sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Roesch, M.

Normalized to: Roesch, M.

5 article(s) in total. 29 co-authors, from 1 to 5 common article(s). Median position in authors list is 7,0.

[1]  oai:arXiv.org:1212.4585  [pdf] - 1934839
Development of Lumped Element Kinetic Inductance Detectors for NIKA
Comments: 5 pages, 12 figures; ISSTT 2011 Workshop
Submitted: 2012-12-19
Lumped-element kinetic inductance detectors(LEKIDs) have recently shown considerable promise as direct absorption mm-wavelength detectors for astronomical applications. One major research thrust within the N\'eel Iram Kids Array (NIKA) collaboration has been to investigate the suitability of these detectors for deployment at the 30-meter IRAM telescope located on Pico Veleta in Spain. Compared to microwave kinetic inductance detectors (MKID), using quarter wavelength resonators, the resonant circuit of a LEKID consists of a discrete inductance and capacitance coupled to a feedline. A high and constant current density distribution in the inductive part of these resonators makes them very sensitive. Due to only one metal layer on a silicon substrate, the fabrication is relatively easy. In order to optimize the LEKIDs for this application, we have recently probed a wide variety of individual resonator and array parameters through simulation and physical testing. This included determining the optimal feed-line coupling, pixel geometry, resonator distribution within an array (in order to minimize pixel cross-talk), and resonator frequency spacing. Based on these results, a 144-pixel Aluminum array was fabricated and tested in a dilution fridge with optical access, yielding an average optical NEP of ~2E-16 W/Hz^1/2 (best pixels showed NEP = 6E-17 W/Hz^1/2 under 4-8 pW loading per pixel). In October 2010 the second prototype of LEKIDs has been tested at the IRAM 30 m telescope. A new LEKID geometry for 2 polarizations will be presented. Also first optical measurements of a titanium nitride array will be discussed.
[2]  oai:arXiv.org:1201.5486  [pdf] - 469493
Kinetic inductance detectors for millimeter and submillimeter astronomy / D\'etecteurs \`a inductance cin\'etique pour l'astronomie millim\'etrique et sub-millim\'etrique
Comments: Withdrawn, will be resubmitted with a new list of authors
Submitted: 2012-01-26, last modified: 2012-01-27
We present recent developments in Kinetic Inductance Detectors (KID) for large arrays of detectors. The main application is ground-based millimeter wave astronomy. We focus in particular, as a case study, on our own experiment: NIKA (N\'eel IRAM KID Arrays). NIKA is today the best in-the-field experiment using KID-based instruments, and consists of a dual-band imaging system designed for the IRAM 30 meter telescope at Pico Veleta. We describe in this article, after a general context introduction, the KID working principle and the readout electronics, crucial to take advantage of the intrinsic KID multiplexability. We conclude with a small subset of the astronomical sources observed simultaneously at 2 mm and 1.4 mm by NIKA during the last run, held in October 2010. Nous d\'ecrivons les r\'ecents d\'eveloppements concernant les grandes matrices de d\'etecteurs \`a inductance cin\'etique (KID) dont l'application principale est l'astronomie millim\'etrique au sol. Nous d\'etaillons en particulier notre propre cam\'era : NIKA (N\'eel IRAM KID Arrays) qui est aujourd'hui l'instrument le plus abouti mettant en oeuvre des KIDs. NIKA est une cam\'era bi-bande con\c{c}ue pour le radiot\'elescope de 30 m\`etres de l'IRAM \`a Pico Veleta. Apr\'es avoir d\'ecrit le contexte instrumental dans lequel ils s'inscrivent, nous expliquerons le principe de fonctionnement des KIDs et de leur \'electronique de lecture, cruciale pour pouvoir tirer parti de leur potentiel de muliplexage. Pour finir, nous pr\'esentons quelques exemples d'observations effectu\'ees par NIKA dans les bandes de 2 mm et 1,4 mm au cours de la derni\`ere campagne d'observation en octobre 2010.
[3]  oai:arXiv.org:1102.1314  [pdf] - 958372
Electronics and data acquisition demonstrator for a kinetic inductance camera
Comments:
Submitted: 2011-02-07, last modified: 2011-06-01
A prototype of digital frequency multiplexing electronics allowing the real time monitoring of kinetic inductance detector (KIDs) arrays for mm-wave astronomy has been developed. It requires only 2 coaxial cables for instrumenting a large array. For that, an excitation comb of frequencies is generated and fed through the detector. The direct frequency synthesis and the data acquisition relies heavily on a large FPGA using parallelized and pipelined processing. The prototype can instrument 128 resonators (pixels) over a bandwidth of 125 MHz. This paper describes the technical solution chosen, the algorithm used and the results obtained.
[4]  oai:arXiv.org:1102.0870  [pdf] - 958350
A dual-band millimeter-wave kinetic inductance camera for the IRAM 30-meter telescope
Comments: Submitted to ApJ (abstract reduced to fit ApJ standards)
Submitted: 2011-02-04, last modified: 2011-02-08
Context. The Neel IRAM KIDs Array (NIKA) is a fully-integrated measurement system based on kinetic inductance detectors (KIDs) currently being developed for millimeter wave astronomy. In a first technical run, NIKA was successfully tested in 2009 at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain. This prototype consisted of a 27-42 pixel camera imaging at 150 GHz. Subsequently, an improved system has been developed and tested in October 2010 at the Pico Veleta telescope. The instrument upgrades included dual-band optics allowing simultaneous imaging at 150 GHz and 220 GHz, faster sampling electronics enabling synchronous measurement of up to 112 pixels per measurement band, improved single-pixel sensitivity, and the fabrication of a sky simulator to replicate conditions present at the telescope. Results. The new dual-band NIKA was successfully tested in October 2010, performing in-line with sky simulator predictions. Initially the sources targeted during the 2009 run were re-imaged, verifying the improved system performance. An optical NEP was then calculated to be around 2 \dot 10-16 W/Hz1/2. This improvement in comparison with the 2009 run verifies that NIKA is approaching the target sensitivity for photon-noise limited ground-based detectors. Taking advantage of the larger arrays and increased sensitivity, a number of scientifically-relevant faint and extended objects were then imaged including the Galactic Center SgrB2(FIR1), the radio galaxy Cygnus A and the NGC1068 Seyfert galaxy. These targets were all observed simultaneously in the 150 GHz and 220 GHz atmospheric windows.
[5]  oai:arXiv.org:1004.2209  [pdf] - 301556
NIKA: A millimeter-wave kinetic inductance camera
Comments: Accepted for publication in Astronomy & Astrophysics
Submitted: 2010-04-13, last modified: 2010-06-20
Current generation millimeter wavelength detectors suffer from scaling limits imposed by complex cryogenic readout electronics. To circumvent this it is imperative to investigate technologies that intrinsically incorporate strong multiplexing. One possible solution is the kinetic inductance detector (KID). In order to assess the potential of this nascent technology, a prototype instrument optimized for the 2 mm atmospheric window was constructed. Known as the N\'eel IRAM KIDs Array (NIKA), it was recently tested at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain. The measurement resulted in the imaging of a number of sources, including planets, quasars, and galaxies. The images for Mars, radio star MWC349, quasar 3C345, and galaxy M87 are presented. From these results, the optical NEP was calculated to be around $1 \times 10^{-15}$ W$ / $Hz$^{1/2}$. A factor of 10 improvement is expected to be readily feasible by improvements in the detector materials and reduction of performance-degrading spurious radiation.