Normalized to: Roth, S.
[1]
oai:arXiv.org:1703.07152 [pdf] - 1648551
Low-Temperature Relative Reflectivity Measurements of Reflective and
Scintillating Foils used in Rare Event Searches
Langenkämper, A.;
Ulrich, A.;
Defay, X.;
Feilitzsch, F. v.;
Lanfranchi, J. -C.;
Mondragón, E.;
Münster, A.;
Oppenheimer, C.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Steiger, H.;
Thi, H. H. Trinh;
Wawoczny, S.;
Willers, M.;
Zöller, A.
Submitted: 2017-03-21, last modified: 2017-12-20
In this work we investigate the reflectivity of highly reflective multilayer
polymer foils used in the CRESST experiment. The CRESST experiment searches
directly for dark matter via operating scintillating CaWO$_4$ crystals as
targets for elastic dark matter-nucleon scattering. In order to suppress
background events, the experiment employs the so-called phonon-light technique
which is based on the simultaneous measurement of the heat signal in the main
CaWO$_4$ target crystal and of the emitted scintillation light with a separate
cryogenic light detector. Both detectors are surrounded by a highly reflective
and scintillating multilayer polymer foil to increase the light collection
efficiency and to veto surface backgrounds. While this study is motivated by
the CRESST experiment, the results are also relevant for other rare event
searches using scintillating cryogenic bolometers in the field of the search of
dark matter and neutrinoless double beta decay ($0\nu\beta\beta$). In this work
a dedicated experiment has been set up to determine the relative reflectivity
at 300 K and 20 K of three multilayer foils ("VM2000", "VM2002", "Vikuiti")
produced by the company 3M. The intensity of a light beam reflected off the
foil is measured with a CCD camera. The ratio of the intensities at 300 K and
20 K corresponds to the relative reflectivity change. The measurements
performed in this work show no significant change in the reflectivity with
temperature for all foils studied.
[2]
oai:arXiv.org:1706.04934 [pdf] - 1604802
First results from the NEWS-G direct dark matter search experiment at
the LSM
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Asner, D.;
Bard, J. -P.;
Brossard, A.;
Cai, B.;
Chapellier, M.;
Clark, M.;
Corcoran, E. C.;
Dandl, T.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Gorel, P.;
Gros, M.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Navick, X. -F.;
Papaevangelou, T.;
Piquemal, F.;
Roth, S.;
Santos, D.;
Savvidis, I.;
Ulrich, A.;
Fernandez, F. Vazquez de Sola;
Zampaolo, M.
Submitted: 2017-06-15, last modified: 2017-09-07
New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection
experiment using Spherical Proportional Counters (SPCs) with light noble gases
to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report
the results from the first physics run taken at the Laboratoire Souterrain de
Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a
mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total
exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the
spin-independent WIMP-nucleon scattering cross-section in the
sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times
\mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5
$\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are
promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to
be installed at SNOLAB by summer 2018.
[3]
oai:arXiv.org:1503.07806 [pdf] - 1530245
In-situ study of light production and transport in phonon/light detector
modules for dark matter search
Kiefer, M.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-03-26, last modified: 2017-02-20
The CRESST experiment (Cryogenic Rare Event Search with Superconducting
Thermometers) searches for dark matter via the phonon and light signals of
elastic scattering processes in scintillating crystals. The discrimination
between a possible dark matter signal and background is based on the light
yield. We present a new method for evaluating the two characteristics of a
phonon/light detector module that determine how much of the deposited energy is
converted to scintillation light and how efficiently a module detects the
produced light. In contrast to former approaches with dedicated setups, we
developed a method which allows us to use data taken with the cryogenic setup,
during a dark matter search phase. In this way, we accounted for the entire
process that occurs in a detector module, and obtained information on the light
emission of the crystal as well as information on the performance of the module
(light transport and detection). We found that with the detectors operated in
CRESST-II phase 1, about 20% of the produced scintillation light is detected. A
part of the light is likely absorbed by creating meta-stable excitations in the
scintillating crystals. The light not detected is not absorbed entirely, as an
additional light detector can help to increase the fraction of detected light.
