sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Robertson, Matthew

Normalized to: Robertson, M.

2 article(s) in total. 30 co-authors. Median position in authors list is 13,0.

[1]  oai:arXiv.org:1810.10187  [pdf] - 1812909
Properties of selected structural and flat flexible cabling materials for low temperature applications
Comments: Published in the journal Cryogenics
Submitted: 2018-10-24, last modified: 2019-01-10
We present measurements of the low temperature thermal conductivity for materials useful in the construction of cryogenic supports for scientific instrumentation and in the fabrication of flat flexible cryogenic cabling. The materials we measure have relatively low thermal conductivity. We present a method for measuring the heat transfer coefficient of flat cabling and show, using an example, that the thermal conductivity of a flex cable is reasonably well predicted by composing the thermal conductivities of its constituent material layers. Room temperature physical and mechanical data is given for the materials studied, as well as an overview of relevant materials science and manufacturing details. Materials include Timet Ti 15-3 and Ti 21S, Materion alloy vit105 (LM105) in amorphous state, ATI Metals Nb-47Ti, Johnson Matthey nitinol (NiTi), Mersen graphite grade 2020, DuPont Pyralux coverlay and Vespel SCP-5050, and Fralock Cirlex polyimide sheets. All data is in the temperature range 0.5 to 2 K, and up to 5 K for SCP-5050.
[2]  oai:arXiv.org:1807.01938  [pdf] - 1711133
Veloce Rosso: Australia's new precision radial velocity spectrograph
Comments: Submitted to SPIE 10702
Submitted: 2018-07-05
Veloce is an ultra-stable fibre-fed R4 echelle spectrograph for the 3.9 m Anglo-Australian Telescope. The first channel to be commissioned, Veloce 'Rosso', utilises multiple low-cost design innovations to obtain Doppler velocities for Sun-like and M-dwarf stars at <1 m/s precision. The spectrograph has an asymmetric white-pupil format with a 100-mm beam diameter, delivering R>75,000 spectra over a 580-950 nm range for the Rosso channel. Simultaneous calibration is provided by a single-mode pulsed laser frequency comb in tandem with a traditional arc lamp. A bundle of 19 object fibres provides a 2.4" field of view for full sampling of stellar targets from the AAT site. Veloce is housed in dual environmental enclosures that maintain positive air pressure at a stability of +/-0.3 mbar, with a thermal stability of +/-0.01 K on the optical bench. We present a technical overview and early performance data from Australia's next major spectroscopic machine.