sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Santorelli, R.

Normalized to: Santorelli, R.

32 article(s) in total. 652 co-authors, from 1 to 17 common article(s). Median position in authors list is 31,0.

[1]  oai:arXiv.org:2005.14667  [pdf] - 2105793
Constraints on dark matter-nucleon effective couplings in the presence of kinematically distinct halo substructures using the DEAP-3600 detector
Comments:
Submitted: 2020-05-29, last modified: 2020-06-01
DEAP-3600 is a single-phase liquid argon detector aiming to directly detect Weakly Interacting Massive Particles (WIMPs), located at SNOLAB (Sudbury, Canada). After analyzing data taken during the first year of operation, a null result was used to place an upper bound on the WIMP-nucleon spin-independent, isoscalar cross section. This study reinterprets this result within a Non-Relativistic Effective Field Theory framework, and further examines how various possible substructures in the local dark matter halo may affect these constraints. Such substructures are hinted at by kinematic structures in the local stellar distribution observed by the Gaia satellite and other recent astronomical surveys. These include the Gaia Sausage (or Enceladus), as well as a number of distinct streams identified in recent studies. Limits are presented for the coupling strength of the effective contact interaction operators $\mathcal{O}_1$, $\mathcal{O}_3$, $\mathcal{O}_5$, $\mathcal{O}_8$, and $\mathcal{O}_{11}$, considering isoscalar, isovector, and xenonphobic scenarios, as well as the specific operators corresponding to millicharge, magnetic dipole, electric dipole, and anapole interactions. The effects of halo substructures on each of these operators are explored as well, showing that the $\mathcal{O}_5$ and $\mathcal{O}_8$ operators are particularly sensitive to the velocity distribution, even at dark matter masses above 100 GeV/$c^2$.
[2]  oai:arXiv.org:2004.02024  [pdf] - 2075899
SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
The DarkSide collaboration; Aalseth, C. E.; Abdelhakim, S.; Agnes, P.; Ajaj, R.; Albuquerque, I. F. M.; Alexander, T.; Alici, A.; Alton, A. K.; Amaudruz, P.; Ameli, F.; Anstey, J.; Antonioli, P.; Arba, M.; Arcelli, S.; Ardito, R.; Arnquist, I. J.; Arpaia, P.; Asner, D. M.; Asunskis, A.; Ave, M.; Back, H. O.; Barbaryan, V.; Olmedo, A. Barrado; Batignani, G.; Bisogni, M. G.; Bocci, V.; Bondar, A.; Bonfini, G.; Bonivento, W.; Borisova, E.; Bottino, B.; Boulay, M. G.; Bunker, R.; Bussino, S.; Buzulutskov, A.; Cadeddu, M.; Cadoni, M.; Caminata, A.; Canci, N.; Candela, A.; Cantini, C.; Caravati, M.; Cariello, M.; Carnesecchi, F.; Castellani, A.; Castello, P.; Cavalcante, P.; Cavazza, D.; Cavuoti, S.; Cebrian, S.; Ruiz, J. M. Cela; Celano, B.; Cereseto, R.; Chashin, S.; Cheng, W.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Citterio, M.; Coccetti, F.; Cocco, V.; Colocci, M.; Vidal, E. Conde; Consiglio, L.; Cossio, F.; Covone, G.; Crivelli, P.; D'Antone, I.; D'Incecco, M.; Rolo, M. D. Da Rocha; Dadoun, O.; Daniel, M.; Davini, S.; De Cecco, S.; De Deo, M.; De Falco, A.; De Gruttola, D.; De Guido, G.; De Rosa, G.; Dellacasa, G.; Demontis, P.; De Pasquale, S.; Derbin, A. V.; Devoto, A.; Di Eusanio, F.; Di Noto, L.; Di Pietro, G.; Di Stefano, P.; Dionisi, C.; Dolganov, G.; Dordei, F.; Downing, M.; Edalatfar, F.; Empl, A.; Diaz, M. Fernandez; Filip, C.; Fiorillo, G.; Fomenko, K.; Franceschi, A.; Franco, D.; Frolov, E.; Froudakis, G. E.; Funicello, N.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Garbini, M.; Abia, P. Garcia; Fora, D. Gascón; Gendotti, A.; Ghiano, C.; Ghisi, A.; Giampa, P.; Giampaolo, R. A.; Giganti, C.; Giorgi, M. A.; Giovanetti, G. K.; Gligan, M. L.; Gorchakov, O.; Grab, M.; Diaz, R. Graciani; Grassi, M.; Grate, J. W.; Grobov, A.; Gromov, M.; Guan, M.; Guerra, M. B. B.; Guerzoni, M.; Gulino, M.; Haaland, R. K.; Hackett, B. R.; Hallin, A.; Haranczyk, M.; Harrop, B.; Hoppe, E. W.; Horikawa, S.; Hosseini, B.; Hubaut, F.; Humble, P.; Hungerford, E. V.; Ianni, An.; Ilyasov, A.; Ippolito, V.; Jillings, C.; Keeter, K.; Kendziora, C. L.; Kochanek, I.; Kondo, K.; Kopp, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kugathasan, R.; Kuss, M.; La Commara, M.; La Delfa, L.; Lai, M.; Lebois, M.; Lehnert, B.; Levashko, N.; Li, X.; Liqiang, Q.; Lissia, M.; Lodi, G. U.; Longo, G.; Lussana, R.; Luzzi, L.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Manecki, S.; Mapelli, L.; Margotti, A.; Mari, S. M.; Mariani, M.; Maricic, J.; Marinelli, M.; Marras, D.; Martínez, M.; Rojas, A. D. Martinez; Mascia, M.; Mason, J.; Masoni, A.; McDonald, A. B.; Messina, A.; Miletic, T.; Milincic, R.; Moggi, A.; Moioli, S.; Monroe, J.; Morrocchi, M.; Mroz, T.; Mu, W.; Muratova, V. N.; Murphy, S.; Muscas, C.; Musico, P.; Nania, R.; Napolitano, T.; Agasson, A. Navrer; Nessi, M.; Nikulin, I.; Nosov, V.; Nowak, J. A.; Oleinik, A.; Oleynikov, V.