Normalized to: Rossin, C.
[1]
oai:arXiv.org:1509.02725 [pdf] - 1274617
THERMAP: a mid-infrared spectro-imager for space missions to small
bodies in the inner solar system
Groussin, O.;
Licandro, J.;
Helbert, J.;
Reynaud, J. -L.;
Levacher, P.;
García-Talavera, M. Reyes;
Alí-Lagoa, V.;
Blanc, P. -E.;
Brageot, E.;
Davidsson, B.;
Delbó, M.;
Deleuze, M.;
Delsanti, A.;
Garcia, J. J. Diaz;
Dohlen, K.;
Ferrand, D.;
Green, S.;
Jorda, L.;
Álvarez, E. Joven;
Knollenberg, J.;
Kührt, E.;
Lamy, P.;
Lellouch, E.;
Merrer, J. Le;
Marty, B.;
Mas, G.;
Rossin, C.;
Rozitis, B.;
Sunshine, J.;
Vernazza, P.;
Vives, S.
Submitted: 2015-09-09
We present THERMAP, a mid-infrared (8-16 {\mu}m) spectro-imager for space
missions to small bodies in the inner solar system, developed in the framework
of the MarcoPolo-R asteroid sample return mission. THERMAP is very well suited
to characterize the surface thermal environment of a NEO and to map its surface
composition. The instrument has two channels, one for imaging and one for
spectroscopy: it is both a thermal camera with full 2D imaging capabilities and
a slit spectrometer. THERMAP takes advantage of the recent technological
developments of uncooled microbolometers detectors, sensitive in the
mid-infrared spectral range. THERMAP can acquire thermal images (8-18 {\mu}m)
of the surface and perform absolute temperature measurements with a precision
better than 3.5 K above 200 K. THERMAP can acquire mid-infrared spectra (8-16
{\mu}m) of the surface with a spectral resolution {\Delta}{\lambda} of 0.3
{\mu}m. For surface temperatures above 350 K, spectra have a signal-to-noise
ratio >60 in the spectral range 9-13 {\mu}m where most emission features occur.
[2]
oai:arXiv.org:1407.2406 [pdf] - 1215544
The Microchannel X-ray Telescope for the Gamma-Ray Burst mission SVOM
Gotz, D.;
Osborne, J.;
Cordier, B.;
Paul, J.;
Evans, P.;
Beardmore, A.;
Martindale, A.;
Willingale, R.;
O'Brien, P.;
Basa, S.;
Rossin, C.;
Godet, O.;
Webb, N.;
Greiner, J.;
Nandra, K.;
Meidinger, N.;
Perinati, E.;
Santangelo, A.;
Mercier, K.;
Gonzalez, F.
Submitted: 2014-07-09
We present the Microchannel X-ray Telescope, a new light and compact
focussing telescope that will be flying on the Sino-French SVOM mission
dedicated to Gamma-Ray Burst science. The MXT design is based on the coupling
of square pore micro-channel plates with a low noise pnCCD. MXT will provide an
effective area of about 50 cmsq, and its point spread function is expected to
be better than 3.7 arc min (FWHM) on axis. The estimated sensitivity is
adequate to detect all the afterglows of the SVOM GRBs, and to localize them to
better then 60 arc sec after five minutes of observation.
[3]
oai:arXiv.org:1209.1502 [pdf] - 1151211
The silicon micro-strip detector plane for the LOFT/Wide Field Monitor
Goldwurm, A.;
Ferrando, P.;
Götz, D.;
Laurent, P.;
Lebrun, F.;
Limousin, O.;
Basa, S.;
Bertoli, W.;
Delagnes, E.;
Dolgorouky, Y.;
Gevin, O.;
Gros, A.;
Gouiffes, C.;
Jeanneau, F.;
Lachaud, C.;
Llored, M.;
Olivetto, C.;
Prévôt, G.;
Renaud, D.;
Rodriguez, J.;
Rossin, C.;
Schanne, S.;
Soldi, S.;
Varniere, P.
Submitted: 2012-09-07
The main objective of the Wide Field Monitor (WFM) on the LOFT mission is to
provide unambiguous detection of the high-energy sources in a large field of
view, in order to support science operations of the LOFT primary instrument,
the LAD. The monitor will also provide by itself a large number of results on
the timing and spectral behaviour of hundreds of galactic compact objects,
Active Galactic Nuclei and Gamma-Ray Bursts. The WFM is based on the coded
aperture concept where a position sensitive detector records the shadow of a
mask projected by the celestial sources. The proposed WFM detector plane, based
on Double Sided micro-Strip Silicon Detectors (DSSD), will allow proper
2-dimensional recording of the projected shadows. Indeed the positioning of the
photon interaction in the detector with equivalent fine resolution in both
directions insures the best imaging capability compatible with the allocated
budgets for this telescope on LOFT. We will describe here the overall
configuration of this 2D-WFM and the design and characteristics of the DSSD
detector plane including its imaging and spectral performances. We will also
present a number of simulated results discussing the advantages that this
configuration offers to LOFT. A DSSD-based WFM will in particular reduce
significantly the source confusion experienced by the WFM in crowded regions of
the sky like the Galactic Center and will in general increase the observatory
science capability of the mission.
[4]
oai:arXiv.org:astro-ph/0010242 [pdf] - 387034
The AMS-01 Aerogel Threshold Cherenkov counter
Barancourt, D.;
Barao, F.;
Barbier, G.;
Barreira, G.;
Buenerd, M.;
Castellini, G.;
Choumilov, E.;
Favier, J.;
Fouque, N.;
Gougas, A.;
Hermel, V.;
Kossakowski, R.;
Laborie, G.;
Laurenti, G.;
Lee, S. -C.;
Mayet, F.;
Meillon, B.;
Oyang, Y. -T.;
Plyaskin, V.;
Pojidaev, V.;
Rossin, C.;
Santos, D.;
Vezzu, F.;
Vialle, J. P.
Submitted: 2000-10-12
The Alpha Magnetic Spectrometer in a precursor version (AMS-01), was flown in
June 1998 on a 51.6 degrees orbit and at altitudes ranging between 320 and 390
km, on board of the space shuttle Discovery (flight STS-91). AMS-01 included an
Aerogel Threshold Cherenkov counter (ATC) to separate antiprotons from
electrons and positrons from protons, for momenta below 3.5 GeV/c. This paper
presents a description of the ATC counter and reports on its performances
during the flight STS-91.