Normalized to: Rousselet-Perraut, K.
[1]
oai:arXiv.org:1501.05822 [pdf] - 925683
The GRAVITY instrument software / High-level software
Burtscher, Leonard;
Wieprecht, Ekkehard;
Ott, Thomas;
Kok, Yitping;
Yazici, Senol;
Anugu, Narsireddy;
Dembet, Roderick;
Fedou, Pierre;
Lacour, Sylvestre;
Ott, Juergen;
Paumard, Thibaut;
Lapeyrere, Vincent;
Kervella, Pierre;
Abuter, Roberto;
Pozna, Eszter;
Eisenhauer, Frank;
Blind, Nicolas;
Genzel, Reinhard;
Gillessen, Stefan;
Hans, Oliver;
Haug, Marcus;
Haussmann, Frank;
Kellner, Stefan;
Lippa, Magdalena;
Pfuhl, Oliver;
Sturm, Eckhard;
Weber, Johannes;
Amorim, Antonio;
Brandner, Wolfgang;
Rousselet-Perraut, Karine;
Perrin, Guy S.;
Straubmeier, Christian;
Schoeller, Markus
Submitted: 2015-01-23
GRAVITY is the four-beam, near- infrared, AO-assisted, fringe tracking,
astrometric and imaging instrument for the Very Large Telescope Interferometer
(VLTI). It is requiring the development of one of the most complex instrument
software systems ever built for an ESO instrument. Apart from its many
interfaces and interdependencies, one of the most challenging aspects is the
overall performance and stability of this complex system. The three infrared
detectors and the fast reflective memory network (RMN) recorder contribute a
total data rate of up to 20 MiB/s accumulating to a maximum of 250 GiB of data
per night. The detectors, the two instrument Local Control Units (LCUs) as well
as the five LCUs running applications under TAC (Tools for Advanced Control)
architecture, are interconnected with fast Ethernet, RMN fibers and dedicated
fiber connections as well as signals for the time synchronization. Here we give
a simplified overview of all subsystems of GRAVITY and their interfaces and
discuss two examples of high-level applications during observations: the
acquisition procedure and the gathering and merging of data to the final FITS
file.
[2]
oai:arXiv.org:1412.1696 [pdf] - 904702
The fiber coupler and beam stabilization system of the GRAVITY
interferometer
Pfuhl, O.;
Haug, M.;
Eisenhauer, F.;
Kellner, S.;
Haussmann, F.;
Perrin, G.;
Gillessen, S.;
Straubmeier, C.;
Ott, T.;
Rousselet-Perraut, K.;
Amorim, A.;
Lippa, M.;
Janssen, A.;
Brandner, W.;
Kok, Y.;
Blind, N.;
Burtscher, L.;
Sturm, E.;
Wieprecht, E.;
Schoeller, M.;
Weber, J.;
Hans, O.;
Huber, S.
Submitted: 2014-12-04
We present the installed and fully operational beam stabilization and fiber
injection subsystem feeding the 2nd generation VLTI instrument GRAVITY. The
interferometer GRAVITY requires an unprecedented stability of the VLTI optical
train to achieve micro-arcsecond astrometry. For this purpose, GRAVITY contains
four fiber coupler units, one per telescope. Each unit is equipped with
actuators to stabilize the telescope beam in terms of tilt and lateral pupil
displacement, to rotate the field, to adjust the polarization and to compensate
atmospheric piston. A special roof-prism offers the possibility of on-axis as
well as off-axis fringe tracking without changing the optical train. We
describe the assembly, integration and alignment and the resulting optical
quality and performance of the individual units. Finally, we present the
closed-loop performance of the tip-tilt and pupil tracking achieved with the
final systems in the lab.
[3]
oai:arXiv.org:1407.4281 [pdf] - 1215705
The interferometric baselines and GRAVITY astrometric error budget
Lacour, S.;
Eisenhauer, F.;
Gillessen, S.;
Pfuhl, O.;
Kok, Y.;
Perrin, G.;
Rousselet-Perraut, K.;
Straubmeier, C.;
Brandner, W.;
Amorim, A.;
Woillez, J.;
Bonnet, H.