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Palmas, S.; Pandola, L.; Pantic, E.; Paoloni, E.; Pazzona, F.; Peeters, S.; Pegoraro, P. A.; Pelczar, K.; Pellegrini, L. A.; Pellegrino, C.; Pelliccia, N.; Perotti, F.; Pesudo, V.; Picciau, E.; Pietropaolo, F.; Pocar, A.; Pollmann, T. R.; Portaluppi, D.; Poudel, S. S.; Pralavorio, P.; Price, D.; Radics, B.; Raffaelli, F.; Ragusa, F.; Razeti, M.; Regenfus, C.; Renshaw, A. L.; Rescia, S.; Rescigno, M.; Retiere, F.; Rignanese, L. P.; Ripoli, C.; Rivetti, A.; Rode, J.; Romani, A.; Romero, L.; Rossi, N.; Rubbia, A.; Sala, P.; Salatino, P.; Samoylov, O.; García, E. Sánchez; Sandford, E.; Sanfilippo, S.; Sant, M.; Santone, D.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Scioli, G.; Segreto, E.; Seifert, A.; Semenov, D. A.; Shchagin, A.; Sheshukov, A.; Siddhanta, S.; Simeone, M.; Singh, P. N.; Skensved, P.; Skorokhvatov, M. D.; Smirnov, O.; Sobrero, G.; Sokolov, A.; Sotnikov, A.; Stainforth, R.; Steri, A.; Stracka, S.; Strickland, V.; Suffritti, G. B.; Sulis, S.; Suvorov, Y.; Szelc, A. M.; Tartaglia, R.; Testera, G.; Thorpe, T.; Tonazzo, A.; Tosi, A.; Tuveri, M.; Unzhakov, E. V.; Usai, G.; Vacca, A.; Vázquez-Jáuregui, E.; Viant, T.; Viel, S.; Villa, F.; Vishneva, A.; Vogelaar, R. B.; Wahl, J.; Walding, J. J.; Wang, H.; Wang, Y.; Westerdale, S.; Wheadon, R. J.; Williams, R.; Wilson, J.; Wojcik, Marcin; Wojcik, Mariusz; Wu, S.; Xiao, X.; Yang, C.; Ye, Z.; Zuffa, M.; Zuzel, G.
Comments: 25 pages, 22 figures, 3 tables
Submitted: 2020-04-04
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter search to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition to it, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) range. The first is due to bremsstrahlung of electrons scattered on neutral atoms (so-called neutral bremsstrahlung, NBrS). The second, responsible for electron avalanche scintillations in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a SiPM matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillations effects. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter search. It should be emphasized that this is the first practical application of the NBrS effect in detection science.
[3]  oai:arXiv.org:2001.08106  [pdf] - 2080977
Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon
The DarkSide Collaboration; Aalseth, C. E.; Abdelhakim, S.; Acerbi, F.; Agnes, P.; Ajaj, R.; Albuquerque, I. F. M.; Alexander, T.; Alici, A.; Alton, A. K.; Amaudruz, P.; Ameli, F.; Anstey, J.; Antonioli, P.; Arba, M.; Arcelli, S.; Ardito, R.; Arnquist, I. J.; Arpaia, P.; Asner, D. M.; Asunskis, A.; Ave, M.; Back, H. O.; Olmedo, A. Barrado; Batignani, G.; Bisogni, M. G.; Bocci, V.; Bondar, A.; Bonfini, G.; Bonivento, W.; Borisova, E.; Bottino, B.; Boulay, M. G.; Bunker, R.; Bussino, S.; Buzulutskov, A.; Cadeddu, M.; Cadoni, M.; Caminata, A.; Canci, N.; Candela, A.; Cantini, C.; Caravati, M.; Cariello, M.; Carnesecchi, F.; Carpinelli, M.; Castellani, A.; Castello, P.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Cavazza, D.; Cavuoti, S.; Cebrian, S.; Ruiz, J. M. Cela; Celano, B.; Cereseto, R.; Cheng, W.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Citterio, M.; Cocco, A. G.; Cocco, V.; Colocci, M.; Consiglio, L.; Cossio, F.; Covone, G.; Crivelli, P.; D'Antone, I.; D'Incecco, M.; D'Urso, D.; Rolo, M. D. Da Rocha; Dadoun, O.; Daniel, M.; Davini, S.; De Candia, A.; De Cecco, S.; De Deo, M.; De Falco, A.; De Filippis, G.; De Gruttola, D.; De Guido, G.; De Rosa, G.; Dellacasa, G.; Demontis, P.; DePaquale, S.; Derbin, A. V.; Devoto, A.; Di Eusanio, F.; Di Noto, L.; Di Pietro, G.; Di Stefano, P.; Dionisi, C.; Dolganov, G.; Dordei, F.; Downing, M.; Edalatfar, F.; Empl, A.; Diaz, M. Fernandez; Ferri, A.; Filip, C.; Fiorillo, G.; Fomenko, K.; Franceschi, A.; Franco, D.; Froudakis, G. E.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Abia, P. Garcia; Fora, D. Gascón; Gendotti, A.; Ghiano, C.; Ghisi, A.; Giagu, S.; Giampa, P.; Giampaolo, R. A.; Giganti, C.; Giorgi, M. A.; Giovanetti, G. K.; Gligan, M. L.; Gola, A.; Gorchakov, O.; Grab, M.; Diaz, R. Graciani; Granato, F.; Grassi, M.; Grate, J. W.; Grigoriev, G. Y.; Grobov, A.; Gromov, M.; Guan, M.; Guerra, M. B. B.; Guerzoni, M.; Gulino, M.; Haaland, R. K.; Hackett, B. R.; Hallin, A.; Harrop, B.; Hoppe, E. W.; Horikawa, S.; Hosseini, B.; Hubaut, F.; Humble, P.; Hungerford, E. V.; Ianni, An.; Ilyasov, A.; Ippolito, V.; Jillings, C.; Keeter, K.; Kendziora, C. L.; Kim, S.; Kochanek, I.; Kondo, K.; Kopp, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kugathasan, R.; Kuss, M.; Kuźniak, M.; La Commara, M.; La Delfa, L.; Lai, M.; Langrock, S.; Lebois, M.; Lehnert, B.; Levashko, N.; Li, X.; Liqiang, Q.; Lissia, M.; Lodi, G. U.; Longo, G.; Manzano, R. López; Lussana, R.; Luzzi, L.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Mapelli, L.; Marcante, M.; Margotti, A.; Mari, S. M.; Mariani, M.; Maricic, J.; Marinelli, M.; Marras, D.; Martínez, M.; Morales, J. J. Martínez; Rojas, A. D. Martinez; Martoff, C. J.; Mascia, M.; Mason, J.; Masoni, A.; Mazzi, A.; McDonald, A. B.; Messina, A.; Meyers, P. D.; Miletic, T.; Milincic, R.; Moggi, A.; Moioli, S.; Monroe, J.; Morrocchi, M.; Mroz, T.; Mu, W.; Muratova, V. N.; Murphy, S.; Muscas, C.; Musico, P.; Nania, R.; Napolitano, T.; Agasson, A. Navrer; Nessi, M.; Nikulin, I.; Oleinik, A.; Oleynikov, V.