[4]
oai:arXiv.org:1401.3332 [pdf] - 1345758
Energy-Dependent Light Quenching in CaWO$_4$ Crystals at mK Temperatures
Strauss, R.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Carli, W.;
Ciemniak, C.;
Erb, A.;
Feilitzsch, F. v.;
Gorla, P.;
Gütlein, A.;
Hagn, H.;
Hauff, D.;
Hellgartner, D.;
Jochum, J.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stodolsky, L.;
Strandhagen, C.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-01-14, last modified: 2016-01-25
Scintillating CaWO$_4$ single crystals are a promising multi-element target
for rare-event searches and are currently used in the direct Dark Matter
experiment CRESST (Cryogenic Rare Event Search with Superconducting
Thermometers). The relative light output of different particle interactions in
CaWO$_4$ is quantified by Quenching Factors (QFs). These are essential for an
active background discrimination and the identification of a possible signal
induced by weakly interacting massive particles (WIMPs). We present the first
precise measurements of the QFs of O, Ca and W at mK temperatures by
irradiating a cryogenic detector with a fast neutron beam. A clear energy
dependence of the QF of O and, less pronounced, of Ca was observed for the
first time. Furthermore, in CRESST neutron-calibration data a variation of the
QFs among different CaWO$_4$ single crystals was found. For typical CRESST
detectors the QFs in the region-of-interest (10-40$\,$keV) are
$QF_O^{ROI}=(11.2{\pm}0.5)\,$%, $QF_{Ca}^{ROI}=(5.94{\pm}0.49)\,$% and
$QF_W^{ROI}=(1.72{\pm}0.21)\,$%. The latest CRESST data (run32) is reanalyzed
using these fundamentally new results on light quenching in CaWO$_4$ having
moderate influence on the WIMP analysis. Their relevance for future CRESST runs
and for the clarification of previously published results of direct Dark Matter
experiments is emphasized.
[5]
oai:arXiv.org:1410.1753 [pdf] - 1345768
A detector module with highly efficient surface-alpha event rejection
operated in CRESST-II Phase 2
Strauss, R.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Ferreiro, N.;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stanger, M.;
Stodolsky, L.;
Strandhagen, C.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-10-07, last modified: 2016-01-25
The cryogenic dark matter experiment CRESST-II aims at the direct detection
of WIMPs via elastic scattering off nuclei in scintillating CaWO$_4$ crystals.
We present a new, highly improved, detector design installed in the current run
of CRESST-II Phase 2 with an efficient active rejection of surface-alpha
backgrounds. Using CaWO$_4$ sticks instead of metal clamps to hold the target
crystal, a detector housing with fully-scintillating inner surface could be
realized. The presented detector (TUM40) provides an excellent threshold of
${\sim}\,0.60\,$keV and a resolution of $\sigma\,{\approx}\,0.090$ keV (at
2.60$\,$keV). With significantly reduced background levels, TUM40 sets
stringent limits on the spin-independent WIMP-nucleon scattering cross section
and probes a new region of parameter space for WIMP masses below
3$\,$GeV/c$^2$. In this paper, we discuss the novel detector design and the
surface-alpha event rejection in detail.
[6]
oai:arXiv.org:1511.07723 [pdf] - 1317179
Intense Vacuum-Ultraviolet and Infrared Scintillation of Liquid Ar-Xe
Mixtures
Neumeier, A.;
Dandl, T.;
Heindl, T.;
Himpsl, A.;
Oberauer, L.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Wieser, J.;
Ulrich, A.
