sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Rogers, F. J.

Normalized to: Rogers, F.

15 article(s) in total. 168 co-authors, from 1 to 9 common article(s). Median position in authors list is 12,0.

[1]  oai:arXiv.org:2002.04163  [pdf] - 2046557
Cosmic-ray Antinuclei as Messengers of New Physics: Status and Outlook for the New Decade
Comments: 42 pages, 14 figures
Submitted: 2020-02-10
The precise measurement of cosmic-ray antinuclei serves as an important means for identifying the nature of dark matter and other new astrophysical phenomena, and could be used with other cosmic-ray species to understand cosmic-ray production and propagation in the Galaxy. For instance, low-energy antideuterons would provide a "smoking gun" signature of dark matter annihilation or decay, essentially free of astrophysical background. Studies in recent years have emphasized that models for cosmic-ray antideuterons must be considered together with the abundant cosmic antiprotons and any potential observation of antihelium. Therefore, a second dedicated Antideuteron Workshop was organized at UCLA in March 2019, bringing together a community of theorists and experimentalists to review the status of current observations of cosmic-ray antinuclei, the theoretical work towards understanding these signatures, and the potential of upcoming measurements to illuminate ongoing controversies. This review aims to synthesize this recent work and present implications for the upcoming decade of antinuclei observations and searches. This includes discussion of a possible dark matter signature in the AMS-02 antiproton spectrum, the most recent limits from BESS Polar-II on the cosmic antideuteron flux, and reports of candidate antihelium events by AMS-02; recent collider and cosmic-ray measurements relevant for antinuclei production models; the state of cosmic-ray transport models in light of AMS-02 and Voyager data; and the prospects for upcoming experiments, such as GAPS. This provides a roadmap for progress on cosmic antinuclei signatures of dark matter in the coming years.
[2]  oai:arXiv.org:1912.06571  [pdf] - 2014538
Large-area Si(Li) Detectors for X-ray Spectrometry and Particle Tracking for the GAPS Experiment
Comments:
Submitted: 2019-12-13
Large-area lithium-drifted silicon (Si(Li)) detectors, operable 150{\deg}C above liquid nitrogen temperature, have been developed for the General Antiparticle Spectrometer (GAPS) balloon mission and will form the first such system to operate in space. These 10 cm-diameter, 2.5 mm-thick multi-strip detectors have been verified in the lab to provide <4 keV FWHM energy resolution for X-rays as well as tracking capability for charged particles, while operating in conditions (~-40{\deg}C and ~1 Pa) achievable on a long-duration balloon mission with a large detector payload. These characteristics enable the GAPS silicon tracker system to identify cosmic antinuclei via a novel technique based on exotic atom formation, de-excitation, and annihilation. Production and large-scale calibration of ~1000 detectors has begun for the first GAPS flight, scheduled for late 2021. The detectors developed for GAPS may also have other applications, for example in heavy nuclei identification.
[3]  oai:arXiv.org:1906.00054  [pdf] - 1995412
Large-area Si(Li) detectors for X-ray spectrometry and particle tracking in the GAPS experiment
Comments: Accepted for publication at JINST, 16 pages, 8 figures
Submitted: 2019-05-31, last modified: 2019-11-08
The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique geometric, performance, and cost requirements of the General Antiparticle Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The GAPS Si(Li) detectors will form the first large-area, relatively high-temperature Si(Li) detector system with sensitivity to X-rays to operate at high altitude. These 10 cm-diameter, 2.5 mm-thick, 4- or 8-strip detectors provide the active area, X-ray absorption efficiency, energy resolution, and particle tracking capability necessary for the GAPS exotic-atom particle identification technique. In this paper, the detector performance is validated on the bases of X-ray energy resolution and reconstruction of cosmic minimum ionizing particle (MIP) signals. We use the established noise model for semiconductor detectors to distinguish sources of noise due to the detector from those due to signal processing electronics. We demonstrate that detectors with either 4 strips or 8 strips can provide the required $\lesssim$4 keV (FWHM) X-ray energy resolution at flight temperatures of $-35$ to $-45^{\circ}$C, given the proper choice of signal processing electronics. Approximately 1000 8-strip detectors will be used for the first GAPS Antarctic balloon flight, scheduled for late 2021.