Submitted: 2014-07-16
GRAVITY is a new generation beam combination instrument for the VLTI. Its
goal is to achieve microarsecond astrometric accuracy between objects separated
by a few arcsec. This $10^6$ accuracy on astrometric measurements is the most
important challenge of the instrument, and careful error budget have been
paramount during the technical design of the instrument. In this poster, we
will focus on baselines induced errors, which is part of a larger error budget.
[4]
oai:arXiv.org:0808.1397 [pdf] - 15292
Characterization of integrated optics components for the second
generation of VLTI instruments
Lacour, S.;
Jocou, L.;
Moulin, T.;
Labeye, P. R.;
Benisty, M.;
Berger, J. -P.;
Delboulbe, A.;
Haubois, X.;
Herwats, E.;
Kern, P. Y.;
Malbet, F.;
Rousselet-Perraut, K.;
Perrin, G.
Submitted: 2008-08-10
Two of the three instruments proposed to ESO for the second generation
instrumentation of the VLTI would use integrated optics for beam combination.
Several design are studied, including co-axial and multi-axial recombination.
An extensive quantity of combiners are therefore under test in our
laboratories. We will present the various components, and the method used to
validate and compare the different combiners. Finally, we will discuss the
performances and their implication for both VSI and Gravity VLTI instruments.
[5]
oai:arXiv.org:0709.4613 [pdf] - 5475
Asteroseismology and Interferometry
Cunha, M. S.;
Aerts, C.;
Christensen-Dalsgaard, J.;
Baglin, A.;
Bigot, L.;
Brown, T. M.;
Catala, C.;
Creevey, O. L.;
de Souza, A. Domiciano;
Eggenberger, P.;
Garcia, P. J. V.;
Grundahl, F.;
Kervella, P.;
Kurtz, D. W.;
Mathias, P.;
Miglio, A.;
Monteiro, M. J. P. F. G.;
Perrin, G.;
Pijpers, F. P.;
Pourbaix, D.;
Quirrenbach, A.;
Rousselet-Perraut, K.;
Teixeira, T. C.;
Thevenin, F.;
Thompson, M. J.
Submitted: 2007-09-28, last modified: 2008-04-16
Asteroseismology provides us with a unique opportunity to improve our
understanding of stellar structure and evolution. Recent developments,
including the first systematic studies of solar-like pulsators, have boosted
the impact of this field of research within Astrophysics and have led to a
significant increase in the size of the research community. In the present
paper we start by reviewing the basic observational and theoretical properties
of classical and solar-like pulsators and present results from some of the most
recent and outstanding studies of these stars. We centre our review on those
classes of pulsators for which interferometric studies are expected to provide
a significant input. We discuss current limitations to asteroseismic studies,
including difficulties in mode identification and in the accurate determination
of global parameters of pulsating stars, and, after a brief review of those
aspects of interferometry that are most relevant in this context, anticipate
how interferometric observations may contribute to overcome these limitations.
Moreover, we present results of recent pilot studies of pulsating stars
involving both asteroseismic and interferometric constraints and look into the
future, summarizing ongoing efforts concerning the development of future
instruments and satellite missions which are expected to have an impact in this
field of research.
[6]
oai:arXiv.org:astro-ph/0607291 [pdf] - 1455137
VSI: a milli-arcsec spectro-imager for the VLTI
Malbet, Fabien;
Kern, Pierre;
Berger, Jean-Philippe;
Jocou, Laurent;
Garcia, Paulo;
Buscher, David;
Rousselet-Perraut, Karine;
Weigelt, Gerd;
Gai, Mario;
Surdej, Jean;
Hron, Josef;
Neuhäuser, Ralph;
Coarer, Etienne Le;
Labeye, Pierre;
Bouquin, Jean-Baptiste Le;
Benisty, Myriam;
Herwats, Emilie
Submitted: 2006-07-13
VLTi Spectro-Imager (VSI) is a proposition for a second generation VLTI
instrument which is aimed at providing the ESO community with the capability of
performing image synthesis at milli-arcsecond angular resolution. VSI provides
the VLTI with an instrument able to combine 4 telescopes in a baseline version
and optionally up to 6 telescopes in the near-infrared spectral domain with
moderate to high spectral resolution. The instrument contains its own fringe
tracker in order to relax the constraints onto the VLTI infrastructure. VSI
will do imaging at the milli-arcsecond scale with spectral resolution of: a)
the close environments of young stars probing the initial conditions for planet
formation; b) the surfaces of stars; c) the environment of evolved stars,
stellar remnants and stellar winds, and d) the central region of active
galactic nuclei and supermassive black holes. The science cases allowed us to
specify the astrophysical requirements of the instrument and to define the
necessary studies of the science group for phase A.
