Normalized to: Sagiv, I.
[1]
oai:arXiv.org:1803.01018 [pdf] - 1783724
The EBEX Balloon Borne Experiment - Detectors and Readout
The EBEX Collaboration;
Abitbol, Maximilian;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Feeney, Stephen M.;
Geach, Christopher;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Johannes;
Irwin, Kent;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Miller, Amber D.;
Milligan, Michael;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Tucker, Gregory S.;
Westbrook, Benjamin;
Young, Karl;
Zilic, Kyle
Submitted: 2018-03-02, last modified: 2018-07-30
EBEX was a long-duration balloon-borne experiment to measure the polarization
of the cosmic microwave background. The experiment had three frequency bands
centered at 150, 250, and 410 GHz and was the first to use a kilo-pixel array
of transition edge sensor (TES) bolometers aboard a balloon platform; shortly
after reaching float we operated 504, 342, and 109 TESs at each of the bands,
respectively. We describe the design and characterization of the array and the
readout system. We give the distributions of measured thermal conductances,
normal resistances, and transition temperatures. With the exception of the
thermal conductance at 150 GHz. We measured median low-loop-gain time constants
$\tau_{0}=$ 88, 46, and 57 ms and compare them to predictions. Two measurements
of bolometer absorption efficiency show high ($\sim$0.9) efficiency at 150 GHz
and medium ($\sim$0.35, and $\sim$0.25) at the two higher bands, respectively.
We measure a median total optical load of 3.6, 5.3 and 5.0 pW absorbed at the
three bands, respectively. EBEX pioneered the use of the digital version of the
frequency domain multiplexing (FDM) system which multiplexed the bias and
readout of 16 bolometers onto two wires. We present accounting of the measured
noise equivalent power. The median per-detector noise equivalent temperatures
referred to a black body with a temperature of 2.725 K are 400, 920, and 14500
$\mu$K$\sqrt{s}$ for the three bands, respectively. We compare these values to
our pre-flight predictions and to a previous balloon payload, discuss the
sources of excess noise, and the path for a future payload to make full use of
the balloon environment.
[2]
oai:arXiv.org:1711.01314 [pdf] - 1877825
Intensity-Coupled-Polarization in Instruments with a Continuously
Rotating Half-Wave Plate
Didier, Joy;
Miller, Amber D.;
Araujo, Derek;
Aubin, François;
Geach, Christopher;
Johnson, Bradley;
Korotkov, Andrei;
Raach, Kate;
Westbrook, Benjamin;
Young, Karl;
Aboobaker, Asad M.;
Ade, Peter;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Jones, Terry;
Klein, Jeff;
Lee, Adrian;
Limon, Michele;
MacDermid, Kevin;
Milligan, Michael;
Pascale, Enzo;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Carole;
Tucker, Gregory S.;
Zilic, Kyle
Submitted: 2017-11-03, last modified: 2018-02-28
We discuss a systematic effect associated with measuring polarization with a
continuously rotating half-wave plate. The effect was identified with the data
from the E and B Experiment (EBEX), which was a balloon-borne instrument
designed to measure the polarization of the CMB as well as that from Galactic
dust. The data show polarization fraction larger than 10\% while less than 3\%
were expected from instrumental polarization. We give evidence that the excess
polarization is due to detector non-linearity in the presence of a continuously
rotating HWP. The non-linearity couples intensity signals into polarization. We
develop a map-based method to remove the excess polarization. Applying this
method for the 150 (250) GHz bands data we find that 81\% (92\%) of the excess
polarization was removed. Characterization and mitigation of this effect is
important for future experiments aiming to measure the CMB B-modes with a
continuously rotating HWP.
