Normalized to: Salmaso, B.
[1]
oai:arXiv.org:1906.05648 [pdf] - 2007228
Thin glass shells for active optics for future space telescopes
Submitted: 2019-06-13
We present a method for the manufacturing of thin shells of glass, which
appears promising for the development of active optics for future space
telescopes. The method exploits the synergy of different mature technologies,
while leveraging the commercial availability of large, high-quality sheets of
glass, with thickness up to few millimeters. The first step of the method
foresees the pre-shaping of flat substrates of glass by replicating the
accurate shape of a mold via hot slumping technology. The replication concept
is advantageous for making large optics composed of many identical or similar
segments. After the hot slumping, the shape error residual on the optical
surface is addressed by applying a deterministic sub-aperture technology as
computer-controlled bonnet polishing and/or ion beam figuring. Here we focus on
the bonnet polishing case, during which the thin, deformable substrate of glass
is temporary stiffened by a removable holder. In this paper, we report on the
results so far achieved on a 130 mm glass shell case study.
[2]
oai:arXiv.org:1610.09258 [pdf] - 1504566
Design and advancement status of the Beam Expander Testing X-ray
facility (BEaTriX)
Spiga, D.;
Pelliciari, C.;
Salmaso, B.;
Arcangeli, L.;
Bianucci, G.;
Ferrari, C.;
Ghigo, M.;
Pareschi, G.;
Rossi, M.;
Tagliaferri, G.;
Valsecchi, G.;
Vecchi, G.;
Zappettini, A.
Submitted: 2016-10-28
The BEaTriX (Beam Expander Testing X-ray facility) project is an X-ray
apparatus under construction at INAF/OAB to generate a broad (200 x 60 mm2),
uniform and low-divergent X-ray beam within a small lab (6 x 15 m2). BEaTriX
will consist of an X-ray source in the focus a grazing incidence paraboloidal
mirror to obtain a parallel beam, followed by a crystal monochromation system
and by an asymmetrically-cut diffracting crystal to perform the beam expansion
to the desired size. Once completed, BEaTriX will be used to directly perform
the quality control of focusing modules of large X-ray optics such as those for
the ATHENA X-ray observatory, based on either Silicon Pore Optics (baseline) or
Slumped Glass Optics (alternative), and will thereby enable a direct quality
control of angular resolution and effective area on a number of mirror modules
in a short time, in full X-ray illumination and without being affected by the
finite distance of the X-ray source. However, since the individual mirror
modules for ATHENA will have an optical quality of 3-4 arcsec HEW or better,
BEaTriX is required to produce a broad beam with divergence below 1-2 arcsec,
and sufficient flux to quickly characterize the PSF of the module without being
significantly affected by statistical uncertainties. Therefore, the optical
components of BEaTriX have to be selected and/or manufactured with excellent
optical properties in order to guarantee the final performance of the system.
In this paper we report the final design of the facility and a detailed
performance simulation.
[3]
oai:arXiv.org:1610.00272 [pdf] - 1490021
Manufacturing and testing a thin glass mirror shell with piezoelectric
active control
Spiga, D.;
Barbera, M.;
Collura, A.;
Basso, S.;
Candia, R.;
Civitani, M.;
Di Bella, M.;
Di Cicca, G.;
Cicero, U. Lo;
Lullo, G.;
Pelliciari, C.;
Riva, M.;
Salmaso, B.;
Sciortino, L.;
Varisco, S.
Submitted: 2016-10-02
Optics for future X-ray telescopes will be characterized by very large
aperture and focal length, and will be made of lightweight materials like glass
or silicon in order to keep the total mass within acceptable limits. Optical
modules based on thin slumped glass foils are being developed at various
institutes, aiming at improving the angular resolution to a few arcsec HEW.
Thin mirrors are prone to deform, so they require a careful integration to
avoid deformations and even correct forming errors. On the other hand, this
offers the opportunity to actively correct the residual deformation: a viable
possibility to improve the mirror figure is the application of piezoelectric
actuators onto the non-optical side of the mirrors, and several groups are
already at work on this approach. The concept we are developing consists of
actively integrating thin glass foils with piezoelectric patches, fed by
voltages driven by the feedback provided by X-rays. The actuators are
commercial components, while the tension signals are carried by a printed
circuit obtained by photolithography, and the driving electronic is a
multi-channel low power consumption voltage supply developed in-house. Finally,
the shape detection and the consequent voltage signal to be provided to the
piezoelectric array are determined in X-rays, in intra-focal setup at the XACT
facility at INAF/OAPA. In this work, we describe the manufacturing steps to
obtain a first active mirror prototype and the very first test performed in
X-rays.
