Normalized to: Rogers, H.
[1]
oai:arXiv.org:2005.14067 [pdf] - 2103535
Constraints on low-mass, relic dark matter candidates from a
surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS Collaboration;
Amaral, D. W.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Banik, S.;
Barker, D.;
Bathurst, C.;
Bauer, D. A.;
Bezerra, L. V. S.;
Bhattacharyya, R.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Chen, R.;
Chott, N.;
Cooley, J.;
Coombes, H.;
Corbett, J.;
Cushman, P.;
De Brienne, F.;
di Vacri, M. L.;
Diamond, M. D.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fouts, K.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hines, B. A.;
Hollister, M. I.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Li, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
MacFarlane, D. B.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mayer, A. J.;
Michaud, É. M.;
Michielin, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nagorny, S.;
Nelson, J.;
Neog, H.;
Novati, V.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Pakarha, P.;
Partridge, R.;
Podviianiuk, R.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Rau, W.;
Reid, E.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sattari, A.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Sincavage, D. J.;
Stanford, C.;
Stein, M.;
Street, J.;
Toback, D.;
Underwood, R.;
Verma, S.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wills, L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Yu, T. C.;
Zhang, E.;
Zhang, H. G.;
Zhao, X.;
Zheng, L.
Submitted: 2020-05-28
This article presents an analysis and the resulting limits on light dark
matter inelastically scattering off of electrons, and on dark photon and
axion-like particle absorption, using a second-generation SuperCDMS
high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV
phonon energy resolution; for a detector bias of 100 V, this corresponds to a
charge resolution of 3% of a single electron-hole pair. The energy spectrum is
reported from a blind analysis with 1.2 gram-days of exposure acquired in an
above-ground laboratory. With charge carrier trapping and impact ionization
effects incorporated into the dark matter signal models, the dark
matter-electron cross section $\bar{\sigma}_{e}$ is constrained for dark matter
masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50
eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the
axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90%
confidence-level upper limits within the above mentioned mass ranges are
$\bar{\sigma}_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$,
$\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
[2]
oai:arXiv.org:1806.07043 [pdf] - 1944785
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in
Germanium with CDMSlite
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwal, S. R.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Banik, S.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-06-19, last modified: 2019-08-16
Future direct searches for low-mass dark matter particles with germanium
detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds
from radioactive isotopes activated by cosmogenic radiation inside the
germanium. There are limited experimental data available to constrain
production rates and a large spread of theoretical predictions. We examine the
calculation of expected production rates, and analyze data from the second run
of the CDMS low ionization threshold experiment (CDMSlite) to estimate the
rates for several isotopes. We model the measured CDMSlite spectrum and fit for
contributions from tritium and other isotopes. Using the knowledge of the
detector history, these results are converted to cosmogenic production rates at
sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H,
1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
[3]
oai:arXiv.org:1804.10697 [pdf] - 1877835
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive
Detector
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Banik, S.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Di Stefano, P. C. F.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Leyva, J. V.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E. H.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Romani, R. K.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
So, J.;
Speller, D.;
Stanford, C.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-04-27, last modified: 2019-05-03
We present the first limits on inelastic electron-scattering dark matter and
dark photon absorption using a prototype SuperCDMS detector having a charge
resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device).
These electron-recoil limits significantly improve experimental constraints on
dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We
demonstrate a sensitivity to dark photons competitive with other leading
approaches but using substantially less exposure (0.49 gram days). These
results demonstrate the scientific potential of phonon-mediated semiconductor
detectors that are sensitive to single electronic excitations.
[4]
oai:arXiv.org:1808.09098 [pdf] - 1873743
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood
Fit
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Banik, S.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
De Brienne, F.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Neog, H.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stanford, C.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-08-27, last modified: 2019-04-25
The Cryogenic Dark Matter Search low ionization threshold experiment
(CDMSlite) searches for interactions between dark matter particles and
germanium nuclei in cryogenic detectors. The experiment has achieved a low
energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark
matter particles. We present an analysis of the final CDMSlite data set, taken
with a different detector than was used for the two previous CDMSlite data
sets. This analysis includes a data "salting" method to protect against bias,
improved noise discrimination, background modeling, and the use of profile
likelihood methods to search for a dark matter signal in the presence of
backgrounds. We achieve an energy threshold of 70 eV and significantly improve
the sensitivity for dark matter particles with masses between 2.5 and 10
GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark
matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$
cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous
CDMSlite result.
