Normalized to: Rohlfs, R.
[1]
oai:arXiv.org:2001.05587 [pdf] - 2057872
Expected performances of the Characterising Exoplanet Satellite (CHEOPS)
II. The CHEOPS simulator
Futyan, David;
Fortier, Andrea;
Beck, Mathias;
Ehrenreich, David;
Bekkelien, Anja;
Benz, Willy;
Billot, Nicolas;
Bourrier, Vincent;
Broeg, Christopher;
Cameron, Andrew Collier;
Deline, Adrien;
Kuntzer, Thibault;
Lendl, Monika;
Queloz, Didier;
Rohlfs, Reiner;
Simon, Attila E.;
Wildi, Francois
Submitted: 2020-01-15
The CHaracterising ExOPlanet Satellite (CHEOPS) is a mission dedicated to the
search for exoplanetary transits through high precision photometry of bright
stars already known to host planets. The telescope will provide the unique
capability of determining accurate radii for planets whose masses have already
been measured from ground-based spectroscopic surveys. This will allow a
first-order characterisation of the planets' internal structure through the
determination of the bulk density, providing direct insight into their
composition. The CHEOPS simulator has been developed to perform detailed
simulations of the data which is to be received from the CHEOPS satellite. It
generates accurately simulated images that can be used to explore design
options and to test the on-ground data processing, in particular, the pipeline
producing the photometric time series. It is, thus, a critical tool for
estimating the photometric performance expected in flight and to guide
photometric analysis. It can be used to prepare observations, consolidate the
noise budget, and asses the performance of CHEOPS in realistic astrophysical
fields that are difficult to reproduce in the laboratory. Images generated by
CHEOPSim take account of many detailed effects, including variations of the
incident signal flux and backgrounds, and detailed modelling of the satellite
orbit, pointing jitter and telescope optics, as well as the CCD response, noise
and readout. The simulator results presented in this paper have been used in
the context of validating the data reduction processing chain, in which image
time series generated by CHEOPSim were used to generate light curves for
simulated planetary transits across real and simulated targets. Independent
analysts were successfully able to detect the planets and measure their radii
to an accuracy within the science requirements of the mission.
[2]
oai:arXiv.org:1408.6526 [pdf] - 864022
The Large Observatory For x-ray Timing
Feroci, M.;
Herder, J. W. den;
Bozzo, E.;
Barret, D.;
Brandt, S.;
Hernanz, M.;
van der Klis, M.;
Pohl, M.;
Santangelo, A.;
Stella, L.;
Watts, A.;
Wilms, J.;
Zane, S.;
Ahangarianabhari, M.;
Albertus, C.;
Alford, M.;
Alpar, A.;
Altamirano, D.;
Alvarez, L.;
Amati, L.;
Amoros, C.;
Andersson, N.;
Antonelli, A.;
Argan, A.;
Artigue, R.;
Artigues, B.;
Atteia, J. -L.;
Azzarello, P.;
Bakala, P.;
Baldazzi, G.;
Balman, S.;
Barbera, M.;
van Baren, C.;
Bhattacharyya, S.;