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Palmas, S.; Pandola, L.; Pantic, E.; Paoloni, E.; Paternoster, G.; Pavletcov, V.; Pazzona, F.; Peeters, S.; Pegoraro, P. A.; Pelczar, K.; Pellegrini, L. A.; Pellegrino, C.; Pelliccia, N.; Perotti, F.; Pesudo, V.; Picciau, E.; Piemonte, C.; Pietropaolo, F.; Pocar, A.; Pollman, T.; Portaluppi, D.; Poudel, S. S.; Pralavorio, P.; Price, D.; Radics, B.; Raffaelli, F.; Ragusa, F.; Razeti, M.; Razeto, A.; Regazzoni, V.; Regenfus, C.; Renshaw, A. L.; Rescia, S.; Rescigno, M.; Retiere, F.; Rignanese, L. P.; Rivetti, A.; Romani, A.; Romero, L.; Rossi, N.; Rubbia, A.; Sablone, D.; Sala, P.; Salatino, P.; Samoylov, O.; García, E. Sánchez; Sanfilippo, S.; Sant, M.; Santone, D.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Scioli, G.; Segreto, E.; Seifert, A.; Semenov, D. A.; Shchagin, A.; Sheshukov, A.; Siddhanta, S.; Simeone, M.; Singh, P. N.; Skensved, P.; Skorokhvatov, M. D.; Smirnov, O.; Sobrero, G.; Sokolov, A.; Sotnikov, A.; Stainforth, R.; Steri, A.; Stracka, S.; Strickland, V.; Suffritti, G. B.; Sulis, S.; Suvorov, Y.; Szelc, A. M.; Tartaglia, R.; Testera, G.; Thorpe, T.; Tonazzo, A.; Tosi, A.; Tuveri, M.; Unzhakov, E. V.; Usai, G.; Vacca, A.; Vázquez-Jáuregui, E.; Verducci, M.; Viant, T.; Viel, S.; Villa, F.; Vishneva, A.; Vogelaar, R. B.; Wada, M.; Wahl, J.; Walding, J. J.; Wang, H.; Wang, Y.; Westerdale, S.; Wheadon, R. J.; Williams, R.; Wilson, J.; Wojcik, Marcin; Wojcik, Mariusz; Wu, S.; Xiao, X.; Yang, C.; Ye, Z.; Zuffa, M.; Zuzel, G.
Comments: 13 pages, 8 figures. Corresponding author: E. S\'anchez Garc\'ia
Submitted: 2020-01-22
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $\beta$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $\gamma$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.
[4]  oai:arXiv.org:1902.05508  [pdf] - 1970174
Neutrino physics with the PTOLEMY project: active neutrino properties and the light sterile case
Comments: Typos corrected; Matches version accepted by JCAP
Submitted: 2019-02-14, last modified: 2019-09-30
The PTOLEMY project aims to develop a scalable design for a Cosmic Neutrino Background (CNB) detector, the first of its kind and the only one conceived that can look directly at the image of the Universe encoded in neutrino background produced in the first second after the Big Bang. The scope of the work for the next three years is to complete the conceptual design of this detector and to validate with direct measurements that the non-neutrino backgrounds are below the expected cosmological signal. In this paper we discuss in details the theoretical aspects of the experiment and its physics goals. In particular, we mainly address three issues. First we discuss the sensitivity of PTOLEMY to the standard neutrino mass scale. We then study the perspectives of the experiment to detect the CNB via neutrino capture on tritium as a function of the neutrino mass scale and the energy resolution of the apparatus. Finally, we consider an extra sterile neutrino with mass in the eV range, coupled to the active states via oscillations, which has been advocated in view of neutrino oscillation anomalies. This extra state would contribute to the tritium decay spectrum, and its properties, mass and mixing angle, could be studied by analyzing the features in the beta decay electron spectrum.
[5]  oai:arXiv.org:1905.05811  [pdf] - 1994027
Electromagnetic Backgrounds and Potassium-42 Activity in the DEAP-3600 Dark Matter Detector
Comments:
Submitted: 2019-05-14
The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB. The experimental signature of dark matter interactions is keV-scale $^{40}$Ar nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced by $\beta$ and $\gamma$-rays originating from internal and external radioactivity in the detector material. A background model of the ER interactions in DEAP-3600 was developed and is described in this work. The model is based on several components which are expected from radioisotopes in the LAr, from ex-situ material assay measurements, and from dedicated independent in-situ analyses. This prior information is used in a Bayesian fit of the ER components to a 247.2 d dataset to model the radioactivity in the surrounding detector materials. While excellent discrimination between ERs and NRs is reached with pulse shape discrimination, utilizing the large difference between fast and slow components of LAr scintillation light, detailed knowledge of the ER background and activity of detector components, sets valuable constraints on other key types of backgrounds in the detector: neutrons and alphas. In addition, the activity of $^{42}$Ar in LAr in DEAP-3600 is determined by measuring the daughter decay of $^{42}$K. This cosmogenically activated trace isotope is a relevant background at higher energies for other rare event searches using atmospheric argon e.g. DarkSide-20k, GERDA or LEGEND. The specific activity of $^{42}$Ar in the atmosphere is found to be $40.4 \pm 5.9$ $\mu$Bq/kg of argon.