[5]
oai:arXiv.org:1805.09942 [pdf] - 1867949
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS
Germanium Detectors
Agnese, Robert;
Aralis, Taylor;
Aramaki, Tsuguo;
Arnquist, Isaac;
Azadbakht, Elham;
Baker, William;
Banik, Samir;
Barker, D'Ann;
Bauer, Dan;
Binder, Thomas;
Bowles, Michael;
Brink, Paul;
Bunker, Ray;
Cabrera, Blas;
Calkins, Robert;
Cartaro, Concetta;
Cerdeno, David;
Chang, Yen-Yung;
Cooley, Jodi;
Cornell, Brett;
Cushman, Priscilla;
Di Stefano, Philippe;
Doughty, Todd;
Fascione, Eleanor;
Figueroa, Tali;
Fink, Caleb;
Fritts, Matt;
Gerbier, Gilles;
Germond, Richard;
Ghaith, Muad;
Golwala, Sunil;
Harris, Rusty;
Hong, Ziqing;
Hoppe, Eric;
Hsu, Lauren;
Huber, Martin;
Iyer, Vijay;
Jardin, Dan;
Jena, Chitrasen;
Kelsey, Michael;
Kennedy, Allison;
Kubik, Andrew;
Kurinsky, Noah;
Lawrence, Richard;
Loer, Ben;
Lopez-Asamar, Elias;
Lukens, Pat;
MacDonell, Danika;
Mahapatra, Rupak;
Mandic, Vuk;
Mast, Nicholas;
Miller, Eric;
Mirabolfathi, Nader;
Mohanty, Bedangadas;
Morales, Jorge;
Nelson, Jack;
Orrell, John;
Oser, Scott;
Page, William;
Partridge, Richard;
Pepin, Mark;
Ponce, Francisco;
Poudel, Sudip;
Pyle, Matt;
Qiu, Hang;
Rau, Wolfgang;
Reisetter, Angela;
Ren, Tom;
Reynolds, Tyler;
Roberts, Amy;
Robinson, Alan;
Rogers, Hannah;
Saab, Tarek;
Sadoulet, Bernard;
Sander, Joel;
Scarff, Andrew;
Schnee, Richard;
Scorza, Silvia;
Senapati, Kartik;
Serfass, Bruno;
Speller, Danielle;
Stein, Matthew;
Street, Joseph;
Tanaka, Hirohisa;
Toback, David;
Underwood, Ryan;
Villano, Anthony;
von Krosigk, Belina;
Watkins, Samuel;
Wilson, Jon;
Wilson, Matthew;
Winchell, Joshua;
Wright, Dennis;
Yellin, Steve;
Young, Betty;
Zhang, Xiaohe;
Zhao, Xuji
Submitted: 2018-05-24, last modified: 2019-04-16
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan
Underground Laboratory studied energy loss associated with Frenkel defect
formation in germanium crystals at mK temperatures using in situ $^{210}$Pb
sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its
expected 103 keV endpoint energy and determine an energy loss of
$\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this
result and using TRIM simulations, we extract the first experimentally
determined average displacement threshold energy of
$\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for
the analysis thresholds of future germanium-based dark matter searches.
[6]
oai:arXiv.org:1803.02903 [pdf] - 1724039
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Baker, W.;
Balakishiyeva, D.;
Banik, S.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Binder, T.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chagani, H.;
Chang, Y. -Y.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Doughty, T.;
Dragowsky, E. M.;
Esteban, L.;
Fallows, S.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Holmgren, D.;
Hong, Z.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
McCarthy, K. A.;
Miller, E. H.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mohanty, B.;
Moore, D.;
Mendoza, J. D. Morales;
Nelson, J.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Martinez, M. Penalver;
Pepin, M.;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Roberts, A.;
Rogers, H. E.;
Robinson, A. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Di Stefano, P. C. F.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wilson, M. J.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-03-07, last modified: 2018-07-27
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark
matter particles that elastically scatter from nuclei in semiconductor
detectors. The resulting nuclear-recoil energy depositions are detected by
ionization and phonon sensors. Neutrons produce a similar spectrum of
low-energy nuclear recoils in such detectors, while most other backgrounds
produce electron recoils. The absolute energy scale for nuclear recoils is
necessary to interpret results correctly. The energy scale can be determined in
CDMS II silicon detectors using neutrons incident from a broad-spectrum
$^{252}$Cf source, taking advantage of a prominent resonance in the neutron
elastic scattering cross section of silicon at a recoil (neutron) energy near
20 (182) keV. Results indicate that the phonon collection efficiency for
nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the
same energy. Comparisons of the ionization signals for nuclear recoils to those
measured previously by other groups at higher electric fields indicate that the
ionization collection efficiency for CDMS II silicon detectors operated at
$\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and
gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of
these measurements on previously published CDMS II silicon results is small.