Baykal, A.;
Belloni, T.;
Bernardini, F.;
Bertuccio, G.;
Bianchi, S.;
Bianchini, A.;
Binko, P.;
Blay, P.;
Bocchino, F.;
Bodin, P.;
Bombaci, I.;
Bidaud, J. -M. Bonnet;
Boutloukos, S.;
Bradley, L.;
Braga, J.;
Brown, E.;
Bucciantini, N.;
Burderi, L.;
Burgay, M.;
Bursa, M.;
Budtz-Jørgensen, C.;
Cackett, E.;
Cadoux, F. R.;
Cais, P.;
Caliandro, G. A.;
Campana, R.;
Campana, S.;
Capitanio, F.;
Casares, J.;
Casella, P.;
Castro-Tirado, A. J.;
Cavazzuti, E.;
Cerda-Duran, P.;
Chakrabarty, D.;
Château, F.;
Chenevez, J.;
Coker, J.;
Cole, R.;
Collura, A.;
Cornelisse, R.;
Courvoisier, T.;
Cros, A.;
Cumming, A.;
Cusumano, G.;
D'Aì, A.;
D'Elia, V.;
Del Monte, E.;
De Luca, A.;
De Martino, D.;
Dercksen, J. P. C.;
De Pasquale, M.;
De Rosa, A.;
Del Santo, M.;
Di Cosimo, S.;
Diebold, S.;
Di Salvo, T.;
Donnarumma, I.;
Drago, A.;
Durant, M.;
Emmanoulopoulos, D.;
Erkut, M. H.;
Esposito, P.;
Evangelista, Y.;
Fabian, A.;
Falanga, M.;
Favre, Y.;
Feldman, C.;
Ferrari, V.;
Ferrigno, C.;
Finger, M.;
Finger, M. H.;
Fraser, G. W.;
Frericks, M.;
Fuschino, F.;
Gabler, M.;
Galloway, D. K.;
Sanchez, J. L. Galvez;
Garcia-Berro, E.;
Gendre, B.;
Gezari, S.;
Giles, A. B.;
Gilfanov, M.;
Giommi, P.;
Giovannini, G.;
Giroletti, M.;
Gogus, E.;
Goldwurm, A.;
Goluchová, K.;
Götz, D.;
Gouiffes, C.;
Grassi, M.;
Groot, P.;
Gschwender, M.;
Gualtieri, L.;
Guidorzi, C.;
Guy, L.;
Haas, D.;
Haensel, P.;
Hailey, M.;
Hansen, F.;
Hartmann, D. H.;
Haswell, C. A.;
Hebeler, K.;
Heger, A.;
Hermsen, W.;
Homan, J.;
Hornstrup, A.;
Hudec, R.;
Huovelin, J.;
Ingram, A.;
Zand, J. J. M. in't;
Israel, G.;
Iwasawa, K.;
Izzo, L.;
Jacobs, H. M.;
Jetter, F.;
Johannsen, T.;
Jacobs, H. M.;
Jonker, P.;
Josè, J.;
Kaaret, P.;
Kanbach, G.;
Karas, V.;
Karelin, D.;
Kataria, D.;
Keek, L.;
Kennedy, T.;
Klochkov, D.;
Kluzniak, W.;
Kokkotas, K.;
Korpela, S.;
Kouveliotou, C.;
Kreykenbohm, I.;
Kuiper, L. M.;
Kuvvetli, I.;
Labanti, C.;
Lai, D.;
Lamb, F. K.;
Laubert, P. P.;
Lebrun, F.;
Lin, D.;
Linder, D.;
Lodato, G.;
Longo, F.;
Lund, N.;
Maccarone, T. J.;
Macera, D.;
Maestre, S.;
Mahmoodifar, S.;
Maier, D.;
Malcovati, P.;
Mandel, I.;
Mangano, V.;
Manousakis, A.;
Marisaldi, M.;
Markowitz, A.;
Martindale, A.;
Matt, G.;
McHardy, I. M.;
Melatos, A.;
Mendez, M.;
Mereghetti, S.;
Michalska, M.;
Migliari, S.;
Mignani, R.;
Miller, M. C.;
Miller, J. M.;
Mineo, T.;
Miniutti, G.;
Morsink, S.;
Motch, C.;
Motta, S.;
Mouchet, M.;
Mouret, G.;
Mulačová, J.;
Muleri, F.;
Muñoz-Darias, T.;
Negueruela, I.;
Neilsen, J.;
Norton, A. J.;
Nowak, M.;
O'Brien, P.;
Olsen, P. E. H.;
Orienti, M.;
Orio, M.;
Orlandini, M.;
Orleanski, P.;
Osborne, J. P.;
Osten, R.;
Ozel, F.;
Pacciani, L.;
Paolillo, M.;
Papitto, A.;
Paredes, J. M.;
Patruno, A.;
Paul, B.;
Perinati, E.;
Pellizzoni, A.;
Penacchioni, A. V.;
Perez, M. A.;
Petracek, V.;
Pittori, C.;
Pons, J.;
Portell, J.;
Possenti, A.;
Poutanen, J.;
Prakash, M.;
Provost, P. Le;
Psaltis, D.;
Rambaud, D.;
Ramon, P.;
Ramsay, G.;