[6]  oai:arXiv.org:1810.06703  [pdf] - 1875231
A Design for an Electromagnetic Filter for Precision Energy Measurements at the Tritium Endpoint
Comments:
Submitted: 2018-10-15
We present a detailed description of the electromagnetic filter for the PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB). Starting with an initial estimate for the orbital magnetic moment, the higher-order drift process of ExB is configured to balance the gradient-B drift motion of the electron in such a way as to guide the trajectory into the standing voltage potential along the mid-plane of the filter. As a function of drift distance along the length of the filter, the filter zooms in with exponentially increasing precision on the transverse velocity component of the electron kinetic energy. This yields a linear dimension for the total filter length that is exceptionally compact compared to previous techniques for electromagnetic filtering. The parallel velocity component of the electron kinetic energy oscillates in an electrostatic harmonic trap as the electron drifts along the length of the filter. An analysis of the phase-space volume conservation validates the expected behavior of the filter from the adiabatic invariance of the orbital magnetic moment and energy conservation following Liouville's theorem for Hamiltonian systems.
[7]  oai:arXiv.org:1802.06998  [pdf] - 1760983
Constraints on Sub-GeV Dark Matter-Electron Scattering from the DarkSide-50 Experiment
The DarkSide Collaboration; Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Araujo, G. R.; Asner, D. M.; Ave, M.; Back, H. O.; Baldin, B.; Batignani, G.; Biery, K.; Bocci, V.; Bonfini, G.; Bonivento, W.; Bottino, B.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadoni, M.; Calaprice, F.; Caminata, A.; Canci, N.; Candela, A.; Caravati, M.; Cariello, M.; Carlini, M.; Carpinelli, M.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Cavuoti, S.; Cereseto, R.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Cocco, A. G.; Covone, G.; D'Angelo, D.; D'Incecco, M.; D'Urso, D.; Davini, S.; De Candia, A.; De Cecco, S.; De Deo, M.; De Filippis, G.; De Rosa, G.; De Vincenzi, M.; Demontis, P.; Derbin, A. V.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Dionisi, C.; Downing, M.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Franco, D.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Abia, P. Garcia; Ghiano, C.; Giagu, S.; Giganti, C.; Giovanetti, G. K.; Gorchakov, O.; Goretti, A. M.; Granato, F.; Gromov, M.; Guan, M.; Guardincerri, Y.; Gulino, M.; Hackett, B. R.; Hassanshahi, M. H.; Herner, K.; Hosseini, B.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, Al.; Ianni, An.; Ippolito, V.; James, I.; Johnson, T. N.; Kahn, Y.; Keeter, K.; Kendziora, C. L.; Kochanek, I.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kuss, M.; La Commara, M.; Lai, M.; Li, X.; Lisanti, M.; Lissia, M.; Loer, B.; Longo, G.; Ma, Y.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Mapelli, L.; Mari, S. M.; Maricic, J.; Martoff, C. J.; Messina, A.; Meyers, P. D.; Milincic, R.; Mishra-Sharma, S.; Monte, A.; Morrocchi, M.; Mount, B. J.; Muratova, V. N.; Musico, P.; Nania, R.; Agasson, A. Navrer; Nozdrina, A. O.; Oleinik, A.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pandola, L.; Pantic, E.; Paoloni, E.; Pazzona, F.; Pelczar, K.; Pelliccia, N.; Pesudo, V.; Picciau, E.; Pocar, A.; Pordes, S.; Poudel, S. S.; Pugachev, D. A.; Qian, H.; Ragusa, F.; Razeti, M.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Riffard, Q.; Romani, A.; Rossi, B.; Rossi, N.; Sablone, D.; Samoylov, O.; Sands, W.; Sanfilippo, S.; Sant, M.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Segreto, E.; Semenov, D. A.; Shchagin, A.; Sheshukov, A.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Stracka, S.; Suffritti, G. B.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Verducci, M.; Vishneva, A.; Vogelaar, B.; Wada, M.; Waldrop, T. J.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wojcik, M. M.; Wojcik, M.; Xiang, X.; Xiao, X.; Yang, C.; Ye, Z.; Zhu, C.; Zichichi, A.; Zuzel, G.
Comments: replaced with published version
Submitted: 2018-02-20, last modified: 2018-10-03
We present new constraints on sub-GeV dark matter particles scattering off electrons in argon based on an analysis of ionization signal data from the DarkSide-50 detector.