[7]
oai:arXiv.org:1707.01632 [pdf] - 1622232
Low-Mass Dark Matter Search with CDMSlite
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Baker, W.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chang, Y.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E. H.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Martinez, M. Penalver;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wilson, M. J;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2017-07-06, last modified: 2018-01-18
The SuperCDMS experiment is designed to directly detect weakly interacting
massive particles (WIMPs) that may constitute the dark matter in our Galaxy.
During its operation at the Soudan Underground Laboratory, germanium detectors
were run in the CDMSlite mode to gather data sets with sensitivity specifically
for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias
voltage is applied to amplify the phonon signals produced by drifting charges.
This paper presents studies of the experimental noise and its effect on the
achievable energy threshold, which is demonstrated to be as low as 56
eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing
configuration is described in detail, with analysis corrections for voltage
variations to the level of a few percent. Detailed studies of the
electric-field geometry, and the resulting successful development of a fiducial
parameter, eliminate poorly measured events, yielding an energy resolution
ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at
${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical
uncertainties relevant to the WIMP-search limits, specifically examining how
they are affected by variations in the most probable WIMP velocity and the
Galactic escape velocity. These variations become more important for WIMP
masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass
WIMP-nucleon interactions are derived, with new parameter space excluded for
WIMP masses $\lesssim$3 GeV/$c^2$
[8]
oai:arXiv.org:1612.09038 [pdf] - 1567636
Multi-Dimensional Effective Field Theory Analysis for Direct Detection
of Dark Matter
Submitted: 2016-12-29, last modified: 2017-04-18
The scattering of dark matter particles off nuclei in direct detection
experiments can be described in terms of a multidimensional effective field
theory (EFT). A new systematic analysis technique is developed using the EFT
approach and Bayesian inference methods to exploit, when possible, the
energy-dependent information of the detected events, experimental efficiencies,
and backgrounds. Highly dimensional likelihoods are calculated over the mass of
the weakly interacting massive particle (WIMP) and multiple EFT coupling
coefficients, which can then be used to set limits on these parameters and
choose models (EFT operators) that best fit the direct detection data.
Expanding the parameter space beyond the standard spin-independent isoscalar
cross section and WIMP mass reduces tensions between previously published
experiments. Combining these experiments to form a single joint likelihood
leads to stronger limits than when each experiment is considered on its own.
Simulations using two nonstandard operators (3 and 8) are used to test the
proposed analysis technique in up to five dimensions and demonstrate the
importance of using multiple likelihood projections when determining
constraints on WIMP mass and EFT coupling coefficients. In particular, this
shows that an explicit momentum dependence in dark matter scattering can be
identified.
[9]
oai:arXiv.org:1610.00006 [pdf] - 1561019
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Arnquist, I.;
Baker, W.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeño, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hong, Z.;
Hoppe, E.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Orrell, J. L.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2016-09-30
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly
detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter
by using cryogenic detectors of two types (HV and iZIP) and two target
materials (germanium and silicon). The experiment is being designed with an
initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$
for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue
exploration to both smaller masses and better sensitivities. The phonon
sensitivity of the HV detectors will be sufficient to detect nuclear recoils
from sub-GeV dark matter. A detailed calibration of the detector response to
low energy recoils will be needed to optimize running conditions of the HV
detectors and to interpret their data for dark matter searches. Low-activity
shielding, and the depth of SNOLAB, will reduce most backgrounds, but
cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be
present in the detectors at some level. Even if these backgrounds are x10
higher than expected, the science reach of the HV detectors would be over three
orders of magnitude beyond current results for a dark matter mass of 1
GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in
detector response and backgrounds, and will provide better sensitivity for dark
matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and
iZIP), and targets (germanium and silicon), planned for the experiment, as well
as flexibility in how the detectors are operated, will allow us to maximize the
low-mass reach, and understand the backgrounds that the experiment will
encounter. Upgrades to the experiment, perhaps with a variety of
ultra-low-background cryogenic detectors, will extend dark matter sensitivity
down to the "neutrino floor", where coherent scatters of solar neutrinos become
a limiting background.
