telescopes + Instrumentation (2014)
Submitted: 2014-06-16
We are now investigating and studying a small satellite mission HiZ-GUNDAM for future observation of gamma-ray bursts (GRBs). The mission concept is to probe "the end of dark ages and the dawn of formation of astronomical objects", i.e. the physical condition of early universe beyond the redshift z > 7. We will consider two kinds of mission payloads, (1) wide field X-ray imaging detectors for GRB discovery, and (2) a near infrared telescope with 30 cm in diameter to select the high-z GRB candidates effectively. In this paper, we explain some requirements to promote the GRB cosmology based on the past observations, and also introduce the mission concept of HiZ-GUNDAM and basic development of X-ray imaging detectors.
[13]  oai:arXiv.org:1402.5463  [pdf] - 1347421
Short Gamma Ray Burst Formation Rate from BATSE data using E_p-L_p correlation and the minimum gravitational wave event rate of coalescing compact binary
Comments: 8 pages, 5 figures, accepted to ApJ
Submitted: 2014-02-21, last modified: 2014-06-10
Using 72 Short Gamma Ray Bursts (SGRBs) with well determined spectral data observed by BATSE, we determine their redshift and the luminosity by applying $E_p$--$L_p$ correlation for SGRBs found by \cite{tsutsui13}. For 53 SGRBs with the observed flux brighter than $4 \times 10^{-6}~{\rm erg~cm^{-2}s^{-1}}$, the cumulative redshift distribution up to $z=1$ agrees well with that of 22 {\it Swift}~SGRBs. This suggests that the redshift determination by the $E_p$--$L_p$ correlation for SGRBs works well. The minimum event rate at $z=0$ is estimated as $\rho_{SGRB}(0) = 6.3_{-3.9}^{+3.1} \times 10^{-10}~{\rm events~Mpc^{-3}yr^{-1}}$ so that the minimum beaming angle is $0.6^\circ-7.8^\circ$ assuming the merging rate of $10^{-7}-4\times 10^{-6}~{\rm events~Mpc^{-3}yr^{-1}}$ suggested from the binary pulsar data. Interestingly, this angle is consistent with that for SGRB130603B of $\sim 4^\circ-8^\circ$\citep{fong13b}. On the other hand, if we assume the beaming angle of $\sim 6^\circ$ suggested from four SGRBs with the observed value of beaming angle, the minimum event rate including off-axis SGRBs is estimated as $\rho_{SGRB,all}^{min}(0)=1.15_{-0.71}^{+0.57}\times 10^{-7}~{\rm events~Mpc^{-3}yr^{-1}}$. If SGRBs are induced by coalescence of binary neutron stars (NSs) and/or black holes (BHs), this event rate leads to the minimum gravitational-wave detection rate of $\rm 3.9_{-2.4}^{+1.9} (152_{-94}^{+75})~events~y^{-1}$ for NS-NS (NS-BH) binary, respectively, by a worldwide network with KAGRA, advanced-LIGO, advanced-Virgo, and GEO.
[14]  oai:arXiv.org:1312.0438  [pdf] - 829396
Development of a 30 cm-cube Electron-Tracking Compton Camera for the SMILE-II Experiment
Comments: 9 pages, 7 figures, Proceedings of the 15th International Workshop on Radiation Imaging Detectors (iWoRiD 2013)
Submitted: 2013-12-02, last modified: 2014-02-07
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of angular resolution measure (ARM) measured at 662 keV. As the greatest impact of this work, a gamma-ray detection efficiency on the order of $10^{-4}$ was achieved at the sub-MeV gamma-ray band, which is one order of magnitude higher than our previous experiment. This angular resolution and detection efficiency enables us to detect the Crab Nebula at the 5 sigma level with several hours observation at balloon altitude in middle latitude. Furthermore, good consistency of efficiencies between this performance test and simulation including only physical processes has a large importance; it means we achieve nearly 100% detection of Compton recoil electrons. Thus, our estimation of enhancements by upgrades of the detector is more dependable. We are planning to confirm the imaging capability of the ETCC by observation of celestial objects in the SMILE-II (Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment II). The SMILE-II and following SMILE-III project will be an important key of sub-MeV/MeV gamma-ray astronomy.
[15]  oai:arXiv.org:1109.3099  [pdf] - 1084087
NEWAGE
Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011
Submitted: 2011-09-14, last modified: 2011-09-15
NEWAGE is a direction-sensitive dark matter search experiment with a gaseous time-projection chamber. We improved the direction-sensitive dark matter limits by our underground measurement. After the first underground run, we replaced the detector components with radio-pure materials. We also studied the possibilities of head-tail recognition of nuclear tracks in the surface laboratory. For the future large volume detector, we are developing a pixel ASIC named QPIX. In this paper, these recent R&D activities are described.
[16]  oai:arXiv.org:1002.1794  [pdf] - 1025066
First underground results with NEWAGE-0.3a direction-sensitive dark matter detector
Comments: 21 pages, 8 figures, to appear in Physics Letters B
Submitted: 2010-02-09
A direction-sensitive dark matter search experiment at Kamioka underground laboratory with the NEWAGE-0.3a detector was performed. The NEWAGE- 0.3a detector is a gaseous micro-time-projection chamber filled with CF4 gas at 152 Torr. The fiducial volume and target mass are 20*25*31 cm3 and 0.0115 kg, respectively. With an exposure of 0.524 kgdays, improved spin-dependent weakly interacting massive particle (WIMP)-proton cross section limits by a direction-sensitive method were achieved including a new record of 5400 pb for 150 GeV/c2 WIMPs. We studied the remaining background and found that ambient gamma-rays contributed about one-fifth of the remaining background and radioactive contaminants inside the gas chamber contributed the rest.
[17]  oai:arXiv.org:0911.0323  [pdf] - 902277
The case for a directional dark matter detector and the status of current experimental efforts
Comments: 48 pages, 37 figures, whitepaper on direct dark matter detection with directional sensitivity
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.