Normalized to: Roesch, M.
[1]
oai:arXiv.org:1212.4585 [pdf] - 1934839
Development of Lumped Element Kinetic Inductance Detectors for NIKA
Roesch, M.;
Benoit, A.;
Bideaud, A.;
Boudou, N.;
Calvo, M.;
Cruciani, A.;
Doyle, S.;
Leduc, H. G.;
Monfardini, A.;
Swenson, L.;
Leclercq, S.;
Mauskopf, P.;
Schuster, K. F.
Submitted: 2012-12-19
Lumped-element kinetic inductance detectors(LEKIDs) have recently shown
considerable promise as direct absorption mm-wavelength detectors for
astronomical applications. One major research thrust within the N\'eel Iram
Kids Array (NIKA) collaboration has been to investigate the suitability of
these detectors for deployment at the 30-meter IRAM telescope located on Pico
Veleta in Spain. Compared to microwave kinetic inductance detectors (MKID),
using quarter wavelength resonators, the resonant circuit of a LEKID consists
of a discrete inductance and capacitance coupled to a feedline. A high and
constant current density distribution in the inductive part of these resonators
makes them very sensitive. Due to only one metal layer on a silicon substrate,
the fabrication is relatively easy. In order to optimize the LEKIDs for this
application, we have recently probed a wide variety of individual resonator and
array parameters through simulation and physical testing. This included
determining the optimal feed-line coupling, pixel geometry, resonator
distribution within an array (in order to minimize pixel cross-talk), and
resonator frequency spacing. Based on these results, a 144-pixel Aluminum array
was fabricated and tested in a dilution fridge with optical access, yielding an
average optical NEP of ~2E-16 W/Hz^1/2 (best pixels showed NEP = 6E-17 W/Hz^1/2
under 4-8 pW loading per pixel). In October 2010 the second prototype of LEKIDs
has been tested at the IRAM 30 m telescope. A new LEKID geometry for 2
polarizations will be presented. Also first optical measurements of a titanium
nitride array will be discussed.
[2]
oai:arXiv.org:1201.5486 [pdf] - 469493
Kinetic inductance detectors for millimeter and submillimeter astronomy
/ D\'etecteurs \`a inductance cin\'etique pour l'astronomie millim\'etrique
et sub-millim\'etrique
Submitted: 2012-01-26, last modified: 2012-01-27
We present recent developments in Kinetic Inductance Detectors (KID) for
large arrays of detectors. The main application is ground-based millimeter wave
astronomy. We focus in particular, as a case study, on our own experiment: NIKA
(N\'eel IRAM KID Arrays). NIKA is today the best in-the-field experiment using
KID-based instruments, and consists of a dual-band imaging system designed for
the IRAM 30 meter telescope at Pico Veleta. We describe in this article, after
a general context introduction, the KID working principle and the readout
electronics, crucial to take advantage of the intrinsic KID multiplexability.
We conclude with a small subset of the astronomical sources observed
simultaneously at 2 mm and 1.4 mm by NIKA during the last run, held in October
2010.
Nous d\'ecrivons les r\'ecents d\'eveloppements concernant les grandes
matrices de d\'etecteurs \`a inductance cin\'etique (KID) dont l'application
principale est l'astronomie millim\'etrique au sol. Nous d\'etaillons en
particulier notre propre cam\'era : NIKA (N\'eel IRAM KID Arrays) qui est
aujourd'hui l'instrument le plus abouti mettant en oeuvre des KIDs. NIKA est
une cam\'era bi-bande con\c{c}ue pour le radiot\'elescope de 30 m\`etres de
l'IRAM \`a Pico Veleta. Apr\'es avoir d\'ecrit le contexte instrumental dans
lequel ils s'inscrivent, nous expliquerons le principe de fonctionnement des
KIDs et de leur \'electronique de lecture, cruciale pour pouvoir tirer parti de
leur potentiel de muliplexage. Pour finir, nous pr\'esentons quelques exemples
d'observations effectu\'ees par NIKA dans les bandes de 2 mm et 1,4 mm au cours
de la derni\`ere campagne d'observation en octobre 2010.
