Normalized to: Reintsema, C.
[1]
oai:arXiv.org:2002.05771 [pdf] - 2080996
Particle response of antenna-coupled TES arrays: results from SPIDER and
the lab
Osherson, B.;
Filippini, J. P.;
Fu, J.;
Gramillano, R. V.;
Gualtieri, R.;
Shaw, E. C.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Dore, O.;
Fraisse, A. A.;
Gambrel, A. E.;
Gandilo, N. N.;
Gudmundsson, J. E.;
Halpern, M.;
Hartley, J.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kermish, Z. D.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
Padilla, I. L.;
Rahlin, A. S.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Weber, A. C.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2020-02-13
Future mm-wave and sub-mm space missions will employ large arrays of
multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must
contend with the high flux of cosmic rays beyond our atmosphere that induce
"glitches" in bolometer data, which posed a challenge to data analysis from the
Planck bolometers. Future instruments will face the additional challenges of
shared substrate wafers and multiplexed readout wiring. In this work we explore
the susceptibility of modern TES arrays to the cosmic ray environment of space
using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic
microwave background polarimeter, and a laboratory exposure of SPIDER flight
hardware to radioactive sources. We find manageable glitch rates and short
glitch durations, leading to minimal effect on SPIDER analysis. We constrain
energy propagation within the substrate through a study of multi-detector
coincidences, and give a preliminary look at pulse shapes in laboratory data.
[2]
oai:arXiv.org:2002.05219 [pdf] - 2065429
Characterizing the Sensitivity of 40 GHz TES Bolometers for BICEP Array
Zhang, C.;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Henderson, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
O'Brient, R.;
Palladino, S.;
Precup, N.;
Prouvé, T.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schillaci, A.;
Schmitt, B.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Germaine, T. St.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umiltà, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.
Submitted: 2020-02-12
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial
gravitational waves in the Cosmic Microwave Background polarization, which
would be direct evidence of the inflation theory. While the tensor-to-scalar
ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further
improvements on this upper limit are hindered by polarized Galactic foreground
emissions and removal of gravitational lensing polarization. The 30/40 GHz
receiver of the BICEP Array (BA) will deploy at the end of 2019 and will
constrain the synchrotron foreground with unprecedented accuracy within the BK
sky patch. We will show the design of the 30/40 GHz detectors and test results
summarizing its performance. The low optical and atmospheric loading at these
frequencies requires our TES detectors to have low saturation power in order to
be photon-noise dominated. To realize the low thermal conductivity required
from a 250 mK base temperature, we developed new bolometer leg designs. We will
present the relevant measured detector parameters: G, Tc, Rn, Psat , and
spectral bands, and noise spectra. We achieved a per bolometer NEP including
all noise components of 2.07E-17 W/sqrt(Hz), including an anticipated photon
noise level 1.54E-17 W/sqrt(Hz).
[3]
oai:arXiv.org:2002.05197 [pdf] - 2093193
Optical characterization of the Keck Array and BICEP3 CMB Polarimeters
from 2016 to 2019
Collaboration, The BICEP/Keck;
:;
Germaine, T. St;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Fliescher, S.;
Grayson, J. A.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Leitch, E. M.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Palladino, S.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schillaci, A.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tolan, J. E.;
Tucker, C.;
Turner, A. D.;
Umilta, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wong, C. L.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.;
Zhang, C.
Submitted: 2020-02-12
The BICEP/Keck experiment (BK) is a series of small-aperture refracting
telescopes observing degree-scale Cosmic Microwave Background (CMB)
polarization from the South Pole in search of a primordial $B$-mode signature.
This $B$-mode signal arises from primordial gravitational waves interacting
with the CMB, and has amplitude parametrized by the tensor-to-scalar ratio $r$.
Since 2016, BICEP3 and the Keck Array have been observing with 4800 total
antenna-coupled transition-edge sensor detectors, with frequency bands spanning
95, 150, 220, and 270 GHz. Here we present the optical performance of these
receivers from 2016 to 2019, including far-field beams measured in situ with an
improved chopped thermal source and instrument spectral response measured with
a field-deployable Fourier Transform Spectrometer. As a pair differencing
experiment, an important systematic that must be controlled is the differential
beam response between the co-located, orthogonally polarized detectors. We
generate per-detector far-field beam maps and the corresponding differential
beam mismatch that is used to estimate the temperature-to-polarization leakage
in our CMB maps and to give feedback on detector and optics fabrication. The
differential beam parameters presented here were estimated using improved
low-level beam map analysis techniques, including efficient removal of
non-Gaussian noise as well as improved spatial masking. These techniques help
minimize systematic uncertainty in the beam analysis, with the goal of
constraining the bias on $r$ induced by temperature-to-polarization leakage to
be subdominant to the statistical uncertainty. This is essential as we progress
to higher detector counts in the next generation of CMB experiments.
[4]
oai:arXiv.org:2002.05254 [pdf] - 2048106
Optical Design and Characterization of 40-GHz Detector and Module for
the BICEP Array
Soliman, A.;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Henderson, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
OBrient, R.;
Palladino, S.;
Prouve, T.;
Precup, N.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schmitt, B.;
Schwarz, R.;
Sheehy, C. D.;
Schillaci, A.;
Germaine, T. St.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umilta, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.;
Zhang, C.
Submitted: 2020-02-12
Families of cosmic inflation models predict a primordial gravitational-wave
background that imprints B-mode polarization pattern in the Cosmic Microwave
Background (CMB). High sensitivity instruments with wide frequency coverage and
well-controlled systematic errors are needed to constrain the faint B-mode
amplitude. We have developed antenna-coupled Transition Edge Sensor (TES)
arrays for high-sensitivity polarized CMB observations over a wide range of
millimeter-wave bands. BICEP Array, the latest phase of the BICEP/Keck
experiment series, is a multi-receiver experiment designed to search for
inflationary B-mode polarization to a precision $\sigma$(r) between 0.002 and
0.004 after 3 full years of observations, depending on foreground complexity
and the degree of lensing removal. We describe the electromagnetic design and
measured performance of BICEP Array low-frequency 40-GHz detector, their
packaging in focal plane modules, and optical characterization including
efficiency and beam matching between polarization pairs. We summarize the
design and simulated optical performance, including an approach to improve the
optical efficiency due to mismatch losses. We report the measured beam maps for
a new broad-band corrugation design to minimize beam differential ellipticity
between polarization pairs caused by interactions with the module housing
frame, which helps minimize polarized beam mismatch that converts CMB
temperature to polarization ($T \rightarrow P$) anisotropy in CMB maps.
[5]
oai:arXiv.org:2002.05228 [pdf] - 2048104
Design and performance of the first BICEP Array receiver
Schillaci, A.;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Henderson, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
O'Brient, R.;
Palladino, S.;
Precup, N.;
Prouvé, T.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schmitt, B.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Germaine, T. St.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umiltà, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.;
Zhang, C.
Submitted: 2020-02-12
Branches of cosmic inflationary models, such as slow-roll inflation, predict
a background of primordial gravitational waves that imprints a unique
odd-parity B-mode pattern in the Cosmic Microwave Background (CMB) at
amplitudes that are within experimental reach. The BICEP/Keck (BK) experiment
targets this primordial signature, the amplitude of which is parameterized by
the tensor-to-scalar ratio r, by observing the polarized microwave sky through
the exceptionally clean and stable atmosphere at the South Pole. B-mode
measurements require an instrument with exquisite sensitivity, tight control of
systematics, and wide frequency coverage to disentangle the primordial signal
from the Galactic foregrounds. BICEP Array represents the most recent stage of
the BK program, and comprises four BICEP3-class receivers observing at 30/40,
95, 150 and 220/270 GHz. The 30/40 GHz receiver will be deployed at the South
Pole during the 2019/2020 austral summer. After 3 full years of observations
with 30,000+ detectors, BICEP Array will measure primordial gravitational waves
to a precision $\sigma(r)$ between 0.002 and 0.004, depending on foreground
complexity and the degree of lensing removal. In this paper we give an overview
of the instrument, highlighting the design features in terms of cryogenics,
magnetic shielding, detectors and readout architecture as well as reporting on
the integration and tests that are ongoing with the first receiver at 30/40
GHz.
[6]
oai:arXiv.org:1908.09010 [pdf] - 2040682
Micro-X Sounding Rocket: Transitioning from First Flight to a Dark
Matter Configuration
Adams, J. S.;
Anderson, A. J.;
Baker, R.;
Bandler, S. R.;
Bastidon, N.;
Castro, D.;
Danowski, M. E.;
Doriese, W. B.;
Eckart, M. E.;
Figueroa-Feliciano, E.;
Goldfinger, D. C.;
Heine, S. N. T.;
Hilton, G. C.;
Hubbard, A. J. F.;
Kelley, R. L.;
Kilbourne, C. A.;
Manzagol-Harwood, R. E.;
McCammon, D.;
Okajima, T.;
Porter, F. S.;
Reintsema, C. D.;
Serlemitsos, P.;
Smith, S. J.;
Wikus, P.
Submitted: 2019-08-22, last modified: 2020-01-30
The Micro-X sounding rocket flew for the first time on July 22, 2018,
becoming the first program to fly Transition-Edge Sensors and multiplexing
SQUID readout electronics in space. While a rocket pointing failure led to no
time on-target, the success of the flight systems was demonstrated. The
successful flight operation of the instrument puts the program in a position to
modify the payload for indirect galactic dark matter searches. The payload
modifications are motivated by the science requirements of this observation.
Micro-X can achieve world-leading sensitivity in the keV regime with a single
flight. Dark matter sensitivity projections have been updated to include recent
observations and the expected sensitivity of Micro-X to these observed fluxes.
If a signal is seen (as seen in the X-ray satellites), Micro-X can
differentiate an atomic line from a dark matter signature.
[7]
oai:arXiv.org:1909.01305 [pdf] - 2034407
Microwave multiplexing on the Keck Array
Cukierman, Ari;
Ahmed, Zeeshan;
Henderson, Shawn;
Young, Edward;
Yu, Cyndia;
Barkats, Denis;
Brown, David;
Chaudhuri, Saptarshi;
Cornelison, James;
D'Ewart, John M.;
Dierickx, Marion;
Dober, Bradley J.;
Dusatko, John;
Fatigoni, Sofia;
Filippini, Jeff P.;
Frisch, Josef C.;
Haller, Gunther;
Halpern, Mark;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Karkare, Kirit S.;
Karpel, Ethan;
Kernasovskiy, Sarah A.;
Kovac, John M.;
Kovacs, Attila;
Kuenstner, Stephen E.;
Kuo, Chao-Lin;
Li, Dale;
Mates, John A. B.;
Smith, Stephen;
Germaine, Tyler St.;
Ullom, Joel N.;
Vale, Leila R.;
Van Winkle, Daniel D.;
Vasquez, Jesus;
Willmert, Justin;
Zeng, Lingzhen;
Ade, P. A. R.;
Amiri, M.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Crumrine, M.;
Duband, L.;
Hall, G.;
Harrison, S.;
Hildebrandt, S. R.;
Hui, H.;
Kang, J.;
Kefeli, S.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
O'Brient, R.;
Palladino, S.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schillaci, A.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umilta, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Wu, W. L. K.;
Yang, H.;
Yoon, K. W.;
Zhang, C.