[3]
oai:arXiv.org:1703.03847 [pdf] - 1783689
The EBEX Balloon Borne Experiment - Optics, Receiver, and Polarimetry
The EBEX Collaboration;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Geach, Christopher;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Matsumura, Tomotake;
Miller, Amber D.;
Milligan, Michael;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Savini, Giorgio;
Spencer, Locke;
Tucker, Carole;
Tucker, Gregory S.;
Westbrook, Ben;
Young, Karl;
Zilic, Kyle
Submitted: 2017-03-10, last modified: 2017-05-30
The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic
microwave background polarimeter that flew over Antarctica in 2013. We describe
the experiment's optical system, receiver, and polarimetric approach, and
report on their in-flight performance. EBEX had three frequency bands centered
on 150, 250, and 410 GHz. To make efficient use of limited mass and space we
designed a 115 cm$^{2}$sr high throughput optical system that had two ambient
temperature mirrors and four anti-reflection coated polyethylene lenses per
focal plane. All frequency bands shared the same optical train. Polarimetry was
achieved with a continuously rotating achromatic half-wave plate (AHWP) that
was levitated with a superconducting magnetic bearing (SMB). Rotation stability
was 0.45 % over a period of 10 hours, and angular position accuracy was 0.01
degrees. This is the first use of a SMB in astrophysics. The measured
modulation efficiency was above 90 % for all bands. To our knowledge the 109 %
fractional bandwidth of the AHWP was the broadest implemented to date. The
receiver that contained one lens and the AHWP at a temperature of 4 K, the
polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K
performed according to specifications giving focal plane temperature stability
with fluctuation power spectrum that had $1/f$ knee at 2 mHz. EBEX was the
first balloon-borne instrument to implement technologies characteristic of
modern CMB polarimeters including high throughput optical systems, and large
arrays of transition edge sensor bolometric detectors with mutiplexed readouts.
[4]
oai:arXiv.org:1702.01861 [pdf] - 1568902
A Double Vacuum Window Mechanism for Space-borne Applications
Submitted: 2017-02-06, last modified: 2017-04-26
We present a vacuum window mechanism that is useful for applications
requiring two different vacuum windows in series, with one of them movable and
resealable. Such applications include space borne instruments that can benefit
from a thin vacuum window at low ambient pressures, but must also have an
optically open aperture at atmospheric pressures. We describe the
implementation and successful operation with the EBEX balloon-borne payload, a
millimeter-wave instrument designed to measure the polarization of the cosmic
microwave background radiation.
[5]
oai:arXiv.org:1702.07020 [pdf] - 1783687
The EBEX Balloon-Borne Experiment - Gondola, Attitude Control, and
Control Software
The EBEX Collaboration;
Aboobaker, Asad;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Miller, Amber D.;
Milligan, Michael;
Moncelsi, Lorenzo;
Pascale, Enzo;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Carole;
Tucker, Gregory S.;
Westbrook, Benjamin;
Young, Karl;
Zilic, Kyle
Submitted: 2017-02-22, last modified: 2017-04-11
The E and B Experiment (EBEX) was a long-duration balloon-borne instrument
designed to measure the polarization of the cosmic microwave background (CMB)
radiation. EBEX was the first balloon-borne instrument to implement a
kilo-pixel array of transition edge sensor (TES) bolometric detectors and the
first CMB experiment to use the digital version of the frequency domain
multiplexing system for readout of the TES array. The scan strategy relied on
40 s peak-to-peak constant velocity azimuthal scans. We discuss the unique
demands on the design and operation of the payload that resulted from these new
technologies and the scan strategy. We describe the solutions implemented
including the development of a power system designed to provide a total of at
least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors'
readout system, software to manage and handle the data of the kilo-pixel array,
and specialized attitude reconstruction software. We present flight performance
data showing faultless management of the TES array, adequate powering and
cooling of the readout electronics, and constraint of attitude reconstruction
errors such that the spurious B-modes they induced were less than 10% of CMB
B-mode power spectrum with $r=0.05$.
[6]
oai:arXiv.org:1602.03249 [pdf] - 1356056
A high-resolution pointing system for fast scanning platforms: The EBEX
example
Didier, Joy;
Chapman, Daniel;
Aboobaker, Asad;
Araujo, Derek;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Korotkov, Andrei;
Limon, Michele;
Miller, Amber;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Greg;
Vinokurov, Yuri
Submitted: 2016-02-09
The E and B experiment (EBEX) is a balloon-borne telescope designed to
measure the polarization of the cosmic microwave background with 8' resolution
employing a gondola scanning with speeds of order degree per second. In January
2013, EBEX completed 11 days of observations in a flight over Antarctica
covering $\sim$ 6000 square degrees of the sky. The payload is equipped with
two redundant star cameras and two sets of three orthogonal gyroscopes to
reconstruct the telescope attitude. The EBEX science goals require the pointing
to be reconstructed to approximately 10" in the map domain, and in-flight
attitude control requires the real time pointing to be accurate to $\sim$
0.5$^{\circ}$ . The high velocity scan strategy of EBEX coupled to its float
altitude only permits the star cameras to take images at scan turnarounds,
every $\sim$ 40 seconds, and thus requires the development of a pointing system
with low noise gyroscopes and carefully controlled systematic errors. Here we
report on the design of the pointing system and on a simulation pipeline
developed to understand and minimize the effects of systematic errors. The
performance of the system is evaluated using the 2012/2013 flight data, and we
show that we achieve a pointing error with RMS=25" on 40 seconds azimuth
throws, corresponding to an error of $\sim$ 4.6" in the map domain.