[8]  oai:arXiv.org:1802.06994  [pdf] - 1739878
Low-Mass Dark Matter Search with the DarkSide-50 Experiment
The DarkSide Collaboration; Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Araujo, G. R.; Asner, D. M.; Ave, M.; Back, H. O.; Baldin, B.; Batignani, G.; Biery, K.; Bocci, V.; Bonfini, G.; Bonivento, W.; Bottino, B.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadoni, M.; Calaprice, F.; Caminata, A.; Canci, N.; Candela, A.; Caravati, M.; Cariello, M.; Carlini, M.; Carpinelli, M.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Cavuoti, S.; Cereseto, R.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Cocco, A. G.; Covone, G.; D'Angelo, D.; D'Incecco, M.; D'Urso, D.; Davini, S.; De Candia, A.; De Cecco, S.; De Deo, M.; De Filippis, G.; De Rosa, G.; De Vincenzi, M.; Demontis, P.; Derbin, A. V.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Dionisi, C.; Downing, M.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Franco, D.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Abia, P. Garcia; Ghiano, C.; Giagu, S.; Giganti, C.; Giovanetti, G. K.; Gorchakov, O.; Goretti, A. M.; Granato, F.; Gromov, M.; Guan, M.; Guardincerri, Y.; Gulino, M.; Hackett, B. R.; Hassanshahi, M. H.; Herner, K.; Hosseini, B.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, Al.; Ianni, An.; Ippolito, V.; James, I.; Johnson, T. N.; Kahn, Y.; Keeter, K.; Kendziora, C. L.; Kochanek, I.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kuss, M.; La Commara, M.; Lai, M.; Li, X.; Lisanti, M.; Lissia, M.; Loer, B.; Longo, G.; Ma, Y.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Mapelli, L.; Mari, S. M.; Maricic, J.; Martoff, C. J.; Messina, A.; Meyers, P. D.; Milincic, R.; Mishra-Sharma, S.; Monte, A.; Morrocchi, M.; Mount, B. J.; Muratova, V. N.; Musico, P.; Nania, R.; Agasson, A. Navrer; Nozdrina, A. O.; Oleinik, A.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pandola, L.; Pantic, E.; Paoloni, E.; Pazzona, F.; Pelczar, K.; Pelliccia, N.; Pesudo, V.; Pocar, A.; Pordes, S.; Poudel, S. S.; Pugachev, D. A.; Qian, H.; Ragusa, F.; Razeti, M.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Riffard, Q.; Romani, A.; Rossi, B.; Rossi, N.; Sablone, D.; Samoylov, O.; Sands, W.; Sanfilippo, S.; Sant, M.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Segreto, E.; Semenov, D. A.; Shchagin, A.; Sheshukov, A.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Stracka, S.; Suffritti, G. B.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Verducci, M.; Vishneva, A.; Vogelaar, B.; Wada, M.; Waldrop, T. J.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wojcik, M. M.; Wojcik, M.; Xiang, X.; Xiao, X.; Yang, C.; Ye, Z.; Zhu, C.; Zichichi, A.; Zuzel, G.
Comments: 9 pages, 8 figures; submission accepted by journal
Submitted: 2018-02-20, last modified: 2018-08-28
We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and is almost entirely accounted for by known background sources. We obtain a 90% C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section of dark matter WIMPs on nucleons, extending the exclusion region for dark matter below previous limits in the range 1.8-6 GeV/c^2.
[9]  oai:arXiv.org:1808.01892  [pdf] - 1728123
PTOLEMY: A Proposal for Thermal Relic Detection of Massive Neutrinos and Directional Detection of MeV Dark Matter
Comments:
Submitted: 2018-08-06
We propose to achieve the proof-of-principle of the PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB). Each of the technological challenges described in [1,2] will be targeted and hopefully solved by the use of the latest experimental developments and profiting from the low background environment provided by the LNGS underground site. The first phase will focus on the graphene technology for a tritium target and the demonstration of TES microcalorimetry with an energy resolution of better than 0.05 eV for low energy electrons. These technologies will be evaluated using the PTOLEMY prototype, proposed for underground installation, using precision HV controls to step down the kinematic energy of endpoint electrons to match the calorimeter dynamic range and rate capabilities. The second phase will produce a novel implementation of the EM filter that is scalable to the full target size and which demonstrates intrinsic triggering capability for selecting endpoint electrons. Concurrent with the CNB program, we plan to exploit and develop the unique properties of graphene to implement an intermediate program for direct directional detection of MeV dark matter [3,4]. This program will evaluate the radio-purity and scalability of the graphene fabrication process with the goal of using recently identified ultra-high radio-purity CO2 sources. The direct detection of the CNB is a snapshot of early universe dynamics recorded by the thermal relic neutrino yield taken at a time that predates the epochs of Big Bang Nucleosynthesis, the Cosmic Microwave Background and the recession of galaxies (Hubble Expansion). Big Bang neutrinos are believed to have a central role in the evolution of the Universe and a direct measurement with PTOLEMY will unequivocally establish the extent to which these predictions match present-day neutrino densities.
[10]  oai:arXiv.org:1712.07971  [pdf] - 1678506
Impact of the positive ion current on large size neutrino detectors and delayed photon emission
Comments: Proceedings of the Lidine 2017 conference
Submitted: 2017-12-21
Given their small mobility coefficient in liquid argon with respect to the electrons, the ions spend a considerably longer time in the active volume. We studied the effects of the positive ion current in a liquid argon time projection chamber, in the context of massive argon experiments for neutrino physics. The constant recombination between free ions and electrons produces a quenching of the charge signal and a constant emission of photons, uncorrelated in time and space to the physical interactions. The predictions evidence some potential concerns for multi-ton argon detectors, particularly when operated on surface
[11]  oai:arXiv.org:1712.01932  [pdf] - 1799803
Backgrounds and pulse shape discrimination in the ArDM liquid argon TPC
Comments: 17 pages, 10 figures
Submitted: 2017-12-02
The ArDM experiment completed a single-phase commissioning run in 2015 with an active liquid argon target of nearly one tonne in mass. The analysis of the data and comparison to simulations allowed for a test of the crucial detector properties and confirmed the low background performance of the setup. The statistical rejection power for electron recoil events using the pulse shape discrimination method was estimated using data from a Cf-252 neutron calibration source. Electron and nuclear recoil band profiles were found to be well described by Gaussian distributions. Employing such a model we derive values for the electron recoil statistical rejection power of more than 10$^8$ in the tonne-scale liquid argon target for events with more than 50 detected photons at a 50% acceptance for nuclear recoils. The Rn-222 emanation rate of the ArDM cryostat at room temperature was found to be 65.6$\pm$0.4 $\mu$Hz/l, and the Ar-39 specific activity from the employed atmospheric argon to be 0.95$\pm$0.05 Bq/kg. The cosmic muon flux at the Canfranc underground site was determined to be between 2 and 3.5$\times 10^{-3}m^{2}s^{-1}$ . These results pave the way for the next physics run of ArDM in the double-phase operational mode.
