Rundquist, Nils-Erik
Normalized to: Rundquist, N.
2 article(s) in total. 22 co-authors, from 1 to 2 common article(s). Median position in authors list is 2,0.
[1]
oai:arXiv.org:1808.07495 [pdf] - 1737988
The Infrared Imaging Spectrograph (IRIS) for TMT: advancing the data
reduction system
Walth, Gregory L.;
Wright, Shelley A.;
Rundquist, Nils-Erik;
Andersen, David;
Chapin, Edward;
Chisholm, Eric;
Do, Tuan;
Dunn, Jennifer;
Ellerbroek, Brent;
Gillies, Kim;
Hayano, Yutaka;
Johnson, Chris;
Larkin, James;
Nakamoto, Takashi;
Riddle, Reed;
Simard, Luc;
Smith, Roger;
Suzuki, Ryuji;
Sohn, Ji Man;
Weber, Robert;
Weissd, Jason;
Zhang, Kai
Submitted: 2018-08-22
Infrared Imaging Spectrograph (IRIS) is the first light instrument for the
Thirty Meter Telescope (TMT) that consists of a near-infrared (0.84 to 2.4
micron) imager and integral field spectrograph (IFS) which operates at the
diffraction-limit utilizing the Narrow-Field Infrared Adaptive Optics System
(NFIRAOS). The imager will have a 34 arcsec x 34 arcsec field of view with 4
milliarcsecond (mas) pixels. The IFS consists of a lenslet array and slicer,
enabling four plate scales from 4 mas to 50 mas, multiple gratings and filters,
which in turn will operate hundreds of individual modes. IRIS, operating in
concert with NFIRAOS will pose many challenges for the data reduction system
(DRS). Here we present the updated design of the real-time and post-processing
DRS. The DRS will support two modes of operation of IRIS: (1) writing the raw
readouts sent from the detectors and performing the sampling on all of the
readouts for a given exposure to create a raw science frame; and (2) reduction
of data from the imager, lenslet array and slicer IFS. IRIS is planning to save
the raw readouts for a given exposure to enable sophisticated processing
capabilities to the end users, such as the ability to remove individual poor
seeing readouts to improve signal-to-noise, or from advanced knowledge of the
point spread function (PSF). The readout processor (ROP) is a key part of the
IRIS DRS design for writing and sampling of the raw readouts into a raw science
frame, which will be passed to the TMT data archive. We discuss the use of
sub-arrays on the imager detectors for saturation/persistence mitigation,
on-detector guide windows, and fast readout science cases (< 1 second).
[2]
oai:arXiv.org:1808.07497 [pdf] - 1737990
The InfraRed Imaging Spectrograph (IRIS) for TMT: photometric precision
and ghost analysis
Rundquist, Nils;
Walth, Gregory;
Wright, Shelley A.;
Suzuki, Ryuji;
Do, Tuan;
Chapin, Edward L.;
Chisholm, Eric;
Dunn, Jennifer;
Hayano, Yutaka;
Johnson, Chris;
Larkin, James E.;
Riddle, Reed L.;
Schoeck, Matthias;
Sohn, Ji Man
Submitted: 2018-08-22
The InfraRed Imaging Spectrograph (IRIS) is a first-light instrument for the
Thirty Meter Telescope (TMT) that will be used to sample the corrected adaptive
optics field by NFIRAOS with a near-infrared (0.8 - 2.4 $\mu$m) imaging camera
and Integral Field Spectrograph (IFS). In order to understand the science case
specifications of the IRIS instrument, we use the IRIS data simulator to
characterize photometric precision and accuracy of the IRIS imager. We present
the results of investigation into the effects of potential ghosting in the IRIS
optical design. Each source in the IRIS imager field of view results in ghost
images on the detector from IRIS's wedge filters, entrance window, and
Atmospheric Dispersion Corrector (ADC) prism. We incorporated each of these
ghosts into the IRIS simulator by simulating an appropriate magnitude point
source at a specified pixel distance, and for the case of the extended ghosts
redistributing flux evenly over the area specified by IRIS's optical design. We
simulate the ghosting impact on the photometric capabilities, and found that
ghosts generally contribute negligible effects on the flux counts for point
sources except for extreme cases where ghosts coalign with a star of
$\Delta$m$>$2 fainter than the ghost source. Lastly, we explore the photometric
precision and accuracy for single sources and crowded field photometry on the
IRIS imager.