[3]
oai:arXiv.org:1102.1314 [pdf] - 958372
Electronics and data acquisition demonstrator for a kinetic inductance
camera
Submitted: 2011-02-07, last modified: 2011-06-01
A prototype of digital frequency multiplexing electronics allowing the real
time monitoring of kinetic inductance detector (KIDs) arrays for mm-wave
astronomy has been developed. It requires only 2 coaxial cables for
instrumenting a large array. For that, an excitation comb of frequencies is
generated and fed through the detector. The direct frequency synthesis and the
data acquisition relies heavily on a large FPGA using parallelized and
pipelined processing. The prototype can instrument 128 resonators (pixels) over
a bandwidth of 125 MHz. This paper describes the technical solution chosen, the
algorithm used and the results obtained.
[4]
oai:arXiv.org:1102.0870 [pdf] - 958350
A dual-band millimeter-wave kinetic inductance camera for the IRAM
30-meter telescope
Monfardini, A.;
Benoit, A.;
Bideaud, A.;
Swenson, L. J.;
Roesch, M.;
Desert, F. X.;
Doyle, S.;
Endo, A.;
Cruciani, A.;
Ade, P.;
Baryshev, A. M.;
Baselmans, J. J. A.;
Bourrion, O.;
Calvo, M.;
Camus, P.;
Ferrari, L.;
Giordano, C.;
Hoffmann, C.;
Leclercq, S.;
Macias-Perez, J. F.;
Mauskopf, P.;
Schuster, K. F.;
Tucker, C.;
Vescovi, C.;
Yates, S. J. C.
Submitted: 2011-02-04, last modified: 2011-02-08
Context. The Neel IRAM KIDs Array (NIKA) is a fully-integrated measurement
system based on kinetic inductance detectors (KIDs) currently being developed
for millimeter wave astronomy. In a first technical run, NIKA was successfully
tested in 2009 at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter
telescope at Pico Veleta, Spain. This prototype consisted of a 27-42 pixel
camera imaging at 150 GHz. Subsequently, an improved system has been developed
and tested in October 2010 at the Pico Veleta telescope. The instrument
upgrades included dual-band optics allowing simultaneous imaging at 150 GHz and
220 GHz, faster sampling electronics enabling synchronous measurement of up to
112 pixels per measurement band, improved single-pixel sensitivity, and the
fabrication of a sky simulator to replicate conditions present at the
telescope. Results. The new dual-band NIKA was successfully tested in October
2010, performing in-line with sky simulator predictions. Initially the sources
targeted during the 2009 run were re-imaged, verifying the improved system
performance. An optical NEP was then calculated to be around 2 \dot 10-16
W/Hz1/2. This improvement in comparison with the 2009 run verifies that NIKA is
approaching the target sensitivity for photon-noise limited ground-based
detectors. Taking advantage of the larger arrays and increased sensitivity, a
number of scientifically-relevant faint and extended objects were then imaged
including the Galactic Center SgrB2(FIR1), the radio galaxy Cygnus A and the
NGC1068 Seyfert galaxy. These targets were all observed simultaneously in the
150 GHz and 220 GHz atmospheric windows.
[5]
oai:arXiv.org:1004.2209 [pdf] - 301556
NIKA: A millimeter-wave kinetic inductance camera
Monfardini, A.;
Swenson, L. J.;
Bideaud, A.;
Désert, F. X.;
Yates, S. J. C.;
Benoit, A.;
Baryshev, A. M.;
Baselmans, J. J. A.;
Doyle, S.;
Klein, B.;
Roesch, M.;
Tucker, C.;
Ade, P.;
Calvo, M.;
Camus, P.;
Giordano, C.;
Guesten, R.;
Hoffmann, C.;
Leclercq, S.;
Mauskopf, P.;
Schuster, K. F.
Submitted: 2010-04-13, last modified: 2010-06-20
Current generation millimeter wavelength detectors suffer from scaling limits
imposed by complex cryogenic readout electronics. To circumvent this it is
imperative to investigate technologies that intrinsically incorporate strong
multiplexing. One possible solution is the kinetic inductance detector (KID).
In order to assess the potential of this nascent technology, a prototype
instrument optimized for the 2 mm atmospheric window was constructed. Known as
the N\'eel IRAM KIDs Array (NIKA), it was recently tested at the Institute for
Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain.
The measurement resulted in the imaging of a number of sources, including
planets, quasars, and galaxies. The images for Mars, radio star MWC349, quasar
3C345, and galaxy M87 are presented. From these results, the optical NEP was
calculated to be around $1 \times 10^{-15}$ W$ / $Hz$^{1/2}$. A factor of 10
improvement is expected to be readily feasible by improvements in the detector
materials and reduction of performance-degrading spurious radiation.