[4]
oai:arXiv.org:1609.09683 [pdf] - 1489510
Testing multilayer-coated polarizing mirrors for the LAMP soft X-ray
telescope
Spiga, D.;
Salmaso, B.;
She, R.;
Tayabaly, K.;
Wen, M.;
Banham, R.;
Costa, E.;
Feng, H.;
Giglia, A.;
Huang, Q.;
Muleri, F.;
Pareschi, G.;
Soffitta, P.;
Tagliaferri, G.;
Valsecchi, G.;
Wang, Z.
Submitted: 2016-09-30
The LAMP (Lightweight Asymmetry and Magnetism Probe) X-ray telescope is a
mission concept to measure the polarization of X-ray astronomical sources at
250 eV via imaging mirrors that reflect at incidence angles near the
polarization angle, i.e., 45 deg. Hence, it will require the adoption of
multilayer coatings with a few nanometers d-spacing in order to enhance the
reflectivity. The nickel electroforming technology has already been
successfully used to fabricate the high angular resolution imaging mirrors of
the X-ray telescopes SAX, XMM-Newton, and Swift/XRT. We are investigating this
consolidated technology as a possible technique to manufacture focusing mirrors
for LAMP. Although the very good reflectivity performances of this kind of
mirrors were already demonstrated in grazing incidence, the reflectivity and
the scattering properties have not been tested directly at the unusually large
angle of 45 deg. Other possible substrates are represented by thin glass foils
or silicon wafers. In this paper we present the results of the X-ray
reflectivity campaign performed at the BEAR beamline of Elettra - Sincrotrone
Trieste on multilayer coatings of various composition (Cr/C, Co/C), deposited
with different sputtering parameters on nickel, silicon, and glass substrates,
using polarized X-rays in the spectral range 240 - 290 eV.
[5]
oai:arXiv.org:1510.00910 [pdf] - 1287738
Active shape correction of a thin glass/plastic X-ray mirror
Spiga, D.;
Barbera, M.;
Basso, S.;
Civitani, M.;
Collura, A.;
Dell'Agostino, S.;
Cicero, U. Lo;
Lullo, G.;
Pelliciari, C.;
Riva, M.;
Salmaso, B.;
Sciortino, L.
Submitted: 2015-10-04
Optics for future X-ray telescopes will be characterized by very large
aperture and focal length, and will be made of lightweight materials like glass
or plastic in order to keep the total mass within acceptable limits. Optics
based on thin slumped glass foils are currently in use in the NuSTAR telescope
and are being developed at various institutes like INAF/OAB, aiming at
improving the angular resolution to a few arcsec HEW. Another possibility would
be the use of thin plastic foils, being developed at SAO and the Palermo
University. Even if relevant progresses in the achieved angular resolution were
recently made, a viable possibility to further improve the mirror figure would
be the application of piezoelectric actuators onto the non-optical side of the
mirrors. In fact, thin mirrors are prone to deform, so they require a careful
integration to avoid deformations and even correct forming errors. This however
offers the possibility to actively correct the residual deformation. Even if
other groups are already at work on this idea, we are pursuing the concept of
active integration of thin glass or plastic foils with piezoelectric patches,
fed by voltages driven by the feedback provided by X-rays, in intra-focal setup
at the XACT facility at INAF/OAPA. In this work, we show the preliminary
simulations and the first steps taken in this project.
[6]
oai:arXiv.org:1509.04392 [pdf] - 1277254
LAMP: a micro-satellite based soft X-ray polarimeter for astrophysics
She, Rui;
Feng, Hua;
Muleri, Fabio;
Soffitta, Paolo;
Xu, Renxin;
Li, Hong;
Bellazzini, Ronaldo;
Wang, Zhanshan;
Spiga, Daniele;
Minuti, Massimo;
Brez, Alessandro;
Spandre, Gloria;
Pinchera, Michele;
Sgro, Carmelo;
Baldini, Luca;
Wen, Mingwu;
Shen, Zhengxiang;
Pareschi, Giovanni;
Tagliaferri, Gianpiero;
Tayabaly, Kashmira;
Salmaso, Bianca;
Zhan, Yafeng
Submitted: 2015-09-15
The Lightweight Asymmetry and Magnetism Probe (LAMP) is a micro-satellite
mission concept dedicated for astronomical X-ray polarimetry and is currently
under early phase study. It consists of segmented paraboloidal multilayer
mirrors with a collecting area of about 1300 cm^2 to reflect and focus 250 eV
X-rays, which will be detected by position sensitive detectors at the focal
plane. The primary targets of LAMP include the thermal emission from the
surface of pulsars and synchrotron emission produced by relativistic jets in
blazars. With the expected sensitivity, it will allow us to detect polarization
or place a tight upper limit for about 10 pulsars and 20 blazars. In addition
to measuring magnetic structures in these objects, LAMP will also enable us to
discover bare quark stars if they exist, whose thermal emission is expected to
be zero polarized, while the thermal emission from neutron stars is believed to
be highly polarized due to plasma polarization and the quantum electrodynamics
(QED) effect. Here we present an overview of the mission concept, its science
objectives and simulated observational results.
