Normalized to: Santarelli, G.
[1]
oai:arXiv.org:1104.4146 [pdf] - 511734
Ultra stable and very low noise signal source using a cryocooled
sapphire oscillator for VLBI
Submitted: 2011-04-20
Here we present the design and implementation of a novel frequency
synthesizer based on low phase noise digital dividers and a direct digital
synthesizer. The synthesis produces two low noise accurate and tunable signals
at 10 MHz and 100 MHz. We report on the measured residual phase noise and
frequency stability of the synthesizer, and estimate the total frequency
stability, which can be expected from the synthesizer seeded with a signal near
11.2 GHz from an ultra-stable cryocooled sapphire oscillator.
The synthesizer residual single sideband phase noise, at 1 Hz offset, on 10
MHz and 100 MHz signals, respectively, were measured to be -135 dBc/Hz and -130
dBc/Hz. Their intrinsic frequency stability contributions, on the 10 MHz and
100 MHz signals, respectively, were measured as sigma_y = 9 x 10^-15 and
sigma_y = 2.2 x 10^-15, at 1 s integration time.
The Allan Deviation of the total fractional frequency noise on the 10 MHz and
100 MHz signals derived from the synthesizer with the cryocooled sapphire
oscillator, may be estimated as sigma_y = 5.2 x 10^-15 \tau ^-1 + 3.6 x 10^-15
\tau ^-1/2 + 4 x 10^-16 and sigma_y = 2 x 10^-15 \tau ^-1/2 + 3 x 10^-16,
respectively, for 1 s < \tau < 10^4 s.
We also calculate the coherence function, (a figure of merit in VLBI) for
observation frequencies of 100 GHz, 230 GHz and 345 GHz, when using the
cryocooled sapphire oscillator and an hydrogen maser. The results show that the
cryocooled sapphire oscillator offers a significant advantage at frequencies
above 100 GHz.
[2]
oai:arXiv.org:0711.0304 [pdf] - 6649
Quantum Physics Exploring Gravity in the Outer Solar System: The Sagas
Project
Wolf, P.;
Bordé, Ch. J.;
Clairon, A.;
Duchayne, L.;
Landragin, A.;
Lemonde, P.;
Santarelli, G.;
Ertmer, W.;
Rasel, E.;
Cataliotti, F. S.;
Inguscio, M.;
Tino, G. M.;
Gill, P.;
Klein, H.;
Reynaud, S.;
Salomon, C.;
Peik, E.;
Bertolami, O.;
Gil, P.;
Páramos, J.;
Jentsch, C.;
Johann, U.;
Rathke, A.;
Bouyer, P.;
Cacciapuoti, L.;
Izzo, D.;
De Natale, P.;
Christophe, B.;
Touboul, P.;
Turyshev, S. G.;
Anderson, J. D.;
Tobar, M. E.;
Schmidt-Kaler, F.;
Vigué, J.;
Madej, A.;
Marmet, L.;
Angonin, M-C.;
Delva, P.;
Tourrenc, P.;
Metris, G.;
Müller, H.;
Walsworth, R.;
Lu, Z. H.;
Wang, L.;
Bongs, K.;
Toncelli, A.;
Tonelli, M.;
Dittus, H.;
Lämmerzahl, C.;
Galzerano, G.;
Laporta, P.;
Laskar, J.;
Fienga, A.;
Roques, F.;
Sengstock, K.
Submitted: 2007-11-02, last modified: 2008-08-12
We summarise the scientific and technological aspects of the SAGAS (Search
for Anomalous Gravitation using Atomic Sensors) project, submitted to ESA in
June 2007 in response to the Cosmic Vision 2015-2025 call for proposals. The
proposed mission aims at flying highly sensitive atomic sensors (optical clock,
cold atom accelerometer, optical link) on a Solar System escape trajectory in
the 2020 to 2030 time-frame. SAGAS has numerous science objectives in
fundamental physics and Solar System science, for example numerous tests of
general relativity and the exploration of the Kuiper belt. The combination of
highly sensitive atomic sensors and of the laser link well adapted for large
distances will allow measurements with unprecedented accuracy and on scales
never reached before. We present the proposed mission in some detail, with
particular emphasis on the science goals and associated measurements.
