Normalized to: Rohr, J.
[1]
oai:arXiv.org:2002.05669 [pdf] - 2109017
Optical suppression of tilt-to-length coupling in the LISA long-arm
interferometer
Chwalla, M;
Danzmann, K;
Álvarez, M Dovale;
Delgado, J J Esteban;
Barranco, G Fernández;
Fitzsimons, E;
Gerberding, O;
Heinzel, G;
Killow, C J;
Lieser, M;
Perreur-Lloyd, M;
Robertson, D I;
Rohr, J M;
Schuster, S;
Schwarze, T S;
Tröbs, M;
Wanner, G;
Ward, H
Submitted: 2020-02-13, last modified: 2020-06-05
The arm length and the isolation in space enable LISA to probe for signals
unattainable on ground, opening a window to the sub-Hz gravitational-wave
universe. The coupling of unavoidable angular spacecraft jitter into the
longitudinal displacement measurement, an effect known as tilt-to-length (TTL)
coupling, is critical for realizing the required sensitivity of
picometer$/\sqrt{\rm{Hz}}$. An ultra-stable interferometer testbed has been
developed in order to investigate this issue and validate mitigation strategies
in a setup representative of LISA, and in this paper it is operated in the
long-arm interferometer configuration. The testbed is fitted with a flat-top
beam generator to simulate the beam received by a LISA spacecraft. We
demonstrate a reduction of TTL coupling between this flat-top beam and a
Gaussian reference beam via introducing two- and four-lens imaging systems. TTL
coupling factors below $\pm 25\,\mu$m/rad for beam tilts within $\pm
300\,\mu$rad are obtained by careful optimization of the system. Moreover we
show that the additional TTL coupling due to lateral alignment errors of
elements of the imaging system can be compensated by introducing lateral shifts
of the detector, and vice versa. These findings help validate the suitability
of this noise-reduction technique for the LISA long-arm interferometer.