Rapisarda, M.;
Rachevski, A.;
Rashevskaya, I.;
Ray, P. S.;
Rea, N.;
Reddy, S.;
Reig, P.;
Aranda, M. Reina;
Remillard, R.;
Reynolds, C.;
Rezzolla, L.;
Ribo, M.;
de la Rie, R.;
Riggio, A.;
Rios, A.;
Gil, P. Rodríguez-;
Rodriguez, J.;
Rohlfs, R.;
Romano, P.;
Rossi, E. M. R.;
Rozanska, A.;
Rousseau, A.;
Ryde, F.;
Sabau-Graziati, L.;
Sala, G.;
Salvaterra, R.;
Sanna, A.;
Sandberg, J.;
Scaringi, S.;
Schanne, S.;
Schee, J.;
Schmid, C.;
Shore, S.;
Schneider, R.;
Schwenk, A.;
Schwope, A. D.;
Seyler, J. -Y.;
Shearer, A.;
Smith, A.;
Smith, D. M.;
Smith, P. J.;
Sochora, V.;
Soffitta, P.;
Soleri, P.;
Spencer, A.;
Stappers, B.;
Steiner, A. W.;
Stergioulas, N.;
Stratta, G.;
Strohmayer, T. E.;
Stuchlik, Z.;
Suchy, S.;
Sulemainov, V.;
Takahashi, T.;
Tamburini, F.;
Tauris, T.;
Tenzer, C.;
Tolos, L.;
Tombesi, F.;
Tomsick, J.;
Torok, G.;
Torrejon, J. M.;
Torres, D. F.;
Tramacere, A.;
Trois, A.;
Turolla, R.;
Turriziani, S.;
Uter, P.;
Uttley, P.;
Vacchi, A.;
Varniere, P.;
Vaughan, S.;
Vercellone, S.;
Vrba, V.;
Walton, D.;
Watanabe, S.;
Wawrzaszek, R.;
Webb, N.;
Weinberg, N.;
Wende, H.;
Wheatley, P.;
Wijers, R.;
Wijnands, R.;
Wille, M.;
Wilson-Hodge, C. A.;
Winter, B.;
Wood, K.;
Zampa, G.;
Zampa, N.;
Zampieri, L.;
Zdunik, L.;
Zdziarski, A.;
Zhang, B.;
Zwart, F.;
Ayre, M.;
Boenke, T.;
van Damme, C. Corral;
Kuulkers, E.;
Lumb, D.
Submitted: 2014-08-27, last modified: 2014-08-29
The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3
Cosmic Vision framework and participated in the final down-selection for a
launch slot in 2022-2024. Thanks to the unprecedented combination of effective
area and spectral resolution of its main instrument, LOFT will study the
behaviour of matter under extreme conditions, such as the strong gravitational
field in the innermost regions of accretion flows close to black holes and
neutron stars, and the supra-nuclear densities in the interior of neutron
stars. The science payload is based on a Large Area Detector (LAD, 10 m 2
effective area, 2-30 keV, 240 eV spectral resolution, 1 deg collimated field of
view) and a WideField Monitor (WFM, 2-50 keV, 4 steradian field of view, 1
arcmin source location accuracy, 300 eV spectral resolution). The WFM is
equipped with an on-board system for bright events (e.g. GRB) localization. The
trigger time and position of these events are broadcast to the ground within 30
s from discovery. In this paper we present the status of the mission at the end
of its Phase A study.
[3]
oai:arXiv.org:1408.6541 [pdf] - 864033
The LOFT Ground Segment
Bozzo, E.;
Antonelli, A.;
Argan, A.;
Barret, D.;
Binko, P.;
Brandt, S.;
Cavazzuti, E.;
Courvoisier, T.;
Herder, J. W. den;
Feroci, M.;
Ferrigno, C.;
Giommi, P.;
Götz, D.;
Guy, L.;
Hernanz, M.;
Zand, J. J. M. in't;
Klochkov, D.;
Kuulkers, E.;
Motch, C.;
Lumb, D.;
Papitto, A.;
Pittori, C.;
Rohlfs, R.;
Santangelo, A.;
Schmid, C.;
Schwope, A. D.;
Smith, P. J.;
Webb, N. A.;
Wilms, J.;
Zane, S.
