Sandimani, P. R.
Normalized to: Sandimani, P.
3 article(s) in total. 24 co-authors, from 1 to 3 common article(s). Median position in authors list is 7,0.
[1]
oai:arXiv.org:1802.05008 [pdf] - 1635418
TIFR Near Infrared Imaging Camera-II on the 3.6-m Devasthal Optical
Telescope
Baug, T.;
Ojha, D. K.;
Ghosh, S. K.;
Sharma, S.;
Pandey, A. K.;
Kumar, Brijesh;
Ghosh, Arpan;
Ninan, J. P.;
Naik, M. B.;
D'Costa, S. L. A.;
Poojary, S. S.;
Sandimani, P. R.;
Shah, H.;
Reddy, B. Krishna;
Pandey, S. B.;
Chand, H.
Submitted: 2018-02-14
TIFR Near Infrared Imaging Camera-II is a closed-cycle Helium cryo-cooled
imaging camera equipped with a Raytheon 512 x 512 pixels InSb Aladdin III
Quadrant focal plane array having sensitivity to photons in the 1-5 microns
wavelength band. In this paper, we present the performance of the camera on the
newly installed 3.6-m Devasthal Optical Telescope (DOT) based on the
calibration observations carried out during 2017 May 11-14 and 2017 October
7-31. After the preliminary characterization, the camera has been released to
the Indian and Belgian astronomical community for science observations since
2017 May. The camera offers a field-of-view of ~86.5 arcsec x 86.5 arcsec on
the DOT with a pixel scale of 0.169 arcsec. The seeing at the telescope site in
the near-infrared bands is typically sub-arcsecond with the best seeing of
~0.45 arcsec realized in the near-infrared K-band on 2017 October 16. The
camera is found to be capable of deep observations in the J, H and K bands
comparable to other 4-m class telescopes available world-wide. Another
highlight of this camera is the observational capability for sources up to
Wide-field Infrared Survey Explorer (WISE) W1-band (3.4 microns) magnitudes of
9.2 in the narrow L-band (nbL; lambda_{cen} ~3.59 microns). Hence, the camera
could be a good complementary instrument to observe the bright nbL-band sources
that are saturated in the Spitzer-Infrared Array Camera ([3.6] <= 7.92 mag) and
the WISE W1-band ([3.4] <= 8.1 mag). Sources with strong polycyclic aromatic
hydrocarbon (PAH) emission at 3.3 microns are also detected. Details of the
observations and estimated parameters are presented in this paper.
[2]
oai:arXiv.org:1408.4006 [pdf] - 863630
TIRSPEC : TIFR Near Infrared Spectrometer and Imager
Ninan, J. P.;
Ojha, D. K.;
Ghosh, S. K.;
D'Costa, S. L. A.;
Naik, M. B.;
Poojary, S. S.;
Sandimani, P. R.;
Meshram, G. S.;
Jadhav, R. B.;
Bhagat, S. B.;
Gharat, S. M.;
Bakalkar, C. B.;
Prabhu, T. P.;
Anupama, G. C.;
Toomey, D. W.
Submitted: 2014-08-18
We describe the TIFR Near Infrared Spectrometer and Imager (TIRSPEC) designed
and built in collaboration with M/s. Mauna Kea Infrared LLC, Hawaii, USA, now
in operation on the side port of the 2-m Himalayan Chandra Telescope (HCT),
Hanle (Ladakh), India at an altitude of 4500 meters above mean sea level. The
TIRSPEC provides for various modes of operation which include photometry with
broad and narrow band filters, spectrometry in single order mode with long
slits of 300" length and different widths, with order sorter filters in the Y,
J, H and K bands and a grism as the dispersing element as well as a cross
dispersed mode to give a coverage of 1.0 to 2.5 microns at a resolving power R
of ~1200. The TIRSPEC uses a Teledyne 1024 x 1024 pixel Hawaii-1 PACE array
detector with a cutoff wavelength of 2.5 microns and on HCT, provides a field
of view of 307" x 307" with a plate scale of 0.3"/pixel. The TIRSPEC was
successfully commissioned in June 2013 and the subsequent characterization and
astronomical observations are presented here. The TIRSPEC has been made
available to the worldwide astronomical community for science observations from
May 2014.
[3]
oai:arXiv.org:1211.5542 [pdf] - 594148
TIRCAM2: The TIFR Near Infrared Imaging Camera
Naik, M. B.;
Ojha, D. K.;
Ghosh, S. K.;
Poojary, S. S.;
Jadhav, R. B.;
Meshram, G. S.;
Sandimani, P. R.;
Bhagat, S. B.;
D'Costa, S. L. A.;
Gharat, S. M.;
Bakalkar, C. B.;
Ninan, J. P.;
Joshi, J. S.
Submitted: 2012-11-23
TIRCAM2 (TIFR Near Infrared Imaging Camera - II) is a closed cycle cooled
imager that has been developed by the Infrared Astronomy Group at the Tata
Institute of Fundamental Research for observations in the near infrared band of
1 to 3.7 microns with existing Indian telescopes. In this paper, we describe
some of the technical details of TIRCAM2 and report its observing capabilities,
measured performance and limiting magnitudes with the 2-m IUCAA Girawali
telescope and the 1.2-m PRL Gurushikhar telescope. The main highlight is the
camera's capability of observing in the nbL (3.59 microns) band enabling our
primary motivation of mapping of Polycyclic Aromatic Hydrocarbon (PAH) emission
at 3.3 microns.