Submitted: 2015-11-24
Vacuum ultraviolet light emission from xenon-doped liquid argon is described
in the context of liquid noble gas particle detectors. Xenon concentrations in
liquid argon from 0.1 ppm to 1000 ppm were studied. The energy transfer from
the second excimer continuum of argon ($\sim$127 nm) to the second excimer
continuum of xenon ($\sim$174 nm) is observed by recording optical emission
spectra. The transfer almost saturates at a xenon concentration of $\sim$10 ppm
for which, in addition, an intense emission in the infrared at a peak
wavelength of 1.17 $\mu$m with (13000$\pm$4000) photons per MeV deposited by
electrons had been found. The corresponding value for the VUV emission at a
peak wavelength of 174 nm (second excimer continuum of xenon) is determined to
be (20000$\pm$6000) photons per MeV electron energy deposited. Under these
excitation conditions pure liquid argon emits (22000$\pm$3000) photons per MeV
electron energy deposited at a peak wavelength of 127nm. An electron-beam
induced emission spectrum for the 10 ppm Ar-Xe liquid mixture ranging from 115
nm to 3.5 $\mu$m is presented. VUV emission spectra from xenon-doped liquid
argon with exponentially varied xenon concentrations from 0.1 ppm to 1000 ppm
are also shown. Time structure measurements of the light emissions at
well-defined wavelength positions in the vacuum ultraviolet as well as in the
near-infrared are presented.
[7]
oai:arXiv.org:1511.07722 [pdf] - 1317178
Intense Infrared Scintillation of Liquid Ar-Xe Mixtures
Neumeier, A.;
Dandl, T.;
Heindl, T.;
Himpsl, A.;
Hagn, H.;
Hofmann, M.;
Oberauer, L.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Wieser, J.;
Ulrich, A.
Submitted: 2015-11-24
Intense infrared (IR) light emission from liquid Ar-Xe mixtures has been
observed using 12 keV electron-beam excitation. The emission peaks at a
wavelength of 1.18 $\mu$m and the half-width of the emission band is 0.1
$\mu$m. Maximum intensity has been found for a 10 ppm xenon admixture in liquid
argon. The conversion efficiency of electron beam-power to IR-light is about 1%
(10000 photons per MeV electron energy deposited). A possible application of
this intense IR emission for a new particle discrimination concept in liquid
noble gas detectors is discussed. No light emission was found for perfectly
purified liquid argon in the wavelength range from 0.5 to 3.5 $\mu$m on the
current level of sensitivity.
[8]
oai:arXiv.org:1511.07721 [pdf] - 1317177
Ion-beam excitation of liquid argon
Hofmann, M.;
Dandl, T.;
Heindl, T.;
Neumeier, A.;
Oberauer, L.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Wieser, J.;
Ulrich, A.
Submitted: 2015-11-24
The scintillation light of liquid argon has been recorded wavelength and time
resolved with very good statistics in a wavelength interval ranging from 118 nm
through 970 nm. Three different ion beams, protons, sulfur ions and gold ions,
were used to excite liquid argon. Only minor differences were observed in the
wavelength-spectra obtained with the different incident particles. Light
emission in the wavelength range of the third excimer continuum was found to be
strongly suppressed in the liquid phase. In time-resolved measurements, the
time structure of the scintillation light can be directly attributed to
wavelength in our studies, as no wavelength shifter has been used. These
measurements confirm that the singlet-to-triplet intensity ratio in the second
excimer continuum range is a useful parameter for particle discrimination,
which can also be employed in wavelength-integrated measurements as long as the
sensitivity of the detector system does not rise steeply for wavelengths longer
than 190 nm. Using our values for the singlet-to-triplet ratio down to low
energies deposited a discrimination threshold between incident protons and
sulfur ions as low as $\sim$2.5 keV seems possible, which represents the
principle limit for the discrimination of these two species in liquid argon.
[9]
oai:arXiv.org:1510.05787 [pdf] - 1296411
Low-Temperature Scintillation Properties of CaWO4 Crystals for
Rare-Event Searches
Sivers, M. v.;
Clark, M.;
Di Stefano, P. C. F.;
Erb, A.;
Gütlein, A.;
Lanfranchi, J. -C.;
Münster, A.;
Nadeau, P.;
Piquemal, M.;
Potzel, W.;
Roth, S.;
Schreiner, K.;
Strauss, R.;
Wawoczny, S.;
Willers, M.;
Zöller, A.
