Normalized to: Sahoo, S.
[1]
oai:arXiv.org:2006.04126 [pdf] - 2109325
Mode identification in three pulsating hot subdwarfs observed with TESS
satellite
Sahoo, S. K.;
Baran, A. S.;
Heber, U.;
Ostrowski, J.;
Sanjayan, S.;
Silvotti, R.;
Irrgang, A.;
Uzundag, M.;
Reed, M. D.;
Shoaf, K. A.;
Raddi, R.;
Vuckovic, M.;
Ghasemi, H.;
Zong, W.;
Bell, K. J.
Submitted: 2020-06-07
We report on the detection of pulsations of three pulsating subdwarf B stars
observed by the TESS satellite and our results of mode identification in these
stars based on an asymptotic period relation. SB 459 (TIC 067584818), SB 815
(TIC 169285097) and PG 0342+026 (TIC 457168745) have been monitored during
single sectors resulting in 27 days coverage. These datasets allowed for
detecting, in each star, a few tens of frequencies, which we interpreted as
stellar oscillations. We found no multiplets, though we partially constrained
mode geometry by means of period spacing, which recently became a key tool in
analyses of pulsating subdwarf B stars. Standard routine that we have used
allowed us to select candidates for trapped modes that surely bear signatures
of non-uniform chemical profile inside the stars. We have also done statistical
analysis using collected spectroscopic and asteroseismic data of previously
known subdwarf B stars along with our three stars. Making use of high precision
trigonometric parallaxes from the Gaia mission and spectral energy
distributions we converted atmospheric parameters to stellar ones. Radii,
masses and luminosities are close to their canonical values for extreme
horizontal branch stars. In particular, the stellar masses are close to the
canonical one of 0.47 M$_\odot$ for all three stars but uncertainties on the
mass are large. The results of the analyses presented here will provide
important constrains for asteroseismic modelling.
[2]
oai:arXiv.org:1907.12509 [pdf] - 2100293
Velocity independent constraints on spin-dependent DM-nucleon
interactions from IceCube and PICO
IceCube Collaboration;
Aartsen, M. G.;
Ackermann, M.;
Adams, J.;
Aguilar, J. A.;
Ahlers, M.;
Ahrens, M.;
Alispach, C.;
Andeen, K.;
Anderson, T.;
Ansseau, I.;
Anton, G.;
Argüelles, C.;
Auffenberg, J.;
Axani, S.;
Backes, P.;
Bagherpour, H.;
Bai, X.;
V., A. Balagopal;
Barbano, A.;
Barwick, S. W.;
Bastian, B.;
Baum, V.;
Baur, S.;
Bay, R.;
Beatty, J. J.;
Becker, K. -H.;
Tjus, J. Becker;
BenZvi, S.;
Berley, D.;
Bernardini, E.;
Besson, D. Z.;
Binder, G.;
Bindig, D.;
Blaufuss, E.;
Blot, S.;
Bohm, C.;
Börner, M.;
Böser, S.;
Botner, O.;
Böttcher, J.;
Bourbeau, E.;
Bourbeau, J.;
Bradascio, F.;
Braun, J.;
Bron, S.;
Brostean-Kaiser, J.;
Burgman, A.;
Buscher, J.;
Busse, R. S.;
Carver, T.;
Chen, C.;
Cheung, E.;
Chirkin, D.;
Choi, S.;
Classen, L.;
Coleman, A.;
Collin, G. H.;
Conrad, J. M.;
Coppin, P.;
Correa, P.;
Cowen, D. F.;
Cross, R.;
Dave, P.;
De Clercq, C.;
DeLaunay, J. J.;