[7]
oai:arXiv.org:1601.07923 [pdf] - 1350058
Temperature calibration of the E and B experiment
Aubin, Francois;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Feeney, Stephen;
Geach, Christopher;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
Macdermid, Kevin;
Marchenko, Valerie;
Miller, Amber D.;
Milligan, Michael;
Pascale, Enzo;
Puglisi, Giuseppe;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Stompor, Radek;
Tristram, Matthieu;
Tucker, Gregory S.;
Westbrook, Ben;
Young, Karl;
Zilic, Kyle
Submitted: 2016-01-28
The E and B Experiment (EBEX) is a balloon-borne polarimeter designed to
measure the polarization of the cosmic microwave background radiation and to
characterize the polarization of galactic dust. EBEX was launched December 29,
2012 and circumnavigated Antarctica observing $\sim$6,000 square degrees of sky
during 11 days at three frequency bands centered around 150, 250 and 410 GHz.
EBEX was the first experiment to operate a kilo-pixel array of transition-edge
sensor bolometers and a continuously rotating achromatic half-wave plate aboard
a balloon platform. It also pioneered the use of detector readout based on
digital frequency domain multiplexing.
We describe the temperature calibration of the experiment. The gain response
of the experiment is calibrated using a two-step iterative process. We use
signals measured on passes across the Galactic plane to convert from
readout-system counts to power. The effective smoothing scale of the EBEX
optics and the star camera-to-detector offset angles are determined through
\c{hi}2 minimization using the compact HII region RCW 38. This two-step process
is initially performed with parameters measured before the EBEX 2013 flight and
then repeated until the calibration factor and parameters converge.
[8]
oai:arXiv.org:1505.05158 [pdf] - 1056010
Strong Ultraviolet Pulse From a Newborn Type Ia Supernova
Cao, Yi;
Kulkarni, S. R.;
Howell, D. Andrew;
Gal-Yam, Avishay;
Kasliwal, Mansi M.;
Valenti, Stefano;
Johansson, J.;
Amanullah, R.;
Goobar, A.;
Sollerman, J.;
Taddia, F.;
Horesh, Assaf;
Sagiv, Ilan;
Cenko, S. Bradley;
Nugent, Peter E.;
Arcavi, Iair;
Surace, Jason;
Woźniak, P. R.;
Moody, Daniela I.;
Rebbapragada, Umaa D.;
Bue, Brian D.;
Gehrels, Neil
Submitted: 2015-05-19
Type Ia supernovae are destructive explosions of carbon oxygen white dwarfs.
Although they are used empirically to measure cosmological distances, the
nature of their progenitors remains mysterious, One of the leading progenitor
models, called the single degenerate channel, hypothesizes that a white dwarf
accretes matter from a companion star and the resulting increase in its central
pressure and temperature ignites thermonuclear explosion. Here we report
observations of strong but declining ultraviolet emission from a Type Ia
supernova within four days of its explosion. This emission is consistent with
theoretical expectations of collision between material ejected by the supernova
and a companion star, and therefore provides evidence that some Type Ia
supernovae arise from the single degenerate channel.