Submitted: 2019-09-03, last modified: 2020-01-17
We describe an on-sky demonstration of a microwave-multiplexing readout
system in one of the receivers of the Keck Array, a polarimetry experiment
observing the cosmic microwave background at the South Pole. During the austral
summer of 2018-2019, we replaced the time-division multiplexing readout system
with microwave-multiplexing components including superconducting microwave
resonators coupled to radio-frequency superconducting quantum interference
devices at the sub-Kelvin focal plane, coaxial-cable plumbing and amplification
between room temperature and the cold stages, and a SLAC Microresonator Radio
Frequency system for the warm electronics. In the range 5-6 GHz, a single
coaxial cable reads out 528 channels. The readout system is coupled to
transition-edge sensors, which are in turn coupled to 150-GHz slot-dipole
phased-array antennas. Observations began in April 2019, and we report here on
an initial characterization of the system performance.
[8]
oai:arXiv.org:1908.00480 [pdf] - 2032814
The CLASS 150/220 GHz Polarimeter Array: Design, Assembly, and
Characterization
Dahal, Sumit;
Amiri, Mandana;
Appel, John W.;
Bennett, Charles L.;
Corbett, Lance;
Datta, Rahul;
Denis, Kevin;
Essinger-Hileman, Thomas;
Halpern, Mark;
Helson, Kyle;
Hilton, Gene;
Hubmayr, Johannes;
Keller, Benjamin;
Marriage, Tobias;
Nunez, Carolina;
Petroff, Matthew;
Reintsema, Carl;
Rostem, Karwan;
U-Yen, Kongpop;
Wollack, Edward
Submitted: 2019-08-01, last modified: 2020-01-16
We report on the development of a polarization-sensitive dichroic (150/220
GHz) detector array for the Cosmology Large Angular Scale Surveyor (CLASS)
delivered to the telescope site in June 2019. In concert with existing 40 and
90 GHz telescopes, the 150/220 GHz telescope will make observations of the
cosmic microwave background over large angular scales aimed at measuring the
primordial B-mode signal, the optical depth to reionization, and other
fundamental physics and cosmology. The 150/220 GHz focal plane array consists
of three detector modules with 1020 transition edge sensor (TES) bolometers in
total. Each dual-polarization pixel on the focal plane contains four bolometers
to measure the two linear polarization states at 150 and 220 GHz. Light is
coupled through a planar orthomode transducer (OMT) fed by a smooth-walled
feedhorn array made from an aluminum-silicon alloy (CE7). In this work, we
discuss the design, assembly, and in-lab characterization of the 150/220 GHz
detector array. The detectors are photon-noise limited, and we estimate the
total array noise-equivalent power (NEP) to be 2.5 and 4 aW$\sqrt{\mathrm{s}}$
for 150 and 220 GHz arrays, respectively.
[9]
oai:arXiv.org:1908.09689 [pdf] - 2022786
First Operation of TES Microcalorimeters in Space with the Micro-X
Sounding Rocket
Adams, J. S.;
Baker, R.;
Bandler, S. R.;
Bastidon, N.;
Danowski, M. E.;
Doriese, W. B.;
Eckart, M. E.;
Figueroa-Feliciano, E.;
Goldfinger, D. C.;
Heine, S. N. T.;
Hilton, G. C.;
Hubbard, A. J. F.;
Kelley, R. L.;
Kilbourne, C. A.;
Manzagol-Harwood, R. E.;
McCammon, D.;
Okajima, T.;
Porter, F. S.;
Reintsema, C. D.;
Serlemitsos, P.;
Smith, S. J.;
Ullom, J. N.;
Wikus, P.
Submitted: 2019-08-26, last modified: 2020-01-05
Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter
array to perform high-resolution X-ray spectroscopy. This instrument flew for
the first time on July 22nd, 2018 from the White Sands Missile Range, USA. This
flight marks the first successful operation of a Transition-Edge Sensor array
and its time division multiplexing read-out system in space. This launch was
dedicated to the observation of the supernova remnant Cassiopeia A. A failure
in the attitude control system prevented the rocket from pointing and led to no
time on target. The on-board calibration source provided X-rays in flight, and
it is used to compare detector performance during pre-flight integration,
flight, and after the successful post-flight recovery. This calibration data
demonstrates the capabilities of the detector in a space environment as well as
its potential for future flights.
[10]
oai:arXiv.org:1912.02902 [pdf] - 2065335
Characterization of aliased noise in the Advanced ACTPol receiver
Gallardo, Patricio A.;
Niemack, Michael D.;
Austermann, Jason E.;
Beall, James A.;
Cothard, Nick F.;
Duell, Cody J.;
Duff, Shannon M.;
Henderson, Shawn W.;
Hilton, Gene C.;
Ho, Shuay-Pwu Patty;
Hubmayr, Johannes;
Reintsema, Carl D.;
Salatino, Maria;
Ullom, Joel;
Van Lanen, Jeff;
Vissers, Michael;
Wollack, Edward J.
Submitted: 2019-12-05
Advanced ACTPol is the second generation polarization-sensitive upgrade to
the $6\, \rm m$ aperture Atacama Cosmology Telescope (ACT), which increased
detector count and frequency coverage compared to the previous ACTPol receiver.
Advanced ACTPol utilizes a new two-stage time-division multiplexing readout
architecture based on superconducting quantum interference devices (SQUIDs) to
achieve a multiplexing factor as high as 64 (rows), fielding a 2,012 detector
camera at 150/220 GHz and two 90/150 GHz cameras containing 1,716 detectors
each. In a time domain system, aliasing introduces noise to the readout. In
this work we present a figure of merit to measure this noise contribution and
present measurements of the aliased noise fraction of the Advanced ACTPol
receiver as deployed.
[11]
oai:arXiv.org:1811.08287 [pdf] - 1880999
On-sky performance of the CLASS Q-band telescope
Appel, John W.;
Xu, Zhilei;
Padilla, Ivan L.;
Harrington, Kathleen;
Marquez, Bastián Pradenas;
Ali, Aamir;
Bennett, Charles L.;
Brewer, Michael K.;
Bustos, Ricardo;
Chan, Manwei;
Chuss, David T.;
Cleary, Joseph;
Couto, Jullianna;
Dahal, Sumit;
Denis, Kevin;
Dünner, Rolando;
Eimer, Joseph R.;
Essinger-Hileman, Thomas;
Fluxa, Pedro;
Gothe, Dominik;
Hilton, Gene C.;
Hubmayr, Johannes;
Iuliano, Jeffrey;
Karakla, John;
Marriage, Tobias A.;
Miller, Nathan J.;
Núñez, Carolina;
Parker, Lucas;
Petroff, Matthew;
Reintsema, Carl D.;
Rostem, Karwan;
Stevens, Robert W.;
Valle, Deniz Augusto Nunes;
Wang, Bingjie;
Watts, Duncan J.;
Wollack, Edward J.;
Zeng, Lingzhen
Submitted: 2018-11-19, last modified: 2019-05-10
The Cosmology Large Angular Scale Surveyor (CLASS) is mapping the
polarization of the Cosmic Microwave Background (CMB) at large angular scales
($2<\ell\lesssim200$) in search of a primordial gravitational wave B-mode
signal down to a tensor-to-scalar ratio of $r \approx 0.01$. The same data set
will provide a near sample-variance-limited measurement of the optical depth to
reionization. Between June 2016 and March 2018, CLASS completed the largest
ground-based Q-band CMB survey to date, covering over 31 000~square-degrees
(75% of the sky), with an instantaneous array noise-equivalent temperature
(NET) sensitivity of $32~\mu \mbox{K}_{cmb}\sqrt{\mbox{s}}$. We demonstrate
that the detector optical loading ($1.6~\mbox{pW}$) and noise-equivalent power
($19~\mbox{aW}\sqrt{\mbox{s}}$) match the expected noise model dominated by
photon bunching noise. We derive a $13.1\pm0.3~\mbox{K/pW}$ calibration to
antenna temperature based on Moon observations, which translates to an optical
efficiency of $0.48\pm0.04$ and a $27~\mbox{K}$ system noise temperature.
Finally, we report a Tau A flux density of $308\pm11~\mbox{Jy}$ at
$38.4\pm0.2~\mbox{GHz}$, consistent with the WMAP Tau A time-dependent spectral
flux density model.
[12]
oai:arXiv.org:1809.03689 [pdf] - 1748092
Highly-multiplexed microwave SQUID readout using the SLAC Microresonator
Radio Frequency (SMuRF) Electronics for Future CMB and Sub-millimeter Surveys
Henderson, Shawn W.;
Ahmed, Zeeshan;
Austermann, Jason;
Becker, Daniel;
Bennett, Douglas A.;
Brown, David;
Chaudhuri, Saptarshi;
Cho, Hsiao-Mei Sherry;
D'Ewart, John M.;
Dober, Bradley;
Duff, Shannon M.;
Dusatko, John E.;
Fatigoni, Sofia;
Frisch, Josef C.;
Gard, Jonathon D.;
Halpern, Mark;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Karpel, Ethan D.;
Kernasovskiy, Sarah S.;
Kuenstner, Stephen E.;
Kuo, Chao-Lin;
Li, Dale;
Mates, John A. B.;
Reintsema, Carl D.;
Smith, Stephen R.;
Ullom, Joel;
Vale, Leila R.;
Van Winkle, Daniel D.;
Vissers, Michael;
Yu, Cyndia
Submitted: 2018-09-11
The next generation of cryogenic CMB and submillimeter cameras under
development require densely instrumented sensor arrays to meet their science
goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of
sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will
require substantial improvements in cold and warm readout techniques. To reduce
the readout cost per sensor and integration complexity, efforts are presently
focused on achieving higher multiplexing density while maintaining readout
noise subdominant to intrinsic detector noise. Highly-multiplexed cold readout
technologies in active development include Microwave Kinetic Inductance Sensors
(MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of
superconducting microwave resonators to densely channelize sub-Kelvin sensors
into the bandwidth of a microwave transmission line. We present advancements in
the development of a new warm readout system for microwave SQUID multiplexing,
the SLAC Superconducting Microresonator RF electronics, or SMuRF. The SMuRF
system is unique in its ability to track each tone, minimizing the total RF
power required to read out each resonator, thereby significantly reducing the
linearity requirements on the cold and warm readout. Here, we present
measurements of the readout noise and linearity of the first full SMuRF system,
including a demonstration of closed-loop tone tracking on a 528 channel
cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential
readout solution for several future CMB projects including Simons Observatory,
BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. Parallel development of the
platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES
calorimeter arrays.
[13]
oai:arXiv.org:1803.01018 [pdf] - 1783724
The EBEX Balloon Borne Experiment - Detectors and Readout
The EBEX Collaboration;
Abitbol, Maximilian;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Feeney, Stephen M.;
Geach, Christopher;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Johannes;
Irwin, Kent;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Miller, Amber D.;
Milligan, Michael;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Tucker, Gregory S.;
Westbrook, Benjamin;
Young, Karl;
Zilic, Kyle
Submitted: 2018-03-02, last modified: 2018-07-30
EBEX was a long-duration balloon-borne experiment to measure the polarization
of the cosmic microwave background. The experiment had three frequency bands
centered at 150, 250, and 410 GHz and was the first to use a kilo-pixel array
of transition edge sensor (TES) bolometers aboard a balloon platform; shortly
after reaching float we operated 504, 342, and 109 TESs at each of the bands,
respectively. We describe the design and characterization of the array and the
readout system. We give the distributions of measured thermal conductances,
normal resistances, and transition temperatures. With the exception of the
thermal conductance at 150 GHz. We measured median low-loop-gain time constants
$\tau_{0}=$ 88, 46, and 57 ms and compare them to predictions. Two measurements
of bolometer absorption efficiency show high ($\sim$0.9) efficiency at 150 GHz
and medium ($\sim$0.35, and $\sim$0.25) at the two higher bands, respectively.
