Normalized to: Salmon, M.
[1]
oai:arXiv.org:1005.2541 [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument
flight model radiometers
Villa, F.;
Terenzi, L.;
Sandri, M.;
Meinhold, P.;
Poutanen, T.;
Battaglia, P.;
Franceschet, C.;
Hughes, N.;
Laaninen, M.;
Lapolla, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Balasini, M.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Cappellini, B.;
Cavaliere, F.;
Colin, A.;
Colombo, F.;
Davis, R. J.;
De La Fuente, L.;
Edgeley, J.;
Gaier, T.;
Galtress, A.;
Hoyland, R.;
Jukkala, P.;
Kettle, D.;
Kilpia, V-H.;
Lawrence, C. R.;
Lawson, D.;
Leahy, J. P.;
Leutenegger, P.;
Levin, S.;
Maino, D.;
Malaspina, M.;
Mediavilla, A.;
Miccolis, M.;
Pagan, L.;
Pascual, J. P.;
Pasian, F.;
Pecora, M.;
Pospieszalski, M.;
Roddis, N.;
Salmon, M. J.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Sozzi, C.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.
[2]
oai:arXiv.org:1001.4642 [pdf] - 33158
Off-line radiometric analysis of Planck/LFI data
Tomasi, M.;
Mennella, A.;
Galeotta, S.;
Lowe, S. R.;
Mendes, L.;
Leonardi, R.;
Villa, F.;
Cappellini, B.;
Gregorio, A.;
Meinhold, P.;
Sandri, M.;
Cuttaia, F.;
Terenzi, L.;
Maris, M.;
Valenziano, L.;
Salmon, M. J.;
Bersanelli, M.;
Binko, P.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Frailis, M.;
Franceschi, E.;
Gasparo, F.;
Maggio, G.;
Maino, D.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meharga, M.;
Morgante, G.;
Morisset, N.;
Pasian, F.;
Perrotta, F.;
Rohlfs, R.;
Turler, M.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) is an array of 22
pseudo-correlation radiometers on-board the Planck satellite to measure
temperature and polarization anisotropies in the Cosmic Microwave Background
(CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the
performances of the LFI, a software suite named LIFE has been developed. Its
aims are to provide a common platform to use for analyzing the results of the
tests performed on the single components of the instrument (RCAs, Radiometric
Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA).
Moreover, its analysis tools are designed to be used during the flight as well
to produce periodic reports on the status of the instrument. The LIFE suite has
been developed using a multi-layered, cross-platform approach. It implements a
number of analysis modules written in RSI IDL, each accessing the data through
a portable and heavily optimized library of functions written in C and C++. One
of the most important features of LIFE is its ability to run the same data
analysis codes both using ground test data and real flight data as input. The
LIFE software suite has been successfully used during the RCA/RAA tests and the
Planck Integrated System Tests. Moreover, the software has also passed the
verification for its in-flight use during the System Operations Verification
Tests, held in October 2008.
[3]
oai:arXiv.org:1001.4653 [pdf] - 33163
Thermal susceptibility of the Planck-LFI receivers
Terenzi, L;
Salmon, M J;
Colin, A;
Mennella, A;
Morgante, G;
Tomasi, M;
Battaglia, P;
Lapolla, M;
Bersanelli, M;
Butler, R C;
Cuttaia, F;
D'Arcangelo, O;
Davis, R;
Franceschet, C;
Galeotta, S;
Gregorio, A;
Hughes, N;
Jukkala, P;
Kettle, D;
Laaninen, M;
Leutenegger, P;
Leonardi, R;
Mandolesi, N;
Maris, M;
Meinhold, P;
Miccolis, M;
Roddis, N;
Sambo, L;
Sandri, M;
Silvestri, R;
Tuovinen, J;
Valenziano, L;
Varis, J;
Villa, F;
Wilkinson, A;
Zonca, A
Submitted: 2010-01-26
This paper is part of the Prelaunch status LFI papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jinst .
This paper describes the impact of the Planck Low Frequency Instrument front
end physical temperature fluctuations on the output signal. The origin of
thermal instabilities in the instrument are discussed, and an analytical model
of their propagation and impact on the receivers signal is described. The
experimental test setup dedicated to evaluate these effects during the
instrument ground calibration is reported together with data analysis methods.
Finally, main results obtained are discussed and compared to the requirements.
[4]
oai:arXiv.org:1001.4562 [pdf] - 1024812
Planck pre-launch status: Low Frequency Instrument calibration and
expected scientific performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R. J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Lawrence, C. R.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Meinhold, P.;
Mendes, L.;
Morgante, G.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Valenziano, L.;
Villa, F.;
Zacchei, A.;
Zonca, A.;
Balasini, M.;
Franceschet, C.;
Battaglia, P.;
Lapolla, P. M.;
Leutenegger, P.;
Miccolis, M.;
Pagan, L.;
Silvestri, R.;
Aja, B.;
Artal, E.;
Baldan, G.;
Bastia, P.;
Bernardino, T.;
Boschini, L.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
de La Fuente, L.;
Edgeley, J.;
Falvella, M. C.;
Ferrari, F.;
Fogliani, S.;
Franceschi, E.;
Gaier, T.;
Gomez, F.;
Herreros, J. M.;
Hildebrandt, S.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Lawson, D.;
Leahy, P.;
Levin, S.;
Lilje, P. B.;
Maino, D.;
Malaspina, M.;
Manzato, P.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Pasian, F.;
Pascual, J. P.;
Pecora, M.;
Peres-Cuevas, L.;
Platania, P.;
Pospieszalsky, M.;
Poutanen, T.;
Rebolo, R.;
Roddis, N.;
Salmon, M.;
Seiffert, M.;
Simonetto, A.;
Sozzi, C.;
Tauber, J.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-01-25
We give the calibration and scientific performance parameters of the Planck
Low Frequency Instrument (LFI) measured during the ground cryogenic test
campaign. These parameters characterise the instrument response and constitute
our best pre-launch knowledge of the LFI scientific performance. The LFI shows
excellent $1/f$ stability and rejection of instrumental systematic effects;
measured noise performance shows that LFI is the most sensitive instrument of
its kind. The set of measured calibration parameters will be updated during
flight operations through the end of the mission.