Normalized to: Resch, R.
[1]
oai:arXiv.org:1402.7137 [pdf] - 841566
Search for Low-Mass WIMPs with SuperCDMS
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Beaty, J.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cherry, M.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
DeVaney, D.;
Di Stefano, P. C. F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Hansen, S.;
Harris, H. R.;
Hertel, S. A.;
Hines, B. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kenany, S.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Nelson, R. H.;
Novak, L.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Platt, M.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Resch, R. W.;
Ricci, Y.;
Ruschman, M.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schmitt, R. L.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Serfass, B.;
Shank, B.;
Speller, D.;
Tomada, A.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-02-28, last modified: 2014-03-12
We report a first search for weakly interacting massive particles (WIMPs)
using the background rejection capabilities of SuperCDMS. An exposure of 577
kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region
blinded. Eleven events were observed after unblinding. We set an upper limit on
the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2.
This result is in tension with WIMP interpretations of recent experiments and
probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6
GeV/c2.
[2]
oai:arXiv.org:1305.2405 [pdf] - 1530127
Demonstration of Surface Electron Rejection with Interleaved Germanium
Detectors for Dark Matter Searches
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cherry, M.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hasi, J.;
Hertel, S. A.;
Hines, B. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kenany, S. A.;
Kennedy, A.;
Kenney, C. J.;
Kiveni, M.;
Koch, K.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Novak, L.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Radpour, R.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Resch, R. W.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schmitt, R.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Seitz, D.;
Serfass, B.;
Shank, B.;
Speller, D.;
Tomada, A.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-05-10, last modified: 2013-10-04
The SuperCDMS experiment in the Soudan Underground Laboratory searches for
dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric
sensors on opposite sides measure both charge and phonons from each particle
interaction, providing excellent discrimination between electron and nuclear
recoils, and between surface and interior events. Surface event rejection
capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta
decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal
region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L.,
corresponding to $< 0.6$ surface event background in the future 200-kg
SuperCDMS SNOLAB experiment.
[3]
oai:arXiv.org:1109.1198 [pdf] - 1083866
Monte Carlo Comparisons to a Cryogenic Dark Matter Search Detector with
low Transition-Edge-Sensor Transition Temperature
Leman, S. W.;
McCarthy, K. A.;
Brink, P. L.;
Cabrera, B.;
Cherry, M.;
Silva, E. Do Couto E;
Figueroa-Feliciano, E.;
Kim, P.;
Mirabolfathi, N.;
Pyle, M.;
Resch, R.;
Sadoulet, B.;
Serfass, B.;
Sundqvist, K. M.;
Tomada, A.;
Young, B. A.
Submitted: 2011-09-06
We present results on phonon quasidiffusion and Transition Edge Sensor (TES)
studies in a large, 3 inch diameter, 1 inch thick [100] high purity germanium
crystal, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed
with 59.5 keV gamma-rays from an Am-241 calibration source. We compare
calibration data with results from a Monte Carlo which includes phonon
quasidiffusion and the generation of phonons created by charge carriers as they
are drifted across the detector by ionization readout channels. The phonon
energy is then parsed into TES based phonon readout channels and input into a
TES simulator.
[4]
oai:arXiv.org:1109.0551 [pdf] - 1934625
Validation of Phonon Physics in the CDMS Detector Monte Carlo
McCarthy, K. A.;
Leman, S. W.;
Anderson, A. J.;
Brandt, D.;
Brink, P. L.;
Cabrera, B.;
Cherry, M.;
Silva, E. Do Couto E;
Cushman, P.;
Doughty, T.;
Figueroa-Feliciano, E.;
Kim, P.;
Mirabolfathi, N.;
Novak, L.;
Partridge, R.;
Pyle, M.;
Reisetter, A.;
Resch, R.;
Sadoulet, B.;
Serfass, B.;
Sundqvist, K. M.;
Tomada, A.
Submitted: 2011-09-02
The SuperCDMS collaboration is a dark matter search effort aimed at detecting
the scattering of WIMP dark matter from nuclei in cryogenic germanium targets.
The CDMS Detector Monte Carlo (CDMS-DMC) is a simulation tool aimed at
achieving a deeper understanding of the performance of the SuperCDMS detectors
and aiding the dark matter search analysis. We present results from validation
of the phonon physics described in the CDMS-DMC and outline work towards
utilizing it in future WIMP search analyses.
