Normalized to: Sauzet, N.
[1]
oai:arXiv.org:1903.02159 [pdf] - 2070434
Track length measurement of $^{19}$F$^+$ ions with the MIMAC Dark Matter
directional detector prototype
Tao, Y.;
Beaufort, C.;
Moric, I.;
Tao, C.;
Santos, D.;
Sauzet, N.;
Couturier, C.;
Guillaudin, O.;
Muraz, J. F.;
Naraghi, F.;
Zhou, N.;
Busto, J.
Submitted: 2019-03-05, last modified: 2020-03-26
Weakly Interacting Massive Particles (WIMPs) are one of the most preferred
candidate for Dark Matter. WIMPs should interact with the nuclei of detectors.
If a robust signal is eventually observed in direct detection experiments, the
best signature to confirm its Galactic origin would be the nuclear recoil track
direction. The MIMAC collaboration has developed a low pressure gas detector
providing both the kinetic energy and three-dimensional track reconstruction of
nuclear recoils. In this paper we report the first ever observations of
$^{19}$F nuclei tracks in a $5$ cm drift prototype MIMAC detector, in the low
kinetic energy range ($6$-$26$ keV), using specially developed ion beam
facilities. We have measured the recoil track lengths and found significant
differences between our measurements and standard simulations. In order to
understand these differences, we have performed a series of complementary
experiments and simulations to study the impact of the diffusion and eventual
systematics. We show an unexpected dependence of the number of read-out
corresponding to the track on the electric field applied to the $512\
\mathrm{\mu m}$ gap of the Micromegas detector. We have introduced, based on
the flash-ADC observable, corrections in order to reconstruct the physical 3D
track length of the primary electron clouds proposing the physics behind these
corrections. We show that diffusion and space charge effects need to be taken
into account to explain the differences between measurements and standard
simulations. These measurements and simulations may shed a new light on the
high-gain TPC ionization signals in general and particularly at low energy.
[2]
oai:arXiv.org:1711.07301 [pdf] - 1598281
Cathode signal in a TPC directional detector: implementation and
validation measuring the drift velocity
Submitted: 2017-11-20
Low-pressure gaseous TPCs are well suited detectors to correlate the
directions of nuclear recoils to the galactic Dark Matter (DM) halo. Indeed, in
addition to providing a measure of the energy deposition due to the elastic
scattering of a DM particle on a nucleus in the target gas, they allow for the
reconstruction of the track of the recoiling nucleus. In order to exclude the
background events originating from radioactive decays on the surfaces of the
detector materials within the drift volume, efforts are ongoing to precisely
localize the track nuclear recoil in the drift volume along the axis
perpendicular to the cathode plane. We report here the implementation of the
measure of the signal induced on the cathode by the motion of the primary
electrons toward the anode in a MIMAC chamber. As a validation, we performed an
independent measurement of the drift velocity of the electrons in the
considered gas mixture, correlating in time the cathode signal with the measure
of the arrival times of the electrons on the anode.
[3]
oai:arXiv.org:1607.08157 [pdf] - 1531131
Dark Matter directional detection: comparison of the track direction
determination
Submitted: 2016-07-27, last modified: 2017-01-16
Several directional techniques have been proposed for a directional detection
of Dark matter, among others anisotropic crystal detectors, nuclear emulsion
plates, and low-pressure gaseous TPCs. The key point is to get access to the
initial direction of the nucleus recoiling due to the elastic scattering by a
WIMP. In this article, we aim at estimating, for each method, how the
information of the recoil track initial direction is preserved in different
detector materials. We use the SRIM simulation code to emulate the motion of
the first recoiling nucleus in each material. We propose the use of a new
observable, D, to quantify the preservation of the initial direction of the
recoiling nucleus in the detector. We show that in an emulsion mix and an
anisotropic crystal, the initial direction is lost very early, while in a
typical TPC gas mix, the direction is well preserved.
[4]
oai:arXiv.org:1607.08765 [pdf] - 1446365
Directional detection of Dark Matter with the MIcro-tpc MAtrix of
Chambers
Couturier, C.;
Guillaudin, O.;
Naraghi, F.;
Riffard, Q.;
Santos, D.;
Sauzet, N.;
Colas, P.;
Ribas, E. Ferrer;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Tao, C.;
Zhou, N.
Submitted: 2016-07-29
Particles weakly interacting with ordinary matter, with an associated mass of
the order of an atomic nucleus (WIMPs), are plausible candidates for Dark
Matter. The direct detection of an elastic collision of a target nuclei induced
by one of these WIMPs has to be discriminated from the signal produced by the
neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc
MAtrix of Chambers) collaboration has developed an original prototype detector
which combines a large pixelated Micromegas coupled with a fast,
self-triggering, electronics. Aspects of the two-chamber module in operation in
the Modane Underground Laboratory are presented: calibration, characterization
of the $^{222}$Rn progeny. A new test bench combining a MIMAC chamber with the
COMIMAC portable quenching line has been set up to characterize the 3D tracks
of low energy ions in the MIMAC gas mixture: the preliminary results thereof
are presented. Future steps are briefly discussed.