Normalized to: Rocci, P.
[1]
oai:arXiv.org:1906.04707 [pdf] - 1905883
Euclid preparation III. Galaxy cluster detection in the wide photometric
survey, performance and algorithm selection
Euclid Collaboration;
Adam, R.;
Vannier, M.;
Maurogordato, S.;
Biviano, A.;
Adami, C.;
Ascaso, B.;
Bellagamba, F.;
Benoist, C.;
Cappi, A.;
Díaz-Sánchez, A.;
Durret, F.;
Farrens, S.;
Gonzalez, A. H.;
Iovino, A.;
Licitra, R.;
Maturi, M.;
Mei, S.;
Merson, A.;
Munari, E.;
Pelló, R.;
Ricci, M.;
Rocci, P. F.;
Roncarelli, M.;
Sarron, F.;
Amoura, Y.;
Andreon, S.;
Apostolakos, N.;
Arnaud, M.;
Bardelli, S.;
Bartlett, J.;
Baugh, C. M.;
Borgani, S.;
Brodwin, M.;
Castander, F.;
Castignani, G.;
Cucciati, O.;
De Lucia, G.;
Dubath, P.;
Fosalba, P.;
Giocoli, C.;
Hoekstra, H.;
Mamon, G. A.;
Melin, J. B.;
Moscardini, L.;
Paltani, S.;
Radovich, M.;
Sartoris, B.;
Schultheis, M.;
Sereno, M.;
Weller, J.;
Burigana, C.;
Carvalho, C. S.;
Corcione, L.;
Kurki-Suonio, H.;
Lilje, P. B.;
Sirri, G.;
Toledo-Moreo, R.;
Zamorani, G.
Submitted: 2019-06-11, last modified: 2019-06-19
Galaxy cluster counts in bins of mass and redshift have been shown to be a
competitive probe to test cosmological models. This method requires an
efficient blind detection of clusters from surveys with a well-known selection
function and robust mass estimates. The Euclid wide survey will cover 15000
deg$^2$ of the sky in the optical and near-infrared bands, down to magnitude 24
in the $H$-band. The resulting data will make it possible to detect a large
number of galaxy clusters spanning a wide-range of masses up to redshift $\sim
2$. This paper presents the final results of the Euclid Cluster Finder
Challenge (CFC). The objective of these challenges was to select the cluster
detection algorithms that best meet the requirements of the Euclid mission. The
final CFC included six independent detection algorithms, based on different
techniques, such as photometric redshift tomography, optimal filtering,
hierarchical approach, wavelet and friend-of-friends algorithms. These
algorithms were blindly applied to a mock galaxy catalog with representative
Euclid-like properties. The relative performance of the algorithms was assessed
by matching the resulting detections to known clusters in the simulations.
Several matching procedures were tested, thus making it possible to estimate
the associated systematic effects on completeness to $<3$%. All the tested
algorithms are very competitive in terms of performance, with three of them
reaching $>80$% completeness for a mean purity of 80% down to masses of
$10^{14}$ M$_{\odot}$ and up to redshift $z=2$. Based on these results, two
algorithms were selected to be implemented in the Euclid pipeline, the AMICO
code, based on matched filtering, and the PZWav code, based on an adaptive
wavelet approach. [abridged]
[2]
oai:arXiv.org:1506.08212 [pdf] - 1269370
The DICE calibration project: design, characterization, and first
results
Regnault, N.;
Guyonnet, A.;
Schahmanèche, K.;
Guillou, L. Le;
Antilogus, P.;
Astier, P.;
Barrelet, E.;
Betoule, M.;
Bongard, S.;
Cuillandre, J. -C.;
Juramy, C.;
Pain, R.;
Rocci, P. -F.;
Tisserand, P.;
Villa, F.
