sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Ridder, Marcel

Normalized to: Ridder, M.

8 article(s) in total. 54 co-authors, from 1 to 6 common article(s). Median position in authors list is 8,5.

[1]  oai:arXiv.org:2002.08447  [pdf] - 2080999
Cataclysmic Variables in the First Year of the Zwicky Transient Facility
Comments: 27 pages, 9 figures, 3 tables
Submitted: 2020-02-19
Using selection criteria based on amplitude, time and color, we have identified 329 objects as known or candidate cataclysmic variable (CVs) during the first year of testing and operation of the Zwicky Transient Facility (ZTF). Of these, 90 are previously confirmed CVs, 218 are strong candidates based on the shape and color of their light curves obtained during 3-562 days of observations, and the remaining 21 are possible CVs but with too few data points to be listed as good candidates. Almost half the strong candidates are within 10 deg of the galactic plane, in contrast to most other large surveys which have avoided crowded fields. The available Gaia parallaxes are consistent with sampling the low mass transfer CVs, as predicted by population models. Our followup spectra have confirmed Balmer/helium emission lines in 27 objects, with four showing high excitation HeII emission, including candidates for an AM CVn, a polar and an intermediate polar. Our results demonstrate that a complete survey of the galactic plane is needed to accomplish an accurate determination of the number of CVs existing in the Milky Way.
[2]  oai:arXiv.org:1807.06423  [pdf] - 1718603
The SAFARI Detector System
Comments: 7 pages, 3 figures, Proc. SPIE 10708, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy IX, 107080K (9 July 2018); (fixed typo in abstract)
Submitted: 2018-07-17, last modified: 2018-07-18
We give an overview of the baseline detector system for SAFARI, the prime focal-plane instrument on board the proposed space infrared observatory, SPICA. SAFARI's detectors are based on superconducting Transition Edge Sensors (TES) to provide the extreme sensitivity (dark NEP$\le2\times10^{-19}\rm\ W/\sqrt Hz$) needed to take advantage of SPICA's cold (<8 K) telescope. In order to read out the total of ~3500 detectors we use frequency domain multiplexing (FDM) with baseband feedback. In each multiplexing channel, a two-stage SQUID preamplifier reads out 160 detectors. We describe the detector system and discuss some of the considerations that informed its design.
[3]  oai:arXiv.org:1608.06843  [pdf] - 1462591
Optical performance of prototype horn-coupled TES bolometer arrays for SAFARI
Comments: 9 pages, 8 figures. Copyright 2016 Society of Photo Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited
Submitted: 2016-08-24
The SAFARI Detector Test Facility is an ultra-low background optical testbed for characterizing ultra-sensitive prototype horn-coupled TES bolmeters for SAFARI, the grating spectrometer on board the proposed SPICA satellite. The testbed contains internal cold and hot black-body illuminators and a light-pipe for illumination with an external source. We have added reimaging optics to facilitate array optical measurements. The system is now being used for optical testing of prototype detector arrays read out with frequency-domain multiplexing. We present our latest optical measurements of prototype arrays and discuss these in terms of the instrument performance.
[4]  oai:arXiv.org:1604.02600  [pdf] - 1388309
A multiplexer for the ac/dc characterization of TES based bolometers and microcalorimeters
Comments: 7 pages, 6 figures, Proc. SPIE 8453, High Energy, Optical, and Infrared Detectors for Astronomy V, 845333 (25 September 2012). arXiv admin note: text overlap with arXiv:1604.02593
Submitted: 2016-04-09
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the read-out of the TES-based detector array for the future infrared and X-ray space mission. We describe the performances of a multiplexer designed to increase the experimental throughput in the characterisation of ultra-low noise equivalent power (NEP) TES bolometers and high energy resolving power X-ray microcalorimeters arrays under ac and dc bias. We discuss the results obtained using the TiAu TES bolometers array fabricated at SRON with measured dark NEP below $5\cdot 10^{-19}W/Hz^{1/2}$ and saturation power of several fW
[5]  oai:arXiv.org:1604.02593  [pdf] - 1388308
AC bias characterization of low noise bolometers for SAFARI using an Open-Loop Frequency Domain SQUID-based multiplexer operating between 1 and 5 MHz
Comments: 6 pages, 5 figures
Submitted: 2016-04-09
SRON is developing the Frequency Domain Multiplexing (FDM) readout and the ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on board of the Japanese space mission SPICA. The FDM prototype of the instrument requires critical and complex optimizations. For single pixel characterization under AC bias we are developing a simple FDM system working in the frequency range from 1 to 5 MHz, based on the open loop read-out of a linearized two-stage SQUID amplifier and high Q lithographic LC resonators. We describe the details of the experimental set-up required to achieve low power loading (< 1 fW) and low noise (NEP $\sim 10^{-19} W/Hz^{1/2}$) in the TES bolometers. We conclude the paper by comparing the performance of a $4 \cdot 10^{-19} W/Hz^{1/2}$ TES bolometer measured under DC and AC bias.
[6]  oai:arXiv.org:1604.00680  [pdf] - 1384872
Weak-Link Phenomena in AC-Biased Transition Edge Sensors
Comments: 6 pages, 5 figure
Submitted: 2016-04-03
It has been recently demonstrated that superconducting transition edge sensors (TESs) behave as weak-links due to longitudinally induced superconductivity from the leads with higher Tc. In this work we study the implication of this behaviour for TES-based bolometers and microcalorimeter under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a Frequency Domain Multiplexer based on a linearised two-stage SQUID amplifier and high- Q lithographically made superconducting LC resonators. In particular, we focus on SRON TiAu TES bolometers with a measured dark Noise Equivalent Power (NEP) of $3.2 \cdot 10^{-19} W/Hz^{1/2}$ developed for the short wavelength band for the instrument SAFARI on the SPICA telescope.
[7]  oai:arXiv.org:1604.00553  [pdf] - 1384861
Development of TES-based detectors array for the X-ray Integral Field Unit (X-IFU) on the future x-ray observatory ATHENA
Comments: 9 pages, 8 figures
Submitted: 2016-04-02
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with different wiring topology to mitigate the self-magnetic field. The design is tailored to optimise the performance under Frequency Domain Multiplexing. In this paper we review the main design feature of the pixels array and we report on the performance of the 18 channels, 2-5MHz frequency domain multiplexer that will be used to characterised the detector array.
[8]  oai:arXiv.org:1603.07944  [pdf] - 1388264
Optical performance of an ultra-sensitive horn-coupled transition-edge-sensor bolometer with hemispherical backshort in the far infrared
Comments: 22 pages, 11 figures. The following article has been accepted by Review of Scientific Instruments. After it is published, it will be found at http://scitation.aip.org/content/aip/journal/rsi
Submitted: 2016-03-25
The next generation of far infrared space observatories will require extremely sensitive detectors that can be realized only by combining extremely low intrinsic noise with high optical efficiency. We have measured the broad-band optical response of ultra-sensitive TES bolometers (NEP$\approx2\rm\ aW/\sqrt Hz$) in the 30--60-$\mu\rm m$ band where radiation is coupled to the detectors with a few-moded conical feedhorn and a hemispherical backshort. We show that these detectors have an optical efficiency of 60% (the ratio of the power detected by the TES bolometer to the total power propagating through the feedhorn). We find that the measured optical efficiency can be understood in terms of the modes propagating through the feedhorn with the aid of a spatial mode-filtering technique.