Submitted: 2015-10-20
In prospect of its application in cryogenic rare-event searches, we have
investigated the low-temperature scintillation properties of CaWO4 crystals
down to 3.4 K under {\alpha} and {\gamma} excitation. Concerning the
scintillation decay times, we observe a long component in the ms range which
significantly contributes to the light yield below 40K. For the first time we
have measured the temperature dependence of the {\alpha}/{\gamma}- ratio of the
light yield. This parameter which can be used to discriminate {\alpha} and
{\gamma} events in scintillating bolometers is found to be about 8-15% smaller
at low temperatures compared to room temperature.
[10]
oai:arXiv.org:1410.1573 [pdf] - 975597
Sensitivity of alkali halide scintillating calorimeters with particle
identification to investigate the DAMA dark matter detection claim
Submitted: 2014-10-06, last modified: 2015-04-07
Scintillating calorimeters are cryogenic detectors combining a measurement of
scintillation with one of phonons to provide particle identification. In view
of developing alkali halide devices of this type able to check the DAMA/LIBRA
claim for the observation of dark matter, we have simulated detector
performances to determine their sensitivity by two methods with little
model-dependence. We conclude that if performance of the phonon channel can be
brought in line with those of other materials, an exposure of 10 kg-days would
suffice to check the DAMA/LIBRA claim in standard astrophysical scenarios.
Additionally, a fairly modest array of 5 kg with background rejection would be
able to directly check the DAMA/LIBRA modulation result in 2 years.
[11]
oai:arXiv.org:1407.3146 [pdf] - 925077
Results on low mass WIMPs using an upgraded CRESST-II detector
CRESST Collaboration;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Huff, P.;
Jochum, J.;
Kiefer, M.;
Kister, C.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Schmaler, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-07-11, last modified: 2015-01-22
The CRESST-II cryogenic dark matter search aims for the detection of WIMPs
via elastic scattering off nuclei in CaWO$_4$ crystals. We present results from
a low-threshold analysis of a single upgraded detector module. This module
efficiently vetoes low energy backgrounds induced by $\alpha$-decays on inner
surfaces of the detector. With an exposure of \unit[29.35]{kg live days}
collected in 2013 we set a limit on spin-independent WIMP-nucleon scattering
which probes a new region of parameter space for WIMP masses below
\unit[3]{GeV/c$^2$}, previously not covered in direct detection searches. A
possible excess over background discussed for the previous CRESST-II phase 1
(from 2009 to 2011) is not confirmed.
[12]
oai:arXiv.org:1501.04617 [pdf] - 923076
Microscopic Model for the Scintillation-Light Generation and
Light-Quenching in CaWO$_4$ single crystals
Submitted: 2015-01-19
Scintillators are employed for particle detection and identification using
light-pulse shapes and light quenching factors. We developed a comprehensive
model describing the light generation and quenching in CaWO$_4$ single crystals
used for direct dark matter search. All observed particle-dependent
light-emission characteristics can be explained quantitatively, light-quenching
factors and light-pulse shapes are calculated on a microscopic basis. This
model can be extended to other scintillators such as inorganic crystal
scintillators, liquid noble gases or organic liquid scintillators.
[13]
oai:arXiv.org:1403.5114 [pdf] - 1175712
Radiopurity of CaWO$_4$ Crystals for Direct Dark Matter Search with
CRESST and EURECA
Münster, A.;
Sivers, M. v.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kraus, H.;
Lanfranchi, J. -C.;
Laubenstein, M.;
Loebell, J.;
Ortigoza, Y.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puimedon, J.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-03-20, last modified: 2014-05-07
The direct dark matter search experiment CRESST uses scintillating CaWO$_4$
single crystals as targets for possible WIMP scatterings. An intrinsic
radioactive contamination of the crystals as low as possible is crucial for the
sensitivity of the detectors. In the past CaWO$_4$ crystals operated in CRESST
were produced by institutes in Russia and the Ukraine. Since 2011 CaWO$_4$
crystals have also been grown at the crystal laboratory of the Technische
Universit\"at M\"unchen (TUM) to better meet the requirements of CRESST and of
the future tonne-scale multi-material experiment EURECA. The radiopurity of the
raw materials and of first TUM-grown crystals was measured by ultra-low
background $\gamma$-spectrometry. Two TUM-grown crystals were also operated as
low-temperature detectors at a test setup in the Gran Sasso underground
laboratory. These measurements were used to determine the crystals' intrinsic
$\alpha$-activities which were compared to those of crystals produced at other
institutes. The total $\alpha$-activities of TUM-grown crystals as low as 1.23
$\pm$ 0.06 mBq/kg were found to be significantly smaller than the activities of
crystals grown at other institutes typically ranging between ~15 mBq/kg and ~35
mBq/kg.
