sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Reynaud, F.

Normalized to: Reynaud, F.

4 article(s) in total. 114 co-authors, from 1 to 2 common article(s). Median position in authors list is 5,0.

[1]  oai:arXiv.org:1703.03919  [pdf] - 1581889
AGILIS: Agile Guided Interferometer for Longbaseline Imaging Synthesis - Demonstration and concepts of reconfigurable optical imaging interferometers
Comments: 16 pages, 10 figures, 2 tables, accepted in A&A
Submitted: 2017-03-11
In comparison to the radio and sub-millimetric domains, imaging with optical interferometry is still in its infancy. Due to the limited number of telescopes in existing arrays, image generation is a demanding process that relies on time-consuming reconfiguration of the interferometer array and super-synthesis. Using single mode optical fibres for the coherent transport of light from the collecting telescopes to the focal plane, a new generation of interferometers optimized for imaging can be designed. To support this claim, we report on the successful completion of the `OHANA Iki project: an end-to-end, on-sky demonstration of a two-telescope interferometer, built around near-infrared single mode fibres, carried out as part of the `OHANA project. Having demonstrated that coherent transport by single-mode fibres is feasible, we explore the concepts, performances, and limitations of a new imaging facility with single mode fibres at its heart: Agile Guided Interferometer for Longbaseline Imaging Synthesis (AGILIS). AGILIS has the potential of becoming a next generation facility or a precursor to a much larger project like the Planet Formation Imager (PFI).
[2]  oai:arXiv.org:1009.1953  [pdf] - 1034866
First experimental demonstration of temporal hypertelescope operation with a laboratory prototype
Comments: Accepted for publication in MNRAS. 11 pages, 25 figures
Submitted: 2010-09-10
In this paper, we report the first experimental demonstration of a Temporal HyperTelescope (THT). Our breadboard including 8 telescopes is firstly tested in a manual cophasing configuration on a 1D object. The Point Spread Function (PSF) is measured and exhibits a dynamics in the range of 300. A quantitative analysis of the potential biases demonstrates that this limitation is related to the residual phase fluctuation on each interferometric arm. Secondly, an unbalanced binary star is imaged demonstrating the imaging capability of THT. In addition, 2D PSF is recorded even if the telescope array is not optimized for this purpose.
[3]  oai:arXiv.org:astro-ph/0610936  [pdf] - 86360
Direct constraint on the distance of y2 Velorum from AMBER/VLTI observations
Comments:
Submitted: 2006-10-31
In this work, we present the first AMBER observations, of the Wolf-Rayet and O (WR+O) star binary system y2 Velorum. The AMBER instrument was used with the telescopes UT2, UT3, and UT4 on baselines ranging from 46m to 85m. It delivered spectrally dispersed visibilities, as well as differential and closure phases, with a resolution R = 1500 in the spectral band 1.95-2.17 micron. We interpret these data in the context of a binary system with unresolved components, neglecting in a first approximation the wind-wind collision zone flux contribution. We show that the AMBER observables result primarily from the contribution of the individual components of the WR+O binary system. We discuss several interpretations of the residuals, and speculate on the detection of an additional continuum component, originating from the free-free emission associated with the wind-wind collision zone (WWCZ), and contributing at most to the observed K-band flux at the 5% level. The expected absolute separation and position angle at the time of observations were 5.1±0.9mas and 66±15° respectively. However, we infer a separation of 3.62+0.11-0.30 mas and a position angle of 73+9-11°. Our analysis thus implies that the binary system lies at a distance of 368+38-13 pc, in agreement with recent spectrophotometric estimates, but significantly larger than the Hipparcos value of 258+41-31 pc.
[4]  oai:arXiv.org:astro-ph/9907032  [pdf] - 107257
Integrated optics for astronomical interferometry. II. First laboratory white-light interferograms
Comments: 4 pages, 3 figures, accpeted by Astronomy and Astrophysics Supplement Series
Submitted: 1999-07-02
We report first white-light interferograms obtained with an integrated optics beam combiner on a glass plate. These results demonstrate the feasability of single-mode interferometric beam combination with integrated optics technology presented and discussed in paper I. The demonstration is achieved in laboratory with off-the-shelves components coming from micro-sensor applications, not optimized for astronomical use. These two-telescope beam combiners made by ion exchange technique on glass substrate provide laboratory white-light interferograms simultaneously with photometric calibration. A dedicated interferometric workbench using optical fibers is set up to characterize these devices. Despite the rather low match of the component parameters to astronomical constraints, we obtain stable contrasts higher than 93% with a 1.54-\micron laser source and up to 78% with a white-light source in the astronomical H band. Global throughput of 27% for a potassium ion exchange beam combiner and of 43% for a silver one are reached. This work validates our approach for combining several stellar beams of a long baseline interferometer with integrated optics components.