[9]
oai:arXiv.org:1412.4063 [pdf] - 1382045
The detection rate of early UV emission from supernovae: A dedicated
GALEX/PTF survey and calibrated theoretical estimates
Ganot, Noam;
Gal-Yam, Avishay;
Ofek, Eran O.;
Sagiv, Ilan;
Waxman, Eli;
Lapid, Ofer;
Kulkarni, Shrinivas R.;
Ben-Ami, Sagi;
Kasliwal, Mansi M.;
Chelouche, Doron;
Rafter, Stephen;
Behar, Ehud;
Laor, Ari;
Poznanski, Dovi;
Nakar, Udi;
Maoz, Dan;
Trakhtenbrot, Benny;
Neill, James D.;
Barlow, Thomas A.;
Martin, Christofer D.;
Gezari, Suvi;
Arcavi, Iair;
Bloom, Joshua s.;
Nugent, Peter E.;
Sullivan, Mark
Submitted: 2014-12-12, last modified: 2015-02-25
The radius and surface composition of an exploding massive star,as well as
the explosion energy per unit mass, can be measured using early UV observations
of core collapse supernovae (SNe). We present the first results from a
simultaneous GALEX/PTF search for early UV emission from SNe. Six Type II SNe
and one Type II superluminous SN (SLSN-II) are clearly detected in the GALEX
NUV data. We compare our detection rate with theoretical estimates based on
early, shock-cooling UV light curves calculated from models that fit existing
Swift and GALEX observations well, combined with volumetric SN rates. We find
that our observations are in good agreement with calculated rates assuming that
red supergiants (RSGs) explode with fiducial radii of 500 solar, explosion
energies of 10^51 erg, and ejecta masses of 10 solar masses. Exploding blue
supergiants and Wolf-Rayet stars are poorly constrained. We describe how such
observations can be used to derive the progenitor radius, surface composition
and explosion energy per unit mass of such SN events, and we demonstrate why UV
observations are critical for such measurements. We use the fiducial RSG
parameters to estimate the detection rate of SNe during the shock-cooling phase
(<1d after explosion) for several ground-based surveys (PTF, ZTF, and LSST). We
show that the proposed wide-field UV explorer ULTRASAT mission, is expected to
find >100 SNe per year (~0.5 SN per deg^2), independent of host galaxy
extinction, down to an NUV detection limit of 21.5 mag AB. Our pilot GALEX/PTF
project thus convincingly demonstrates that a dedicated, systematic SN survey
at the NUV band is a compelling method to study how massive stars end their
life.
[10]
oai:arXiv.org:1407.6894 [pdf] - 1215912
The performance of the bolometer array and readout system during the
2012/2013 flight of the E and B experiment (EBEX)
MacDermid, Kevin;
Aboobaker, Asad M.;
Ade, Peter;
Aubin, Francois;
Baccigalupi, Carlo;
Bandura, Kevin;
Bao, Chaoyun;
Borrill, Julian;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grain, Julien;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Hannes;
Irwin, Kent;
Johnson, Bradley;
Jaffe, Andrew;
Jones, Terry;
Kisner, Ted;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
Miller, Amber;
Milligan, Michael;
Pascale, Enzo;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Stompor, Radek;
Tristram, Matthieu;
Tucker, Greg;
Westbrook, Ben;
Zilic, Kyle
Submitted: 2014-07-22
EBEX is a balloon-borne telescope designed to measure the polarization of the
cosmic microwave background radiation. During its eleven day science flight in
the Austral Summer of 2012, it operated 955 spider-web transition edge sensor
(TES) bolometers separated into bands at 150, 250 and 410 GHz. This is the
first time that an array of TES bolometers has been used on a balloon platform
to conduct science observations. Polarization sensitivity was provided by a
wire grid and continuously rotating half-wave plate. The balloon implementation
of the bolometer array and readout electronics presented unique development
requirements. Here we present an outline of the readout system, the remote
tuning of the bolometers and Superconducting QUantum Interference Device
(SQUID) amplifiers, and preliminary current noise of the bolometer array and
readout system.
[11]
oai:arXiv.org:1303.6194 [pdf] - 1165511
Science with a wide-field UV transient explorer
Sagiv, I.;
Gal-Yam, A.;
Ofek, E. O.;
Waxman, E.;
Aharonson, O.;
Nakar, E.;
Maoz, D.;
Trakhtenbrot, B.;
Kulkarni, S. R.;
Phinney, E. S.;
Topaz, J.;
Beichman, C.;
Murthy, J.;
Worden, S. P.
