Normalized to: Renault, E.
[1]
oai:arXiv.org:2003.07228 [pdf] - 2064627
Design of the HARMONI Pyramid WFS module
Schwartz, Noah;
Sauvage, Jean-François;
Renault, Edgard;
Correia, Carlos;
Neichel, Benoit;
Fusco, Thierry;
Dohlen, Kjetil;
Hadi, Kacem El;
Petit, Cyril;
Choquet, Elodie;
Chambouleyron, Vincent;
Paufique, Jerome;
Clarke, Fraser;
Thatte, Niranjan;
Bryson, Ian
Submitted: 2020-03-13
Current designs for all three extremely large telescopes show the
overwhelming adoption of the pyramid wavefront sensor (P-WFS) as the WFS of
choice for adaptive optics (AO) systems sensing on natural guide stars (NGS) or
extended objects. The key advantages of the P-WFS over the Shack-Hartmann are
known and are mainly provided by the improved sensitivity (fainter NGS) and
reduced sensitivity to spatial aliasing. However, robustness and tolerances of
the P-WFS for the ELTs are not currently well understood. In this paper, we
present simulation results for the single-conjugate AO mode of HARMONI, a
visible and near-infrared integral field spectrograph for the European
Extremely Large Telescope. We first explore the wavefront sensing issues
related to the telescope itself; namely the island effect (i.e. differential
piston) and M1 segments phasing errors. We present mitigation strategies to the
island effect and their performance. We then focus on some performance
optimisation aspects of the AO design to explore the impact of the RTC latency
and the optical gain issues, which will in particular affect the high-contrast
mode of HARMONI. Finally, we investigate the influence of the quality of glass
pyramid prism itself, and of optical aberrations on the final AO performance.
By relaxing the tolerances on the fabrication of the prism, we are able to
reduce hardware costs and simplify integration. We show the importance of
calibration (i.e. updating the control matrix) to capture any displacement of
the telescope pupil and rotation of the support structure for M4. We also show
the importance of the number of pixels used for wavefront sensing to relax
tolerances of the pyramid prism. Finally, we present a detailed optical design
of the pyramid prism, central element of the P-WFS.
[2]
oai:arXiv.org:astro-ph/0606329 [pdf] - 1233815
Probing unexplored territories with MUSE: a second generation instrument
for the VLT
Bacon, R.;
Bauer, S.;
Boehm, P.;
Boudon, D.;
Brau-Nogue, S.;
Caillier, P.;
Capoani, L.;
Carollo, C. M.;
Champavert, N.;
Contini, T.;
Daguise, E.;
Dalle, D.;
Delabre, B.;
Devriendt, J.;
Dreizler, S.;
Dubois, J.;
Dupieux, M.;
Dupin, J. P.;
Emsellem, E.;
Ferruit, P.;
Franx, M.;
Gallou, G.;
Gerssen, J.;
Guiderdoni, B.;
Hahn, T.;
Hofmann, D.;
Jarno, A.;
Kelz, A.;
Koehler, C.;
Kollatschny, W.;
Kosmalski, J.;
Laurent, F.;
Lilly, S. J.;
Lizon, J.;
Loupias, M.;
Lynn, S.;
Manescau, A.;
McDermid, R. M.;
Monstein, C.;
Nicklas, H.;
Pares, L.;
Pasquini, L.;
Pecontal-Rousset, A.;
Pecontal, E.;
Pello, R.;
Petit, C.;
Picat, J. -P.;
Popow, E.;
Quirrenbach, A.;
Reiss, R.;
Renault, E.;
Roth, M.;
Schaye, J.;
Soucail, G.;
Steinmetz, M.;
Stroebele, S.;
Stuik, R.;
Weilbacher, P.;
Wozniak, H.;
de Zeeuw, P. T.
Submitted: 2006-06-13
The Multi Unit Spectroscopic Explorer (MUSE) is a second-generation VLT
panoramic integral-field spectrograph under preliminary design study. MUSE has
a field of 1x1 arcmin**2 sampled at 0.2x0.2 arcsec**2 and is assisted by the
VLT ground layer adaptive optics ESO facility using four laser guide stars. The
simultaneous spectral range is 465-930 nm, at a resolution of R~3000. MUSE
couples the discovery potential of a large imaging device to the measuring
capabilities of a high-quality spectrograph, while taking advantage of the
increased spatial resolution provided by adaptive optics. This makes MUSE a
unique and tremendously powerful instrument for discovering and characterizing
objects that lie beyond the reach of even the deepest imaging surveys. MUSE has
also a high spatial resolution mode with 7.5x7.5 arcsec**2 field of view
sampled at 25 milli-arcsec. In this mode MUSE should be able to obtain
diffraction limited data-cubes in the 600-930 nm wavelength range. Although the
MUSE design has been optimized for the study of galaxy formation and evolution,
it has a wide range of possible applications; e.g. monitoring of outer planets
atmosphere, environment of young stellar objects, super massive black holes and
active nuclei in nearby galaxies or massive spectroscopic surveys of stellar
fields in the Milky Way and nearby galaxies.