We measure a median total optical load of 3.6, 5.3 and 5.0 pW absorbed at the
three bands, respectively. EBEX pioneered the use of the digital version of the
frequency domain multiplexing (FDM) system which multiplexed the bias and
readout of 16 bolometers onto two wires. We present accounting of the measured
noise equivalent power. The median per-detector noise equivalent temperatures
referred to a black body with a temperature of 2.725 K are 400, 920, and 14500
$\mu$K$\sqrt{s}$ for the three bands, respectively. We compare these values to
our pre-flight predictions and to a previous balloon payload, discuss the
sources of excess noise, and the path for a future payload to make full use of
the balloon environment.
[14]
oai:arXiv.org:1807.04167 [pdf] - 1721214
The Cosmology Large Angular Scale Surveyor Receiver Design
Iuliano, Jeffrey;
Eimer, Joseph;
Parker, Lucas;
Rhoades, Gary;
Ali, Aamir;
Appel, John W.;
Bennett, Charles;
Brewer, Michael;
Bustos, Ricardo;
Chuss, David;
Cleary, Joseph;
Couto, Jullianna;
Dahal, Sumit;
Denis, Kevin;
Dünner, Rolando;
Essinger-Hileman, Thomas;
Fluxa, Pedro;
Halpern, Mark;
Harrington, Kathleen;
Helson, Kyle;
Hilton, Gene;
Hinshaw, Gary;
Hubmayr, Johannes;
Karakla, John;
Marriage, Tobias;
Miller, Nathan;
McMahon, Jeffrey John;
Nuñez, Carolina;
Padilla, Ivan;
Palma, Gonzalo;
Petroff, Matthew;
Márquez, Bastian Pradenas;
Reeves, Rodrigo;
Reintsema, Carl;
Rostem, Karwan;
Valle, Deniz Augusto Nunes;
Van Engelhoven, Trevor;
Wang, Bingjie;
Wang, Qinan;
Watts, Duncan;
Weiland, Jenet;
Wollack, Edward J.;
Xu, Zhilei;
Yan, Ziang;
Zeng, Lingzhen
Submitted: 2018-07-11, last modified: 2018-07-23
The Cosmology Large Angular Scale Surveyor consists of four instruments
performing a CMB polarization survey. Currently, the 40 GHz and first 90 GHz
instruments are deployed and observing, with the second 90 GHz and a
multichroic 150/220 GHz instrument to follow. The receiver is a central
component of each instrument's design and functionality. This paper describes
the CLASS receiver design, using the first 90 GHz receiver as a primary
reference. Cryogenic cooling and filters maintain a cold, low-noise environment
for the detectors. We have achieved receiver detector temperatures below 50 mK
in the 40 GHz instrument for 85% of the initial 1.5 years of operation, and
observed in-band efficiency that is consistent with pre-deployment estimates.
At 90 GHz, less than 26% of in-band power is lost to the filters and lenses in
the receiver, allowing for high optical efficiency. We discuss the mounting
scheme for the filters and lenses, the alignment of the cold optics and
detectors, stray light control, and magnetic shielding.
[15]
oai:arXiv.org:1807.03807 [pdf] - 1714380
Variable-delay Polarization Modulators for the CLASS Telescopes
Harrington, Kathleen;
Eimer, Joseph;
Chuss, David T.;
Petroff, Matthew;
Cleary, Joseph;
DeGeorge, Martin;
Grunberg, Theodore W.;
Ali, Aamir;
Appel, John W.;
Bennett, Charles L.;
Brewer, Michael;
Bustos, Ricardo;
Chan, Manwei;
Couto, Jullianna;
Dahal, Sumit;
Denis, Kevin;
Dünner, Rolando;
Essinger-Hileman, Thomas;
Fluxa, Pedro;
Halpern, Mark;
Hilton, Gene;
Hinshaw, Gary F.;
Hubmayr, Johannes;
Iuliano, Jeffrey;
Karakla, John;
Marriage, Tobias;
McMahon, Jeffrey;
Miller, Nathan J.;
Nuñez, Carolina;
Padilla, Ivan L.;
Palma, Gonzalo;
Parker, Lucas;
Marquez, Bastian Pradenas;
Reeves, Rodrigo;
Reintsema, Carl;
Rostem, Karwan;
Valle, Deniz Augusto Nunes;
Van Engelhoven, Trevor;
Wang, Bingjie;
Wang, Qinan;
Watts, Duncan;
Weiland, Janet;
Wollack, Edward;
Xu, Zhilei;
Yan, Ziang;
Zeng, Lingzhen
Submitted: 2018-07-10
The search for inflationary primordial gravitational waves and the
measurement of the optical depth to reionization, both through their imprint on
the large angular scale correlations in the polarization of the cosmic
microwave background (CMB), has created the need for high sensitivity
measurements of polarization across large fractions of the sky at millimeter
wavelengths. These measurements are subject to instrumental and atmospheric
$1/f$ noise, which has motivated the development of polarization modulators to
facilitate the rejection of these large systematic effects.
Variable-delay polarization modulators (VPMs) are used in the Cosmology Large
Angular Scale Surveyor (CLASS) telescopes as the first element in the optical
chain to rapidly modulate the incoming polarization. VPMs consist of a linearly
polarizing wire grid in front of a movable flat mirror. Varying the distance
between the grid and the mirror produces a changing phase shift between
polarization states parallel and perpendicular to the grid which modulates
Stokes U (linear polarization at $45^\circ$) and Stokes V (circular
polarization). The CLASS telescopes have VPMs as the first optical element from
the sky; this simultaneously allows a lock-in style polarization measurement
and the separation of sky polarization from any instrumental polarization
further along in the optical path. The Q-band CLASS VPM was the first VPM to
begin observing the CMB full time, starting in the Spring of 2016. The first
W-band CLASS VPM was installed in the Spring of 2018.
[16]
oai:arXiv.org:1807.03927 [pdf] - 1714397
Design and characterization of the Cosmology Large Angular Scale
Surveyor (CLASS) 93 GHz focal plane
Dahal, Sumit;
Ali, Aamir;
Appel, John W.;
Essinger-Hileman, Thomas;
Bennett, Charles;
Brewer, Michael;
Bustos, Ricardo;
Chan, Manwei;
Chuss, David T.;
Cleary, Joseph;
Colazo, Felipe;
Couto, Jullianna;
Denis, Kevin;
Dünner, Rolando;
Eimer, Joseph;
Engelhoven, Trevor;
Fluxa, Pedro;
Halpern, Mark;
Harrington, Kathleen;
Helson, Kyle;
Hilton, Gene;
Hinshaw, Gary;
Hubmayr, Johannes;
Iuliano, Jeffrey;
Marriage, Tobias;
McMahon, Jeffrey;
Miller, Nathan;
Nuñez, Carolina;
Padilla, Ivan;
Palma, Gonzalo;
Parker, Lucas;
Petroff, Matthew;
Pradenas, Bastian;
Reeves, Rodrigo;
Reintsema, Carl;
Rostem, Karwan;
Sagliocca, Marco;
U-Yen, Kongpop;
Valle, Deniz;
Wang, Bingjie;
Wang, Qinan;
Watts, Duncan;
Weiland, Janet;
Wollack, Edward;
Xu, Zhilei;
Yan, Ziang;
Zen, Lingzhen
Submitted: 2018-07-10
The Cosmology Large Angular Scale Surveyor (CLASS) aims to detect and
characterize the primordial B-mode signal and make a sample-variance-limited
measurement of the optical depth to reionization. CLASS is a ground-based,
multi-frequency microwave polarimeter that surveys 70% of the microwave sky
every day from the Atacama Desert. The focal plane detector arrays of all CLASS
telescopes contain smooth-walled feedhorns that couple to transition-edge
sensor (TES) bolometers through symmetric planar orthomode transducer (OMT)
antennas. These low noise polarization-sensitive detector arrays are fabricated
on mono-crystalline silicon wafers to maintain TES uniformity and optimize
optical efficiency throughout the wafer. In this paper, we discuss the design
and characterization of the first CLASS 93 GHz detector array. We measure the
dark parameters, bandpass, and noise spectra of the detectors and report that
the detectors are photon-noise limited. With current array yield of 82%, we
estimate the total array noise-equivalent power (NEP) to be 2.1
aW$\sqrt[]{\mathrm{s}}$.
[17]
oai:arXiv.org:1710.08456 [pdf] - 1684058
Magnetic Sensitivity of AlMn TESes and Shielding Considerations for
Next-Generation CMB Surveys
Vavagiakis, E. M.;
Henderson, S. W.;
Zheng, K.;
Cho, H. -M.;
Cothard, N. F.;
Dober, B.;
Duff, S. M.;
Gallardo, P. A.;
Hilton, G.;
Hubmayr, J.;
Irwin, K. D.;
Koopman, B. J.;
Li, D.;
Nati, F.;
Niemack, M. D.;
Reintsema, C. D.;
Simon, S.;
Stevens, J. R.;
Suzuki, A.;
Westbrook, B.
Submitted: 2017-10-23, last modified: 2018-05-16
In the next decade, new ground-based Cosmic Microwave Background (CMB)
experiments such as Simons Observatory (SO), CCAT-prime, and CMB-S4 will
increase the number of detectors observing the CMB by an order of magnitude or
more, dramatically improving our understanding of cosmology and astrophysics.
These projects will deploy receivers with as many as hundreds of thousands of
transition edge sensor (TES) bolometers coupled to Superconducting Quantum
Interference Device (SQUID)-based readout systems. It is well known that
superconducting devices such as TESes and SQUIDs are sensitive to magnetic
fields. However, the effects of magnetic fields on TESes are not easily
predicted due to the complex behavior of the superconducting transition, which
motivates direct measurements of the magnetic sensitivity of these devices. We
present comparative four-lead measurements of the critical temperature versus
applied magnetic field of AlMn TESes varying in geometry, doping, and leg
length, including Advanced ACT (AdvACT) and POLARBEAR-2/Simons Array
bolometers. Molybdenum-copper bilayer ACTPol TESes are also tested and are
found to be more sensitive to magnetic fields than the AlMn devices. We present
an observation of weak-link-like behavior in AlMn TESes at low critical
currents. We also compare measurements of magnetic sensitivity for time
division multiplexing SQUIDs and frequency division multiplexing microwave
rf-SQUIDs. We discuss the implications of our measurements on the magnetic
shielding required for future experiments that aim to map the CMB to
near-fundamental limits.
[18]
oai:arXiv.org:1801.01218 [pdf] - 1751739
Results from the Atacama B-mode Search (ABS) Experiment
Kusaka, Akito;
Appel, John;
Essinger-Hileman, Thomas;
Beall, James A.;
Campusano, Luis E.;
Cho, Hsiao-Mei;
Choi, Steve K.;
Crowley, Kevin;
Fowler, Joseph W.;
Gallardo, Patricio;
Hasselfield, Matthew;
Hilton, Gene;
Ho, Shuay-Pwu P.;
Irwin, Kent;
Jarosik, Norman;
Niemack, Michael D.;
Nixon, Glen W.;
Nolta, Michael;
Page, Lyman A.;
Palma, Gonzalo A.;
Parker, Lucas;
Raghunathan, Srinivasan;
Reintsema, Carl D.;
Sievers, Jonathan;
Simon, Sara M.;
Staggs, Suzanne T.;
Visnjic, Katerina;
Yoon, Ki-Won
Submitted: 2018-01-03
The Atacama B-mode Search (ABS) is an experiment designed to measure cosmic
microwave background (CMB) polarization at large angular scales ($\ell>40$). It
operated from the ACT site at 5190~m elevation in northern Chile at 145 GHz
with a net sensitivity (NEQ) of 41 $\mu$K$\sqrt{\rm s}$. It employed an
ambient-temperature sapphire half-wave plate rotating at 2.55 Hz to modulate
the incident polarization signal and reduce systematic effects. We report here
on the analysis of data from a 2400 deg$^2$ patch of sky centered at
declination $-42^\circ$ and right ascension $25^\circ$. We perform a blind
analysis. After unblinding, we find agreement with the Planck TE and EE
measurements on the same region of sky. We marginally detect polarized dust
emission and give an upper limit on the tensor-to-scalar ratio of $r<2.3$ (95%
cl) with the equivalent of 100 on-sky days of observation. We also present a
new measurement of the polarization of Tau A and introduce new methods
associated with HWP-based observations.
