sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Rossi, Kayla

Normalized to: Rossi, K.

3 article(s) in total. 54 co-authors, from 1 to 3 common article(s). Median position in authors list is 17,0.

[1]  oai:arXiv.org:1908.10451  [pdf] - 2072556
Sensitivity of the Prime-Cam Instrument on the CCAT-prime Telescope
Comments: Version accepted for publication by Journal of Low Temperature Physics; updates on FPI detectors, more details given on sensitivity calculations
Submitted: 2019-08-27, last modified: 2020-03-31
CCAT-prime is a new 6 m crossed Dragone telescope designed to characterize the Cosmic Microwave Background (CMB) polarization and foregrounds, measure the Sunyaev-Zel'dovich effects of galaxy clusters, map the [CII] emission intensity from the Epoch of Reionization (EoR), and monitor accretion luminosity over multi-year timescales of hundreds of protostars in the Milky Way. CCAT-prime will make observations from a 5,600 m altitude site on Cerro Chajnantor in the Atacama Desert of northern Chile. The novel optical design of the telescope combined with high surface accuracy ($<$10 $\mu$m) mirrors and the exceptional atmospheric conditions of the site will enable sensitive broadband, polarimetric, and spectroscopic surveys at sub-mm to mm wavelengths. Prime-Cam, the first light instrument for CCAT-prime, consists of a 1.8 m diameter cryostat that can house seven individual instrument modules. Each instrument module, optimized for a specific science goal, will use state-of-the-art kinetic inductance detector (KID) arrays operated at $\sim$100 mK, and Fabry-Perot interferometers (FPI) for the EoR science. Prime-Cam will be commissioned with staged deployments to populate the seven instrument modules. The full instrument will consist of 60,000 polarimetric KIDs at a combination of 220/280/350/410 GHz, 31,000 KIDS at 250/360 GHz coupled with FPIs, and 21,000 polarimetric KIDs at 850 GHz. Prime-Cam is currently being built, and the CCAT-prime telescope is designed and under construction by Vertex Antennentechnik GmbH to achieve first light in 2021. CCAT-prime is also a potential telescope platform for the future CMB Stage-IV observations.
[2]  oai:arXiv.org:1808.05218  [pdf] - 1734754
Development of the Fabry-Perot interferometers for the HIRMES spectrometer on SOFIA
Comments: 13 pages, 10 figures, SPIE Conference Proceedings 2018
Submitted: 2018-08-15, last modified: 2018-08-17
HIRMES is a far-infrared spectrometer that was chosen as the third generation instrument for NASA's SOFIA airborne observatory. HIRMES promises background limited performance in four modes that cover the wavelength range between 25 and 122 $\mu$m. The high-spectral resolution ($R \approx 10^5$) mode is matched to achieve maximum sensitivity on velocity-resolved lines to study the evolution of protoplanetary disks. The mid-resolution ($R \approx 12, 000$) mode is suitable for high sensitivity imaging of galactic star formation regions in, for example, the several far-infrared fine structure lines. The low-resolution ($R \approx 2000$) imaging mode is optimized for spectroscopic mapping of far-infrared fine structure lines from nearby galaxies, while the low resolution ($R \approx 600$) grating spectrometer mode is optimized for detecting dust and ice features in protostellar and protoplanetary disks. Several Transition Edge Sensed (TES) bolometer arrays will provide background limited sensitivity in each of these modes. To optimize performance in the various instrument modes, HIRMES employs eight unique fully-tunable cryogenic Fabry-Perot Interferometers (FPIs) and a grating spectrometer. Here we present the design requirements and the mechanical and optical characteristics and performance of these tunable FPI as well as the control electronics that sets the mirror separation and allows scanning of the FPIs.
[3]  oai:arXiv.org:1807.00058  [pdf] - 1839608
Prime-Cam: A first-light instrument for the CCAT-prime telescope
Comments: Presented at SPIE Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy IX, June 15th, 2018
Submitted: 2018-06-29
CCAT-prime will be a 6-meter aperture telescope operating from sub-mm to mm wavelengths, located at 5600 meters elevation on Cerro Chajnantor in the Atacama Desert in Chile. Its novel crossed-Dragone optical design will deliver a high throughput, wide field of view capable of illuminating much larger arrays of sub-mm and mm detectors than can existing telescopes. We present an overview of the motivation and design of Prime-Cam, a first-light instrument for CCAT-prime. Prime-Cam will house seven instrument modules in a 1.8 meter diameter cryostat, cooled by a dilution refrigerator. The optical elements will consist of silicon lenses, and the instrument modules can be individually optimized for particular science goals. The current design enables both broadband, dual-polarization measurements and narrow-band, Fabry-Perot spectroscopic imaging using multichroic transition-edge sensor (TES) bolometers operating between 190 and 450 GHz. It also includes broadband kinetic induction detectors (KIDs) operating at 860 GHz. This wide range of frequencies will allow excellent characterization and removal of galactic foregrounds, which will enable precision measurements of the sub-mm and mm sky. Prime-Cam will be used to constrain cosmology via the Sunyaev-Zeldovich effects, map the intensity of [CII] 158 $\mu$m emission from the Epoch of Reionization, measure Cosmic Microwave Background polarization and foregrounds, and characterize the star formation history over a wide range of redshifts. More information about CCAT-prime can be found at www.ccatobservatory.org.