Normalized to: Rudyk, T.
[1]
oai:arXiv.org:1806.06843 [pdf] - 1762974
The Remarkable Be+sdOB Binary HD 55606 I: Orbital and Stellar Parameters
Chojnowski, S. Drew;
Labadie-Bartz, Jonathan;
Rivinius, Thomas;
Gies, Douglas;
Panoglou, Despina;
Fernandes, Marcelo Borges;
Wisniewski, John P.;
Whelan, David G.;
Mennickent, Ronald E.;
McMillan, Russet;
Dembicky, Jack M.;
Gray, Candace;
Rudyk, Ted;
Stringfellow, Guy S.;
Lester, Kathryn;
Hasslequist, Sten;
Zharikov, Sergey;
Levenhagen, Ronaldo;
Souza, Tiago;
Leister, Nelson;
Staussan, Keivan;
Siverd, Robert J.;
Majewski, Steven R.
Submitted: 2018-06-18
Prompted by peculiar spectroscopic variability observed in SDSS/APOGEE
$H$-band spectra, we monitored the Be star HD 55606 using optical spectroscopy
and found that it is an exotic double-lined spectroscopic binary (SB2)
consisting of a Be star and a hot, compact companion that is probably an OB
subdwarf (sdOB) star. Motion of the sdOB star is traced by its impact on the
strong He~I lines, observed as radial velocity ($V_{r}$) variable,
double-peaked emission profiles with narrow central absorption cores. Weak He
II 4686 {\AA} absorption associated with the companion star is detected in most
spectra. Use of the emission peaks of low-ionization emission lines to trace
the Be star $V_{r}$ and the He I lines to trace the companion star $V_{r}$
yields a circular orbital solution with a 93.8-day period and masses of $M_{\rm
Be}=6.2$ $M_{\rm \odot}$ and $M_{\rm sdOB}=0.9$ $M_{\rm \odot}$ in the case of
$i=80^{\circ}$. HD 55606 exhibits a variety of phase-locked variability,
including the development of shell lines twice per orbit. The shell phases
coincide with variation in the double emission peak separations, and both forms
of variability are likely caused by a two-armed spiral density perturbation in
the Be disk. The intensity ratios of the double emission peaks are also
phase-locked, possibly indicating heating by the sdOB star of the side of the
Be disk facing it. HD 55606 is a new member of the growing sample of Be+sdOB
binaries, in which the Be star's rapid rotation and ability to form a disk can
be attributed to past mass transfer.
[2]
oai:arXiv.org:1710.01790 [pdf] - 1589309
Towards Space-like Photometric Precision from the Ground with
Beam-Shaping Diffusers
Stefansson, Gudmundur;
Mahadevan, Suvrath;
Hebb, Leslie;
Wisniewski, John;
Huehnerhoff, Joseph;
Morris, Brett;
Halverson, Sam;
Zhao, Ming;
Wright, Jason;
O'rourke, Joseph;
Knutson, Heather;
Hawley, Suzanne;
Kanodia, Shubham;
Li, Yiting;
Hagen, Lea M. Z.;
Liu, Leo J.;
Beatty, Thomas;
Bender, Chad;
Robertson, Paul;
Dembicky, Jack;
Gray, Candace;
Ketzeback, William;
McMillan, Russet;
Rudyk, Theodore
Submitted: 2017-10-04
We demonstrate a path to hitherto unachievable differential photometric
precisions from the ground, both in the optical and near-infrared (NIR), using
custom-fabricated beam-shaping diffusers produced using specialized
nanofabrication techniques. Such diffusers mold the focal plane image of a star
into a broad and stable top-hat shape, minimizing photometric errors due to
non-uniform pixel response, atmospheric seeing effects, imperfect guiding, and
telescope-induced variable aberrations seen in defocusing. This PSF reshaping
significantly increases the achievable dynamic range of our observations,
increasing our observing efficiency and thus better averages over
scintillation. Diffusers work in both collimated and converging beams. We
present diffuser-assisted optical observations demonstrating
$62^{+26}_{-16}$ppm precision in 30 minute bins on a nearby bright star
16-Cygni A (V=5.95) using the ARC 3.5m telescope---within a factor of $\sim$2
of Kepler's photometric precision on the same star. We also show a transit of
WASP-85-Ab (V=11.2) and TRES-3b (V=12.4), where the residuals bin down to
$180^{+66}_{-41}$ppm in 30 minute bins for WASP-85-Ab---a factor of $\sim$4 of
the precision achieved by the K2 mission on this target---and to 101ppm for
TRES-3b. In the NIR, where diffusers may provide even more significant
improvements over the current state of the art, our preliminary tests have
demonstrated $137^{+64}_{-36}$ppm precision for a $K_S =10.8$ star on the 200"
Hale Telescope. These photometric precisions match or surpass the expected
photometric precisions of TESS for the same magnitude range. This technology is
inexpensive, scalable, easily adaptable, and can have an important and
immediate impact on the observations of transits and secondary eclipses of
exoplanets.