[7]
oai:arXiv.org:astro-ph/0512544 [pdf] - 78744
Integrated optics for astronomical interferometry - VI. Coupling the
light of the VLTI in K band
Bouquin, Jean-Baptiste Le;
Labeye, Pierre;
Malbet, Fabien;
Jocou, Laurent;
Zabihian, Fatemeh;
Rousselet-Perraut, Karine;
Berger, Jean-Philippe;
Delboulbe, Alain;
Kern, Pierre;
Glindemann, Andreas;
Schoeller, Markus
Submitted: 2005-12-21
Our objective is to prove that integrated optics (IO) is not only a good
concept for astronomical interferometry but also a working technique with high
performance. We used the commissioning data obtained with the dedicated K-band
integrated optics two-telescope beam combiner which now replaces the fiber
coupler MONA in the VLTI/VINCI instrument. We characterize the behaviour of
this IO device and compare its properties to other single mode beam combiner
like the previously used MONA fiber coupler. The IO combiner provides a high
optical throughput, a contrast of 89% with a night-to-night stability of a few
percent. Even if a dispersive phase is present, we show that it does not bias
the measured Fourier visibility estimate. An upper limit of 0.005 for the
cross-talk between linear polarization states has been measured. We take
advantage of the intrinsic contrast stability to test a new astronomical
prodecure for calibrating diameters of simple stars by simultaneously fitting
the instrumental contrast and the apparent stellar diameters. This method
reaches an accuracy with diameter errors of the order of previous ones but
without the need of an already known calibrator. These results are an important
step of integrated optics and paves the road to incoming imaging interferometer
projects.
[8]
oai:arXiv.org:astro-ph/9907032 [pdf] - 107257
Integrated optics for astronomical interferometry. II. First laboratory
white-light interferograms
Submitted: 1999-07-02
We report first white-light interferograms obtained with an integrated optics
beam combiner on a glass plate. These results demonstrate the feasability of
single-mode interferometric beam combination with integrated optics technology
presented and discussed in paper I. The demonstration is achieved in laboratory
with off-the-shelves components coming from micro-sensor applications, not
optimized for astronomical use. These two-telescope beam combiners made by ion
exchange technique on glass substrate provide laboratory white-light
interferograms simultaneously with photometric calibration. A dedicated
interferometric workbench using optical fibers is set up to characterize these
devices. Despite the rather low match of the component parameters to
astronomical constraints, we obtain stable contrasts higher than 93% with a
1.54-\micron laser source and up to 78% with a white-light source in the
astronomical H band. Global throughput of 27% for a potassium ion exchange beam
combiner and of 43% for a silver one are reached. This work validates our
approach for combining several stellar beams of a long baseline interferometer
with integrated optics components.
[9]
oai:arXiv.org:astro-ph/9907031 [pdf] - 107256
Integrated optics for astronomical interferometry. I. Concept and
astronomical applications
Submitted: 1999-07-02
We propose a new instrumental concept for long-baseline optical single-mode
interferometry using integrated optics which were developed for
telecommunication. Visible and infrared multi-aperture interferometry requires
many optical functions (spatial filtering, beam combination, photometric
calibration, polarization control) to detect astronomical signals at very high
angular resolution. Since the 80's, integrated optics on planar substrate have
become available for telecommunication applications with multiple optical
functions like power dividing, coupling, multiplexing, etc. We present the
concept of an optical / infrared interferometric instrument based on this new
technology. The main advantage is to provide an interferometric combination
unit on a single optical chip. Integrated optics are compact, provide
stability, low sensitivity to external constrains like temperature, pressure or
mechanical stresses, no optical alignment except for coupling, simplicity and
intrinsic polarization control. The integrated optics devices are inexpensive
compared to devices that have the same functionalities in bulk optics. We think
integrated optics will fundamentally change single-mode interferometry.
Integrated optics devices are in particular well-suited for interferometric
combination of numerous beams to achieve aperture synthesis imaging or for
space-based interferometers where stability and a minimum of optical alignments
are wished.