Ridder, Marcel
Normalized to: Ridder, M.
8 article(s) in total. 54 co-authors, from 1 to 6 common article(s). Median position in authors list is 8,5.
[1]
oai:arXiv.org:2002.08447 [pdf] - 2080999
Cataclysmic Variables in the First Year of the Zwicky Transient Facility
Szkody, Paula;
Dicenzo, Brooke;
Ho, Anna Y. Q.;
Hillenbrand, Lynne A.;
van Roestel, Jan;
Ridder, Margaret;
Lima, Isabel DeJesus;
Graham, Melissa L.;
Bellm, Eric C.;
Burdge, Kevin;
Kupfer, Thomas;
Prince, Thomas A.;
Masci, Frank J.;
Mroz, Przemyslaw J.;
Golkhou, V. Zach;
Coughlin, Michael;
Cunningham, Virginia A.;
Dekany, Richard;
Graham, Matthew J.;
Hale, David;
Kaplan, David;
Kasliwal, Mansi M.;
Miller, Adam A.;
Neill, James D.;
Patterson, Maria T.;
Riddle, Reed;
Smith, Roger;
Soumagnac, Maayanne T.
Submitted: 2020-02-19
Using selection criteria based on amplitude, time and color, we have
identified 329 objects as known or candidate cataclysmic variable (CVs) during
the first year of testing and operation of the Zwicky Transient Facility (ZTF).
Of these, 90 are previously confirmed CVs, 218 are strong candidates based on
the shape and color of their light curves obtained during 3-562 days of
observations, and the remaining 21 are possible CVs but with too few data
points to be listed as good candidates. Almost half the strong candidates are
within 10 deg of the galactic plane, in contrast to most other large surveys
which have avoided crowded fields. The available Gaia parallaxes are consistent
with sampling the low mass transfer CVs, as predicted by population models. Our
followup spectra have confirmed Balmer/helium emission lines in 27 objects,
with four showing high excitation HeII emission, including candidates for an AM
CVn, a polar and an intermediate polar. Our results demonstrate that a complete
survey of the galactic plane is needed to accomplish an accurate determination
of the number of CVs existing in the Milky Way.
[2]
oai:arXiv.org:1807.06423 [pdf] - 1718603
The SAFARI Detector System
Audley, Michael D.;
de Lange, Gert;
Gao, Jian-Rong;
Jackson, Brian D.;
Hijmering, Richard A.;
Ridder, Marcel L.;
Bruijn, Marcel P.;
Roelfsema, Peter R.;
Ade, Peter A. R.;
Withington, Stafford;
Bradford, Charles M.;
Trappe, Neal A.
Submitted: 2018-07-17, last modified: 2018-07-18
We give an overview of the baseline detector system for SAFARI, the prime
focal-plane instrument on board the proposed space infrared observatory, SPICA.
SAFARI's detectors are based on superconducting Transition Edge Sensors (TES)
to provide the extreme sensitivity (dark NEP$\le2\times10^{-19}\rm\ W/\sqrt
Hz$) needed to take advantage of SPICA's cold (<8 K) telescope. In order to
read out the total of ~3500 detectors we use frequency domain multiplexing
(FDM) with baseband feedback. In each multiplexing channel, a two-stage SQUID
preamplifier reads out 160 detectors. We describe the detector system and
discuss some of the considerations that informed its design.
[3]
oai:arXiv.org:1608.06843 [pdf] - 1462591
Optical performance of prototype horn-coupled TES bolometer arrays for
SAFARI
Submitted: 2016-08-24
The SAFARI Detector Test Facility is an ultra-low background optical testbed
for characterizing ultra-sensitive prototype horn-coupled TES bolmeters for
SAFARI, the grating spectrometer on board the proposed SPICA satellite. The
testbed contains internal cold and hot black-body illuminators and a light-pipe
for illumination with an external source. We have added reimaging optics to
facilitate array optical measurements. The system is now being used for optical
testing of prototype detector arrays read out with frequency-domain
multiplexing. We present our latest optical measurements of prototype arrays
and discuss these in terms of the instrument performance.