[7]
oai:arXiv.org:1509.03478 [pdf] - 1275564
Angular resolution measurements at SPring-8 of a hard X-ray optic for
the New Hard X-ray Mission
Spiga, D.;
Raimondi, L.;
Furuzawa, A.;
Basso, S.;
Binda, R.;
Borghi, G.;
Cotroneo, V.;
Grisoni, G.;
Kunieda, H.;
Marioni, F.;
Matsumoto, H.;
Mori, H.;
Miyazawa, T.;
Negri, B.;
Orlandi, A.;
Pareschi, G.;
Salmaso, B.;
Tagliaferri, G.;
Uesugi, K.;
Valsecchi, G.;
Vernani, D.
Submitted: 2015-09-11
The realization of X-ray telescopes with imaging capabilities in the hard (>
10 keV) X-ray band requires the adoption of optics with shallow (< 0.25 deg)
grazing angles to enhance the reflectivity of reflective coatings. On the other
hand, to obtain large collecting area, large mirror diameters (< 350 mm) are
necessary. This implies that mirrors with focal lengths >10 m shall be produced
and tested. Full-illumination tests of such mirrors are usually performed with
on- ground X-ray facilities, aimed at measuring their effective area and the
angular resolution; however, they in general suffer from effects of the finite
distance of the X-ray source, e.g. a loss of effective area for double
reflection. These effects increase with the focal length of the mirror under
test; hence a "partial" full-illumination measurement might not be fully
representative of the in-flight performances. Indeed, a pencil beam test can be
adopted to overcome this shortcoming, because a sector at a time is exposed to
the X-ray flux, and the compensation of the beam divergence is achieved by
tilting the optic. In this work we present the result of a hard X-ray test
campaign performed at the BL20B2 beamline of the SPring-8 synchrotron radiation
facility, aimed at characterizing the Point Spread Function (PSF) of a
multilayer-coated Wolter-I mirror shell manufactured by Nickel electroforming.
The mirror shell is a demonstrator for the NHXM hard X-ray imaging telescope
(0.3 - 80 keV), with a predicted HEW (Half Energy Width) close to 20 arcsec. We
show some reconstructed PSFs at monochromatic X-ray energies of 15 to 63 keV,
and compare them with the PSFs computed from post-campaign metrology data,
self-consistently treating profile and roughness data by means of a method
based on the Fresnel diffraction theory. The modeling matches the measured PSFs
accurately.
[8]
oai:arXiv.org:1509.02298 [pdf] - 1273356
Profile reconstruction of grazing-incidence X-ray mirrors from
intra-focal X-ray full imaging
Spiga, D.;
Basso, S.;
Bavdaz, M.;
Burwitz, V.;
Civitani, M.;
Citterio, O.;
Ghigo, M.;
Hartner, G.;
Menz, B.;
Pareschi, G.;
Proserpio, L.;
Salmaso, B.;
Tagliaferri, G.;
Wille, E.
Submitted: 2015-09-08
The optics of a number of future X-ray telescopes will have very long focal
lengths (10 - 20 m), and will consist of a number of nested/stacked thin,
grazing-incidence mirrors. The optical quality characterization of a real
mirror can be obtained via profile metrology, and the Point Spread Function of
the mirror can be derived via one of the standard computation methods. However,
in practical cases it can be difficult to access the optical surfaces of
densely stacked mirror shells, after they have been assembled, using the
widespread metrological tools. For this reason, the assessment of the imaging
resolution of a system of mirrors is better obtained via a direct,
full-illumination test in X-rays. If the focus cannot be reached, an
intra-focus test can be performed, and the image can be compared with the
simulation results based on the metrology, if available. However, until today
no quantitative information was extracted from a full-illumination, intra-focal
exposure. In this work we show that, if the detector is located at an optimal
distance from the mirror, the intensity variations of the intra-focal,
full-illumination image in single reflection can be used to reconstruct the
profile of the mirror surface, without the need of a wavefront sensor. The
Point Spread Function can be subsequently computed from the reconstructed
mirror shape. We show the application of this method to an intra-focal (8 m
distance from mirror) test performed at PANTER on an optical module prototype
made of hot-slumped glass foils with a 20 m focal length, from which we could
derive an expected imaging quality near 16 arcsec HEW.