[3]
oai:arXiv.org:gr-qc/0401017 [pdf] - 111424
Whispering Gallery Resonators and Tests of Lorentz Invariance
Submitted: 2004-01-06, last modified: 2004-02-10
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are
compared to set new constraints on a possible violation of Lorentz invariance.
We give a detailed description of microwave resonators operating in Whispering
Gallery modes and then apply it to derive explicit models for Lorentz violating
effects in our experiment. Models are calculated in the theoretical framework
of Robertson, Mansouri and Sexl and in the standard model extension (SME) of
Kostelecky and co-workers. We constrain the parameters of the Mansouri and Sexl
test theory to $1/2 - \beta_{MS} + \delta_{MS} = (1.2 \pm 2.2) \times 10^{-9}$
and $\beta_{MS} - \alpha_{MS} - 1 = (1.6 \pm 3.0) \times 10^{-7}$ which is of
the same order as the best results from other experiments for the former and
represents a 70 fold improvement for the latter. These results correspond to an
improvement of our previously published limits [Wolf P. et al., Phys. Rev.
Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2.
[4]
oai:arXiv.org:astro-ph/0310112 [pdf] - 1591979
Cold Atom Clocks, Precision Oscillators and Fundamental Tests
Bize, S.;
Wolf, P.;
Abgrall, M.;
Cacciapuoti, L.;
Clairon, A.;
Gruenert, J.;
Laurent, Ph.;
Lemonde, P.;
Maksimovic, I.;
Mandache, C.;
Marion, H.;
Santos, F. Pereira Dos;
Rosenbusch, P.;
Santarelli, G.;
Sortais, Y.;
Vian, C.;
Zhang, S.;
Salomon, C.;
Luiten, A. N.;
Tobar, M. E.
Submitted: 2003-10-04
We describe two experimental tests of the Equivalence Principle that are
based on frequency measurements between precision oscillators and/or highly
accurate atomic frequency standards. Based on comparisons between the hyperfine
frequencies of 87Rb and 133Cs in atomic fountains, the first experiment
constrains the stability of fundamental constants. The second experiment is
based on a comparison between a cryogenic sapphire oscillator and a hydrogen
maser. It tests Local Lorentz Invariance. In both cases, we report recent
results which improve significantly over previous experiments.
[5]
oai:arXiv.org:gr-qc/0306047 [pdf] - 111265
Tests of Lorentz Invariance Using a Microwave Resonator: An Update
Submitted: 2003-06-11
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are
compared to set new constraints on a possible violation of Lorentz invariance.
We determine the variation of the oscillator frequency as a function of its
orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike
test) with respect to a preferred frame candidate. We constrain the
corresponding parameters of the Mansouri and Sexl test theory to $\delta -
\beta + 1/2 \leq 3.4 \times 10^{-9}$ and $\beta - \alpha - 1 \leq 4.1 \times
10^{-7}$ which is of the same order as the best previous result for the former
and represents a 50 fold improvement for the latter. These results correspond
to an improvement of our previously published limits [Wolf P. et al., Phys.
Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2. We describe the
changes of the experiment, and show the new data that lead to that improvement.
[6]
oai:arXiv.org:physics/0212112 [pdf] - 119004
A Search for Variations of Fundamental Constants using Atomic Fountain
Clocks
Marion, H.;
Santos, F. Pereira Dos;
Abgrall, M.;
Zhang, S.;
Sortais, Y.;
Bize, S.;
Maksimovic, I.;
Calonico, D.;
Gruenert, J.;
Mandache, C.;
Lemonde, P.;
Santarelli, G.;
Laurent, Ph.;
Clairon, A.;
Salomon, C.
Submitted: 2002-12-31
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb
atoms in their electronic ground state using several laser cooled 133Cs and
87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a
stringent upper bound to a possible fractional time variation of the ratio
between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16}
yr^{-1} (1 sigma uncertainty). The same limit applies to a possible variation
of the quantity (mu_Rb/mu_Cs)*alpha^{-0.44}, which involves the ratio of
nuclear magnetic moments and the fine structure constant.