[10]
oai:arXiv.org:1503.03379 [pdf] - 1458536
Dark matter effective field theory scattering in direct detection
experiments
Schneck, K.;
Cabrera, B.;
Cerdeno, D. G.;
Mandic, V.;
Rogers, H. E.;
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Caldwell, D. O.;
Calkins, R.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D. M.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Roberts, A.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yang, X.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-03-11, last modified: 2016-08-16
We examine the consequences of the effective field theory (EFT) of dark
matter-nucleon scattering for current and proposed direct detection
experiments. Exclusion limits on EFT coupling constants computed using the
optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX,
and the necessity of combining results from multiple experiments in order to
determine dark matter parameters is discussed. We demonstrate that spectral
differences between the standard dark matter model and a general EFT
interaction can produce a bias when calculating exclusion limits and when
developing signal models for likelihood and machine learning techniques. We
also discuss the implications of the EFT for the next-generation (G2) direct
detection experiments and point out regions of complementarity in the EFT
parameter space.
[11]
oai:arXiv.org:1509.02448 [pdf] - 1371572
WIMP-Search Results from the Second CDMSlite Run
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Asai, M.;
Baker, W.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Roberts, A.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Underwood, R.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-09-08, last modified: 2016-03-09
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic
germanium detectors operated at a relatively high bias voltage to amplify the
phonon signal in the search for weakly interacting massive particles (WIMPs).
Results are presented from the second CDMSlite run with an exposure of 70 kg
days, which reached an energy threshold for electron recoils as low as 56 eV. A
fiducialization cut reduces backgrounds below those previously reported by
CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross
section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
[12]
oai:arXiv.org:1504.05871 [pdf] - 1293576
Improved WIMP-search reach of the CDMS II germanium data
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cerdeño, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yang, X.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-04-22, last modified: 2015-10-13
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were
reprocessed with an improved charge-pulse fitting algorithm. Two new analysis
techniques to reject surface-event backgrounds were applied to the 612 kg days
germanium-detector WIMP-search exposure. An extended analysis was also
completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to
increase sensitivity near a WIMP mass of 8 GeV/$c^2$. After unblinding, there
were zero candidate events above a deposited energy of 10 keV and 6 events in
the lower-threshold analysis. This yielded minimum WIMP-nucleon
spin-independent scattering cross-section limits of $1.8 \times 10^{-44}$ and
$1.18 \times 10 ^{-41}$ cm$^2$ at 90\% confidence for 60 and 8.6 GeV/$c^2$
WIMPs, respectively. This improves the previous CDMS II result by a factor of
2.4 (2.7) for 60 (8.6) GeV/$c^2$ WIMPs.
[13]
oai:arXiv.org:1504.02900 [pdf] - 1300165
The Dark Energy Camera
Flaugher, B.;
Diehl, H. T.;
Honscheid, K.;
Abbott, T. M. C.;
Alvarez, O.;
Angstadt, R.;
Annis, J. T.;
Antonik, M.;
Ballester, O.;
Beaufore, L.;
Bernstein, G. M.;
Bernstein, R. A.;
Bigelow, B.;
Bonati, M.;
Boprie, D.;
Brooks, D.;
Buckley-Geer, E. J.;
Campa, J.;
Cardiel-Sas, L.;
Castander, F. J.;
Castilla, J.;
Cease, H.;
Cela-Ruiz, J. M.;
Chappa, S.;
Chi, E.;
Cooper, C.;
da Costa, L. N.;
Dede, E.;
Derylo, G.;
DePoy, D. L.;
de Vicente, J.;
Doel, P.;
Drlica-Wagner, A.;
Eiting, J.;
Elliott, A. E.;
Emes, J.;
Estrada, J.;
Neto, A. Fausti;
Finley, D. A.;
Flores, R.;
Frieman, J.;
Gerdes, D.;
Gladders, M. D.;
Gregory, B.;
Gutierrez, G. R.;
Hao, J.;
Holland, S. E.;
Holm, S.;
Huffman, D.;
Jackson, C.;
James, D. J.;
Jonas, M.;
Karcher, A.;
Karliner, I.;
Kent, S.;
Kessler, R.;
Kozlovsky, M.;
Kron, R. G.;
Kubik, D.;
Kuehn, K.;
Kuhlmann, S.;
Kuk, K.;
Lahav, O.;
Lathrop, A.;
Lee, J.;
Levi, M. E.;
Lewis, P.;
Li, T. S.;
Mandrichenko, I.;
Marshall, J. L.;
Martinez, G.;
Merritt, K. W.;
Miquel, R.;
Munoz, F.;
Neilsen, E. H.;
Nichol, R. C.;
Nord, B.;
Ogando, R.;
Olsen, J.;
Palio, N.;
Patton, K.;
Peoples, J.;
Plazas, A. A.;
Rauch, J.;
Reil, K.;
Rheault, J. -P.;
Roe, N. A.;
Rogers, H.;
Roodman, A.;
Sanchez, E.;
Scarpine, V.;
Schindler, R. H.;
Schmidt, R.;
Schmitt, R.;
Schubnell, M.;
Schultz, K.;
Schurter, P.;
Scott, L.;
Serrano, S.;
Shaw, T. M.;
Smith, R. C.;
Soares-Santos, M.;
Stefanik, A.;
Stuermer, W.;
Suchyta, E.;
Sypniewski, A.;
Tarle, G.;
Thaler, J.;
Tighe, R.;
Tran, C.;
Tucker, D.;
Walker, A. R.;
Wang, G.;
Watson, M.;
Weaverdyck, C.;
Wester, W.;
Woods, R.;
Yanny, B.