Dembinski, H.;
Deoskar, K.;
De Ridder, S.;
Desiati, P.;
de Vries, K. D.;
de Wasseige, G.;
de With, M.;
DeYoung, T.;
Diaz, A.;
Díaz-Vélez, J. C.;
Dujmovic, H.;
Dunkman, M.;
Dvorak, E.;
Eberhardt, B.;
Ehrhardt, T.;
Eller, P.;
Engel, R.;
Evenson, P. A.;
Fahey, S.;
Fazely, A. R.;
Felde, J.;
Filimonov, K.;
Finley, C.;
Franckowiak, A.;
Friedman, E.;
Fritz, A.;
Gaisser, T. K.;
Gallagher, J.;
Ganster, E.;
Garrappa, S.;
Gerhardt, L.;
Ghorbani, K.;
Glauch, T.;
Glüsenkamp, T.;
Goldschmidt, A.;
Gonzalez, J. G.;
Grant, D.;
Griffith, Z.;
Griswold, S.;
Günder, M.;
Gündüz, M.;
Haack, C.;
Hallgren, A.;
Halve, L.;
Halzen, F.;
Hanson, K.;
Haungs, A.;
Hebecker, D.;
Heereman, D.;
Heix, P.;
Helbing, K.;
Hellauer, R.;
Henningsen, F.;
Hickford, S.;
Hignight, J.;
Hill, G. C.;
Hoffman, K. D.;
Hoffmann, R.;
Hoinka, T.;
Hokanson-Fasig, B.;
Hoshina, K.;
Huang, F.;
Huber, M.;
Huber, T.;
Hultqvist, K.;
Hünnefeld, M.;
Hussain, R.;
In, S.;
Iovine, N.;
Ishihara, A.;
Japaridze, G. S.;
Jeong, M.;
Jero, K.;
Jones, B. J. P.;
Jonske, F.;
Joppe, R.;
Kang, D.;
Kang, W.;
Kappes, A.;
Kappesser, D.;
Karg, T.;
Karl, M.;
Karle, A.;
Katz, U.;
Kauer, M.;
Kelley, J. L.;
Kheirandish, A.;
Kim, J.;
Kintscher, T.;
Kiryluk, J.;
Kittler, T.;
Klein, S. R.;
Koirala, R.;
Kolanoski, H.;
Köpke, L.;
Kopper, C.;
Kopper, S.;
Koskinen, D. J.;
Kowalski, M.;
Krings, K.;
Krückl, G.;
Kulacz, N.;
Kurahashi, N.;
Kyriacou, A.;
Labare, M.;
Lanfranchi, J. L.;
Larson, M. J.;
Lauber, F.;
Lazar, J. P.;
Leonard, K.;
Leszczyńska, A.;
Leuermann, M.;
Liu, Q. R.;
Lohfink, E.;
Mariscal, C. J. Lozano;
Lu, L.;
Lucarelli, F.;
Lünemann, J.;
Luszczak, W.;
Lyu, Y.;
Ma, W. Y.;
Madsen, J.;
Maggi, G.;
Mahn, K. B. M.;
Makino, Y.;
Mallik, P.;
Mallot, K.;
Mancina, S.;
Mariş, I. C.;
Maruyama, R.;
Mase, K.;
Maunu, R.;
McNally, F.;
Meagher, K.;
Medici, M.;
Medina, A.;
Meier, M.;
Meighen-Berger, S.;
Menne, T.;
Merino, G.;
Meures, T.;
Micallef, J.;
Mockler, D.;
Momenté, G.;
Montaruli, T.;
Moore, R. W.;
Morse, R.;
Moulai, M.;
Muth, P.;
Nagai, R.;
Naumann, U.;
Neer, G.;
Niederhausen, H.;
Nowicki, S. C.;
Nygren, D. R.;
Pollmann, A. Obertacke;
Oehler, M.;
Olivas, A.;
O'Murchadha, A.;
O'Sullivan, E.;
Palczewski, T.;
Pandya, H.;
Pankova, D. V.;
Park, N.;
Peiffer, P.;
Heros, C. Pérez de los;
Philippen, S.;
Pieloth, D.;
Pinat, E.;
Pizzuto, A.;
Plum, M.;
Porcelli, A.;
Price, P. B.;
Przybylski, G. T.;
Raab, C.;
Raissi, A.;
Rameez, M.;
Rauch, L.;
Rawlins, K.;
Rea, I. C.;
Reimann, R.;
Relethford, B.;
Renschler, M.;
Renzi, G.;
Resconi, E.;
Rhode, W.;
Richman, M.;
Robertson, S.;
Rongen, M.;
Rott, C.;
Ruhe, T.;
Ryckbosch, D.;
Rysewyk, D.;
Safa, I.;
Herrera, S. E. Sanchez;
Sandrock, A.;
Sandroos, J.;
Santander, M.;
Sarkar, S.;
Sarkar, S.;
Satalecka, K.;
Schaufel, M.;
Schieler, H.;
Schlunder, P.;
Schmidt, T.;
Schneider, A.;
Schneider, J.;
Schröder, F. G.;
Schumacher, L.;
Sclafani, S.;
Seckel, D.;
Seunarine, S.;
Shefali, S.;
Silva, M.;
Snihur, R.;