[4]
oai:arXiv.org:1604.02600 [pdf] - 1388309
A multiplexer for the ac/dc characterization of TES based bolometers and
microcalorimeters
Gottardi, Luciano;
Akamatsu, Hiroki;
Bruijn, Marcel;
Gao, Jan R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
van der Kuur, Jan;
van der Linden, Anoton;
Lindeman, Marcel;
Ridder, Marcel
Submitted: 2016-04-09
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the
read-out of the TES-based detector array for the future infrared and X-ray
space mission. We describe the performances of a multiplexer designed to
increase the experimental throughput in the characterisation of ultra-low noise
equivalent power (NEP) TES bolometers and high energy resolving power X-ray
microcalorimeters arrays under ac and dc bias. We discuss the results obtained
using the TiAu TES bolometers array fabricated at SRON with measured dark NEP
below $5\cdot 10^{-19}W/Hz^{1/2}$ and saturation power of several fW
[5]
oai:arXiv.org:1604.02593 [pdf] - 1388308
AC bias characterization of low noise bolometers for SAFARI using an
Open-Loop Frequency Domain SQUID-based multiplexer operating between 1 and 5
MHz
Gottardi, Luciano;
Bruijn, Marcel;
Gao, Jan-R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
de Korte, Piet;
van der Kuur, Jan;
Lindeman, Mark;
Ridder, Marcel
Submitted: 2016-04-09
SRON is developing the Frequency Domain Multiplexing (FDM) readout and the
ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on
board of the Japanese space mission SPICA. The FDM prototype of the instrument
requires critical and complex optimizations. For single pixel characterization
under AC bias we are developing a simple FDM system working in the frequency
range from 1 to 5 MHz, based on the open loop read-out of a linearized
two-stage SQUID amplifier and high Q lithographic LC resonators. We describe
the details of the experimental set-up required to achieve low power loading (<
1 fW) and low noise (NEP $\sim 10^{-19} W/Hz^{1/2}$) in the TES bolometers. We
conclude the paper by comparing the performance of a $4 \cdot 10^{-19}
W/Hz^{1/2}$ TES bolometer measured under DC and AC bias.
[6]
oai:arXiv.org:1604.00680 [pdf] - 1384872
Weak-Link Phenomena in AC-Biased Transition Edge Sensors
Gottardi, Luciano;
Akamatsu, Hiroki;
Bruijn, Marcel;
Gao, Jan-R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
Kozorezov, Alex;
van der Kuur, Jan;
van der Linden, Anton;
Ridder, Marcel
Submitted: 2016-04-03
It has been recently demonstrated that superconducting transition edge
sensors (TESs) behave as weak-links due to longitudinally induced
superconductivity from the leads with higher Tc. In this work we study the
implication of this behaviour for TES-based bolometers and microcalorimeter
under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a
Frequency Domain Multiplexer based on a linearised two-stage SQUID amplifier
and high- Q lithographically made superconducting LC resonators. In particular,
we focus on SRON TiAu TES bolometers with a measured dark Noise Equivalent
Power (NEP) of $3.2 \cdot 10^{-19} W/Hz^{1/2}$ developed for the short
wavelength band for the instrument SAFARI on the SPICA telescope.
[7]
oai:arXiv.org:1604.00553 [pdf] - 1384861
Development of TES-based detectors array for the X-ray Integral Field
Unit (X-IFU) on the future x-ray observatory ATHENA
Gottardi, Luciano;
Akamatsu, Hiroki;
Barret, Didier;
Bruijn, Marcel P.;
Hartog, Roland H. den;
Herder, Jan-Willem den;
Hoevers, Henk F. C.;
Kiviranta, Mikko;
van der Kuur, Jan;
van der Linden, Anton J.;
Jackson, Brian D.;
Jambunathan, Madu;
Ridder, Marcel L.
Submitted: 2016-04-02
We are developing transition-edge sensor (TES)-based microcalorimeters for
the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory
Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m
squared, AuBi absorbers. We designed and fabricated devices with different
contact geometries between the absorber and the TES to optimise the detector
performance and with different wiring topology to mitigate the self-magnetic
field. The design is tailored to optimise the performance under Frequency
Domain Multiplexing. In this paper we review the main design feature of the
pixels array and we report on the performance of the 18 channels, 2-5MHz
frequency domain multiplexer that will be used to characterised the detector
array.
[8]
oai:arXiv.org:1603.07944 [pdf] - 1388264
Optical performance of an ultra-sensitive horn-coupled
transition-edge-sensor bolometer with hemispherical backshort in the far
infrared
Audley, Michael D.;
de Lange, Gert;
Gao, Jian-Rong;
Khosropanah, Pourya;
Hijmering, Richard;
Ridder, Marcel;
Mauskopf, Philip D.;
Morozov, Dmitry;
Trappe, Neil A.;
Doherty, Stephen
Submitted: 2016-03-25
The next generation of far infrared space observatories will require
extremely sensitive detectors that can be realized only by combining extremely
low intrinsic noise with high optical efficiency. We have measured the
broad-band optical response of ultra-sensitive TES bolometers (NEP$\approx2\rm\
aW/\sqrt Hz$) in the 30--60-$\mu\rm m$ band where radiation is coupled to the
detectors with a few-moded conical feedhorn and a hemispherical backshort. We
show that these detectors have an optical efficiency of 60% (the ratio of the
power detected by the TES bolometer to the total power propagating through the
feedhorn). We find that the measured optical efficiency can be understood in
terms of the modes propagating through the feedhorn with the aid of a spatial
mode-filtering technique.