Submitted: 2015-04-11
The Dark Energy Camera is a new imager with a 2.2-degree diameter field of
view mounted at the prime focus of the Victor M. Blanco 4-meter telescope on
Cerro Tololo near La Serena, Chile. The camera was designed and constructed by
the Dark Energy Survey Collaboration, and meets or exceeds the stringent
requirements designed for the wide-field and supernova surveys for which the
collaboration uses it. The camera consists of a five element optical corrector,
seven filters, a shutter with a 60 cm aperture, and a CCD focal plane of 250
micron thick fully-depleted CCDs cooled inside a vacuum Dewar. The 570 Mpixel
focal plane comprises 62 2kx4k CCDs for imaging and 12 2kx2k CCDs for guiding
and focus. The CCDs have 15 microns x15 microns pixels with a plate scale of
0.263 arc sec per pixel. A hexapod system provides state-of-the-art focus and
alignment capability. The camera is read out in 20 seconds with 6-9 electrons
readout noise. This paper provides a technical description of the camera's
engineering, construction, installation, and current status.
[14]
oai:arXiv.org:1409.3270 [pdf] - 969775
First direct limits on Lightly Ionizing Particles with electric charge
less than $e/6$
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nelson, H.;
Nelson, R. H.;
Ogburn, R. W.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-09-10, last modified: 2015-02-03
While the Standard Model of particle physics does not include free particles
with fractional charge, experimental searches have not ruled out their
existence. We report results from the Cryogenic Dark Matter Search (CDMS II)
experiment that give the first direct-detection limits for
cosmogenically-produced relativistic particles with electric charge lower than
$e$/6. A search for tracks in the six stacked detectors of each of two of the
CDMS II towers found no candidates, thereby excluding new parameter space for
particles with electric charges between $e$/6 and $e$/200.
[15]
oai:arXiv.org:1410.1003 [pdf] - 975596
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Graham, M.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nelson, R. H.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-10-03
We report on the results of a search for a Weakly Interacting Massive
Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search
(CDMS~II) experiment using a maximum likelihood analysis. A background model is
constructed using GEANT4 to simulate the surface-event background from
$^{210}$Pb decay-chain events, while using independent calibration data to
model the gamma background. Fitting this background model to the data results
in no statistically significant WIMP component. In addition, we perform fits
using an analytic ad hoc background model proposed by Collar and Fields, who
claimed to find a large excess of signal-like events in our data. We confirm
the strong preference for a signal hypothesis in their analysis under these
assumptions, but excesses are observed in both single- and multiple-scatter
events, which implies the signal is not caused by WIMPs, but rather reflects
the inadequacy of their background model.
[16]
oai:arXiv.org:1405.5115 [pdf] - 1209640
Feedback from Winds and Supernovae in Massive Stellar Clusters - II.
X-Ray Emission
Submitted: 2014-05-20
The X-ray emission from a simulated massive stellar cluster is investigated.