Soedingrekso, J.;
Soldin, D.;
Song, M.;
Spiczak, G. M.;
Spiering, C.;
Stachurska, J.;
Stamatikos, M.;
Stanev, T.;
Stein, R.;
Steinmüller, P.;
Stettner, J.;
Steuer, A.;
Stezelberger, T.;
Stokstad, R. G.;
Stößl, A.;
Strotjohann, N. L.;
Stürwald, T.;
Stuttard, T.;
Sullivan, G. W.;
Taboada, I.;
Tenholt, F.;
Ter-Antonyan, S.;
Terliuk, A.;
Tilav, S.;
Tomankova, L.;
Tönnis, C.;
Toscano, S.;
Tosi, D.;
Trettin, A.;
Tselengidou, M.;
Tung, C. F.;
Turcati, A.;
Turcotte, R.;
Turley, C. F.;
Ty, B.;
Unger, E.;
Elorrieta, M. A. Unland;
Usner, M.;
Vandenbroucke, J.;
Van Driessche, W.;
van Eijk, D.;
van Eijndhoven, N.;
Vanheule, S.;
van Santen, J.;
Vraeghe, M.;
Walck, C.;
Wallace, A.;
Wallraff, M.;
Wandkowsky, N.;
Watson, T. B.;
Weaver, C.;
Weindl, A.;
Weiss, M. J.;
Weldert, J.;
Wendt, C.;
Werthebach, J.;
Whelan, B. J.;
Whitehorn, N.;
Wiebe, K.;
Wiebusch, C. H.;
Wille, L.;
Williams, D. R.;
Wills, L.;
Wolf, M.;
Wood, J.;
Wood, T. R.;
Woschnagg, K.;
Wrede, G.;
Xu, D. L.;
Xu, X. W.;
Xu, Y.;
Yanez, J. P.;
Yodh, G.;
Yoshida, S.;
Yuan, T.;
Collaboration, M. Zöcklein. PICO;
:;
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hoppe, E. W.;
Jin, M.;
Klopfenstein, L.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Lippincott, W. H.;
Mamedov, F.;
Maurya, D.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Piro, M. -C.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Walkowski, N.;
Wichoski, U.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-07-29, last modified: 2020-05-25
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity
distribution for dark matter (DM) particles in the Galaxy, the most stringent
current constraints on their spin-dependent scattering cross-section with
nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$
superheated bubble chamber experiments. The former is sensitive to high energy
neutrinos from the self-annihilation of DM particles captured in the Sun, while
the latter looks for nuclear recoil events from DM scattering off nucleons.
Although slower DM particles are more likely to be captured by the Sun, the
faster ones are more likely to be detected by PICO. Recent N-body simulations
suggest significant deviations from the SHM for the smooth halo component of
the DM, while observations hint at a dominant fraction of the local DM being in
substructures. We use the method of Ferrer et al. (2015) to exploit the
complementarity between the two approaches and derive conservative constraints
on DM-nucleon scattering. Our results constrain $\sigma_{\mathrm{SD}} \lesssim
3 \times 10^{-39} \mathrm{cm}^2$ (6 $ \times 10^{-38} \mathrm{cm}^2$) at
$\gtrsim 90\%$ C.L. for a DM particle of mass 1~TeV annihilating into $\tau^+
\tau^-$ ($b\bar{b}$) with a local density of $\rho_{\mathrm{DM}} = 0.3~\mathrm{
GeV/cm}^3$. The constraints scale inversely with $\rho_{\mathrm{DM}}$ and are
independent of the DM velocity distribution.