[19]
oai:arXiv.org:1710.04326 [pdf] - 1604980
Microwave SQUID Multiplexer demonstration for Cosmic Microwave
Background Imagers
Dober, B.;
Becker, D. T.;
Bennett, D. A.;
Bryan, S. A.;
Duff, S. M.;
Gard, J. D.;
Hays-Wehle, J. P.;
Hilton, G. C.;
Hubmayr, J.;
Mates, J. A. B.;
Reintsema, C. D.;
Vale, L. R.;
Ullom, J. N.
Submitted: 2017-10-11, last modified: 2017-12-15
Key performance characteristics are demonstrated for the microwave SQUID
multiplexer ($\mu$MUX) coupled to transition edge sensor (TES) bolometers that
have been optimized for cosmic microwave background (CMB) observations. In a
64-channel demonstration, we show that the $\mu$MUX produces a white, input
referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave
probe tone power, which is well below expected fundamental detector and photon
noise sources for a ground-based CMB-optimized bolometer. Operated with
negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the
TES-coupled channels biased at 65% of the sensor normal resistance. This noise
level is consistent with that predicted from bolometer thermal fluctuation
(i.e., phonon) noise. Furthermore, the power spectral density exhibits a white
spectrum at low frequencies ($\sim$~100~mHz), which enables CMB mapping on
large angular scales that constrain the physics of inflation. Additionally, we
report cross-talk measurements that indicate a level below 0.3%, which is less
than the level of cross-talk from multiplexed readout systems in deployed CMB
imagers. These measurements demonstrate the $\mu$MUX as a viable readout
technique for future CMB imaging instruments.
[20]
oai:arXiv.org:1711.10596 [pdf] - 1783704
SPIDER: CMB polarimetry from the edge of space
Gualtieri, R.;
Filippini, J. P.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bergman, A. S.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Doré, O.;
Duivenvoorden, A. J.;
Eriksen, H. K.;
Farhang, M.;
Fissel, L. M.;
Fraisse, A. A.;
Freese, K.;
Galloway, M.;
Gambrel, A. E.;
Gandilo, N. N.;
Ganga, K.;
Gramillano, R. V.;
Gudmundsson, J. E.;
Halpern, M.;
Hartley, J.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Huang, Z.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
Kermish, Z. D.;
Li, S.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
Nolta, M.;
Osherson, B.;
Padilla, I. L.;
Racine, B.;
Rahlin, A. S.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Ruud, T. M.;
Shariff, J. A.;
Soler, J. D.;
Song, X.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
van der List, J. F.;
Weber, A. C.;
Wehus, I. K.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2017-11-28
SPIDER is a balloon-borne instrument designed to map the polarization of the
millimeter-wave sky at large angular scales. SPIDER targets the B-mode
signature of primordial gravitational waves in the cosmic microwave background
(CMB), with a focus on mapping a large sky area with high fidelity at multiple
frequencies. SPIDER's first longduration balloon (LDB) flight in January 2015
deployed a total of 2400 antenna-coupled Transition Edge Sensors (TESs) at 90
GHz and 150 GHz. In this work we review the design and in-flight performance of
the SPIDER instrument, with a particular focus on the measured performance of
the detectors and instrument in a space-like loading and radiation environment.
SPIDER's second flight in December 2018 will incorporate payload upgrades and
new receivers to map the sky at 285 GHz, providing valuable information for
cleaning polarized dust emission from CMB maps.
[21]
oai:arXiv.org:1711.04169 [pdf] - 1755845
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2
Suborbital Polarimeter
Bergman, A. S.;
Ade, P. A. R.;
Akers, S.;
Amiri, M.;
Austermann, J. A.;
Beall, J. A.;
Becker, D. T.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Domagalski, R. S;
Doré, O.;
Duff, S. M.;
Duivenvoorden, A. J.;
Eriksen, H. K.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Freese, K.;
Galloway, M.;
Gambrel, A. E.;
Gandilo, N. N.;
Ganga, K.;
Grigorian, A.;
Gualtieri, R.;
Gudmundsson, J. E.;
Halpern, M.;
Hartley, J.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Huang, Z.;
Hubmayr, J.;
Irwin, K. D.;
Jones, W. C.;
Khan, A.;
Kuo, C. L.;
Kermish, Z. D.;
Li, S.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
Nolta, M.;
Osherson, B.;
Padilla, I. L.;
Racine, B.;
Rahlin, A. S.;
Redmond, S.;
Reintsema, C.;
Romualdez, L. J.;
Ruhl, J. E.;
Runyan, M. C.;
Ruud, T. M.;
Shariff, J. A.;
Shaw, E. C.;
Shiu, C.;
Soler, J. D.;
Song, X.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Ullom, J.;
van der List, J. F.;
Van Lanen, J.;
Vissers, M. R.;
Weber, A. C.;
Wehus, I. K.;
Wen, S.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2017-11-11, last modified: 2017-11-22
We describe the construction and characterization of the 280 GHz bolometric
focal plane units (FPUs) to be deployed on the second flight of the
balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary
science goal of detecting or placing an upper limit on the amplitude of the
primordial gravitational wave signature in the cosmic microwave background
(CMB) by constraining the B-mode contamination in the CMB from Galactic dust
emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated
silicon feedhorns coupled to an array of aluminum-manganese transition-edge
sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the
three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial
pixels) optimized for the low loading environment in flight and read out by
time-division SQUID multiplexing. In this paper we describe the mechanical,
thermal, and magnetic shielding architecture of the focal planes and present
cryogenic measurements which characterize yield and the uniformity of several
bolometer parameters. The assembled FPUs have high yields, with one array as
high as 95% including defects from wiring and readout. We demonstrate high
uniformity in device parameters, finding the median saturation power for each
TES array to be ~3 pW at 300 mK with a less than 6% variation across each array
at one standard deviation. These focal planes will be deployed alongside the 95
and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo
Station in Antarctica in December 2018.
[22]
oai:arXiv.org:1704.00215 [pdf] - 1582291
A New Limit on CMB Circular Polarization from SPIDER
Nagy, J. M.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bergman, A. S.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Dore, O.;
Duivenvoorden, A. J.;
Eriksen, H. K.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Freese, K.;
Galloway, M.;
Gambrel, A. E.;
Gandilo, N. N.;
Ganga, K.;
Gudmundsson, J. E.;
Halpern, M.;
Hartley, J.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Huang, Z.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
Kermish, Z. D.;
Li, S.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Netterfield, C. B.;
Nolta, M.;
Padilla, I. L.;
Racine, B.;
Rahlin, A. S.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Ruud, T. M.;
Shariff, J. A.;
Soler, J. D.;
Song, X.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
van der List, J. F.;
Weber, A. C.;
Wehus, I. K.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2017-04-01, last modified: 2017-08-11
We present a new upper limit on CMB circular polarization from the 2015
flight of SPIDER, a balloon-borne telescope designed to search for $B$-mode
linear polarization from cosmic inflation. Although the level of circular
polarization in the CMB is predicted to be very small, experimental limits
provide a valuable test of the underlying models. By exploiting the non-zero
circular-to-linear polarization coupling of the HWP polarization modulators,
data from SPIDER's 2015 Antarctic flight provide a constraint on Stokes $V$ at
95 and 150 GHz from $33<\ell<307$. No other limits exist over this full range
of angular scales, and SPIDER improves upon the previous limit by several
orders of magnitude, providing 95% C.L. constraints on $\ell
(\ell+1)C_{\ell}^{VV}/(2\pi)$ ranging from 141 $\mu K ^2$ to 255 $\mu K ^2$ at
150 GHz for a thermal CMB spectrum. As linear CMB polarization experiments
become increasingly sensitive, the techniques described in this paper can be
applied to obtain even stronger constraints on circular polarization.
[23]
oai:arXiv.org:1611.07856 [pdf] - 1532790
When "Optimal Filtering" Isn't
Fowler, J. W.;
Alpert, B. K.;
Doriese, W. B.;
Hays-Wehle, J.;
Joe, Y. -I.;
Morgan, K. M.;
O'Neil, G. C.;
Reintsema, C. D.;
Schmidt, D. R.;
Ullom, J. N.;
Swetz, D. S.
Submitted: 2016-11-23
The so-called "optimal filter" analysis of a microcalorimeter's x-ray pulses
is statistically optimal only if all pulses have the same shape, regardless of
energy. The shapes of pulses from a nonlinear detector can and do depend on the
pulse energy, however. A pulse-fitting procedure that we call "tangent
filtering" accounts for the energy dependence of the shape and should therefore
achieve superior energy resolution. We take a geometric view of the
pulse-fitting problem and give expressions to predict how much the energy
resolution stands to benefit from such a procedure. We also demonstrate the
method with a case study of K-line fluorescence from several 3d transition
metals. The method improves the resolution from 4.9 eV to 4.2 eV at the Cu
K$\alpha$ line (8.0keV).
[24]
oai:arXiv.org:1607.06861 [pdf] - 1531101
BICEP3 focal plane design and detector performance
Hui, H.;
Ade, P. A. R.;
Ahmed, Z.;
Alexander, K. D.;
Amiri, M.;
Barkats, D.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bowens-Rubin, R.;
Buder, I.;
Bullock, E.;
Buza, V.;
Connors, J.;
Filippini, J. P.;
Fliescher, S.;
Grayson, J. A.;
Halpern, M.;
Harrison, S.;
Hilton, G. C.;
Hristov, V. V.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E. M.;
Lueker, M.;
Megerian, K. G.;
Monticue, V.;
Namikawa, T.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Pryke, C.;
Reintsema, C. D.;
Richter, S.;
Schwarz, R.;
Sorensen, C.;
Sheehy, C. D.;
Staniszewski, Z. K.;
Steinbach, B.;
Teply, G. P.;
Thompson, K. L.;
Tolan, J. E.;
Tucker, C.;
Turner, A. D.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yoon, K. W.
Submitted: 2016-07-22
BICEP3, the latest telescope in the BICEP/Keck program, started science
observations in March 2016. It is a 550mm aperture refractive telescope
observing the polarization of the cosmic microwave background at 95 GHz. We
show the focal plane design and detector performance, including spectral
response, optical efficiency and preliminary sensitivity of the upgraded
BICEP3. We demonstrate 9.72$\mu$K$\sqrt{\textrm{s}}$ noise performance of the
BICEP3 receiver.
[25]
oai:arXiv.org:1607.06064 [pdf] - 1531072
Readout of two-kilopixel transition-edge sensor arrays for Advanced
ACTPol
Henderson, Shawn W.;
Stevens, Jason R.;
Amiri, Mandana;
Austermann, Jason;
Beall, James A.;
Chaudhuri, Saptarshi;
Cho, Hsiao-Mei;
Choi, Steve K.;
Cothard, Nicholas F.;
Crowley, Kevin T.;
Duff, Shannon M.;
Fitzgerald, Colin P.;
Gallardo, Patricio A.;
Halpern, Mark;
Hasselfield, Matthew;
Hilton, Gene;
Ho, Shuay-Pwu Patty;
Hubmayr, Johannes;
Irwin, Kent D.;
Koopman, Brian J.;
Li, Dale;
Li, Yaqiong;
McMahon, Jeff;
Nati, Federico;
Niemack, Michael D.;
Reintsema, Carl D.;
Salatino, Maria;
Schillaci, Alessandro;
Schmitt, Benjamin L.;
Simon, Sara M.;
Staggs, Suzanne T.;
Vavagiakis, Eve M.;
Ward, Jonathan T.