Submitted: 2014-08-27
LOFT, the Large Observatory For X-ray Timing, was one of the ESA M3 mission
candidates that completed their assessment phase at the end of 2013. LOFT is
equipped with two instruments, the Large Area Detector (LAD) and the Wide Field
Monitor (WFM). The LAD performs pointed observations of several targets per
orbit (~90 minutes), providing roughly ~80 GB of proprietary data per day (the
proprietary period will be 12 months). The WFM continuously monitors about 1/3
of the sky at a time and provides data for about ~100 sources a day, resulting
in a total of ~20 GB of additional telemetry. The LOFT Burst alert System
additionally identifies on-board bright impulsive events (e.g., Gamma-ray
Bursts, GRBs) and broadcasts the corresponding position and trigger time to the
ground using a dedicated system of ~15 VHF receivers. All WFM data are planned
to be made public immediately. In this contribution we summarize the planned
organization of the LOFT ground segment (GS), as established in the mission
Yellow Book 1 . We describe the expected GS contributions from ESA and the LOFT
consortium. A review is provided of the planned LOFT data products and the
details of the data flow, archiving and distribution. Despite LOFT was not
selected for launch within the M3 call, its long assessment phase (> 2 years)
led to a very solid mission design and an efficient planning of its ground
operations.
[5]
oai:arXiv.org:1304.1349 [pdf] - 647970
INTEGRAL IBIS/ISGRI energy calibration in OSA 10
Caballero, I.;
Heras, J. A. Zurita;
Mattana, F.;
Soldi, S.;
Laurent, P.;
Lebrun, F.;
Natalucci, L.;
Fiocchi, M.;
Ferrigno, C.;
Rohlfs, R.
Submitted: 2013-04-04
We present the new energy calibration of the ISGRI detector onboard INTEGRAL,
that has been implemented in the Offline Scientific Analysis (OSA) version 10.
With the previous OSA 9 version, a clear departure from stability of both W and
22Na background lines was observed after MJD 54307 (revolution ~583). To solve
this problem, the energy correction in OSA 10 uses: 1) a new description for
the gain depending on the time and the pulse rise time, 2) an improved
temperature correction per module, and 3) a varying shape of the low threshold,
corrected for the change in energy resolution. With OSA 10, both background
lines show a remarkably stable behavior with a relative energy variation below
1% around the nominal position (>6% in OSA 9), and the energy reconstruction at
low energies is more stable compared to previous OSA versions. We extracted
Crab light curves with ISGRI in different energy bands using all available data
since the beginning of the mission, and found a very good agreement with the
currently operational hard X-ray instruments Swift/BAT and Fermi/GBM.
[6]
oai:arXiv.org:1101.2040 [pdf] - 1453868
Planck Early Results. V. The Low Frequency Instrument data processing
Zacchei, A.;
Maino, D.;
Baccigalupi, C.;
Bersanelli, M.;
Bonaldi, A.;
Bonavera, L.;
Burigana, C.;
Butler, R. C.;
Cuttaia, F.;
de Zotti, G.;
Dick, J.;
Frailis, M.;
Galeotta, S.;
González-Nuevo, J.;
Górski, K. M.;
Gregorio, A.;
Keihänen, E.;
Keskitalo, R.;
Knoche, J.;
Kurki-Suonio, H.;
Lawrence, C. R.;
Leach, S.;
Leahy, J. P.;
López-Caniego, M.;
Mandolesi, N.;
Maris, M.;
Matthai, F.;
Meinhold, P. R.;
Mennella, A.;
Morgante, G.;
Morisset, N.;
Natoli, P.;
Pasian, F.;
Perrotta, F.;
Polenta, G.;
Poutanen, T.;
Reinecke, M.;
Ricciardi, S.;
Rohlfs, R.;
Sandri, M.;
Suur-Uski, A. -S.;
Tauber, J. A.;
Tavagnacco, D.;
Terenzi, L.;
Tomasi, M.;
Valiviita, J.;
Villa, F.;
Zonca, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Bartolo, N.;
Bedini, L.;
Bennett, K.;
Binko, P.;
Borrill, J.;
