Normalized to: Rigaut, O.
[1]
oai:arXiv.org:1801.03730 [pdf] - 1616675
QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to
look at the polarized Cosmic Microwave Background
Mennella, A.;
Ade, P. A. R.;
Aumont, J.;
Banfi, S.;
Battaglia, P.;
Battistelli, E. S.;
Baù, A.;
Bélier, B.;
Bennett, D.;
Bergé, L.;
Bernard, J. Ph.;
Bersanelli, M.;
Bigot-Sazy, M. A.;
Bleurvacq, N.;
Bordier, G.;
Brossard, J.;
Bunn, E. F.;
Burke, D. P.;
Buzi, D.;
Buzzelli, A.;
Cammilleri, D.;
Cavaliere, F.;
Chanial, P.;
Chapron, C.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
Couchot, F.;
D'Agostino, R.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Decourcelle, T.;
Del Torto, F.;
Dumoulin, L.;
Etchegoyen, A.;
Franceschet, C.;
Garcia, B.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Ghribi, A.;
Giard, M.;
Giraud-Héraud, Y.;
Gradziel, M.;
Grandsire, L.;
Hamilton, J. Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versillé, S.;
Holtzer, N.;
Incardona, F.;
Kaplan, J.;
Korotkov, A.;
Krachmalnicoff, N.;
Lamagna, L.;
Lande, J.;
Loucatos, S.;
Lowitz, A.;
Lukovic, V.;
Maffei, B.;
Marnieros, S.;
Martino, J.;
Masi, S.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Mele, L.;
Melhuish, S.;
Montier, L.;
Murphy, A.;
Néel, D.;
Ng, M. W.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pelosi, A.;
Perbost, C.;
Perdereau, O.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Préle, D.;
Puddu, R.;
Rambaud, D.;
Rigaut, O.;
Romero, G. E.;
Salatino, M.;
Schillaci, A.;
Scully, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Torchinsky, S.;
Tristram, M.;
Tucker, C.;
Tucker, G.;
Viganò, D.;
Vittorio, N.;
Voisin, F.;
Watson, B.;
Zannoni, M.;
Zullo, A.
Submitted: 2018-01-11
In this paper we describe QUBIC, an experiment that takes up the challenge
posed by the detection of primordial gravitational waves with a novel approach,
that combines the sensitivity of state-of-the art bolometric detectors with the
systematic effects control typical of interferometers. The so-called
"self-calibration" is a technique deeply rooted in the interferometric nature
of the instrument and allows us to clean the measured data from instrumental
effects. The first module of QUBIC is a dual band instrument (150 GHz and 220
GHz) that will be deployed in Argentina during the Fall 2018.
[2]
oai:arXiv.org:1609.04372 [pdf] - 1576378
QUBIC Technical Design Report
Aumont, J.;
Banfi, S.;
Battaglia, P.;
Battistelli, E. S.;
Baù, A.;
Bélier, B.;
Bennett, D.;
Bergé, L.;
Bernard, J. Ph.;
Bersanelli, M.;
Bigot-Sazy, M. A.;
Bleurvacq, N.;
Bordier, G.;
Brossard, J.;
Bunn, E. F.;
Buzi, D.;
Buzzelli, A.;
Cammilleri, D.;
Cavaliere, F.;
Chanial, P.;
Chapron, C.;
Coppi, G.;
Coppolecchia, A.;
Couchot, F.;
D'Agostino, R.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Petris, M.;
Decourcelle, T.;
Del Torto, F.;
Dumoulin, L.;
Etchegoyen, A.;
Franceschet, C.;
Garcia, B.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Ghribi, A.;
Giard, M.;
Giraud-Héraud, Y.;
Gradziel, M.;
Grandsire, L.;
Hamilton, J. Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versillé, S.;
Holtzer, N.;
Kaplan, J.;
Korotkov, A.;
Lamagna, L.;
Lande, J.;
Loucatos, S.;
Lowitz, A.;
Lukovic, V.;
Maffei, B.;
Marnieros, S.;
Martino, J.;
Masi, S.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Melhuish, S.;
Mennella, A.;
Montier, L.;
Murphy, A.;
Néel, D.;
Ng, M. W.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pelosi, A.;
Perbost, C.;
Perdereau, O.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Prêle, D.;
Puddu, R.;
Rambaud, D.;
Rigaut, O.;
Romero, G. E.;
Salatino, M.;
Schillaci, A.;
Scully, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Tristram, M.;
Tucker, G.;
Viganò, D.;
Vittori, N.;
Voisin, F.;
Watson, B.;
Zannoni, M.;
Zullo, A.
Submitted: 2016-09-14, last modified: 2017-05-11
QUBIC is an instrument aiming at measuring the B mode polarisation
anisotropies at medium scales angular scales (30-200 multipoles). The search
for the primordial CMB B-mode polarization signal is challenging, because of
many difficulties: smallness of the expected signal, instrumental systematics
that could possibly induce polarization leakage from the large E signal into B,
brighter than anticipated polarized foregrounds (dust) reducing to zero the
initial hope of finding sky regions clean enough to have a direct primordial
B-modes observation. The QUBIC instrument is designed to address all aspects of
this challenge with a novel kind of instrument, a Bolometric Interferometer,
combining the background-limited sensitivity of Transition-Edge-Sensors and the
control of systematics allowed by the observation of interference fringe
patterns, while operating at two frequencies to disentangle polarized
foregrounds from primordial B mode polarization. Its characteristics are
described in details in this Technological Design Report.