Submitted: 2016-07-20
Advanced ACTPol is an instrument upgrade for the six-meter Atacama Cosmology
Telescope (ACT) designed to measure the cosmic microwave background (CMB)
temperature and polarization with arcminute-scale angular resolution. To
achieve its science goals, Advanced ACTPol utilizes a larger readout
multiplexing factor than any previous CMB experiment to measure detector arrays
with approximately two thousand transition-edge sensor (TES) bolometers in each
150 mm detector wafer. We present the implementation and testing of the
Advanced ACTPol time-division multiplexing readout architecture with a 64-row
multiplexing factor. This includes testing of individual multichroic detector
pixels and superconducting quantum interference device (SQUID) multiplexing
chips as well as testing and optimizing of the integrated readout electronics.
In particular, we describe the new automated multiplexing SQUID tuning
procedure developed to select and optimize the thousands of SQUID parameters
required to readout each Advanced ACTPol array. The multichroic detector pixels
in each array use separate channels for each polarization and each of the two
frequencies, such that four TESes must be read out per pixel. Challenges
addressed include doubling the number of detectors per multiplexed readout
channel compared to ACTPol and optimizing the Nyquist inductance to minimize
detector and SQUID noise aliasing.
[26]
oai:arXiv.org:1607.04668 [pdf] - 1531046
BICEP3 performance overview and planned Keck Array upgrade
Grayson, J. A.;
Ade, P. A. R.;
Ahmed, Z.;
Alexander, K. D.;
Amiri, M.;
Barkats, D.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bowens-Rubin, R.;
Buder, I.;
Bullock, E.;
Buza, V.;
Connors, J.;
Filippini, J. P.;
Fliescher, S.;
Halpern, M.;
Harrison, S.;
Hilton, G. C.;
Hristov, V. V.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E. M.;
Lueker, M.;
Megerian, K. G.;
Monticue, V.;
Namikawa, T.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Pryke, C.;
Reintsema, C. D.;
Richter, S.;
Schwarz, R.;
Sorensen, C.;
Sheehy, C. D.;
Staniszewski, Z. K.;
Steinbach, B.;
Teply, G. P.;
Thompson, K. L.;
Tolan, J. E.;
Tucker, C.;
Turner, A. D.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yoon, K. W.
Submitted: 2016-07-15
BICEP3 is a 520 mm aperture, compact two-lens refractor designed to observe
the polarization of the cosmic microwave background (CMB) at 95 GHz. Its focal
plane consists of modularized tiles of antenna-coupled transition edge sensors
(TESs), similar to those used in BICEP2 and the Keck Array. The increased
per-receiver optical throughput compared to BICEP2/Keck Array, due to both its
faster f/1.7 optics and the larger aperture, more than doubles the combined
mapping speed of the BICEP/Keck program. The BICEP3 receiver was recently
upgraded to a full complement of 20 tiles of detectors (2560 TESs) and is now
beginning its second year of observation (and first science season) at the
South Pole. We report on its current performance and observing plans. Given its
high per-receiver throughput while maintaining the advantages of a compact
design, BICEP3-class receivers are ideally suited as building blocks for a
3rd-generation CMB experiment, consisting of multiple receivers spanning 35 GHz
to 270 GHz with total detector count in the tens of thousands. We present plans
for such an array, the new "BICEP Array" that will replace the Keck Array at
the South Pole, including design optimization, frequency coverage, and
deployment/observing strategies.
[27]
oai:arXiv.org:1607.04567 [pdf] - 1531043
Optical Characterization of the BICEP3 CMB Polarimeter at the South Pole
Karkare, K. S.;
Ade, P. A. R.;
Ahmed, Z.;
Alexander, K. D.;
Amiri, M.;
Barkats, D.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bowens-Rubin, R.;
Buder, I.;
Bullock, E.;
Buza, V.;
Connors, J.;
Filippini, J. P.;
Fliescher, S. T.;
Grayson, J. A.;
Halpern, M.;
Harrison, S. A.;
Hilton, G. C.;
Hristov, V. V.;
Hui, H.;
Irwin, K. D.;
Kang, J. H.;
Karpel, E.;
Kefeli, S.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E. M.;
Lueker, M.;
Megerian, K. G.;
Monticue, V.;
Namikawa, T.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Pryke, C.;
Reintsema, C. D.;
Richter, S.;
Germaine, M. T. St.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z. K.;
Steinbach, B.;
Teply, G. P.;
Thompson, K. L.;
Tolan, J. E.;
Tucker, C.;
Turner, A. D.;
Vieregg, A. G.;
Wandui, A.;
Weber, A.;
Willmert, J.;
Wong, C. L.;
Wu, W. L. K.;
Yoon, K. W.
Submitted: 2016-07-15
BICEP3 is a small-aperture refracting cosmic microwave background (CMB)
telescope designed to make sensitive polarization maps in pursuit of a
potential B-mode signal from inflationary gravitational waves. It is the latest
in the BICEP/Keck Array series of CMB experiments at the South Pole, which has
provided the most stringent constraints on inflation to date. For the 2016
observing season, BICEP3 was outfitted with a full suite of 2400 optically
coupled detectors operating at 95 GHz. In these proceedings we report on the
far field beam performance using calibration data taken during the 2015-2016
summer deployment season in situ with a thermal chopped source. We generate
high-fidelity per-detector beam maps, show the array-averaged beam profile, and
characterize the differential beam response between co-located, orthogonally
polarized detectors which contributes to the leading instrumental systematic in
pair differencing experiments. We find that the levels of differential
pointing, beamwidth, and ellipticity are similar to or lower than those
measured for BICEP2 and Keck Array. The magnitude and distribution of BICEP3's
differential beam mismatch - and the level to which temperature-to-polarization
leakage may be marginalized over or subtracted in analysis - will inform the
design of next-generation CMB experiments with many thousands of detectors.
[28]
oai:arXiv.org:1601.07923 [pdf] - 1350058
Temperature calibration of the E and B experiment
Aubin, Francois;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Feeney, Stephen;
Geach, Christopher;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
Macdermid, Kevin;
Marchenko, Valerie;
Miller, Amber D.;
Milligan, Michael;
Pascale, Enzo;
Puglisi, Giuseppe;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Stompor, Radek;
Tristram, Matthieu;
Tucker, Gregory S.;
Westbrook, Ben;
Young, Karl;
Zilic, Kyle
Submitted: 2016-01-28
The E and B Experiment (EBEX) is a balloon-borne polarimeter designed to
measure the polarization of the cosmic microwave background radiation and to
characterize the polarization of galactic dust. EBEX was launched December 29,
2012 and circumnavigated Antarctica observing $\sim$6,000 square degrees of sky
during 11 days at three frequency bands centered around 150, 250 and 410 GHz.
EBEX was the first experiment to operate a kilo-pixel array of transition-edge
sensor bolometers and a continuously rotating achromatic half-wave plate aboard
a balloon platform. It also pioneered the use of detector readout based on
digital frequency domain multiplexing.
We describe the temperature calibration of the experiment. The gain response
of the experiment is calibrated using a two-step iterative process. We use
signals measured on passes across the Galactic plane to convert from
readout-system counts to power. The effective smoothing scale of the EBEX
optics and the star camera-to-detector offset angles are determined through
\c{hi}2 minimization using the compact HII region RCW 38. This two-step process
is initially performed with parameters measured before the EBEX 2013 flight and
then repeated until the calibration factor and parameters converge.
[29]
oai:arXiv.org:1510.01771 [pdf] - 1337397
A cryogenic rotation stage with a large clear aperture for the half-wave
plates in the Spider instrument
Bryan, Sean;
Ade, Peter;
Amiri, Mandana;
Benton, Steven;
Bihary, Richard;
Bock, James;
Bond, J. Richard;
Chiang, H. Cynthia;
Contaldi, Carlo;
Crill, Brendan;
Dore, Olivier;
Elder, Benjamin;
Filippini, Jeffrey;
Fraisse, Aurelien;
Gambrel, Anne;
Gandilo, Natalie;
Gudmundsson, Jon;
Hasselfield, Matthew;
Halpern, Mark;
Hilton, Gene;
Holmes, Warren;
Hristov, Viktor;
Irwin, Kent;
Jones, William;
Kermish, Zigmund;
Lawrie, Craig;
MacTavish, Carrie;
Mason, Peter;
Megerian, Krikor;
Moncelsi, Lorenzo;
Montroy, Thomas;
Morford, Tracy;
Nagy, Johanna;
Netterfield, C. Barth;
Padilla, Ivan;
Rahlin, Alexandra S.;
Reintsema, Carl;
Riley, Daniel C.;
Ruhl, John;
Runyan, Marcus;
Saliwanchik, Benjamin;
Shariff, Jamil;
Soler, Juan;
Trangsrud, Amy;
Tucker, Carole;
Tucker, Rebecca;
Turner, Anthony;
Wen, Shyang;
Wiebe, Donald;
Young, Edward
Submitted: 2015-10-06, last modified: 2016-01-08
We describe the cryogenic half-wave plate rotation mechanisms built for and
used in Spider, a polarization-sensitive balloon-borne telescope array that
observed the Cosmic Microwave Background at 95 GHz and 150 GHz during a
stratospheric balloon flight from Antarctica in January 2015. The mechanisms
operate at liquid helium temperature in flight. A three-point contact design
keeps the mechanical bearings relatively small but allows for a large (305 mm)
diameter clear aperture. A worm gear driven by a cryogenic stepper motor allows
for precise positioning and prevents undesired rotation when the motors are
depowered. A custom-built optical encoder system monitors the bearing angle to
an absolute accuracy of +/- 0.1 degrees. The system performed well in Spider
during its successful 16 day flight.
[30]
oai:arXiv.org:1601.00125 [pdf] - 1335082
Initial Performance of BICEP3: A Degree Angular Scale 95 GHz Band
Polarimeter
Wu, W. L. K.;
Ade, P. A. R.;
Ahmed, Z.;
Alexander, K. D.;
Amiri, M.;
Barkats, D.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Bowens-Rubin, R.;
Buder, I.;
Bullock, E.;
Buza, V.;
Connors, J. A.;
Filippini, J. P.;
Fliescher, S.;
Grayson, J. A.;
Halpern, M.;
Harrison, S. A.;
Hilton, G. C.;
Hristov, V. V.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Megerian, K. G.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Pryke, C.;
Reintsema, C. D.;
Richter, S.;
Sorensen, C.;
Staniszewski, Z. K.;
Steinbach, B.;
Sudiwala, R. V.;
Teply, G. P.;
Thompson, K. L.;
Tolan, J. E.;
Tucker, C. E.;
Turner, A. D.;
Vieregg, A. G.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Yoon, K. W.
Submitted: 2016-01-01
BICEP3 is a $550~mm$ aperture telescope with cold, on-axis, refractive optics
designed to observe at the $95~GHz$ band from the South Pole. It is the newest
member of the BICEP/Keck family of inflationary probes specifically designed to
measure the polarization of the cosmic microwave background (CMB) at
degree-angular scales. BICEP3 is designed to house 1280 dual-polarization
pixels, which, when fully-populated, totals to $\sim$9$\times$ the number of
pixels in a single Keck $95~GHz$ receiver, thus further advancing the
BICEP/Keck program's $95~GHz$ mapping speed. BICEP3 was deployed during the
austral summer of 2014-2015 with 9 detector tiles, to be increased to its full
capacity of 20 in the second season. After instrument characterization
measurements were taken, CMB observation commenced in April 2015. Together with
multi-frequency observation data from Planck, BICEP2, and the Keck Array,
BICEP3 is projected to set upper limits on the tensor-to-scalar ratio to $r$
$\lesssim 0.03$ at $95\%$ C.L..