[12]  oai:arXiv.org:1612.06375  [pdf] - 1551971
The ArDM Liquid Argon Time Projection Chamber at the Canfranc Underground Laboratory: a ton-scale detector for Dark Matter Searches
Comments: 30 pages, 18 figures
Submitted: 2016-12-19
The Argon Dark Matter (ArDM) experiment consists of a liquid argon (LAr) time projection chamber (TPC) sensitive to nuclear recoils resulting from scattering of hypothetical Weakly Interacting Massive Particles (WIMPs) on argon targets. With an active target of 850 kg, ArDM represents an important milestone in the quest for Dark Matter with LAr. We present the experimental apparatus currently installed underground at the Laboratorio Subterraneo de Canfranc (LSC), Spain. We show first data recorded during a single-phase commissioning run in 2015 (ArDM Run I), which overall confirm the good and stable performance of the ton-scale LAr detector.
[13]  oai:arXiv.org:1611.02481  [pdf] - 1510448
Measurement of the attenuation length of argon scintillation light in the ArDM LAr TPC
Comments: 20 pages, 8 figures
Submitted: 2016-11-08
We report on a measurement of the attenuation length for the scintillation light in the tonne size liquid argon target of the ArDM dark matter experiment. The data was recorded in the first underground operation of the experiment in single-phase operational mode. The results were achieved by comparing the light yield spectra from 39-Ar and 83m-Kr to a description of the ArDM setup with a model of full light ray tracing. A relatively low value close to 0.5 m was found for the attenuation length of the liquid argon bulk to its own scintillation light. We interpret this result as a presence of optically active impurities in the liquid argon which are not filtered by the installed purification systems. We also present analyses of the argon gas employed for the filling and discuss cross sections in the vacuum ultraviolet of various molecules in respect to purity requirements in the context of large liquid argon installations.
[14]  oai:arXiv.org:1505.02443  [pdf] - 996764
Status of ArDM-1t: First observations from operation with a full ton-scale liquid argon target
Comments: 16 pages, 18 figures
Submitted: 2015-05-10
ArDM-1t is the first operating ton-scale liquid argon detector for direct search of Dark Matter particles. Developed at CERN as Recognized Experiment RE18, the experiment has been approved in 2010 to be installed in the Spanish underground site LSC (Laboratorio Subterraneo de Canfranc). Under the label of LSC EXP-08-2010 the ArDM detector underwent an intensive period of technical completion and safety approval until the recent filling of the target vessel with almost 2 ton of liquid argon. This report describes the experimental achievements during commissioning of ArDM and the transition into a stage of first physics data taking in single phase operational mode. We present preliminary observations from this run. A first indication for the background discrimination power of LAr detectors at the ton-scale is shown. We present an outlook for completing the detector with the electric drift field and upgrade of the scintillation light readout system with novel detector modules based on SiPMs in order to improve the light yield.
[15]  oai:arXiv.org:1104.3088  [pdf] - 661239
A search for light dark matter in XENON10 data
Comments: Manuscript identical to v2 (published version) but also contains erratum. Note v3==v2 but without \linenumbers
Submitted: 2011-04-15, last modified: 2013-05-07
We report results of a search for light (<10 GeV) particle dark matter with the XENON10 detector. The event trigger was sensitive to a single electron, with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear recoil energy. Considering spin-independent dark matter-nucleon scattering, we exclude cross sections \sigma_n>3.5x10^{-42} cm^2, for a dark matter particle mass m_{\chi}=8 GeV. We find that our data strongly constrain recent elastic dark matter interpretations of excess low-energy events observed by CoGeNT and CRESST-II, as well as the DAMA annual modulation signal.
[16]  oai:arXiv.org:1101.3866  [pdf] - 956174
Study of the electromagnetic background in the XENON100 experiment
Comments: 10 pages, 12 figures The updated version of the paper takes into account the new measurement of $^{136}$Xe 2$\nu$ $\beta\beta$ decay by EXO-200, with a half-life of (2.11$\pm0.04\pm$0.021)$\times10^{21}$ years
Submitted: 2011-01-20, last modified: 2013-02-21
The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We present a comprehensive study of the predicted electronic recoil background coming from radioactive decays inside the detector and shield materials, and intrinsic contamination. Based on GEANT4 Monte Carlo simulations using a detailed geometry together with the measured radioactivity of all detector components, we predict an electronic recoil background in the WIMP-search energy range (0-100 keV) in the 30 kg fiducial mass of less than 10e-2 events/(kg-day-keV), consistent with the experiment's design goal. The predicted background spectrum is in very good agreement with the data taken during the commissioning of the detector, in Fall 2009.
[17]  oai:arXiv.org:1107.2155  [pdf] - 474250
The XENON100 Dark Matter Experiment
Comments: 23 pages, 27 figures; version accepted by journal
Submitted: 2011-07-11, last modified: 2012-02-08
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time projection chamber (TPC) to search for Xe nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper we present a detailed description of the detector design and present performance results, as established during the commissioning phase and during the first science runs. The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating inside the liquid or in Xe gas. The LXe target and veto are contained in a low-radioactivity stainless steel vessel, embedded in a passive radiation shield. The experiment is installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy and has recently published results from a 100 live-days dark matter search. The ultimate design goal of XENON100 is to achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of \sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
[18]  oai:arXiv.org:1104.3121  [pdf] - 418418
Implications on Inelastic Dark Matter from 100 Live Days of XENON100 Data
Comments: 3 pages, 3 figures
Submitted: 2011-04-15, last modified: 2011-09-09
The XENON100 experiment has recently completed a dark matter run with 100.9 live-days of data, taken from January to June 2010. Events in a 48kg fiducial volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A total of three events have been found in the predefined signal region, compatible with the background prediction of (1.8 \pm 0.6) events. Based on this analysis we present limits on the WIMP-nucleon cross section for inelastic dark matter. With the present data we are able to rule out the explanation for the observed DAMA/LIBRA modulation as being due to inelastic dark matter scattering off iodine at a 90% confidence level.