[14]
oai:arXiv.org:1206.1588 [pdf] - 526323
Influence of Annealing on the Optical and Scintillation Properties of
CaWO$_4$ Single Crystals
Sivers, M. v.;
Ciemniak, C.;
Erb, A.;
Feilitzsch, F. v.;
Gütlein, A.;
Lanfranchi, J. -C.;
Lepelmeier, J.;
Münster, A.;
Potzel, W.;
Roth, S.;
Strauss, R.;
Thalhammer, U.;
Wawoczny, S.;
Willers, M.;
Zöller, A.
Submitted: 2012-06-07
We investigate the influence of oxygen annealing on the room temperature
optical and scintillation properties of CaWO$_4$ single crystals that are being
produced for direct Dark Matter search experiments. The applied annealing
procedure reduces the absorption coefficient at the peak position of the
scintillation spectrum ($\sim430$ nm) by a factor of $\sim6$ and leads to an
even larger reduction of the scattering coefficient. Furthermore, the annealing
has no significant influence on the \emph{intrinsic} light yield. An additional
absorption occurring at $\sim400$ nm suggests the formation of O$^-$ hole
centers. Light-yield measurements at room temperature where one crystal surface
was mechanically roughened showed an increase of the \emph{measured} light
yield by $\sim40 %$ and an improvement of the energy resolution at 59.5 keV by
$\sim12 %$ for the annealed crystal. We ascribe this result to the reduction of
the absorption coefficient while the surface roughening is needed to compensate
for the also observed reduction of the scattering coefficient after annealing.
[15]
oai:arXiv.org:1203.6835 [pdf] - 1117668
The CRESST II Dark Matter Search
Stodolsky, Leo;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Bucci, C.;
Ciemniak, C.;
Deuter, G.;
Feilitzsch, F. v.;
Hauff, D.;
Huff, P.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Lanfranchi, J. C.;
Pfister, S.;
Petricca, F.;
Potzel, W.;
Proebst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schaeffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Sivers, M. v.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Zoeller, A.
Submitted: 2012-03-30
Direct Dark Matter detection with cryodetectors is briefly discussed, with
particular mention of the possibility of the identification of the recoil
nucleus. Preliminary results from the CREEST II Dark Matter search, with 730
kg-days of data, are presented. Major backgrounds and methods of identifying
and dealing with them are indicated.
[16]
oai:arXiv.org:1109.0702 [pdf] - 1083810
Results from 730 kg days of the CRESST-II Dark Matter Search
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Bucci, C.;
Ciemniak, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Huff, P.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Lanfranchi, J. -C.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
von Sivers, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauß, R.;
Tanzke, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Zöller, A.
Submitted: 2011-09-04
The CRESST-II cryogenic Dark Matter search, aiming at detection of WIMPs via
elastic scattering off nuclei in CaWO$_4$ crystals, completed 730 kg days of
data taking in 2011. We present the data collected with eight detector modules,
each with a two-channel readout; one for a phonon signal and the other for
coincidently produced scintillation light. The former provides a precise
measure of the energy deposited by an interaction, and the ratio of
scintillation light to deposited energy can be used to discriminate different
types of interacting particles and thus to distinguish possible signal events
from the dominant backgrounds. Sixty-seven events are found in the acceptance
region where a WIMP signal in the form of low energy nuclear recoils would be
expected. We estimate background contributions to this observation from four
sources: 1) "leakage" from the e/\gamma-band 2) "leakage" from the
\alpha-particle band 3) neutrons and 4) Pb-206 recoils from Po-210 decay. Using
a maximum likelihood analysis, we find, at a high statistical significance,
that these sources alone are not sufficient to explain the data. The addition
of a signal due to scattering of relatively light WIMPs could account for this
discrepancy, and we determine the associated WIMP parameters.