The emission is calculated from a 3D hydrodynamical model which incorporates
the mechanical feedback from the stellar winds of 3 O-stars embedded in a giant
molecular cloud clump containing 3240 M$_{\odot}$ of molecular material within
a 4 pc radius. A simple prescription for the evolution of the stars is used,
with the first supernova explosion at t=4.4 Myrs. We find that the presence of
the GMC clump causes short-lived attenuation effects on the X-ray emission of
the cluster. However, once most of the material has been ablated away by the
winds the remaining dense clumps do not have a noticable effect on the
attenuation compared with the assumed interstellar medium column. We determine
the evolution of the cluster X-ray luminosity, L$_X$, and spectra, and generate
synthetic images. The intrinsic X-ray luminosity drops from nearly 10$^{34}$
ergs s$^{-1}$ while the winds are `bottled up', to a near constant value of
1.7$\times 10^{32}\rm ergs s^{-1}$ between t=1-4 Myrs. L$_X$ reduces slightly
during each star's red supergiant stage due to the depressurization of the hot
gas. However, L$_X$ increases to $\approx 10^{34}\rm\,ergs s^{-1}$ during each
star's Wolf-Rayet stage. The X-ray luminosity is enhanced by 2-3 orders of
magnitude to $\sim 10^{37}\rm ergs s^{-1}$ for at least 4600 yrs after each
supernova, at which time the blast wave leaves the grid and the X-ray
luminosity drops. The X-ray luminosity of our simulation is generally
considerably fainter than predicted from spherically-symmetric bubble models,
due to the leakage of hot gas material through gaps in the outer shell. This
process reduces the pressure within our simulation and thus the X-ray emission.
However, the X-ray luminosities and temperatures which we obtain are comparable
to similarly powerful massive young clusters.
[17]
oai:arXiv.org:1302.2443 [pdf] - 1164521
Feedback from Winds and Supernovae in Massive Stellar Clusters. I:
Hydrodynamics
Submitted: 2013-02-11
We use 3D hydrodynamical models to investigate the effects of massive star
feedback from winds and supernovae on inhomogeneous molecular material left
over from the formation of a massive stellar cluster. We simulate the
interaction of the mechanical energy input from a cluster with 3 O-stars into a
giant molecular cloud (GMC) clump containing 3240 solar masses of molecular
material within a 4 pc radius. The cluster wind blows out of the molecular
clump along low-density channels, into which denser clump material is
entrained. We find that the densest molecular regions are surprisingly
resistant to ablation by the cluster wind, in part due to shielding by other
dense regions closer to the cluster. Nonetheless, molecular material is
gradually removed by the cluster wind during which mass-loading factors in
excess of several 100 are obtained. Because the clump is very porous, 60-75 per
cent of the injected wind energy escapes the simulation domain, with the
difference being radiated. After 4.4 Myr, the massive stars in our simulation
begin to explode as supernovae. The highly structured environment into which
the SN energy is released allows even weaker coupling to the remaining dense
material and practically all of the SN energy reaches the wider environment.
The molecular material is almost completely dispersed and destroyed after 6
Myr. The escape fraction of ionizing radiation is estimated to be about 50 per
cent during the first 4 Myr of the cluster's life. A similar model with a
larger and more massive GMC clump reveals the same general picture, though more
time is needed for it to be destroyed.
[18]
oai:arXiv.org:1209.5276 [pdf] - 566737
Feedback from Winds and Supernovae in Massive Stellar Clusters
Submitted: 2012-09-24
We simulate the effects of massive star feedback, via winds and SNe, on
inhomogeneous molecular material left over from the formation of a massive
stellar cluster. We use 3D hydrodynamic models with a temperature dependent
average particle mass to model the separate molecular, atomic, and ionized
phases. We find that the winds blow out of the molecular clump along
low-density channels, and gradually ablate denser material into these. However,
the dense molecular gas is surprisingly long-lived and is not immediately
affected by the first star in the cluster exploding.
[19]
oai:arXiv.org:1111.1625 [pdf] - 1091447
The RMS Survey: Resolving kinematic distance ambiguities towards a
sample of compact HII regions using HI absorption
Submitted: 2011-11-07
We present high-resolution HI data obtained using the Australia Telescope
Compact Array to resolve the near/far distance ambiguities towards a sample of
compact HII regions from the Red MSX Source (RMS) survey. The high resolution
data are complemented with lower resolution archival HI data extracted from the
Southern and VLA Galactic Plane surveys. We resolve the distance ambiguity for
nearly all of the 105 sources where the continuum was strong enough to allow
analysis of the HI absorption line structure. This represents another step in
the determination of distances to the total RMS sample, which with over 1,000
massive young stellar objects and compact HII regions, is the largest and most
complete sample of its kind. The full sample will allow the distribution of
massive star formation in the Galaxy to be examined.