[19]  oai:arXiv.org:1104.2549  [pdf] - 966664
Dark Matter Results from 100 Live Days of XENON100 Data
Comments: 5 pages, 5 figures; matches accepted version
Submitted: 2011-04-13, last modified: 2011-09-07
We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows to select only the innermost 48 kg as ultra-low background fiducial target. In 100.9 live days of data, acquired between January and June 2010, no evidence for dark matter is found. Three candidate events were observed in a pre-defined signal region with an expected background of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter interactions today, excluding spin-independent elastic WIMP-nucleon scattering cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90% confidence level.
[20]  oai:arXiv.org:1103.0303  [pdf] - 427646
Likelihood Approach to the First Dark Matter Results from XENON100
Comments: 8 pages, 6 figures, matches accepted version
Submitted: 2011-03-01, last modified: 2011-09-07
Many experiments that aim at the direct detection of Dark Matter are able to distinguish a dominant background from the expected feeble signals, based on some measured discrimination parameter. We develop a statistical model for such experiments using the Profile Likelihood ratio as a test statistic in a frequentist approach. We take data from calibrations as control measurements for signal and background, and the method allows the inclusion of data from Monte Carlo simulations. Systematic detector uncertainties, such as uncertainties in the energy scale, as well as astrophysical uncertainties, are included in the model. The statistical model can be used to either set an exclusion limit or to make a discovery claim, and the results are derived with a proper treatment of statistical and systematic uncertainties. We apply the model to the first data release of the XENON100 experiment, which allows to extract additional information from the data, and place stronger limits on the spin-independent elastic WIMP-nucleon scattering cross-section. In particular, we derive a single limit, including all relevant systematic uncertainties, with a minimum of 2.4x10^-44 cm^2 for WIMPs with a mass of 50 GeV/c^2.
[21]  oai:arXiv.org:1005.0380  [pdf] - 325339
First Dark Matter Results from the XENON100 Experiment
Comments: 5 pages, 5 figures. Matches published version
Submitted: 2010-05-03, last modified: 2011-03-01
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62 kg of liquid xenon in an ultra-low background dual-phase time projection chamber. In this letter, we present first dark matter results from the analysis of 11.17 live days of non-blind data, acquired in October and November 2009. In the selected fiducial target of 40 kg, and within the pre-defined signal region, we observe no events and hence exclude spin-independent WIMP-nucleon elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs at 90% confidence level. Below 20 GeV/c^2, this result constrains the interpretation of the CoGeNT and DAMA signals as being due to spin-independent, elastic, light mass WIMP interactions.
[22]  oai:arXiv.org:0910.3698  [pdf] - 270011
Constraints on inelastic dark matter from XENON10
Comments: 8 pages, 4 figures
Submitted: 2009-10-19, last modified: 2010-11-30
It has been suggested that dark matter particles which scatter inelastically from detector target nuclei could explain the apparent incompatibility of the DAMA modulation signal (interpreted as evidence for particle dark matter) with the null results from CDMS-II and XENON10. Among the predictions of inelastically interacting dark matter are a suppression of low-energy events, and a population of nuclear recoil events at higher nuclear recoil equivalent energies. This is in stark contrast to the well-known expectation of a falling exponential spectrum for the case of elastic interactions. We present a new analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV nuclear recoil equivalent energy. Our results exclude a significant region of previously allowed parameter space in the model of inelastically interacting dark matter. In particular, it is found that dark matter particle masses $m_{\chi}\gtrsim150$ GeV are disfavored.
[23]  oai:arXiv.org:1011.6439  [pdf] - 270289
Lowering the low-energy threshold of xenon detectors
Comments: Conference proceedings from the Identification of Dark Matter 2010, Montpellier, France. To be published by SISSA as PoS(IDM2010)017
Submitted: 2010-11-29
We show that the energy threshold for nuclear recoils in the XENON10 dark matter search data can be lowered to ~1 keV, by using only the ionization signal. In other words, we make no requirement that a valid event contain a primary scintillation signal. We therefore relinquish incident particle type discrimination, which is based on the ratio of ionization to scintillation in liquid xenon. This method compromises the detector's ability to precisely determine the z coordinate of a particle interaction. However, we show for the first time that it is possible to discriminate bulk events from surface events based solely on the ionization signal.
[24]  oai:arXiv.org:0908.0616  [pdf] - 205480
Spatially uniform calibration of a liquid xenon detector at low energies using 83m-Kr
Comments: 9 pages, 9 figures. Accepted to Review of Scientific Instruments
Submitted: 2009-08-05, last modified: 2010-05-16
A difficult task with many particle detectors focusing on interactions below ~100 keV is to perform a calibration in the appropriate energy range that adequately probes all regions of the detector. Because detector response can vary greatly in various locations within the device, a spatially uniform calibration is important. We present a new method for calibration of liquid xenon (LXe) detectors, using the short-lived 83m-Kr. This source has transitions at 9.4 and 32.1 keV, and as a noble gas like Xe, it disperses uniformly in all regions of the detector. Even for low source activities, the existence of the two transitions provides a method of identifying the decays that is free of background. We find that at decreasing energies, the LXe light yield increases, while the amount of electric field quenching is diminished. Additionally, we show that if any long-lived radioactive backgrounds are introduced by this method, they will present less than 67E-6 events/kg/day in the next generation of LXe dark matter direct detection searches
[25]  oai:arXiv.org:0810.0274  [pdf] - 166670
New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV
Comments: 8 pages, 8 figures
Submitted: 2008-10-01, last modified: 2010-05-16
Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative scintillation efficiency of nuclear recoils below 20 keV lead to inconsistent extrapolations at lower energies. This results in a different energy scale and thus sensitivity reach of liquid xenon dark matter detectors. We report a new measurement of the relative scintillation efficiency below 10 keV performed with a liquid xenon scintillation detector, optimized for maximum light collection. Greater than 95% of the interior surface of this detector was instrumented with photomultiplier tubes, giving a scintillation yield of 19.6 photoelectrons/keV electron equivalent for 122 keV gamma rays. We find that the relative scintillation efficiency for nuclear recoils of 5 keV is 0.14, staying constant around this value up to 10 keV. For higher energy recoils we measure a value around 20%, consistent with previously reported data. In light of this new measurement, the XENON10 experiment's results on spin-independent WIMP-nucleon cross section, which were calculated assuming a constant 0.19 relative scintillation efficiency, change from $8.8\times10^{-44}$ cm$^2$ to $9.9\times10^{-44}$ cm$^2$ for WIMPs of mass 100 GeV/c$^2$, and from $4.4\times10^{-44}$ cm$^2$ to $5.6\times10^{-44}$ cm$^2$ for WIMPs of mass 30 GeV/c$^2$.