[4]  oai:arXiv.org:1906.05577  [pdf] - 1983873
Developing a mass-production model of large-area Si(Li) detectors with high operating temperatures
Comments: 28 pages, 11 figures, submitted in 6/13/2019; re-submitted in 8/23/2019;
Submitted: 2019-06-13, last modified: 2019-08-27
This study presents a fabrication process for lithium-drifted silicon (Si(Li)) detectors that, compared to previous methods, allows for mass production at a higher yield, while providing a large sensitive area and low leakage currents at relatively high temperatures. This design, developed for the unique requirements of the General Antiparticle Spectrometer (GAPS) experiment, has an overall diameter of 10 cm, with ~9 cm of active area segmented into 8 readout strips, and an overall thickness of 2.5 mm, with $\gtrsim$2.2 mm ($\gtrsim$90%) sensitive thickness. An energy resolution $\lesssim$4 keV full-width at half-maximum (FWHM) for 20-100 keV X-rays is required at the operating temperature ~-40C, which is far above the liquid nitrogen temperatures conventionally used to achieve fine energy resolution. High-yield production is also required for GAPS, which consists of $\gtrsim$1000 detectors. Our specially-developed Si crystal and custom methods of Li evaporation, diffusion and drifting allow for a thick, large-area and uniform sensitive layer. We find that retaining a thin undrifted layer on the p-side of the detector drastically reduces the leakage current, which is a dominant component of the energy resolution at these temperatures. A guard-ring structure and optimal etching of the detector surface are also confirmed to suppress the leakage current. We report on the mass production of these detectors that is ongoing now, and demonstrate it is capable of delivering a high yield of ~90%.
[5]  oai:arXiv.org:1908.03154  [pdf] - 1931578
GAPS: Searching for Dark Matter using Antinuclei in Cosmic Rays
Comments: 8 pages, 7 figures, Proc. 36th International Cosmic Ray Conference (ICRC 2019), Madison, USA
Submitted: 2019-08-08
The General Antiparticle Spectrometer (GAPS) will carry out a sensitive dark matter search by measuring low-energy ($\mathrm{E} < 0.25 \mathrm{GeV/nucleon}$) cosmic ray antinuclei. The primary targets are low-energy antideuterons produced in the annihilation or decay of dark matter. At these energies antideuterons from secondary/tertiary interactions are expected to have very low fluxes, significantly below those predicted by well-motivated, beyond the standard model theories. GAPS will also conduct low-energy antiproton and antihelium searches. Combined, these observations will provide a powerful search for dark matter and provide the best observations to date on primordial black hole evaporation on Galactic length scales. The GAPS instrument detects antinuclei using the novel exotic atom technique. It consists of a central tracker with a surrounding time-of-flight (TOF) system. The tracker is a one cubic meter volume containing 10 cm-diameter lithium-drifted silicon (Si(Li)) detectors. The TOF is a plastic scintillator system that will both trigger the Si(Li) tracker and enable better reconstruction of particle tracks. After coming to rest in the tracker, antinuclei will form an excited exotic atom. This will then de-excite via characteristic X-ray transitions before producing a pion/proton star when the antiparticle annihilates with the nucleus. This unique event topology will give GAPS the nearly background-free detection capability required for a rare-event search. Here we present the scientific motivation for the GAPS experiment, its design and its current status as it prepares for flight in the austral summer of 2021-22.
