sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Richardson, E. Harvey

Normalized to: Richardson, E.

4 article(s) in total. 15 co-authors, from 1 to 2 common article(s). Median position in authors list is 3,5.

[1]  oai:arXiv.org:1312.5471  [pdf] - 1202371
The PRL Stabilized High Resolution Echelle Fiber-fed Spectrograph: Instrument Description & First Radial Velocity Results
Comments: 33 pages, 15 figures, accepted for publication in PASP
Submitted: 2013-12-19
We present spectrograph design details and initial radial velocity results from the PRL optical fiber-fed high-resolution cross-dispersed echelle spectrograph (PARAS), which has recently been commissioned at the Mt Abu 1.2 m telescope, in India. Data obtained as part of the post-commissioning tests with PARAS show velocity precision better than 2m/s over a period of several months on bright RV standard stars. For observations of sigma-Dra we report 1.7m/s precision for a period of seven months and 2.1m/s for HD 9407 over a period of 2 months. PARAS is capable of a single-shot spectral coverage of 3800A - 9500A at a resolution of about 67,000. The RV results were obtained between 3800A and 6900A using simultaneous wavelength calibration with a Thorium-Argon (ThAr) hollow cathode lamp. The spectrograph is maintained under stable conditions of temperature with a precision of 0.01 - 0.02C (rms) at 25.55C, and enclosed in a vacuum vessel at pressure of 0.1 +/-0.03 mbar. The blaze peak efficiency of the spectrograph between 5000A and 6500A, including the detector, is 30%; and about 25% with the fiber transmission. The total efficiency, including spectrograph, fiber transmission, focal ratio degradation (FRD), and telescope (with 81% reflectivity) is about 7% in the same wavelength region on a clear night with good seeing conditions.
[2]  oai:arXiv.org:1007.4280  [pdf] - 1033890
First Light results from PARAS: The PRL Echelle Spectrograph
Comments: To appear in SPIE Proc. 2010, vol. 7035
Submitted: 2010-07-24
We present the first light commissioning results from the Physical Research Laboratory (PRL) optical fiber-fed high resolution cross-dispersed Echelle Spectrograph. It is capable of a single- shot spectral coverage of 3700A to 8600A at R ~ 63,000 and is under very stable conditions of temperature (0.04{\deg}C at 23{\deg}C). In the very near future pressure control will also be achieved by enclosing the entire spectrograph in a low-pressure vacuum chamber (~0.01mbar). It is attached to a 1.2m telescope using two 50micron core optical fibers (one for the star and another for simultaneous Th-Ar spectral calibration). The 1.2m telescope is located at Mt. Abu, India, and we are guaranteed about 80 to 100 nights a year for observations with the spectrograph. The instrument will be ultimately used for radial-velocity searches of exoplanets around 1000 dwarf stars, brighter than 10th magnitude, for the next 5 years with a precision of 3 to 5m/s using the simultaneous Th-Ar spectral lamp reference technique. The spectrograph has already achieved a stability of 3.7m/s in short-term time scale and in the near future we expect the stability to be at 1m/s once we install the spectrograph inside the vacuum chamber.
[3]  oai:arXiv.org:astro-ph/9911170  [pdf] - 109298
Focussing Image Slicers: Refractive and Reflective
Comments: 4 pages, 1 figure, to be published in "Imaging the Universe in Three Dimensions", ASP Conf. Series, in press, van Breugel & Bland-Hawthorn (eds.). Requires pasp3D.sty
Submitted: 1999-11-10
A number of design options for image slicers for NGST and Gemini are being investigated. These image slicers are all of the focussing type and both refractive and reflective solutions are being explored. One such device, an image slicer that focuses 10 slices on a spectrograph slit is now in operation at the McMath Solar telescope. It consists of three lenslet arrays, and additionally acts as a focal reducer and provides correction for astigmatism of the telescope. A combined refractive and reflective slicer designed for use on NGST delivers near-diffraction limited images for up to 40 slices.
[4]  oai:arXiv.org:astro-ph/9806303  [pdf] - 101896
A Curvature-Compensated Corrector for Drift-Scan Observations
Comments: 17 pages, PASP in press
Submitted: 1998-06-22
Images obtained by drift-scanning with a stationary telescope are affected by the declination-dependent curvature of star trails. The image displacement to curvature and drift rate variation increases with the angular field of view and can lead to significant loss of resolution with modern large-format CCD arrays. We show that these effects can be essentially eliminated by means of an optical corrector design in which individual lenses are tilted and decentered. A specific example is presented, of a four-element corrector designed for the Large-Zenith Telescope. The design reduces curvature errors to less than 0.074 arcsec over a 10 arcmin x 20 arcmin field of view centered at 49 degrees declination. By changing the positions and tilts of the lenses, the same design can also be used for any field centers between 0 degrees and 49 degrees.