[26]  oai:arXiv.org:1001.2834  [pdf] - 348097
Design and Performance of the XENON10 Dark Matter Experiment
Comments:
Submitted: 2010-01-16
XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground laboratory (LNGS) in Italy, and operated for more than one year, with excellent stability and performance. Results from a dark matter search with XENON10 have been published elsewhere. In this paper, we summarize the design and performance of the detector and its subsystems, based on calibration data using sources of gamma-rays and neutrons as well as background and Monte Carlo simulations data. The results on the detector's energy threshold, energy and position resolution, and overall efficiency show a performance that exceeds design specifications, in view of the very low energy threshold achieved (<10 keVr) and the excellent energy resolution achieved by combining the ionization and scintillation signals, detected simultaneously.
[27]  oai:arXiv.org:0807.0459  [pdf] - 1937508
The scintillation and ionization yield of liquid xenon for nuclear recoils
Comments: 8 pages, 9 figures. To be published in Nucl. Instrum. Methods A
Submitted: 2008-07-03, last modified: 2008-12-30
XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relative scintillation yield \leff and the absolute ionization yield Q_y, for nuclear recoils in xenon. A dark matter particle is expected to deposit energy by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for establishing the energy threshold of the experiment; this in turn determines the sensitivity to particle dark matter. Our \leff measurement is in agreement with recent theoretical predictions above 15 keV nuclear recoil energy, and the energy threshold of the measurement is 4 keV. A knowledge of the ionization yield \Qy is necessary to establish the trigger threshold of the experiment. The ionization yield \Qy is measured in two ways, both in agreement with previous measurements and with a factor of 10 lower energy threshold.
[28]  oai:arXiv.org:0805.2939  [pdf] - 1937505
Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10 experiment
Comments: 4 pages, 4 figures; final version published in PRL (added DAMA region to Figure 1)
Submitted: 2008-05-19, last modified: 2008-09-10
XENON10 is an experiment to directly detect weakly interacting massive particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter in our Universe. We report new results for spin-dependent WIMP-nucleon interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously unexplored regions in the theoretically allowed parameter space for neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its density and distribution in the galactic halo.
[29]  oai:arXiv.org:0706.0039  [pdf] - 1934124
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso National Laboratory
Comments: accepted for publication in Phys. Rev. Lett
Submitted: 2007-05-31, last modified: 2007-12-03
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg xenon dual phase time projection chamber (XeTPC) to search for dark matter weakly interacting massive particles (WIMPs). The detector measures simultaneously the scintillation and the ionization produced by radiation in pure liquid xenon, to discriminate signal from background down to 4.5 keV nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4 kg, excludes previously unexplored parameter space, setting a new 90% C.L. upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x 10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a WIMP mass of 30 GeV/c^2. This result further constrains predictions of supersymmetric models.
[30]  oai:arXiv.org:astro-ph/0603131  [pdf] - 80340
Measurement of the specific activity of Ar-39 in natural argon
Comments: 11 pages, 6 figures, to be submitted to Nucl. Instrum. Methods A
Submitted: 2006-03-06, last modified: 2007-01-10
We report on the measurement of the specific activity of Ar-39 in natural argon. The measurement was performed with a 2.3-liter two-phase (liquid and gas) argon drift chamber. The detector was developed by the WARP Collaboration as a prototype detector for WIMP Dark Matter searches with argon as a target. The detector was operated for more than two years at Laboratori Nazionali del Gran Sasso, Italy, at a depth of 3,400 m w.e. The specific activity measured for Ar-39 is 1.01 +/- 0.02(stat) +/- 0.08(syst) Bq per kg of natural Ar.
[31]  oai:arXiv.org:astro-ph/0411491  [pdf] - 1507895
WARP: a WIMP double phase Argon detector
Comments: Proceeding for IDM2004
Submitted: 2004-11-17
The WARP programme for dark matter search with a double phase argon detector is presented. In such a detector both excitation and ionization produced by an impinging particle are evaluated by the contemporary measurement of primary scintillation and secondary (proportional) light signal, this latter being produced by extracting and accelerating ionization electrons in the gas phase. The proposed technique, verified on a 2.3 liters prototype, could be used to efficiently discriminate nuclear recoils, induced by WIMP's interactions, and measure their energy spectrum. An overview of the 2.3 liters results and of the proposed 100 liters detector is shown.
[32]  oai:arXiv.org:astro-ph/0405342  [pdf] - 64862
WARP liquid argon detector for dark matter survey
Comments: Proceeding of the 6th UCLA Symposium on Sources and detection of Dark Matter and dark Energy in the Universe
Submitted: 2004-05-18
The WARP programme is a graded programme intended to search for cold Dark Matter in the form of WIMP's. These particles may produce via weak interactions nuclear recoils in the energy range 10-100 keV. A cryogenic noble liquid like argon, already used in the realization of very large detector, permits the simultaneous detection of both ionisation and scintillation induced by an interaction, suggesting the possibility of discriminating between nuclear recoils and electrons mediated events. A 2.3 litres two-phase argon detector prototype has been used to perform several tests on the proposed technique. Next step is the construction of a 100 litres sensitive volume device with potential sensitivity a factor 100 better than presently existing experiments.