[17]
oai:arXiv.org:1009.3815 [pdf] - 231145
Solar and Atmospheric Neutrinos: Limitations for Direct Dark Matter
Searches
Gütlein, A.;
Potzel, W.;
Ciemniak, C.;
von Feilitzsch, F.;
Haag, N.;
Hofmann, M.;
Isaila, C.;
Lachenmaier, T.;
Lanfranchi, J. -C.;
Oberauer, L.;
Pfister, S.;
Roth, S.;
von Sivers, M.;
Strauß, R.;
Zöller, A.
Submitted: 2010-09-20, last modified: 2010-09-23
In experiments for direct dark matter searches, neutrinos coherently
scattering off nuclei can produce similar events as Weakly Interacting Massive
Particles (WIMPs). To reach sensitivities better than about 10^-10 pb for the
elastic WIMP nucleon spin-independent cross section in the zero-background
limit, energy thresholds for nuclear recoils should be >2.05 keV for CaWO_4,
>4.91 keV for Ge, >2.89 keV for Xe, >8.62 keV for Ar and >15.93 keV for Ne as
target material. Atmospheric neutrinos limit the achievable sensitivity for the
background-free direct dark matter search to >10^-12 pb.
[18]
oai:arXiv.org:0912.3689 [pdf] - 125372
Status of the CRESST Dark Matter Search
Schmaler, J.;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Lang, R. F.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2009-12-18
The CRESST experiment aims for a detection of dark matter in the form of
WIMPs. These particles are expected to scatter elastically off the nuclei of a
target material, thereby depositing energy on the recoiling nucleus. CRESST
uses scintillating CaWO4 crystals as such a target. The energy deposited by an
interacting particle is primarily converted to phonons which are detected by
transition edge sensors. In addition, a small fraction of the interaction
energy is emitted from the crystals in the form of scintillation light which is
measured in coincidence with the phonon signal by a separate cryogenic light
detector for each target crystal. The ratio of light to phonon energy permits
the discrimination between the nuclear recoils expected from WIMPs and events
from radioactive backgrounds which primarily lead to electron recoils. CRESST
has shown the success of this method in a commissioning run in 2007 and, since
then, further investigated possibilities for an even better suppression of
backgrounds. Here, we report on a new class of background events observed in
the course of this work. The consequences of this observation are discussed and
we present the current status of the experiment.
[19]
oai:arXiv.org:0912.3023 [pdf] - 902765
A Comprehensive Spectral Analysis of the X-Ray Pulsar 4U 1907+09 from
Two Observations with the Suzaku X-Ray Observatory
Rivers, E.;
Markowitz, A.;
Pottschmidt, K.;
Roth, S.;
Barragán, L.;
Fürst, F.;
Suchy, S.;
Kreykenbohm, I.;
Wilms, J.;
Rothschild, R.
Submitted: 2009-12-15
We present results from two observations of the wind-accreting X-ray pulsar
4U 1907+09 using the Suzaku observatory. The broadband time-averaged spectrum
allows us to examine the continuum emission of the source and the cyclotron
resonance scattering feature at ~19 keV. Additionally, using the narrow CCD
response of Suzaku near 6 keV allows us to study in detail the Fe K bandpass
and to quantify the Fe K beta line for this source for the first time. The
source is absorbed by fully-covering material along the line of sight with a
column density of NH ~2e22 /cm^2, consistent with a wind accreting geometry,
and a high Fe abundance (~3-4 x solar). Time and phase-resolved analyses allow
us to study variations in the source spectrum. In particular, dips found in the
2006 observation which are consistent with earlier observations occur in the
hard X-ray bandpass, implying a variation of the whole continuum rather than
occultation by intervening material, while a dip near the end of the 2007
observation occurs mainly in the lower energies implying an increase in NH
along the line of sight, perhaps indicating clumpiness in the stellar wind.