[6]  oai:arXiv.org:1812.07255  [pdf] - 1800114
Development of Large-area Lithium-drifted Silicon Detectors for the GAPS Experiment
Comments: submitted to IEEE NSS/MIC 2018 Proceedings
Submitted: 2018-12-18
We have developed large-area lithium-drifted silicon (Si(Li)) detectors to meet the unique requirements of the General Antiparticle Spectrometer (GAPS) experiment. GAPS is an Antarctic balloon-borne mission scheduled for the first flight in late 2020. The GAPS experiment aims to survey low-energy cosmic-ray antinuclei, particularly antideuterons, which are recognized as essentially background-free signals from dark matter annihilation or decay. The GAPS Si(Li) detector design is a thickness of 2.5 mm, diameter of 10 cm and 8 readout strips. The energy resolution of <4 keV (FWHM) for 20 to 100 keV X-rays at temperature of -35 to -45 C, far above the liquid nitrogen temperatures frequently used to achieve fine energy resolution, is required. We developed a high-quality Si crystal and Li-evaporation, diffusion and drift methods to form a uniform Li-drifted layer. Guard ring structure and optimal etching of the surface are confirmed to suppress the leakage current, which is a main source of noise. We found a thin un-drifted layer retained on the p-side effectively suppresses the leakage current. By these developments, we succeeded in developing the GAPS Si(Li) detector. As the ultimate GAPS instrument will require >1000 10-cm diameter Si(Li) detectors to achieve high sensitivity to rare antideuteron events, high-yield production is also a key factor for the success of the GAPS mission.
[7]  oai:arXiv.org:1809.09714  [pdf] - 1757324
GAPS: A New Cosmic Ray Anti-matter Experiment
Comments: Talk presented CIPANP2018. 13 pages, LaTeX, 7 figures. Higher resolution figs at http://gaps1.astro.ucla.edu/gaps/papers2018/cipanp18
Submitted: 2018-09-25
The General AntiParticle Spectrometer (GAPS) is a balloon-borne instrument designed to detect cosmic-ray antimatter using the novel exotic atom technique, obviating the strong magnetic fields required by experiments like AMS, PAMELA, or BESS. It will be sensitive to primary antideuterons with kinetic energies of $\approx0.05-0.2$ GeV/nucleon, providing some overlap with the previously mentioned experiments at the highest energies. For $3\times35$ day balloon flights, and standard classes of primary antideuteron propagation models, GAPS will be sensitive to $m_{\mathrm{DM}}\approx10-100$ GeV c$^{-2}$ WIMPs with a dark-matter flux to astrophysical flux ratio approaching 100. This clean primary channel is a key feature of GAPS and is crucial for a rare event search. Additionally, the antiproton spectrum will be extended with high statistics measurements to cover the $0.07 \leq E \leq 0.25 $ GeV domain. For $E>0.2$ GeV GAPS data will be complementary to existing experiments, while $E<0.2$ GeV explores a new regime. The first flight is scheduled for late 2020 in Antarctica. These proceedings will describe the astrophysical processes and backgrounds relevant to the dark matter search, a brief discussion of detector operation, and construction progress made to date.
[8]  oai:arXiv.org:1807.07912  [pdf] - 1719637
Fabrication of low-cost, large-area prototype Si(Li) detectors for the GAPS experiment
Comments: Accepted for publication at Nuclear Instrumentation and Methods A, 12 pages, 11 figures
Submitted: 2018-07-20
A Si(Li) detector fabrication procedure has been developed with the aim of satisfying the unique requirements of the GAPS (General Antiparticle Spectrometer) experiment. Si(Li) detectors are particularly well-suited to the GAPS detection scheme, in which several planes of detectors act as the target to slow and capture an incoming antiparticle into an exotic atom, as well as the spectrometer and tracker to measure the resulting decay X-rays and annihilation products. These detectors must provide the absorption depth, energy resolution, tracking efficiency, and active area necessary for this technique, all within the significant temperature, power, and cost constraints of an Antarctic long-duration balloon flight. We report here on the fabrication and performance of prototype 2"-diameter, 1-1.25 mm-thick, single-strip Si(Li) detectors that provide the necessary X-ray energy resolution of $\sim$4 keV for a cost per unit area that is far below that of previously-acquired commercial detectors. This fabrication procedure is currently being optimized for the 4"-diameter, 2.5 mm-thick, multi-strip geometry that will be used for the GAPS flight detectors.
