sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Sansonetti, Craig J.

Normalized to: Sansonetti, C.

2 article(s) in total. 2 co-authors, from 1 to 2 common article(s). Median position in authors list is 2,5.

[1]  oai:arXiv.org:1308.5229  [pdf] - 1178752
The Spectrum of Thorium from 250 nm to 5500 nm: Ritz Wavelengths and Optimized Energy Levels
Comments: 15 pages, 8 figures, 7 tables. Revised to remove spurious lines in tables 1 and 6. Full versions of tables 1, 5, 6 and 7 uploaded as ancillary files
Submitted: 2013-08-23, last modified: 2014-01-23
We have made precise observations of a thorium-argon hollow cathode lamp emission spectrum in the region between 350 nm and 1175 nm using a high-resolution Fourier transform spectrometer. Our measurements are combined with results from seven previously published thorium line lists (Giacchetti et al. 1974; Zalubas & Corliss 1974; Zalubas 1976; Palmer & Engleman 1983; Engleman et al. 2003; Lovis & Pepe 2007; Kerber et al. 2008) to re-optimize the energy levels of neutral, singly-, and doubly-ionized thorium (Th I, Th II, and Th III). Using the optimized level values, we calculate accurate Ritz wavelengths for 19874 thorium lines between 250 nm and 5500 nm (40000 1/cm to 1800 1/cm). We have also found 102 new thorium energy levels. A systematic analysis of previous measurements in light of our new results allows us to identify and propose corrections for systematic errors in Palmer & Engleman (1983) and typographical errors and incorrect classifications in Kerber et al. (2008). We also found a large scatter in the thorium line list of Lovis & Pepe (2007). We anticipate that our Ritz wavelengths will lead to improved measurement accuracy for current and future spectrographs that make use of thorium-argon or thorium-neon lamps as calibration standards.
[2]  oai:arXiv.org:1101.4915  [pdf] - 1051677
Wavelengths of the 3d6(5D)4s a6D - 3d6(5D)4p y6P Multiplet of Fe II (UV 8)
Comments: 29 pages, 7 figures, 8 tables. Accepted for publication in J. Opt. Soc. Am B
Submitted: 2011-01-25
We investigate the wavenumber scale of Fe I and Fe II lines using new spectra recorded with Fourier transform spectroscopy and using a re-analysis of archival spectra. We find that standards in Ar II, Mg I, Mg II and Ge I give a consistent wavenumber calibration. We use the recalibrated spectra to derive accurate wavelengths for the a6D-y6P multiplet of Fe II (UV 8) using both directly measured lines and Ritz wavelengths. Lines from this multiplet are important for astronomical tests of the invariance of the fine structure constant on a cosmological time scale. We recommend a wavelength of 1608.45081 {\AA} with a one standard deviation uncertainty of 0.00007 {\AA} for the a6D9/2-y6P7/2 transition.