[3]
oai:arXiv.org:1905.04706 [pdf] - 2093082
Probing low-mass WIMP candidates of dark matter with tetrafluoroethane
superheated liquid detectors
Submitted: 2019-05-12, last modified: 2020-04-18
Probing low mass (sub-GeV -- few GeV) Weakly Interacting Massive Particle
(WIMP) candidates of dark matter through WIMP-induced nuclear recoils in direct
detection experiments requires use of detector materials consisting of low mass
target nuclei and low threshold energy. Here we explore the potential of
superheated liquid detectors (SLD) with a hydrogen containing liquid, namely,
tetrafluoroethane (C$_{2}$H$_{2}$F$_{4}$) (b.p.~$-26.3^\circ\,$C), as the
target material for probing low mass WIMPs. It is found that few-keV level
recoil energy thresholds possible for bubble nucleation by WIMP-induced
$^{12}$C and $^{19}$F recoils in C$_{2}$H$_{2}$F$_{4}$ SLDs operated at
atmospheric pressure and gamma-ray insensitive temperatures of $T\, \lesssim\,
35^\circ\,$C have the potential to allow WIMPs in the few-GeV mass range to be
probed at a WIMP-nucleon spin-independent cross section sensitivity levels (90%
C.L.) better than $4.6\times 10^{-5}\,$pb at WIMP masses down to $\sim$ 4 GeV
with a total exposure of $\sim$ 1000 kg.day, provided that the ``thermodynamic
efficiency" $\eta_{\rm T}$ that determines the bubble nucleation thresholds for
the recoiling nuclei in C$_{2}$H$_{2}$F$_{4}$ is $\sim$ 50% or higher.
Sensitivity to sub-GeV WIMP masses generally requires the detector to be
sensitive to the WIMP-induced $^1$H recoils, which in turn requires the
detector to be operated at temperatures $T\gtrsim 50^\circ\,$C and $\eta_{\rm
T}$ close to 100%. At such relatively high temperatures (at atmospheric
pressure), however, the detector would be sensitive to background gamma rays.
[4]
oai:arXiv.org:1905.12522 [pdf] - 1995410
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$
Bubble Chambers
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chen, S.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Filgas, R.;
Fuentes, J.;
Girard, F.;
Giroux, G.;
Hackett, B.;
Hagen, A.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Kozynets, T.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Pal, S.;
Piro, M. -C.;
Plante, A.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Tiwari, D.;
Vázquez-Jáuregui, E.;
Wagner, J. M.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Woodley, W.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-05-29, last modified: 2019-11-06
The primary advantage of moderately superheated bubble chamber detectors is
their simultaneous sensitivity to nuclear recoils from WIMP dark matter and
insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO
gamma calibration data demonstrates for the first time that electron recoils in
C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one
driven by a hot-spike as previously supposed. Using this semi-empirical model,
bubble chamber nucleation thresholds may be tuned to be sensitive to lower
energy nuclear recoils while maintaining excellent electron recoil rejection.
The PICO-40L detector will exploit this model to achieve thermodynamic
thresholds as low as 2.8 keV while being dominated by single-scatter events
from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one
year of operation, PICO-40L can improve existing leading limits from PICO on
spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP
masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all
existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP
masses from 3 to 40 GeV c$^{-2}$.
[5]
oai:arXiv.org:1902.04031 [pdf] - 1916812
Dark Matter Search Results from the Complete Exposure of the PICO-60
C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Piro, M. -C.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-02-11
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark
matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in
the SNOLAB underground laboratory. The chamber was operated at thermodynamic
thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day
exposure at 2.45 keV threshold was acquired with approximately the same
expected total background rate as the previous 1167-kg-day exposure at 3.3 keV.
This increased exposure is enabled in part by a new optical tracking analysis
to better identify events near detector walls, permitting a larger fiducial
volume. These results set the most stringent direct-detection constraint to
date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$
cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV
WIMPs by an order of magnitude.