Bouchet, F. R.;
Bremer, M.;
Cabella, P.;
Cappellini, B.;
Chen, X.;
Colombo, L.;
Cruz, M.;
Curto, A.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
de Gasperis, G.;
de Rosa, A.;
de Troia, G.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Dörl, U.;
Efstathiou, G.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Franceschi, E.;
Gaier, T. C.;
Gasparo, F.;
Génova-Santos, R. T.;
Giardino, G.;
Gómez, F.;
Gruppuso, A.;
Hansen, F. K.;
Hell, R.;
Herranz, D.;
Hovest, W.;
Huynh, M.;
Jewell, J.;
Juvela, M.;
Kisner, T. S.;
Knox, L.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Leonardi, R.;
León-Tavares, J.;
Lilje, P. B.;
Lubin, P. M.;
Maggio, G.;
Marinucci, D.;
Martínez-González, E.;
Massardi, M.;
Matarrese, S.;
Meharga, M. T.;
Melchiorri, A.;
Migliaccio, M.;
Mitra, S.;
Moss, A.;
Nørgaard-Nielsen, H. U.;
Pagano, L.;
Paladini, R.;
Paoletti, D.;
Partridge, B.;
Pearson, D.;
Pettorino, V.;
Pietrobon, D.;
Prézeau, G.;
Procopio, P.;
Puget, J. -L.;
Quercellini, C.;
Rachen, J. P.;
Rebolo, R.;
Robbers, G.;
Rocha, G.;
Rubiño-Martín, J. A.;
Salerno, E.;
Savelainen, M.;
Scott, D.;
Seiffert, M. D.;
Silk, J. I.;
Smoot, G. F.;
Sternberg, J.;
Stivoli, F.;
Stompor, R.;
Tofani, G.;
Toffolatti, L.;
Tuovinen, J.;
Türler, M.;
Umana, G.;
Vielva, P.;
Vittorio, N.;
Vuerli, C.;
Wade, L. A.;
Watson, R.;
White, S. D. M.;
Wilkinson, A.
Submitted: 2011-01-11, last modified: 2011-12-07
We describe the processing of data from the Low Frequency Instrument (LFI)
used in production of the Planck Early Release Compact Source Catalogue
(ERCSC). In particular, we discuss the steps involved in reducing the data from
telemetry packets to cleaned, calibrated, time-ordered data (TOD) and frequency
maps. Data are continuously calibrated using the modulation of the temperature
of the cosmic microwave background radiation induced by the motion of the
spacecraft. Noise properties are estimated from TOD from which the sky signal
has been removed using a generalized least square map-making algorithm.
Measured 1/f noise knee-frequencies range from 100mHz at 30GHz to a few tens of
mHz at 70GHz. A destriping code (Madam) is employed to combine radiometric data
and pointing information into sky maps, minimizing the variance of correlated
noise. Noise covariance matrices required to compute statistical uncertainties
on LFI and Planck products are also produced. Main beams are estimated down to
the approx -10dB level using Jupiter transits, which are also used for
geometrical calibration of the focal plane.
[7]
oai:arXiv.org:1001.4642 [pdf] - 33158
Off-line radiometric analysis of Planck/LFI data
Tomasi, M.;
Mennella, A.;
Galeotta, S.;
Lowe, S. R.;
Mendes, L.;
Leonardi, R.;
Villa, F.;
Cappellini, B.;
Gregorio, A.;
Meinhold, P.;
Sandri, M.;
Cuttaia, F.;
Terenzi, L.;
Maris, M.;
Valenziano, L.;
Salmon, M. J.;
Bersanelli, M.;
Binko, P.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Frailis, M.;
Franceschi, E.;
Gasparo, F.;
Maggio, G.;
Maino, D.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meharga, M.;
Morgante, G.;
Morisset, N.;
Pasian, F.;
Perrotta, F.;
Rohlfs, R.;
Turler, M.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) is an array of 22
pseudo-correlation radiometers on-board the Planck satellite to measure
temperature and polarization anisotropies in the Cosmic Microwave Background
(CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the
performances of the LFI, a software suite named LIFE has been developed. Its
aims are to provide a common platform to use for analyzing the results of the
tests performed on the single components of the instrument (RCAs, Radiometric
Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA).