[9]  oai:arXiv.org:1710.05299  [pdf] - 1648653
Initial Performance of the COSINE-100 Experiment
Comments: 19 pages, 25 figures, EPJC accepted
Submitted: 2017-10-15, last modified: 2018-02-11
COSINE is a dark matter search experiment based on an array of low background NaI(Tl) crystals located at the Yangyang underground laboratory. The assembly of COSINE-100 was completed in the summer of 2016 and the detector is currently collecting physics quality data aimed at reproducing the DAMA/LIBRA experiment that reported an annual modulation signal. Stable operation has been achieved and will continue for at least two years. Here, we describe the design of COSINE-100, including the shielding arrangement, the configuration of the NaI(Tl) crystal detection elements, the veto systems, and the associated operational systems, and we show the current performance of the experiment.
[10]  oai:arXiv.org:1712.02011  [pdf] - 1648729
Muon detector for the COSINE-100 experiment
Comments: 11 pages, 19 figures
Submitted: 2017-12-05
The COSINE-100 dark matter search experiment has started taking physics data with the goal of performing an independent measurement of the annual modulation signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic scintillator panels in the outermost layer of the shield surrounding the COSINE-100 detector. It is used to detect cosmic ray muons in order to understand the impact of the muon annual modulation on dark matter analysis. Assembly and initial performance test of each module have been performed at a ground laboratory. The installation of the detector in Yangyang Underground Laboratory (Y2L) was completed in the summer of 2016. Using three months of data, the muon underground flux was measured to be 328 $\pm$ 1(stat.)$\pm$ 10(syst.) muons/m$^2$/day. In this report, the assembly of the muon detector and the results from the analysis are presented.
[11]  oai:arXiv.org:1710.00452  [pdf] - 1589126
The GAPS Experiment to Search for Dark Matter using Low-energy Antimatter
Comments: 8 pags, 3 figures, Proc. 35th International Cosmic Ray Conference (ICRC 2017), Busan, Korea
Submitted: 2017-10-01
The GAPS experiment is designed to carry out a sensitive dark matter search by measuring low-energy cosmic ray antideuterons and antiprotons. GAPS will provide a new avenue to access a wide range of dark matter models and masses that is complementary to direct detection techniques, collider experiments and other indirect detection techniques. Well-motivated theories beyond the Standard Model contain viable dark matter candidates which could lead to a detectable signal of antideuterons resulting from the annihilation or decay of dark matter particles. The dark matter contribution to the antideuteron flux is believed to be especially large at low energies (E < 1 GeV), where the predicted flux from conventional astrophysical sources (i.e. from secondary interactions of cosmic rays) is very low. The GAPS low-energy antiproton search will provide stringent constraints on less than 10 GeV dark matter, will provide the best limits on primordial black hole evaporation on Galactic length scales, and will explore new discovery space in cosmic ray physics. Unlike other antimatter search experiments such as BESS and AMS that use magnetic spectrometers, GAPS detects antideuterons and antiprotons using an exotic atom technique. This technique, and its unique event topology, will give GAPS a nearly background-free detection capability that is critical in a rare-event search. GAPS is designed to carry out its science program using long-duration balloon flights in Antarctica. A prototype instrument was successfully flown from Taiki, Japan in 2012. GAPS has now been approved by NASA to proceed towards the full science instrument, with the possibility of a first long-duration balloon flight in late 2020. Here we motivate low-energy cosmic ray antimatter searches and discuss the current status of the GAPS experiment and the design of the payload.