[5]
oai:arXiv.org:1108.6244 [pdf] - 1934623
Time Evolution of Electric Fields in CDMS Detectors
Leman, S. W.;
Brandt, D.;
Brink, P. L.;
Cabrera, B.;
Chagani, H.;
Cherry, M.;
Cushman, P.;
Silva, E. Do Couto E;
Doughty, T.;
Figueroa-Feliciano, E.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Pyle, M.;
Reisetter, A.;
Resch, R.;
Sadoulet, B.;
Serfass, B.;
Sundqvist, K. M.;
Tomada, A.;
Young, B. A.;
Zhang, J.
Submitted: 2011-08-31
The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3" diameter x 1"
thick target masses as particle detectors. The target is instrumented with both
phonon and ionization sensors, the later providing a $\sim$1 V cm$^{-1}$
electric field in the detector bulk. Cumulative radiation exposure which
creates $\sim 200\times 10^6$ electron-hole pairs is sufficient to produce a
comparable reverse field in the detector thereby degrading the ionization
channel performance. To study this, the existing CDMS detector Monte Carlo has
been modified to allow for an event by event evolution of the bulk electric
field, in three spatial dimensions. Our most resent results and interpretation
are discussed.
[6]
oai:arXiv.org:1108.6245 [pdf] - 1934624
Comparison of CDMS [100] and [111] oriented germanium detectors
Leman, S. W.;
Hertel, S. A.;
Kim, P.;
Cabrera, B.;
Silva, E. Do Couto E;
Figueroa-Feliciano, E.;
McCarthy, K. A.;
Resch, R.;
Sadoulet, B.;
Sundqvist, K. M.
Submitted: 2011-08-31
The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3" diameter
$\times$ 1" thick target masses as particle detectors. The target is
instrumented with both phonon and ionization sensors and comparison of energy
in each channel provides event-by-event classification of electron and nuclear
recoils. Fiducial volume is determined by the ability to obtain good phonon and
ionization signal at a particular location. Due to electronic band structure in
germanium, electron mass is described by an anisotropic tensor with heavy mass
aligned along the symmetry axis defined by the [111] Miller index (L valley),
resulting in large lateral component to the transport. The spatial distribution
of electrons varies significantly for detectors which have their longitudinal
axis orientations described by either the [100] or [111] Miller indices.
Electric fields with large fringing component at high detector radius also
affect the spatial distribution of electrons and holes. Both effects are
studied in a 3 dimensional Monte Carlo and the impact on fiducial volume is
discussed.
[7]
oai:arXiv.org:1012.5078 [pdf] - 371990
Search for inelastic dark matter with the CDMS II experiment
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Silva, E. do Couto e;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P.;
Dragowsky, M. R.;
Duong, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S. A.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Razeti, M.;
Reisetter, A.;
Resch, R.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Wikus, P.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2010-12-22, last modified: 2011-06-12
Results are presented from a reanalysis of the entire five-tower data set
acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the
Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis
window was extended to a recoil energy of 150 keV, and an improved
surface-event background-rejection cut was defined to increase the sensitivity
of the experiment to the inelastic dark matter (iDM) model. Three dark matter
candidates were found between 25 keV and 150 keV. The probability to observe
three or more background events in this energy range is 11%. Because of the
occurrence of these events the constraints on the iDM parameter space are
slightly less stringent than those from our previous analysis, which used an
energy window of 10-100 keV.
[8]
oai:arXiv.org:1011.2482 [pdf] - 347805
Results from a Low-Energy Analysis of the CDMS II Germanium Data
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Silva, E. do Couto e;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P.;
Dragowsky, M. R.;
Duong, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S. A.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Reisetter, A.;
Resch, R.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Wikus, P.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2010-11-10, last modified: 2011-04-21
We report results from a reanalysis of data from the Cryogenic Dark Matter
Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken
between October 2006 and September 2008 using eight germanium detectors are
reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased
sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs)
with masses below ~10 GeV/c^2. This analysis provides stronger constraints than
previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter
space associated with possible low-mass WIMP signals from the DAMA/LIBRA and
CoGeNT experiments.