Moreover, its analysis tools are designed to be used during the flight as well
to produce periodic reports on the status of the instrument. The LIFE suite has
been developed using a multi-layered, cross-platform approach. It implements a
number of analysis modules written in RSI IDL, each accessing the data through
a portable and heavily optimized library of functions written in C and C++. One
of the most important features of LIFE is its ability to run the same data
analysis codes both using ground test data and real flight data as input. The
LIFE software suite has been successfully used during the RCA/RAA tests and the
Planck Integrated System Tests. Moreover, the software has also passed the
verification for its in-flight use during the System Operations Verification
Tests, held in October 2008.
[8]
oai:arXiv.org:1001.4730 [pdf] - 33178
Level 1 on-ground telemetry handling in Planck LFI
Zacchei, A.;
Frailis, M.;
Maris, M.;
Morisset, N.;
Rohlfs, R.;
Meharga, M.;
Binko, P.;
Turler, M.;
Galeotta, S.;
Gasparo, F.;
Franceschi, E.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Fogliani, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Maino, D.;
Maggio, G.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meinhold, P.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Pasian, F.;
Perrotta, F.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave
Background (CMB) by covering the frequency range 30-70 GHz in three bands. The
primary instrument data source are the temperature samples acquired by the 22
radiometers mounted on the Planck focal plane. Such samples represent the
scientific data of LFI. In addition, the LFI instrument generates the so called
housekeeping data by sampling regularly the on-board sensors and registers. The
housekeeping data provides information on the overall health status of the
instrument and on the scientific data quality. The scientific and housekeeping
data are collected on-board into telemetry packets compliant with the ESA
Packet Telemetry standards. They represent the primary input to the first
processing level of the LFI Data Processing Centre. In this work we show the
software systems which build the LFI Level 1. A real-time assessment system,
based on the ESA SCOS 2000 generic mission control system, has the main purpose
of monitoring the housekeeping parameters of LFI and detect possible anomalies.
A telemetry handler system processes the housekeeping and scientific telemetry
of LFI, generating timelines for each acquisition chain and each housekeeping
parameter. Such timelines represent the main input to the subsequent processing
levels of the LFI DPC. A telemetry quick-look system allows the real-time
visualization of the LFI scientific and housekeeping data, by also calculating
quick statistical functions and fast Fourier transforms. The LFI Level 1 has
been designed to support all the mission phases, from the instrument ground
tests and calibration to the flight operations, and developed according to the
ESA engineering standards.
[9]
oai:arXiv.org:1001.4787 [pdf] - 33194
LFI Radiometric Chain Assembly (RCA) data handling "Rachel"
Malaspina, M.;
Franceschi, E.;
Battaglia, P.;
Binko, P.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Frailis, M.;
Franceschet, C.;
Galeotta, S.;
Gasparo, F.;
Gregorio, A.;
Lapolla, M.;
Leonardi, R.;
Maggio, G.;
Mandolesi, N.;
Manzato, P.;
Maris, M.;
Meharga, M.;
Meinhold, P.;
Morisset, N.;
Pasian, F.;
Perrotta, F.;
Rohlfs, R.;
Sandri, M.;
Tomasi, M.;
Turler, M.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
This paper is part of the Prelaunch status LFI papers published on JINST
(http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221).
Planck's Low Frequency Instrument is an array of 22 pseudo-correlation
radiometers at 30, 44, and 70 GHz. Before integrating the overall array
assembly, a first set of tests has been performed for each radiometer chain
assembly (RCA), consisting of two radiometers. In this paper, we describe
Rachel, a software application which has been purposely developed and used
during the RCA test campaign to carry out both near-realtime on-line data
analysis and data storage (in FITS format) of the raw output from the
radiometric chains.
