Large-area Si(Li) Detectors for X-ray Spectrometry and Particle Tracking for the GAPS Experiment
Comments:
Submitted: 2019-12-13
Large-area lithium-drifted silicon (Si(Li)) detectors, operable 150{\deg}C above liquid nitrogen temperature, have been developed for the General Antiparticle Spectrometer (GAPS) balloon mission and will form the first such system to operate in space. These 10 cm-diameter, 2.5 mm-thick multi-strip detectors have been verified in the lab to provide <4 keV FWHM energy resolution for X-rays as well as tracking capability for charged particles, while operating in conditions (~-40{\deg}C and ~1 Pa) achievable on a long-duration balloon mission with a large detector payload. These characteristics enable the GAPS silicon tracker system to identify cosmic antinuclei via a novel technique based on exotic atom formation, de-excitation, and annihilation. Production and large-scale calibration of ~1000 detectors has begun for the first GAPS flight, scheduled for late 2021. The detectors developed for GAPS may also have other applications, for example in heavy nuclei identification.
[2]  oai:arXiv.org:1906.00054  [pdf] - 1995412
Large-area Si(Li) detectors for X-ray spectrometry and particle tracking in the GAPS experiment
Comments: Accepted for publication at JINST, 16 pages, 8 figures
Submitted: 2019-05-31, last modified: 2019-11-08
The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique geometric, performance, and cost requirements of the General Antiparticle Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The GAPS Si(Li) detectors will form the first large-area, relatively high-temperature Si(Li) detector system with sensitivity to X-rays to operate at high altitude. These 10 cm-diameter, 2.5 mm-thick, 4- or 8-strip detectors provide the active area, X-ray absorption efficiency, energy resolution, and particle tracking capability necessary for the GAPS exotic-atom particle identification technique. In this paper, the detector performance is validated on the bases of X-ray energy resolution and reconstruction of cosmic minimum ionizing particle (MIP) signals. We use the established noise model for semiconductor detectors to distinguish sources of noise due to the detector from those due to signal processing electronics. We demonstrate that detectors with either 4 strips or 8 strips can provide the required $\lesssim$4 keV (FWHM) X-ray energy resolution at flight temperatures of $-35$ to $-45^{\circ}$C, given the proper choice of signal processing electronics. Approximately 1000 8-strip detectors will be used for the first GAPS Antarctic balloon flight, scheduled for late 2021.
[3]  oai:arXiv.org:1909.01682  [pdf] - 1955438
Front-end electronics for the GAPS tracker
Comments: 7 pages, 3 figures 36th International Cosmic Ray Conference -ICRC2019- July 24th - August 1st
Submitted: 2019-09-04
The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon-borne mission to indirectly search for dark matter through sensitive observation of cosmic antiparticles. The first flight is planned for late 2021. GAPS is the first experiment optimized specifically for detection of low-energy (< 0.25 GeV/n) antideuterons, which are recognized as distinctive signals from dark matter annihilation or decay in the Galactic halo. To achieve high sensitivity to cosmic antinuclei in this low-energy range, GAPS uses a novel particle identification method based on exotic atom capture and decay. The GAPS instrument consists of ten planes of 1440 10 cm-diameter, 2.5 mm-thick, 8-strip lithium drifted silicon (Si(Li)) detectors, which constitutes the tracker, surrounded by a plastic scintillator time-of-flight system. A new fabrication technique has been developed to satisfy the stringent requirements of the mission. In this contribution, we describe the front-end electronics of the tracker of GAPS. The system is composed of front-end ASICs and power supplies. The ASICs provide readout and digitization of the signal (with an 11-bit ADC) in a wide dynamic range (10 keV - 100 MeV). Every ASIC has 32 channels and performs the readout for 4 detectors, for a total amount of 11520 channels. The ASIC analog front-end is based on a dynamic compression technique to handle a large range of signal amplitudes and features a low noise performance, achieving the required 4 keV resolution at low energies. The power system supplies both bias voltages for the Si(Li) detectors and low voltages for the electronics. 36th
[4]  oai:arXiv.org:1908.03154  [pdf] - 1931578
GAPS: Searching for Dark Matter using Antinuclei in Cosmic Rays
Comments: 8 pages, 7 figures, Proc. 36th International Cosmic Ray Conference (ICRC 2019), Madison, USA
Submitted: 2019-08-08
The General Antiparticle Spectrometer (GAPS) will carry out a sensitive dark matter search by measuring low-energy ($\mathrm{E} < 0.25 \mathrm{GeV/nucleon}$) cosmic ray antinuclei. The primary targets are low-energy antideuterons produced in the annihilation or decay of dark matter. At these energies antideuterons from secondary/tertiary interactions are expected to have very low fluxes, significantly below those predicted by well-motivated, beyond the standard model theories. GAPS will also conduct low-energy antiproton and antihelium searches. Combined, these observations will provide a powerful search for dark matter and provide the best observations to date on primordial black hole evaporation on Galactic length scales. The GAPS instrument detects antinuclei using the novel exotic atom technique. It consists of a central tracker with a surrounding time-of-flight (TOF) system. The tracker is a one cubic meter volume containing 10 cm-diameter lithium-drifted silicon (Si(Li)) detectors. The TOF is a plastic scintillator system that will both trigger the Si(Li) tracker and enable better reconstruction of particle tracks. After coming to rest in the tracker, antinuclei will form an excited exotic atom. This will then de-excite via characteristic X-ray transitions before producing a pion/proton star when the antiparticle annihilates with the nucleus. This unique event topology will give GAPS the nearly background-free detection capability required for a rare-event search. Here we present the scientific motivation for the GAPS experiment, its design and its current status as it prepares for flight in the austral summer of 2021-22.