[31]
oai:arXiv.org:1511.04414 [pdf] - 1449883
Cosmology Large Angular Scale Surveyor (CLASS) Focal Plane Development
Chuss, D. T.;
Ali, A.;
Amiri, M.;
Appel, J.;
Bennett, C. L.;
Colazo, F.;
Denis, K. L.;
Dünner, R.;
Essinger-Hileman, T.;
Eimer, J.;
Fluxa, P.;
Gothe, D.;
Halpern, M.;
Harrington, K.;
Hilton, G.;
Hinshaw, G.;
Hubmayr, J.;
Iuliano, J.;
Marriage, T. A.;
Miller, N.;
Moseley, S. H.;
Mumby, G.;
Petroff, M.;
Reintsema, C.;
Rostem, K.;
U-Yen, K.;
Watts, D.;
Wagner, E.;
Wollack, E. J.;
Xu, Z.;
Zeng, L.
Submitted: 2015-11-13
The Cosmology Large Angular Scale Surveyor (CLASS) will measure the
polarization of the Cosmic Microwave Background to search for and characterize
the polarized signature of inflation. CLASS will operate from the Atacama
Desert and observe $\sim$70% of the sky. A variable-delay polarization
modulator (VPM) modulates the polarization at $\sim$10 Hz to suppress the 1/f
noise of the atmosphere and enable the measurement of the large angular scale
polarization modes. The measurement of the inflationary signal across angular
scales that span both the recombination and reionization features allows a test
of the predicted shape of the polarized angular power spectra in addition to a
measurement of the energy scale of inflation.
CLASS is an array of telescopes covering frequencies of 38, 93, 148, and 217
GHz. These frequencies straddle the foreground minimum and thus allow the
extraction of foregrounds from the primordial signal. Each focal plane contains
feedhorn-coupled transition-edge sensors that simultaneously detect two
orthogonal linear polarizations. The use of single-crystal silicon as the
dielectric for the on-chip transmission lines enables both high efficiency and
uniformity in fabrication. Integrated band definition has been implemented that
both controls the bandpass of the single mode transmission on the chip and
prevents stray light from coupling to the detectors.
[32]
oai:arXiv.org:1506.06953 [pdf] - 1275488
The Thermal Design, Characterization, and Performance of the SPIDER
Long-Duration Balloon Cryostat
Gudmundsson, J. E.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Doré, O.;
Filippini, J. P.;
Fraisse, A. A.;
Gambrel, A.;
Gandilo, N. N.;
Hasselfield, M.;
Halpern, M.;
Hilton, G. C.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kermish, Z.;
MacTavish, C. J.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Montroy, T. E.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Wiebe, D. V.;
Young, E.
Submitted: 2015-06-23, last modified: 2015-09-11
We describe the SPIDER flight cryostat, which is designed to cool six
millimeter-wavelength telescopes during an Antarctic long-duration balloon
flight. The cryostat, one of the largest to have flown on a stratospheric
payload, uses liquid helium-4 to deliver cooling power to stages at 4.2 and 1.6
K. Stainless steel capillaries facilitate a high flow impedance connection
between the main liquid helium tank and a smaller superfluid tank, allowing the
latter to operate at 1.6 K as long as there is liquid in the 4.2 K main tank.
Each telescope houses a closed cycle helium-3 adsorption refrigerator that
further cools the focal planes down to 300 mK. Liquid helium vapor from the
main tank is routed through heat exchangers that cool radiation shields,
providing negative thermal feedback. The system performed successfully during a
17 day flight in the 2014-2015 Antarctic summer. The cryostat had a total hold
time of 16.8 days, with 15.9 days occurring during flight.
[33]
oai:arXiv.org:1502.00643 [pdf] - 1287468
BICEP2 / Keck Array V: Measurements of B-mode Polarization at Degree
Angular Scales and 150 GHz by the Keck Array
BICEP2, The;
Collaborations, Keck Array;
:;
Ade, P. A. R.;
Ahmed, Z.;
Aikin, R. W.;
Alexander, K. D.;
Barkats, D.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Brevik, J. A.;
Buder, I.;
Bullock, E.;
Buza, V.;
Connors, J.;
Crill, B. P.;
Dowell, C. D.;
Dvorkin, C.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hristov, V. V.;
Hui, H.;
Irwin, K. D.;
Karkare, K. S.;
Kaufman, J. P.;
Keating, B. G.;
Kefeli, S.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E. M.;
Lueker, M.;
Mason, P.;
Megerian, K. G.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Orlando, A.;
Pryke, C.;
Reintsema, C. D.;
Richter, S.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z. K.;
Sudiwala, R. V.;
Teply, G. P.;
Thompson, K. L.;
Tolan, J. E.;
Turner, A. D.;
Vieregg, A. G.;
Weber, A. C.;
Willmert, J.;
Wong, C. L.;
Yoon, K. W.
Submitted: 2015-02-02, last modified: 2015-08-31
The Keck Array is a system of cosmic microwave background (CMB) polarimeters,
each similar to the BICEP2 experiment. In this paper we report results from the
2012 and 2013 observing seasons, during which the Keck Array consisted of five
receivers all operating in the same (150 GHz) frequency band and observing
field as BICEP2. We again find an excess of B-mode power over the
lensed-$\Lambda$CDM expectation of $> 5 \sigma$ in the range $30 < \ell < 150$
and confirm that this is not due to systematics using jackknife tests and
simulations based on detailed calibration measurements. In map difference and
spectral difference tests these new data are shown to be consistent with
BICEP2. Finally, we combine the maps from the two experiments to produce final
Q and U maps which have a depth of 57 nK deg (3.4 $\mu$K arcmin) over an
effective area of 400 deg$^2$ for an equivalent survey weight of 250,000
$\mu$K$^{-2}$. The final BB band powers have noise uncertainty a factor of 2.3
times better than the previous results, and a significance of detection of
excess power of $> 6\sigma$.
[34]
oai:arXiv.org:1502.00619 [pdf] - 1300145
Antenna-coupled TES bolometers used in BICEP2, Keck array, and SPIDER
Ade, P. A. R.;
Aikin, R. W.;
Amiri, M.;
Barkats, D.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Buder, I.;
Bullock, E.;
Chattopadhyay, G.;
Davis, G.;
Day, P. K.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hristov, V.;
Hui, H.;
Irwin, K. D.;
Jones, W. C.;
Karkare, K. S.;
Kaufman, J. P.;
Keating, B. G.;
Kefeli, S.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Leduc, H. G.;
Leitch, E. M.;
Llombart, N.;
Lueker, M.;
Mason, P.;
Megerian, K.;
Moncelsi, L.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Orlando, A.;
Pryke, C.;
Rahlin, A. S.;
Reintsema, C. D.;
Richter, S.;
Runyan, M. C.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z. K.;
Sudiwala, R. V.;
Teply, G. P.;
Tolan, J. E.;
Trangsrud, A.;
Tucker, R. S.;
Turner, A. D.;
Vieregg, A. G.;
Weber, A.;
Wiebe, D. V.;
Wilson, P.;
Wong, C. L.;
Yoon, K. W.;
Zmuidzinas, J.
Submitted: 2015-02-02
We have developed antenna-coupled transition-edge sensor (TES) bolometers for
a wide range of cosmic microwave background (CMB) polarimetry experiments,
including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors
have reached maturity and this paper reports on their design principles,
overall performance, and key challenges associated with design and production.
Our detector arrays repeatedly produce spectral bands with 20%-30% bandwidth at
95, 150, or 220~GHz. The integrated antenna arrays synthesize symmetric
co-aligned beams with controlled side-lobe levels. Cross-polarized response on
boresight is typically ~0.5%, consistent with cross-talk in our multiplexed
readout system. End-to-end optical efficiencies in our cameras are routinely
35% or higher, with per detector sensitivities of NET~300 uKrts. Thanks to the
scalability of this design, we have deployed 2560 detectors as 1280 matched
pairs in Keck Array with a combined instantaneous sensitivity of ~9 uKrts, as
measured directly from CMB maps in the 2013 season. Similar arrays have
recently flown in the SPIDER instrument, and development of this technology is
ongoing.
[35]
oai:arXiv.org:1408.4788 [pdf] - 1216429
CLASS: The Cosmology Large Angular Scale Surveyor
Essinger-Hileman, Thomas;
Ali, Aamir;
Amiri, Mandana;
Appel, John W.;
Araujo, Derek;
Bennett, Charles L.;
Boone, Fletcher;
Chan, Manwei;
Cho, Hsiao-Mei;
Chuss, David T.;
Colazo, Felipe;
Crowe, Erik;
Denis, Kevin;
Dünner, Rolando;
Eimer, Joseph;
Gothe, Dominik;
Halpern, Mark;
Harrington, Kathleen;
Hilton, Gene;
Hinshaw, Gary F.;
Huang, Caroline;
Irwin, Kent;
Jones, Glenn;
Karakla, John;
Kogut, Alan J.;
Larson, David;
Limon, Michele;
Lowry, Lindsay;
Marriage, Tobias;
Mehrle, Nicholas;
Miller, Amber D.;
Miller, Nathan;
Moseley, Samuel H.;
Novak, Giles;
Reintsema, Carl;
Rostem, Karwan;
Stevenson, Thomas;
Towner, Deborah;
U-Yen, Kongpop;
Wagner, Emily;
Watts, Duncan;
Wollack, Edward;
Xu, Zhilei;
Zeng, Lingzhen
Submitted: 2014-08-20
The Cosmology Large Angular Scale Surveyor (CLASS) is an experiment to
measure the signature of a gravita-tional-wave background from inflation in the
polarization of the cosmic microwave background (CMB). CLASS is a
multi-frequency array of four telescopes operating from a high-altitude site in
the Atacama Desert in Chile. CLASS will survey 70\% of the sky in four
frequency bands centered at 38, 93, 148, and 217 GHz, which are chosen to
straddle the Galactic-foreground minimum while avoiding strong atmospheric
emission lines. This broad frequency coverage ensures that CLASS can
distinguish Galactic emission from the CMB. The sky fraction of the CLASS
survey will allow the full shape of the primordial B-mode power spectrum to be
characterized, including the signal from reionization at low $\ell$. Its unique
combination of large sky coverage, control of systematic errors, and high
sensitivity will allow CLASS to measure or place upper limits on the
tensor-to-scalar ratio at a level of $r=0.01$ and make a
cosmic-variance-limited measurement of the optical depth to the surface of last
scattering, $\tau$.
[36]
oai:arXiv.org:1403.4302 [pdf] - 862577
BICEP2 II: Experiment and Three-Year Data Set
BICEP2 Collaboration;
Ade, P. A. R;
Aikin, R. W.;
Amiri, M.;
Barkats, D.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Brevik, J. A.;
Buder, I.;
Bullock, E.;
Davis, G.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hristov, V. V.;
Irwin, K. D.;
Karkare, K. S.;
Kaufman, J. P.;
Keating, B. G.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E. M.;
Llombart, N.;
Lueker, M.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Orlando, A.;
Pryke, C.;
Reintsema, C. D.;
Richter, S.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z. K.;
Story, K. T.;
Sudiwala, R. V.;
Teply, G. P.;
Tolan, J. E.;
Turner, A. D.;
Vieregg, A. G.;
Wilson, P.;
Wong, C. L.;
Yoon, K. W.
