Normalized to: Rosser, J.
[1]
oai:arXiv.org:1802.06943 [pdf] - 1659719
Behavioral Characteristics and CO+CO2 Production Rates of Halley-Type
Comets Observed by NEOWISE
Rosser, Joshua D.;
Bauer, James M.;
Mainzer, Amy K.;
Kramer, Emily;
Masiero, Joseph R.;
Nugent, Carrie R.;
Sonnett, Sarah;
Fernandez, Yanga R.;
Ruecker, Kinjal;
Krings, Philip;
Wright, Edward L.
Submitted: 2018-02-19
From the entire dataset of comets observed by NEOWISE, we have analyzed 11
different Halley-Type Comets (HTCs) for dust production rates, CO+CO2
production rates, and nucleus sizes. Incorporating HTCs from previous studies
and multiple comet visits we have a total of 21 stacked visits, 13 of which are
active and 8 for which we calculated upper limits of production. We determined
the nucleus sizes of 27P, P/2006 HR30, P/2012 NJ, and C/2016 S1. Furthermore,
we analyzed the relationships between dust production and heliocentric
distance, and gas production and heliocentric distance. We concluded that for
this population of HTCs, ranging in heliocentric distance from 1.21 AU to 2.66
AU, there was no significant correlation between dust production and
heliocentric distance, nor gas production and heliocentric distance.
[2]
oai:arXiv.org:1608.04323 [pdf] - 1456182
Proton irradiation results for long-wave HgCdTe infrared detector arrays
for NEOCam
Submitted: 2016-08-15
HgCdTe detector arrays with a cutoff wavelength of ~10 ${\mu}$m intended for
the NEOCam space mission were subjected to proton beam irradiation at the
University of California Davis Crocker Nuclear Laboratory. Three arrays were
tested - one with 800 $\mu$m substrate intact, one with 30 $\mu$m substrate,
and one completely substrate-removed. The CdZnTe substrate, on which the HgCdTe
detector is grown, has been shown to produce luminescence in shorter wave
HgCdTe arrays that causes elevated signal in non-hit pixels when subjected to
proton irradiation. This testing was conducted to ascertain whether or not full
substrate removal is necessary. At the dark level of the dewar, we detect no
luminescence in non-hit pixels during proton testing for both the
substrate-removed detector array and the array with 30 ${\mu}$m substrate. The
detector array with full 800 ${\mu}$m substrate exhibited substantial
photocurrent for a flux of 103 protons/cm$^2$-s at a beam energy of 18.1 MeV (~
750 e$^-$/s) and 34.4 MeV ($\sim$ 65 e$^-$/s). For the integrated space-like
ambient proton flux level measured by the Spitzer Space Telescope, the
luminescence would be well below the NEOCam dark current requirement of <200
e$^-$/s, but the pattern of luminescence could be problematic, possibly
complicating calibration.