Submitted: 2013-03-25
The time-variable electromagnetic sky has been well-explored at a wide range
of wavelengths. Numerous high-energy space missions take advantage of the dark
Gamma-ray and X-ray sky and utilize very wide field detectors to provide almost
continuous monitoring of the entire celestial sphere. In visible light, new
wide-field ground-based surveys cover wide patches of sky with ever decreasing
cadence, progressing from monthly-weekly time scale surveys to sub-night
sampling. In the radio, new powerful instrumentation offers unprecedented
sensitivity over wide fields of view, with pathfinder experiments for even more
ambitious programs underway. In contrast, the ultra-violet (UV) variable sky is
relatively poorly explored, even though it offers exciting scientific
prospects. Here, we review the potential scientific impact of a wide-field UV
survey on the study of explosive and other transient events, as well as known
classes of variable objects, such as active galactic nuclei and variable stars.
We quantify our predictions using a fiducial set of observational parameters
which are similar to those envisaged for the proposed ULTRASAT mission. We show
that such a mission would be able to revolutionize our knowledge about massive
star explosions by measuring the early UV emission from hundreds of events,
revealing key physical parameters of the exploding progenitor stars. Such a
mission would also detect the UV emission from many tens of tidal-disruption
events of stars by super massive black holes at galactic nuclei and enable a
measurement of the rate of such events. The overlap of such a wide-field UV
mission with existing and planned gravitational-wave and high-energy neutrino
telescopes makes it especially timely.
[12]
oai:arXiv.org:1007.3672 [pdf] - 1033814
EBEX: A balloon-borne CMB polarization experiment
Reichborn-Kjennerud, Britt;
Aboobaker, Asad M.;
Ade, Peter;
Aubin, Françcois;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Cantalupo, Christopher;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grain, Julien;
Grainger, William;
Hanany, Shaul;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Leach, Sam;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Matsumura, Tomotake;
Meng, Xiaofan;
Miller, Amber;
Milligan, Michael;
Pascale, Enzo;
Polsgrove, Daniel;
Ponthieu, Nicolas;
Raach, Kate;
Sagiv, Ilan;
Smecher, Graeme;
Stivoli, Federico;
Stompor, Radek;
Tran, Huan;
Tristram, Matthieu;
Tucker, Gregory S.;
Vinokurov, Yury;
Yadav, Amit;
Zaldarriaga, Matias;
Zilic, Kyle
Submitted: 2010-07-21
EBEX is a NASA-funded balloon-borne experiment designed to measure the
polarization of the cosmic microwave background (CMB). Observations will be
made using 1432 transition edge sensor (TES) bolometric detectors read out with
frequency multiplexed SQuIDs. EBEX will observe in three frequency bands
centered at 150, 250, and 410 GHz, with 768, 384, and 280 detectors in each
band, respectively. This broad frequency coverage is designed to provide
valuable information about polarized foreground signals from dust. The
polarized sky signals will be modulated with an achromatic half wave plate
(AHWP) rotating on a superconducting magnetic bearing (SMB) and analyzed with a
fixed wire grid polarizer. EBEX will observe a patch covering ~1% of the sky
with 8' resolution, allowing for observation of the angular power spectrum from
\ell = 20 to 1000. This will allow EBEX to search for both the primordial
B-mode signal predicted by inflation and the anticipated lensing B-mode signal.
Calculations to predict EBEX constraints on r using expected noise levels show
that, for a likelihood centered around zero and with negligible foregrounds,
99% of the area falls below r = 0.035. This value increases by a factor of 1.6
after a process of foreground subtraction. This estimate does not include
systematic uncertainties. An engineering flight was launched in June, 2009,
from Ft. Sumner, NM, and the long duration science flight in Antarctica is
planned for 2011. These proceedings describe the EBEX instrument and the North
American engineering flight.