[20]
oai:arXiv.org:0912.0170 [pdf] - 971925
Composite CaWO4 Detectors for the CRESST-II Experiment
Kiefer, M.;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Lang, R. F.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2009-12-01
CRESST-II, standing for Cryogenic Rare Events Search with Superconducting
Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS
facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order
to detect WIMPs by elastic scattering off nuclei, generating phononic lattice
excitations and scintillation light. The thermometers used in the experiment
consist of a tungsten thin-film structure evaporated onto the CaWO4 absorber
crystal. The process of evaporation causes a decrease in the scintillation
light output. This, together with the need of a big-scale detector production
for the upcoming EURECA experiment lead to investigations for producing
thermometers on smaller crystals which are glued onto the absorber crystal. In
our Run 31 we tested composite detectors for the first time in the Gran Sasso
setup. They seem to produce higher light yields as hoped and could provide an
additional time based discrimination mechanism for low light yield clamp
events.
[21]
oai:arXiv.org:0905.4282 [pdf] - 24648
Electron and Gamma Background in CRESST Detectors
Lang, R. F.;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Majorovits, B.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2009-05-26
The CRESST experiment monitors 300g CaWO_4 crystals as targets for particle
interactions in an ultra low background environment. In this paper, we analyze
the background spectra that are recorded by three detectors over many weeks of
data taking. Understanding these spectra is mandatory if one wants to further
reduce the background level, and allows us to cross-check the calibration of
the detectors. We identify a variety of sources, such as intrinsic
contaminations due to primordial radioisotopes and cosmogenic activation of the
target material. In particular, we detect a 3.6keV X-ray line from the decay of
41-Ca with an activity of (26\pm4)\mu Bq, corresponding to a ratio
41-Ca/40-Ca=(2.2\pm0.3)\times10^{-16}.
[22]
oai:arXiv.org:0903.4687 [pdf] - 22801
Discrimination of Recoil Backgrounds in Scintillating Calorimeters
Lang, R. F.;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2009-03-26
The alpha decay of $\n{{}^{210}Po}$ is a dangerous background to rare event
searches. Here, we describe observations related to this alpha decay in the
Cryogenic Rare Event Search with Superconducting Thermometers (CRESST). We find
that lead nuclei show a scintillation light yield in our $\n{CaWO_4}$ crystals
of $0.0142\pm0.0013$ relative to electrons of the same energy. We describe a
way to discriminate this source of nuclear recoil background by means of a
scintillating foil, and demonstrate its effectiveness. This leads to an
observable difference in the pulse shape of the light detector, which can be
used to tag these events. Differences in pulse shape of the phonon detector
between lead and electron recoils are also extracted, opening the window to
future additional background suppression techniques based on pulse shape
discrimination in such experiments.
[23]
oai:arXiv.org:0809.1829 [pdf] - 16181
Commissioning Run of the CRESST-II Dark Matter Search
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Lang, R. F.;
Majorovits, B.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Proebst, F.;
Rau, W.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schaeffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2008-09-10, last modified: 2009-02-16
The CRESST cryogenic direct dark matter search at Gran Sasso, searching for
WIMPs via nuclear recoil, has been upgraded to CRESST-II by several changes and
improvements.We present the results of a commissioning run carried out in 2007.
The basic element of CRESST-II is a detector module consisting of a large (~
300 g) CaWO_4 crystal and a very sensitive smaller (~ 2 g) light detector to
detect the scintillation light from the CaWO_4.Information from light-quenching
factor studies allows the definition of a region of the energy-light yield
plane which corresponds to tungsten recoils. A neutron test is reported which
supports the principle of using the light yield to identify the recoiling
nucleus.
Data obtained with two detector modules for a total exposure of 48 kg-days
are presented. Judging by the rate of events in the "all nuclear recoils"
acceptance region the apparatus shows a factor ~ten improvement with respect to
previous results, which we attribute principally to the presence of the neutron
shield.