[10]
oai:arXiv.org:1001.4838 [pdf] - 33213
A systematic approach to the Planck LFI end-to-end test and its
application to the DPC Level 1 pipeline
Frailis, M.;
Maris, M.;
Zacchei, A.;
Morisset, N.;
Rohlfs, R.;
Meharga, M.;
Binko, P.;
Turler, M.;
Galeotta, S.;
Gasparo, F.;
Franceschi, E.;
Butler, R. C.;
D'Arcangelo, O.;
Fogliani, S.;
Gregorio, A.;
Lowe, S. R.;
Maggio, G.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Pasian, F.;
Perrotta, F.;
Sandri, M.;
Terenzi, L.;
Tomasi, M.;
Zonca, A.
Submitted: 2010-01-26
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the
handling of the scientific and housekeeping telemetry. It is a critical
component of the Planck ground segment which has to strictly commit to the
project schedule to be ready for the launch and flight operations. In order to
guarantee the quality necessary to achieve the objectives of the Planck
mission, the design and development of the Level 1 software has followed the
ESA Software Engineering Standards. A fundamental step in the software life
cycle is the Verification and Validation of the software. The purpose of this
work is to show an example of procedures, test development and analysis
successfully applied to a key software project of an ESA mission. We present
the end-to-end validation tests performed on the Level 1 of the LFI-DPC, by
detailing the methods used and the results obtained. Different approaches have
been used to test the scientific and housekeeping data processing. Scientific
data processing has been tested by injecting signals with known properties
directly into the acquisition electronics, in order to generate a test dataset
of real telemetry data and reproduce as much as possible nominal conditions.
For the HK telemetry processing, validation software have been developed to
inject known parameter values into a set of real housekeeping packets and
perform a comparison with the corresponding timelines generated by the Level 1.
With the proposed validation and verification procedure, where the on-board and
ground processing are viewed as a single pipeline, we demonstrated that the
scientific and housekeeping processing of the Planck-LFI raw data is correct
and meets the project requirements.
[11]
oai:arXiv.org:1001.4737 [pdf] - 1937606
Optimization of Planck/LFI on--board data handling
Maris, M.;
Tomasi, M.;
Galeotta, S.;
Miccolis, M.;
Hildebrandt, S.;
Frailis, M.;
Rohlfs, R.;
Morisset, N.;
Zacchei, A.;
Bersanelli, M.;
Binko, P.;
Burigana, C.;
Butler, R. C.;
Cuttaia, F.;
Chulani, H.;
D'Arcangelo, O.;
Fogliani, S.;
Franceschi, E.;
Gasparo, F.;
Gomez, F.;
Gregorio, A.;
Herreros, J. M.;
Leonardi, R.;
Leutenegger, P.;
Maggio, G.;
Maino, D.;
Malaspina, M.;
Mandolesi, N.;
Manzato, P.;
Meharga, M.;
Meinhold, P.;
Mennella, A.;
Pasian, F.;
Perrotta, F.;
Rebolo, R.;
Turler, M.;
Zonca, A.
Submitted: 2010-01-26
To asses stability against 1/f noise, the Low Frequency Instrument (LFI)
onboard the Planck mission will acquire data at a rate much higher than the
data rate allowed by its telemetry bandwith of 35.5 kbps. The data are
processed by an onboard pipeline, followed onground by a reversing step. This
paper illustrates the LFI scientific onboard processing to fit the allowed
datarate. This is a lossy process tuned by using a set of 5 parameters Naver,
r1, r2, q, O for each of the 44 LFI detectors. The paper quantifies the level
of distortion introduced by the onboard processing, EpsilonQ, as a function of
these parameters. It describes the method of optimizing the onboard processing
chain. The tuning procedure is based on a optimization algorithm applied to
unprocessed and uncompressed raw data provided either by simulations, prelaunch
tests or data taken from LFI operating in diagnostic mode. All the needed
optimization steps are performed by an automated tool, OCA2, which ends with
optimized parameters and produces a set of statistical indicators, among them
the compression rate Cr and EpsilonQ. For Planck/LFI the requirements are Cr =
2.4 and EpsilonQ <= 10% of the rms of the instrumental white noise. To speedup
the process an analytical model is developed that is able to extract most of
the relevant information on EpsilonQ and Cr as a function of the signal
statistics and the processing parameters. This model will be of interest for
the instrument data analysis. The method was applied during ground tests when
the instrument was operating in conditions representative of flight. Optimized
parameters were obtained and the performance has been verified, the required
data rate of 35.5 Kbps has been achieved while keeping EpsilonQ at a level of
3.8% of white noise rms well within the requirements.