[13]
oai:arXiv.org:1006.5256 [pdf] - 229058
Software systems for operation, control, and monitoring of the EBEX
instrument
Milligan, Michael;
Ade, Peter;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Cantalupo, Christopher;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Leach, Sam;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Matsumura, Tomotake;
Miller, Amber;
Pascale, Enzo;
Polsgrove, Daniel;
Ponthieu, Nicolas;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tran, Huan;
Tucker, Gregory S.;
Vinokurov, Yury;
Yadav, Amit;
Zaldarriaga, Matias;
Zilic, Kyle
Submitted: 2010-06-27, last modified: 2010-07-05
We present the hardware and software systems implementing autonomous
operation, distributed real-time monitoring, and control for the EBEX
instrument. EBEX is a NASA-funded balloon-borne microwave polarimeter designed
for a 14 day Antarctic flight that circumnavigates the pole. To meet its
science goals the EBEX instrument autonomously executes several tasks in
parallel: it collects attitude data and maintains pointing control in order to
adhere to an observing schedule; tunes and operates up to 1920 TES bolometers
and 120 SQUID amplifiers controlled by as many as 30 embedded computers;
coordinates and dispatches jobs across an onboard computer network to manage
this detector readout system; logs over 3~GiB/hour of science and housekeeping
data to an onboard disk storage array; responds to a variety of commands and
exogenous events; and downlinks multiple heterogeneous data streams
representing a selected subset of the total logged data. Most of the systems
implementing these functions have been tested during a recent engineering
flight of the payload, and have proven to meet the target requirements. The
EBEX ground segment couples uplink and downlink hardware to a client-server
software stack, enabling real-time monitoring and command responsibility to be
distributed across the public internet or other standard computer networks.
Using the emerging dirfile standard as a uniform intermediate data format, a
variety of front end programs provide access to different components and views
of the downlinked data products. This distributed architecture was demonstrated
operating across multiple widely dispersed sites prior to and during the EBEX
engineering flight.
[14]
oai:arXiv.org:1005.3339 [pdf] - 168465
The EBEX Cryostat and Supporting Electronics
Sagiv, Ilan;
Aboobaker, Asad M.;
Bao, Chaoyun;
Hanany, Shaul;
Jones, Terry;
Klein, Jeffrey;
Milligan, Michael;
Polsgrove, Daniel E.;
Raach, Kate;
Zilic, Kyle;
Korotkov, Andrei;
Tucker, Gregory S.;
Vinukurov, Yuri;
Matsumura, Tomotake;
Ade, Peter;
Grainger, Will;
Pascale, Enzo;
Chapman, Daniel;
Didier, Joy;
Hillbrand, Seth;
Reichborn-Kjennerud, Britt;
Limon, Michele;
Miller, Amber;
Jaffe, Andrew;
Yadav, Amit;
Zaldarriaga, Matias;
Ponthieu, Nicolas;
Tristram, Matthieu;
Borrill, Julian;
Cantalupo, Christopher;
Kisner, Ted;
Aubin, Francois;
Dobbs, Matt;
MacDermid, Kevin;
Hilton, Gene;
Hubmayr, Johhannes;
Irwin, Kent;
Reintsema, Carl;
Baccigalupi, Carlo;
Leach, Sam;
Johnson, Bradley;
Lee, Adrian;
Tran, Huan;
Levinson, Lorne
Submitted: 2010-05-18
We describe the cryostat and supporting electronics for the EBEX experiment.
EBEX is a balloon-borne polarimeter designed to measure the B-mode polarization
of the cosmic microwave background radiation. The instrument includes a 1.5
meter Gregorian-type telescope and 1432 bolometric transition edge sensor
detectors operating at 0.3 K. Electronics for monitoring temperatures and
controlling cryostat refrigerators is read out over CANbus. A timing system
ensures the data from all subsystems is accurately synchronized. EBEX completed
an engineering test flight in June 2009 during which the cryogenics and
supporting electronics performed according to predictions. The temperatures of
the cryostat were stable, and an analysis of a subset of the data finds no scan
synchronous signal in the cryostat temperatures. Preparations are underway for
an Antarctic flight.
[15]
oai:arXiv.org:0908.1997 [pdf] - 27304
Design and characterization of TES bolometers and SQUID readout
electronics for a balloon-borne application
Hubmayr, Johannes;
Aubin, Francois;
Bissonnette, Eric;
Dobbs, Matt;
Hanany, Shaul;
Lee, Adrian T.;
MacDermid, Kevin;
Meng, Xiaofan;
Sagiv, Ilan;
Smecher, Graeme
Submitted: 2009-08-13
We present measurements of the electrical and thermal properties of new
arrays of bolometeric detectors that were fabricated as part of a program to
develop bolometers optimized for the low photon background of the EBEX
balloon-borne experiment. An array consists of 140 spider-web transition edge
sensor bolometers microfabricated on a 4" diameter silicon wafer. The designed
average thermal conductance of bolometers on a proto-type array is 32 pW/K, and
measurements are in good agreement with this value. The measurements are taken
with newly developed, digital frequency domain multiplexer SQUID readout
electronics.