Submitted: 2014-03-17, last modified: 2014-07-31
We report on the design and performance of the BICEP2 instrument and on its
three-year data set. BICEP2 was designed to measure the polarization of the
cosmic microwave background (CMB) on angular scales of 1 to 5 degrees
($\ell$=40-200), near the expected peak of the B-mode polarization signature of
primordial gravitational waves from cosmic inflation. Measuring B-modes
requires dramatic improvements in sensitivity combined with exquisite control
of systematics. The BICEP2 telescope observed from the South Pole with a 26~cm
aperture and cold, on-axis, refractive optics. BICEP2 also adopted a new
detector design in which beam-defining slot antenna arrays couple to
transition-edge sensor (TES) bolometers, all fabricated on a common substrate.
The antenna-coupled TES detectors supported scalable fabrication and
multiplexed readout that allowed BICEP2 to achieve a high detector count of 500
bolometers at 150 GHz, giving unprecedented sensitivity to B-modes at degree
angular scales. After optimization of detector and readout parameters, BICEP2
achieved an instrument noise-equivalent temperature of 15.8 $\mu$K sqrt(s). The
full data set reached Stokes Q and U map depths of 87.2 nK in square-degree
pixels (5.2 $\mu$K arcmin) over an effective area of 384 square degrees within
a 1000 square degree field. These are the deepest CMB polarization maps at
degree angular scales to date. The power spectrum analysis presented in a
companion paper has resulted in a significant detection of B-mode polarization
at degree scales.
[37]
oai:arXiv.org:1407.5928 [pdf] - 1215833
BICEP3: a 95 GHz refracting telescope for degree-scale CMB polarization
Ahmed, Z.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bowens-Rubin, R.;
Buder, I.;
Bullock, E.;
Connors, J.;
Filippini, J. P.;
Grayson, J. A.;
Halpern, M.;
Hilton, G. C.;
Hristov, V. V.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kovac, J. M.;
Kuo, C. L.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Pryke, C.;
Reintsema, C. D.;
Richter, S.;
Thompson, K. L.;
Turner, A. D.;
Vieregg, A. G.;
Wu, W. L. K.;
Yoon, K. W.
Submitted: 2014-07-22
BICEP3 is a 550 mm-aperture refracting telescope for polarimetry of radiation
in the cosmic microwave background at 95 GHz. It adopts the methodology of
BICEP1, BICEP2 and the Keck Array experiments - it possesses sufficient
resolution to search for signatures of the inflation-induced cosmic
gravitational-wave background while utilizing a compact design for ease of
construction and to facilitate the characterization and mitigation of
systematics. However, BICEP3 represents a significant breakthrough in
per-receiver sensitivity, with a focal plane area 5$\times$ larger than a
BICEP2/Keck Array receiver and faster optics ($f/1.6$ vs. $f/2.4$).
Large-aperture infrared-reflective metal-mesh filters and infrared-absorptive
cold alumina filters and lenses were developed and implemented for its optics.
The camera consists of 1280 dual-polarization pixels; each is a pair of
orthogonal antenna arrays coupled to transition-edge sensor bolometers and read
out by multiplexed SQUIDs. Upon deployment at the South Pole during the 2014-15
season, BICEP3 will have survey speed comparable to Keck Array 150 GHz (2013),
and will significantly enhance spectral separation of primordial B-mode power
from that of possible galactic dust contamination in the BICEP2 observation
patch.
[38]
oai:arXiv.org:1407.6894 [pdf] - 1215912
The performance of the bolometer array and readout system during the
2012/2013 flight of the E and B experiment (EBEX)
MacDermid, Kevin;
Aboobaker, Asad M.;
Ade, Peter;
Aubin, Francois;
Baccigalupi, Carlo;
Bandura, Kevin;
Bao, Chaoyun;
Borrill, Julian;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grain, Julien;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Hannes;
Irwin, Kent;
Johnson, Bradley;
Jaffe, Andrew;
Jones, Terry;
Kisner, Ted;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
Miller, Amber;
Milligan, Michael;
Pascale, Enzo;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Stompor, Radek;
Tristram, Matthieu;
Tucker, Greg;
Westbrook, Ben;
Zilic, Kyle
Submitted: 2014-07-22
EBEX is a balloon-borne telescope designed to measure the polarization of the
cosmic microwave background radiation. During its eleven day science flight in
the Austral Summer of 2012, it operated 955 spider-web transition edge sensor
(TES) bolometers separated into bands at 150, 250 and 410 GHz. This is the
first time that an array of TES bolometers has been used on a balloon platform
to conduct science observations. Polarization sensitivity was provided by a
wire grid and continuously rotating half-wave plate. The balloon implementation
of the bolometer array and readout electronics presented unique development
requirements. Here we present an outline of the readout system, the remote
tuning of the bolometers and Superconducting QUantum Interference Device
(SQUID) amplifiers, and preliminary current noise of the bolometer array and
readout system.
[39]
oai:arXiv.org:1407.1883 [pdf] - 1215475
Attitude determination for balloon-borne experiments
Gandilo, N. N.;
Ade, P. A. R.;
Amiri, M.;
Angile, F. E.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Devlin, M. J.;
Dober, B.;
Dore, O. P.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Fukui, Y.;
Galitzki, N.;
Gambrel, A. E.;
Golwala, S.;
Gudmundsson, J. E.;
Halpern, M.;
Hasselfield, M.;
Hilton, G. C.;
Holmes, W. A.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kermish, Z. D.;
Klein, J.;
Korotkov, A. L.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Matthews, T. G.;
Megerian, K. G.;
Moncelsi, L.;
Morford, T. A.;
Mroczkowski, T. K.;
Nagy, J. M.;
Netterfield, C. B.;
Novak, G.;
Nutter, D.;
O'Brient, R.;
Pascale, E.;
Poidevin, F.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Savini, G.;
Scott, D.;
Shariff, J. A.;
Soler, J. D.;
Thomas, N. E.;
Trangsrud, A.;
Truch, M. D.;
Tucker, C. E.;
Tucker, G. S.;
Tucker, R. S.;
Turner, A. D.;
Ward-Thompson, D.;
Weber, A. C.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2014-07-07, last modified: 2014-07-15
An attitude determination system for balloon-borne experiments is presented.
The system provides pointing information in azimuth and elevation for
instruments flying on stratospheric balloons over Antarctica. In-flight
attitude is given by the real-time combination of readings from star cameras, a
magnetometer, sun sensors, GPS, gyroscopes, tilt sensors and an elevation
encoder. Post-flight attitude reconstruction is determined from star camera
solutions, interpolated by the gyroscopes using an extended Kalman Filter. The
multi-sensor system was employed by the Balloon-borne Large Aperture
Submillimeter Telescope for Polarimetry (BLASTPol), an experiment that measures
polarized thermal emission from interstellar dust clouds. A similar system was
designed for the upcoming flight of SPIDER, a Cosmic Microwave Background
polarization experiment. The pointing requirements for these experiments are
discussed, as well as the challenges in designing attitude reconstruction
systems for high altitude balloon flights. In the 2010 and 2012 BLASTPol
flights from McMurdo Station, Antarctica, the system demonstrated an accuracy
of <5' rms in-flight, and <5" rms post-flight.
[40]
oai:arXiv.org:1407.2906 [pdf] - 1215590
Pre-flight integration and characterization of the SPIDER balloon-borne
telescope
Rahlin, A. S.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Doré, O.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Gambrel, A. E.;
Gandilo, N. N.;
Golwala, S.;
Gudmundsson, J. E.;
Halpern, M.;
Hasselfield, M. F.;
Hilton, G.;
Holmes, W. A.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kermish, Z. D.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
O'Brient, R.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Weber, A. C.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2014-07-09
We present the results of integration and characterization of the SPIDER
instrument after the 2013 pre-flight campaign. SPIDER is a balloon-borne
polarimeter designed to probe the primordial gravitational wave signal in the
degree-scale $B$-mode polarization of the cosmic microwave background. With six
independent telescopes housing over 2000 detectors in the 94 GHz and 150 GHz
frequency bands, SPIDER will map 7.5% of the sky with a depth of 11 to 14
$\mu$K$\cdot$arcmin at each frequency, which is a factor of $\sim$5 improvement
over Planck. We discuss the integration of the pointing, cryogenic,
electronics, and power sub-systems, as well as pre-flight characterization of
the detectors and optical systems. SPIDER is well prepared for a December 2014
flight from Antarctica, and is expected to be limited by astrophysical
foreground emission, and not instrumental sensitivity, over the survey region.
[41]
oai:arXiv.org:1407.1880 [pdf] - 1215472
Pointing control for the SPIDER balloon-borne telescope
Shariff, Jamil A.;
Ade, Peter A. R.;
Amiri, Mandana;
Benton, Steven J.;
Bock, Jamie J.;
Bond, J. Richard;
Bryan, Sean A.;
Chiang, H. Cynthia;
Contaldi, Carlo R.;
Crill, Brendan P.;
Doré, Olivier P.;
Farhang, Marzieh;
Filippini, Jeffrey P.;
Fissel, Laura M.;
Fraisse, Aurelien A.;
Gambrel, Anne E.;
Gandilo, Natalie N.;
Golwala, Sunil R.;
Gudmundsson, Jon E.;
Halpern, Mark;
Hasselfield, Matthew;
Hilton, Gene C.;
Holmes, Warren A.;
Hristov, Viktor V.;
Irwin, Kent D.;
Jones, William C.;
Kermish, Zigmund D.;
Kuo, Chao-Lin;
MacTavish, Carolyn J.;
Mason, Peter V.;
Megerian, Krikor G.;
Moncelsi, Lorenzo;
Morford, Tracy A.;
Nagy, Johanna M.;
Netterfield, C. Barth;
O'Brient, Roger;
Rahlin, Alexandra S.;
Reintsema, Carl D.;
Ruhl, John E.;
Runyan, Marcus C.;
Soler, Juan D.;
Trangsrud, Amy;
Tucker, Carole E.;
Tucker, Rebecca S.;
Turner, Anthony D.;
Weber, Alexis C.;
Wiebe, Donald V.;
Young, Edward Y.
Submitted: 2014-07-07
We present the technology and control methods developed for the pointing
system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed
to detect the imprint of primordial gravitational waves in the polarization of
the Cosmic Microwave Background radiation. We describe the two main components
of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A
13 kHz PI control loop runs on a digital signal processor, with feedback from
fibre optic rate gyroscopes. This system can control azimuthal speed with <
0.02 deg/s RMS error. To control elevation, SPIDER uses stepper-motor-driven
linear actuators to rotate the cryostat, which houses the optical instruments,
relative to the outer frame. With the velocity in each axis controlled in this
way, higher-level control loops on the onboard flight computers can implement
the pointing and scanning observation modes required for the experiment. We
have accomplished the non-trivial task of scanning a 5000 lb payload
sinusoidally in azimuth at a peak acceleration of 0.8 deg/s$^2$, and a peak
speed of 6 deg/s. We can do so while reliably achieving sub-arcminute pointing
control accuracy.