[12]
oai:arXiv.org:1001.2657 [pdf] - 1024642
Planck pre-launch status: the Planck-LFI programme
Mandolesi, N.;
Bersanelli, M.;
Butler, R. C.;
Artal, E.;
Baccigalupi, C.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartelmann, M.;
Bennett, K.;
Bhandari, P.;
Bonaldi, A.;
Borrill, J.;
Bremer, M.;
Burigana, C.;
Bowman, R. C.;
Cabella, P.;
Cantalupo, C.;
Cappellini, B.;
Courvoisier, T.;
Crone, G.;
Cuttaia, F.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
de Gasperis, G.;
De Rosa, A.;
De Troia, G.;
de Zotti, G.;
Dick, J.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Dörl, U.;
Dupac, X.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Frailis, M.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gasparo, F.;
Giardino, G.;
Gomez, F.;
Gonzalez-Nuevo, J.;
Górski, K. M.;
Gregorio, A.;
Gruppuso, A.;
Hansen, F.;
Hell, R.;
Herranz, D.;
Herreros, J. M.;
Hildebrandt, S.;
Hovest, W.;
Hoyland, R.;
Huffenberger, K.;
Janssen, M.;
Jaffe, T.;
Keihänen, E.;
Keskitalo, R.;
Kisner, T.;
Kurki-Suonio, H.;
Lähteenmäki, A.;
Lawrence, C. R.;
Leach, S. M.;
Leahy, J. P.;
Leonardi, R.;
Levin, S.;
Lilje, P. B.;
López-Caniego, M.;
Lowe, S. R.;
Lubin, P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Meinhold, P.;
Melchiorri, A.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Morigi, G.;
Morisset, N.;
Moss, A.;
Nash, A.;
Natoli, P.;
Nesti, R.;
Paine, C.;
Partridge, B.;
Pasian, F.;
Passvogel, T.;
Pearson, D.;
Pérez-Cuevas, L.;
Perrotta, F.;
Polenta, G.;
Popa, L. A.;
Poutanen, T.;
Prezeau, G.;
Prina, M.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Riller, T.;
Rocha, G.;
Roddis, N.;
Rohlfs, R.;
Rubiño-Martin, J. A.;
Salerno, E.;
Sandri, M.;
Scott, D.;
Seiffert, M.;
Silk, J.;
Simonetto, A.;
Smoot, G. F.;
Sozzi, C.;
Sternberg, J.;
Stivoli, F.;
Stringhetti, L.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Türler, M.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L.;
White, M.;
White, S.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-15
This paper provides an overview of the Low Frequency Instrument (LFI)
programme within the ESA Planck mission. The LFI instrument has been developed
to produce high precision maps of the microwave sky at frequencies in the range
27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation
spectrum. The scientific goals are described, ranging from fundamental
cosmology to Galactic and extragalactic astrophysics. The instrument design and
development are outlined, together with the model philosophy and testing
strategy. The instrument is presented in the context of the Planck mission. The
LFI approach to ground and inflight calibration is described. We also describe
the LFI ground segment. We present the results of a number of tests
demonstrating the capability of the LFI data processing centre (DPC) to
properly reduce and analyse LFI flight data, from telemetry information to
calibrated and cleaned time ordered data, sky maps at each frequency (in
temperature and polarization), component emission maps (CMB and diffuse
foregrounds), catalogs for various classes of sources (the Early Release
Compact Source Catalogue and the Final Compact Source Catalogue). The
organization of the LFI consortium is briefly presented as well as the role of
the core team in data analysis and scientific exploitation. All tests carried
out on the LFI flight model demonstrate the excellent performance of the
instrument and its various subunits. The data analysis pipeline has been tested
and its main steps verified. In the first three months after launch, the
commissioning, calibration, performance, and verification phases will be
completed, after which Planck will begin its operational life, in which LFI
will have an integral part.