Submitted: 2015-06-26
We describe the design, operation, and first results of a photometric
calibration project, called DICE (Direct Illumination Calibration Experiment),
aiming at achieving precise instrumental calibration of optical telescopes. The
heart of DICE is an illumination device composed of 24 narrow-spectrum,
high-intensity, light-emitting diodes (LED) chosen to cover the
ultraviolet-to-near-infrared spectral range. It implements a point-like source
placed at a finite distance from the telescope entrance pupil, yielding a flat
field illumination that covers the entire field of view of the imager. The
purpose of this system is to perform a lightweight routine monitoring of the
imager passbands with a precision better than 5 per-mil on the relative
passband normalisations and about 3{\AA} on the filter cutoff positions. The
light source is calibrated on a spectrophotometric bench. As our fundamental
metrology standard, we use a photodiode calibrated at NIST. The radiant
intensity of each beam is mapped, and spectra are measured for each LED. All
measurements are conducted at temperatures ranging from 0{\deg}C to 25{\deg}C
in order to study the temperature dependence of the system. The photometric and
spectroscopic measurements are combined into a model that predicts the spectral
intensity of the source as a function of temperature. We find that the
calibration beams are stable at the $10^{-4}$ level -- after taking the slight
temperature dependence of the LED emission properties into account. We show
that the spectral intensity of the source can be characterised with a precision
of 3{\AA} in wavelength. In flux, we reach an accuracy of about 0.2-0.5%
depending on how we understand the off-diagonal terms of the error budget
affecting the calibration of the NIST photodiode. With a routine 60-mn
calibration program, the apparatus is able to constrain the passbands at the
targeted precision levels.
[3]
oai:arXiv.org:1212.4864 [pdf] - 1158630
Improved Photometric Calibration of the SNLS and the SDSS Supernova
Surveys
Betoule, M.;
Marriner, J.;
Regnault, N.;
Cuillandre, J. -C.;
Astier, P.;
Guy, J.;
Balland, C.;
Hage, P. El;
Hardin, D.;
Kessler, R.;
Guillou, L. Le;
Mosher, J.;
Pain, R.;
Rocci, P. -F.;
Sako, M.;
Schahmaneche, K.
Submitted: 2012-12-19
We present a combined photometric calibration of the SNLS and the SDSS
supernova survey, which results from a joint effort of the SDSS and the SNLS
collaborations. We deliver fluxes calibrated to the HST spectrophotometric star
network for large sets of tertiary stars that cover the science fields of both
surveys in all photometric bands. We also cross-calibrate directly the two
surveys and demonstrate their consistency. For each survey the flat-fielding is
revised based on the analysis of dithered star observations. The calibration
transfer from the HST spectrophotometric standard stars to the multi-epoch
tertiary standard star catalogs in the science fields follows three different
paths: observations of primary standard stars with the SDSS PT telescope;
observations of Landolt secondary standard stars with SNLS MegaCam instrument
at CFHT; and direct observation of faint HST standard stars with MegaCam. In
addition, the tertiary stars for the two surveys are cross-calibrated using
dedicated MegaCam observations of stripe 82. This overlap enables the
comparison of these three calibration paths and justifies using their
combination to improve the calibration accuracy. Flat-field corrections have
improved the uniformity of each survey as demonstrated by the comparison of
photometry in overlapping fields: the rms of the difference between the two
surveys is 3 mmag in gri, 4 mmag in z and 8 mmag in u. We also find a
remarkable agreement (better than 1%) between the SDSS and the SNLS calibration
in griz. The cross-calibration and the introduction of direct calibration
observations bring redundancy and strengthen the confidence in the resulting
calibration. We conclude that the surveys are calibrated to the HST with a
precision of about 0.4% in griz. This precision is comparable to the external
uncertainty affecting the color of the HST primary standard stars.
[4]
oai:arXiv.org:1208.6301 [pdf] - 557215
(Sn)DICE: A Calibration System Designed for Wide Field Imagers
Submitted: 2012-08-30
Dark Energy studies with type Ia supernovae set very tight constraints on the
photometric calibration of the imagers used to detect the supernovae and follow
up their flux variations. Among the key challenges is the measurement of the
shape and normalization of the instrumental throughput. The DICE system was
developed by members of the Supernova Legacy Survey (SNLS), building upon the
lessons learnt working with the MegaCam imager. It consists in a very stable
light source, placed in the telescope enclosure, and generating compact,
conical beams, yielding an almost flat illumination of the imager focal plane.
The calibration light is generated by narrow spectrum LEDs selected to cover
the entire wavelength range of the imager. It is monitored in real time using
control photodiodes. A first DICE demonstrator, SnDICE has been installed at
CFHT. A second generation instrument (SkyDICE) has been installed in the
enclosure of the SkyMapper telescope. We present the main goals of the project.
We discuss the main difficulties encountered when trying to calibrate a wide
field imager, such as MegaCam (or SkyMapper) using such a calibrated light
source.