[12]  oai:arXiv.org:1602.05939  [pdf] - 1538892
First search for a dark matter annual modulation signal with NaI(Tl) in the Southern Hemisphere by DM-Ice17
Comments: 6 pages, 5 figures, revised version as published in PRD
Submitted: 2016-02-18, last modified: 2017-02-28
We present the first search for a dark matter annual modulation signal in the Southern Hemisphere conducted with NaI(Tl) detectors, performed by the DM-Ice17 experiment. Nuclear recoils from dark matter interactions are expected to yield an annually modulated signal independent of location within the Earth's hemispheres. DM-Ice17, the first step in the DM-Ice experimental program, consists of 17 kg of NaI(Tl) located at the South Pole under 2200 m.w.e. overburden of Antarctic glacial ice. Taken over 3.6 years for a total exposure of 60.8 kg yr, DM-Ice17 data are consistent with no modulation in the energy range of 4-20 keV, providing the strongest limits on weakly interacting massive particle dark matter from a direct detection experiment located in the Southern Hemisphere. The successful deployment and stable long-term operation of DM-Ice17 establishes the South Pole ice as a viable location for future dark matter searches and in particular for a high-sensitivity NaI(Tl) dark matter experiment to directly test the DAMA/LIBRA claim of the observation of dark matter.
[13]  oai:arXiv.org:0909.3990  [pdf] - 28647
Addendum to "Equation of state of classical Coulomb plasma mixtures"
Comments: 4 pages, 4 figures, accepted for publication in Phys. Rev. E
Submitted: 2009-09-22
Recently developed analytic approximation for the equation of state of fully ionized nonideal electron-ion plasma mixtures [Potekhin et al., Phys. Rev. E, 79, 016411 (2009); arXiv:0812.4344], which covers the transition between the weak and strong Coulomb coupling regimes and reproduces numerical results obtained in the hypernetted chain (HNC) approximation, is modified in order to fit the small deviations from the linear mixing in the strong coupling regime, revealed by recent Monte Carlo simulations. In addition, a mixing rule is proposed for the regime of weak coupling, which generalizes post-Debye density corrections to the case of mixtures and numerically agrees with the HNC approximation in that regime.
[14]  oai:arXiv.org:0812.4344  [pdf] - 19796
Equation of state of classical Coulomb plasma mixtures
Comments: 6 pages, 7 figures; Phys. Rev. E. In v.2 after proofreading, minor typos are fixed
Submitted: 2008-12-23, last modified: 2009-01-07
We develop analytic approximations of thermodynamic functions of fully ionized nonideal electron-ion plasma mixtures. In the regime of strong Coulomb coupling, we use our previously developed analytic approximations for the free energy of one-component plasmas with rigid and polarizable electron background and apply the linear mixing rule (LMR). Other thermodynamic functions are obtained through analytic derivation of this free energy. In order to obtain an analytic approximation for the intermediate coupling and transition to the Debye-Hueckel limit, we perform hypernetted-chain calculations of the free energy, internal energy, and pressure for mixtures of different ion species and introduce a correction to the LMR, which allows a smooth transition from strong to weak Coulomb coupling in agreement with the numerical results.
[15]  oai:arXiv.org:astro-ph/9510116  [pdf] - 93489
X-ray spectra from convective photospheres of neutron stars
Comments: 2 pages, from Wuerzburg X-ray Conference (Sep. 25-29, 1995); final version; ask for psfile to: zavlin@rosat.mpe-garching.mpg.de
Submitted: 1995-10-23, last modified: 1995-11-09
We present first results of modeling convective photospheres of neutron stars. We show that in photospheres composed of the light elements convection arises only at relatively low effective temperatures (< 3-5*10^4 K), whereas in the case of iron compositon it arises at < 3*10^ K. Convection changes the depth dependence of the photosphere temperature and the shapes of the emergent spectra. Thus, it should be taken into account for the proper interpretation of EUV/soft-X-ray observations of the thermal radiation from neutron stars.