[3]
oai:arXiv.org:1307.5701 [pdf] - 1172881
Latest Progress on the QUBIC Instrument
Ghribi, A.;
Aumont, J.;
Battistelli, E. S.;
Bau, A.;
Bergé, L.;
Bernard, J-Ph.;
Bersanelli, M.;
Bigot-Sazy, M-A.;
Bordier, G.;
Bunn, E. T.;
Cavaliere, F.;
Chanial, P.;
Coppolecchia, A.;
Decourcelle, T.;
De Bernardis, P.;
De Petris, M.;
Drilien, A-A.;
Dumoulin, L.;
Falvella, M. C.;
Gault, A.;
Gervasi, M.;
Giard, M.;
Gradziel, M.;
Grandsire, L.;
Gayer, D.;
Hamilton, J-Ch.;
Haynes, V.;
Giraud-Héraud, Y.;
Holtzer, N.;
Kaplan, J.;
Korotkov, A.;
Lande, J.;
Lowitz, A.;
Maffei, B.;
Marnieros, S.;
Martino, J.;
Masi, S.;
Mennella, A.;
Montier, L.;
Murphy, A.;
Ng, M. W.;
Olivieri, E.;
Pajot, F.;
Passerini, A.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Prêle, D.;
Rambaud, D.;
Rigaut, O.;
Rosset, C.;
Salatino, M.;
Schillaci, A.;
Scully, S.;
O'Sullivan, C.;
Tartari, A.;
Timbie, P.;
Tucker, G.;
Vibert, L.;
Voisin, F.;
Watson, B.;
Zannoni, M.
Submitted: 2013-07-22, last modified: 2013-11-12
QUBIC is a unique instrument that crosses the barriers between classical
imaging architectures and interferometry taking advantage from both for high
sensitivity and systematics mitigation. The scientific target is the detection
of the primordial gravitational waves imprint on the Cosmic Microwave
Background which are the proof of inflation, holy grail of modern cosmology. In
this paper, we show the latest advances in the development of the architecture
and the sub-systems of the first module of this instrument to be deployed in
Dome Charlie Concordia base - Antarctica in 2015.
[4]
oai:arXiv.org:1307.1488 [pdf] - 844079
Axion searches with the EDELWEISS-II experiment
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoit, A.;
Benoit, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Couëdo, F.;
Coulter, P.;
Cox, G. A.;
de Boissière, T.;
De Jesus, M.;
Dolgorouky, Y.;
Drillien, A. A.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hehn, L.;
Henry, S.;
Hervé, S.;
Heuermann, G.;
Holtzer, N.;
Humbert, V.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Sueur, H. Le;
Mancuso, M.;
Marrache-Kikuchi, C.;
Marnieros, S.;
Menshikov, A.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. C.;
Rigaut, O.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Siebenborn, B.;
Tcherniakhovski, D.;
Tenconi, M.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2013-07-04
We present new constraints on the couplings of axions and more generic
axion-like particles using data from the EDELWEISS-II experiment. The EDELWEISS
experiment, located at the Underground Laboratory of Modane, primarily aims at
the direct detection of WIMPs using germanium bolometers. It is also sensitive
to the low-energy electron recoils that would be induced by solar or dark
matter axions. Using a total exposure of up to 448 kg.d, we searched for
axion-induced electron recoils down to 2.5 keV within four scenarios involving
different hypotheses on the origin and couplings of axions. We set a 95% CL
limit on the coupling to photons $g_{A\gamma}<2.13\times 10^{-9}$ GeV$^{-1}$ in
a mass range not fully covered by axion helioscopes. We also constrain the
coupling to electrons, $g_{Ae} < 2.56\times 10^{-11}$, similar to the more
indirect solar neutrino bound. Finally we place a limit on $g_{Ae}\times
g_{AN}^{\rm eff}<4.70 \times 10^{-17}$, where $g_{AN}^{\rm eff}$ is the
effective axion-nucleon coupling for $^{57}$Fe. Combining these results we
fully exclude the mass range $0.91\,{\rm eV}<m_A<80$ keV for DFSZ axions and
$5.73\,{\rm eV}<m_A<40$ keV for KSVZ axions.
[5]
oai:arXiv.org:1210.3267 [pdf] - 689043
High-impedence NbSi TES sensors for studying the cosmic microwave
background radiation
Submitted: 2012-10-11
Precise measurements of the cosmic microwave background (CMB) are crucial in
cosmology, because any proposed model of the universe must account for the
features of this radiation. Of all CMB measurements that the scientific
community has not yet been able to perform, the CMB B-mode polarization is
probably the most challenging from the instrumental point of view. The
signature of primordial gravitational waves, which give rise to a B-type
polarization, is one of the goals in cosmology today and amongst the first
objectives in the field. For this purpose, high-performance low-temperature
bolometric cameras, made of thousands of pixels, are currently being developed
by many groups, which will improve the sensitivity to B-mode CMB polarization
by one or two orders of magnitude compared to the Planck satellite HFI
detectors. We present here a new bolometer structure that is able to increase
the pixel sensitivities and to simplify the fabrication procedure. This
innovative device replaces delicate membrane-based structures and eliminates
the mediation of phonons: the incoming energy is directly captured and measured
in the electron bath of an appropriate sensor and the thermal decoupling is
achieved via the intrinsic electron-phonon decoupling of the sensor at very low
temperature. Reported results come from a 204-pixel array of Nb$_{x}$Si$_{1-x}$
transition edge sensors with a meander structure fabricated on a 2-inch silicon
wafer using electron-beam co-evaporation and a cleanroom lithography process.
To validate the application of this device to CMB measurements, we have
performed an optical calibration of our sample in the focal plane of a dilution
cryostat test bench. We have demonstrated a light absorption close to 20% and
an NEP of about 7$\times10^{-16}$ W/$\sqrt{Hz}$, which is highly encouraging
given the scope for improvement in this type of detectors.