[9]
oai:arXiv.org:1502.03308 [pdf] - 1303946
Development of mirrors made of chemically tempered glass foils for
future X-ray telescopes
Submitted: 2015-02-11
Thin slumped glass foils are considered good candidates for the realization
of future X-ray telescopes with large effective area and high spatial
resolution. However, the hot slumping process affects the glass strength, and
this can be an issue during the launch of the satellite because of the high
kinematical and static loads occurring during that phase. In the present work
we have investigated the possible use of Gorilla glass (produced by Corning), a
chemical tempered glass that, thanks to its strength characteristics, would be
ideal. The un-tempered glass foils were curved by means of an innovative hot
slumping technique and subsequently chemically tempered. In this paper we show
that the chemical tempering process applied to Gorilla glass foils does not
affect the surface micro-roughness of the mirrors. On the other end, the stress
introduced by the tempering process causes a reduction in the amplitude of the
longitudinal profile errors with a lateral size close to the mirror length. The
effect of the overall shape changes in the final resolution performance of the
glass mirrors was studied by simulating the glass foils integration with our
innovative approach based on glass reinforcing ribs. The preliminary tests
performed so far suggest that this approach has the potential to be applied to
the X-ray telescopes of the next generation.
[10]
oai:arXiv.org:1402.3445 [pdf] - 1203354
Evaluation of the surface strength of glass plates shaped by hot
slumping process
Proserpio, L.;
Basso, S.;
Borsa, F.;
Citterio, O.;
Civitani, M.;
Ghigo, M.;
Pareschi, G.;
Salmaso, B.;
Sironi, G.;
Spiga, D.;
Tagliaferri, G.;
D'Este, A.;
Dall'Igna, R.;
Silvestri, M.;
Parodi, G.;
Martelli, F.;
Bavdaz, M.;
Wille, E.
Submitted: 2014-02-14, last modified: 2014-07-09
The Hot Slumping Technology is under development by several research groups
in the world for the realization of grazing-incidence segmented mirrors for
X-ray astronomy, based on thin glass plates shaped over a mould at temperatures
above the transformation point. The performed thermal cycle and related
operations might have effects on the strength characteristics of the glass,
with consequences on the structural design of the elemental optical modules and
consecutively on the entire X-ray optic for large astronomical missions like
IXO and ATHENA. The mechanical strength of glass plates after they underwent
the slumping process was tested through destructive double-ring tests in the
context of a study performed by the Astronomical Observatory of Brera with the
collaboration of Stazione Sperimentale del Vetro and BCV Progetti. The entire
study has been realized on more than 200 D263 Schott borosilicate glass
specimens of dimension 100 mm x 100 mm and thickness 0.4 mm, either flat or
bent at a Radius of Curvature of 1000 mm through the particular pressure
assisted hot slumping process developed by INAF-OAB. The collected experimental
data have been compared to non-linear FEM analyses and treated with Weibull
statistic to assess the current IXO glass X-ray telescope design, in terms of
survival probability, when subject to static and acoustic loads characteristic
of the launch phase. The paper describes the activities performed and presents
the obtained results.
[11]
oai:arXiv.org:1301.2974 [pdf] - 647875
X-ray scattering of periodic and graded multilayers: comparison of
experiments to simulations from surface microroughness characterization
Submitted: 2013-01-14, last modified: 2013-04-04
To enhance the reflectivity of X-ray mirrors beyond the critical angle,
multilayer coatings are required. Interface imperfections in the multilayer
growth process are known to cause non-specular scattering and degrade the
mirror optical performance; therefore, it is important to predict the amount of
X-ray scattering from the rough topography of the outer surface of the coating,
which can be directly measured, e.g., with an Atomic Force Microscope (AFM).
This kind of characterization, combined with X-ray reflectivity measurements to
assess the deep multilayer stack structure, can be used to model the layer
roughening during the growth process via a well-known roughness evolution
model. In this work, X-ray scattering measurements are performed and compared
with simulations obtained from the modeled interfacial Power Spectral Densities
(PSDs) and the modeled Crossed Spectral Densities for all the couples of
interfaces. We already used this approach in a previous work for periodic
multilayers; we now show how this method can be extended to graded multilayers.
The upgraded code is validated for both periodic and graded multilayers, with a
good accord between experimental data and model findings. Doing this, different
kind of defects observed in AFM scans are included in the PSD analysis. The
subsequent data-model comparison enables us to recognize them as surface
contamination or interfacial defects that contribute to the X-ray scattering of
the multilayer.