In the "tungsten recoils" acceptance region three events are found,
corresponding to a rate of 0.063 per kg-day. Standard assumptions on the dark
matter flux, coherent or spin independent interactions,then yield a limit for
WIMP-nucleon scattering of 4.8 \times 10^{-7}pb, at M{WIMP} ~50 GeV.
[24]
oai:arXiv.org:0810.0423 [pdf] - 17016
Cryogenic Composite Detectors for the Dark Matter Experiments CRESST and
EURECA
Roth, S.;
Ciemniak, C.;
Coppi, C.;
Feilitzsch, F. v.;
Guetlein, A.;
Isaila, C.;
Lanfranchi, J. -C.;
Pfister, S.;
Potzel, W.;
Westphal, W.
Submitted: 2008-10-02
Weakly Interacting Massive Particles (WIMPs) are candidates for non-baryonic
Dark Matter. WIMPs are supposed to interact with baryonic matter via scattering
off nuclei producing a nuclear recoil with energies up to a few 10 keV with a
very low interaction rate of ~10^(-6) events per kg of target material and day
in the energy region of interest. The Dark Matter experiment CRESST (Cryogenic
Rare Event Search with Superconducting Thermometers) and the EURECA project
(European Underground Rare Event Calorimeter Array) are aimed at the direct
detection of WIMPs with the help of very sensitive modularised cryogenic
detectors that basically consist of a transition edge sensor (TES) in
combination with a massive absorber crystal. In the CRESST experiment the
search for coherent WIMP-nucleon scattering events is validated by the
detection of two processes. In the scintillating absorber single crystal,
CaWO_4, heat (phonons) and scintillation light are produced and detected with
two independent cryogenic detectors: a phonon channel and a separate light
channel. The development of such cryogenic detectors and the potential
ton-scale production are investigated in this paper. To decouple the TES
production from the choice of the target material in order to avoid heating
cycles of the absorber crystal and to allow pretesting of the TESs, a composite
detector design (CDD) for the detector production has been developed and
studied. An existing thermal detector model has been extended to the CDD, in
order to investigate, understand, and optimize the performance of composite
detectors. This extended model, which has been worked out in detail, can be
expected to provide a considerable help when tailoring composite detectors to
the requirements of various experiments.
[25]
oai:arXiv.org:0810.0132 [pdf] - 16940
Neutron Scattering Facility for Characterization of CRESST and EURECA
Detectors at mK Temperatures
Lanfranchi, J. -C.;
Ciemniak, C.;
Coppi, C.;
von Feilitzsch, F.;
Gütlein, A.;
Hagn, H.;
Isaila, C.;
Jochum, J.;
Kimmerle, M.;
Pfister, S.;
Potzel, W.;
Rau, W.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Scholl, S.;
Usherov, I.;
Westphal, W.
Submitted: 2008-10-01
CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) is an
experiment located at the Gran Sasso underground laboratory and aimed at the
direct detection of dark matter in the form of WIMPs. The setup has just
completed a one year commissioning run in 2007 and is presently starting a
physics run with an increased target mass. Scintillating $\mathrm{CaWO_4}$
single crystals, operated at temperatures of a few millikelvin, are used as
target to detect the tiny nuclear recoil induced by a WIMP. The powerful
background identification and rejection of $\alpha$, e$^{-}$ and $\gamma$
events is realized via the simultaneous measurement of a phonon and a
scintillation signal generated in the $\mathrm{CaWO_4}$ crystal. However,
neutrons could still be misidentified as a WIMP signature. Therefore, a
detailed understanding of the individual recoil behaviour in terms of phonon
generation and scintillation light emission due to scattering on Ca, O or W
nuclei, respectively, is mandatory. The only setup which allows to perform such
measurements at the operating temperature of the CRESST detectors has been
installed at the Maier-Leibnitz-Accelerator Laboratory in Garching and is
presently being commissioned. The design of this neutron scattering facility is
such that it can also be used for other target materials, e.g.
$\mathrm{ZnWO_4}$, $\mathrm{PbWO_4}$ and others as foreseen in the framework of
the future multitarget tonne-scale experiment EURECA (European Underground Rare
Event Calorimeter Array).