[42]
oai:arXiv.org:1407.1882 [pdf] - 1215474
BLASTbus electronics: general-purpose readout and control for
balloon-borne experiments
Benton, S. J.;
Ade, P. A.;
Amiri, M.;
Angilè, F. E.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Devlin, M. J.;
Dober, B.;
Doré, O. P.;
Dowell, C. D.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Fukui, Y.;
Galitzki, N.;
Gambrel, A. E.;
Gandilo, N. N.;
Golwala, S. R.;
Gudmundsson, J. E.;
Halpern, M.;
Hasselfield, M.;
Hilton, G. C.;
Holmes, W. A.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kermish, Z. D.;
Klein, J.;
Korotkov, A. L.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Matthews, T. G.;
Megerian, K. G.;
Moncelsi, L.;
Morford, T. A.;
Mroczkowski, T. K.;
Nagy, J. M.;
Netterfield, C. B.;
Novak, G.;
Nutter, D.;
O'Brient, R.;
Ogburn, R. W.;
Pascale, E.;
Poidevin, F.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Savini, G.;
Scott, D.;
Shariff, J. A.;
Soler, J. D.;
Thomas, N. E.;
Trangsrud, A.;
Truch, M. D.;
Tucker, C. E.;
Tucker, G. S.;
Tucker, R. S.;
Turner, A. D.;
Ward-Thompson, D.;
Weber, A. C.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2014-07-07
We present the second generation BLASTbus electronics. The primary purposes
of this system are detector readout, attitude control, and cryogenic
housekeeping, for balloon-borne telescopes. Readout of neutron transmutation
doped germanium (NTD-Ge) bolometers requires low noise and parallel acquisition
of hundreds of analog signals. Controlling a telescope's attitude requires the
capability to interface to a wide variety of sensors and motors, and to use
them together in a fast, closed loop. To achieve these different goals, the
BLASTbus system employs a flexible motherboard-daughterboard architecture. The
programmable motherboard features a digital signal processor (DSP) and
field-programmable gate array (FPGA), as well as slots for three
daughterboards. The daughterboards provide the interface to the outside world,
with versions for analog to digital conversion, and optoisolated digital
input/output. With the versatility afforded by this design, the BLASTbus also
finds uses in cryogenic, thermometry, and power systems. For accurate timing
control to tie everything together, the system operates in a fully synchronous
manner. BLASTbus electronics have been successfully deployed to the South Pole,
and flown on stratospheric balloons.
[43]
oai:arXiv.org:1407.1881 [pdf] - 1215473
Design and construction of a carbon fiber gondola for the SPIDER
balloon-borne telescope
Soler, J. D.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, C.;
Contaldi, C. C.;
Crill, B. P.;
Doré, O. P.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Gambrel, A. E.;
Gandilo, N. N.;
Golwala, S.;
Gudmundsson, J. E.;
Halpern, M.;
Hasselfield, M.;
Hilton, G. C.;
Holmes, W. A.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kermish, Z. D.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Megerian, K. G.;
Moncelsi, L.;
Nagy, J. M.;
Netterfield, C. B.;
O'Brient, R.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Shariff, J. A.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Weber, A. C.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2014-07-07
We introduce the light-weight carbon fiber and aluminum gondola designed for
the SPIDER balloon-borne telescope. SPIDER is designed to measure the
polarization of the Cosmic Microwave Background radiation with unprecedented
sensitivity and control of systematics in search of the imprint of inflation: a
period of exponential expansion in the early Universe. The requirements of this
balloon-borne instrument put tight constrains on the mass budget of the
payload. The SPIDER gondola is designed to house the experiment and guarantee
its operational and structural integrity during its balloon-borne flight, while
using less than 10% of the total mass of the payload. We present a construction
method for the gondola based on carbon fiber reinforced polymer tubes with
aluminum inserts and aluminum multi-tube joints. We describe the validation of
the model through Finite Element Analysis and mechanical tests.
[44]
oai:arXiv.org:1403.3985 [pdf] - 841049
BICEP2 I: Detection Of B-mode Polarization at Degree Angular Scales
Ade, P. A. R;
Aikin, R. W.;
Barkats, D.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Brevik, J. A.;
Buder, I.;
Bullock, E.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hristov, V. V.;
Irwin, K. D.;
Karkare, K. S.;
Kaufman, J. P.;
Keating, B. G.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E. M.;
Lueker, M.;
Mason, P.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Orlando, A.;
Pryke, C.;
Reintsema, C. D.;
Richter, S.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z. K.;
Sudiwala, R. V.;
Teply, G. P.;
Tolan, J. E.;
Turner, A. D.;
Vieregg, A. G.;
Wong, C. L.;
Yoon, K. W.
Submitted: 2014-03-16, last modified: 2014-06-23
(abridged for arXiv) We report results from the BICEP2 experiment, a cosmic
microwave background (CMB) polarimeter specifically designed to search for the
signal of inflationary gravitational waves in the B-mode power spectrum around
$\ell\sim80$. The telescope comprised a 26 cm aperture all-cold refracting
optical system equipped with a focal plane of 512 antenna coupled transition
edge sensor 150 GHz bolometers each with temperature sensitivity of
$\approx300\mu\mathrm{K}_\mathrm{CMB}\sqrt{s}$. BICEP2 observed from the South
Pole for three seasons from 2010 to 2012. A low-foreground region of sky with
an effective area of 380 square deg was observed to a depth of 87 nK deg in
Stokes $Q$ and $U$. We find an excess of $B$-mode power over the base
lensed-LCDM expectation in the range $30< \ell< 150$, inconsistent with the
null hypothesis at a significance of $> 5\sigma$. Through jackknife tests and
simulations we show that systematic contamination is much smaller than the
observed excess. We also examine a number of available models of polarized dust
emission and find that at their default parameter values they predict power
$\sim(5-10)\times$ smaller than the observed excess signal. However, these
models are not sufficiently constrained to exclude the possibility of dust
emission bright enough to explain the entire excess signal. Cross correlating
BICEP2 against 100 GHz maps from the BICEP1 experiment, the excess signal is
confirmed and its spectral index is found to be consistent with that of the
CMB, disfavoring dust at $1.7\sigma$. The observed $B$-mode power spectrum is
well fit by a lensed-LCDM + tensor theoretical model with tensor-to-scalar
ratio $r=0.20^{+0.07}_{-0.05}$, with $r=0$ disfavored at $7.0\sigma$.
Accounting for the contribution of foreground dust will shift this value
downward by an amount which will be better constrained with upcoming data sets.
[45]
oai:arXiv.org:1106.3087 [pdf] - 659433
SPIDER: Probing the Early Universe with a Suborbital Polarimeter
Fraisse, A. A.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S.;
Burger, B.;
Chiang, H. C.;
Clark, C. N.;
Contaldi, C. R.;
Crill, B. P.;
Davis, G.;
Doré, O.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Gandilo, N. N.;
Golwala, S.;
Gudmundsson, J. E.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Montroy, T. E.;
Morford, T. A.;
Netterfield, C. B.;
O'Dea, D. T.;
Rahlin, A. S.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Schenker, M. A.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Wiebe, D.
Submitted: 2011-06-15, last modified: 2013-05-02
We evaluate the ability of SPIDER, a balloon-borne polarimeter, to detect a
divergence-free polarization pattern ("B-modes") in the Cosmic Microwave
Background (CMB). In the inflationary scenario, the amplitude of this signal is
proportional to that of the primordial scalar perturbations through the
tensor-to-scalar ratio r. We show that the expected level of systematic error
in the SPIDER instrument is significantly below the amplitude of an interesting
cosmological signal with r=0.03. We present a scanning strategy that enables us
to minimize uncertainty in the reconstruction of the Stokes parameters used to
characterize the CMB, while accessing a relatively wide range of angular
scales. Evaluating the amplitude of the polarized Galactic emission in the
SPIDER field, we conclude that the polarized emission from interstellar dust is
as bright or brighter than the cosmological signal at all SPIDER frequencies
(90 GHz, 150 GHz, and 280 GHz), a situation similar to that found in the
"Southern Hole." We show that two ~20-day flights of the SPIDER instrument can
constrain the amplitude of the B-mode signal to r<0.03 (99% CL) even when
foreground contamination is taken into account. In the absence of foregrounds,
the same limit can be reached after one 20-day flight.
[46]
oai:arXiv.org:1301.3650 [pdf] - 832812
SCUBA-2: The 10000 pixel bolometer camera on the James Clerk Maxwell
Telescope
Holland, W. S.;
Bintley, D.;
Chapin, E. L.;
Chrysostomou, A.;
Davis, G. R.;
Dempsey, J. T.;
Duncan, W. D.;
Fich, M.;
Friberg, P.;
Halpern, M.;
Irwin, K. D.;
Jenness, T.;
Kelly, B. D.;
MacIntosh, M. J.;
Robson, E. I.;
Scott, D.;
Ade, P. A. R.;
Atad-Ettedgui, E.;
Berry, D. S.;
Craig, S. C.;
Gao, X.;
Gibb, A. G.;
Hilton, G. C.;
Hollister, M. I.;
Kycia, J. B.;
Lunney, D. W.;
McGregor, H.;
Montgomery, D.;
Parkes, W.;
Tilanus, R. P. J.;
Ullom, J. N.;
Walther, C. A.;
Walton, A. J.;
Woodcraft, A. L.;
Amiri, M.;
Atkinson, D.;
Burger, B.;
Chuter, T.;
Coulson, I. M.;
Doriese, W. B.;
Dunare, C.;
Economou, F.;
Niemack, M. D.;
Parsons, H. A. L.;
Reintsema, C. D.;
Sibthorpe, B.;
Smail, I.;
Sudiwala, R.;
Thomas, H. S.
Submitted: 2013-01-16
SCUBA-2 is an innovative 10000 pixel bolometer camera operating at
submillimetre wavelengths on the James Clerk Maxwell Telescope (JCMT). The
camera has the capability to carry out wide-field surveys to unprecedented
depths, addressing key questions relating to the origins of galaxies, stars and
planets. With two imaging arrays working simultaneously in the atmospheric
windows at 450 and 850 microns, the vast increase in pixel count means that
SCUBA-2 maps the sky 100-150 times faster than the previous SCUBA instrument.
In this paper we present an overview of the instrument, discuss the physical
characteristics of the superconducting detector arrays, outline the observing
modes and data acquisition, and present the early performance figures on the
telescope. We also showcase the capabilities of the instrument via some early
examples of the science SCUBA-2 has already undertaken. In February 2012,
SCUBA-2 began a series of unique legacy surveys for the JCMT community. These
surveys will take 2.5 years and the results are already providing complementary
data to the shorter wavelength, shallower, larger-area surveys from Herschel.
The SCUBA-2 surveys will also provide a wealth of information for further study
with new facilities such as ALMA, and future telescopes such as CCAT and SPICA.
[47]
oai:arXiv.org:1208.1247 [pdf] - 1150545
Antenna-coupled TES bolometers for the Keck Array, Spider, and Polar-1
O'Brient, R.;
Ade, P. A. R.;
Ahmed, Z.;
Aikin, R. W.;
Amiri, M.;
Benton, S.;
Bischoff, C.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Burger, B.;
Davis, G.;
Day, P.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Grayson, J.;
Halpern, M.;
Hasselfield, M.;
Hilton, G.;
Hristov, V. V.;
Hui, H.;
Irwin, K.;
Kernasovskiy, S.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E.;
Lueker, M.;
Megerian, K.;
Moncelsi, L.;
Netterfield, C. B.;
Nguyen, H. T.;
Ogburn, R. W.;
Pryke, C. L.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z.;
Sudiwala, R.;
Teply, G.;
Tolan, J. E.;
Turner, A. D.;
Tucker, R. S.;
Vieregg, A.;
Wiebe, D. V.;
Wilson, P.;
Wong, C. L.;
Wu, W. L. K.;
Yoon, K. W.
Submitted: 2012-08-06
Between the BICEP2 and Keck Array experiments, we have deployed over 1500
dual polarized antenna coupled bolometers to map the Cosmic Microwave
Background's polarization. We have been able to rapidly deploy these detectors
because they are completely planar with an integrated phased-array antenna.
Through our experience in these experiments, we have learned of several
challenges with this technology- specifically the beam synthesis in the
antenna- and in this paper we report on how we have modified our designs to
mitigate these challenges. In particular, we discus differential steering
errors between the polarization pairs' beam centroids due to microstrip cross
talk and gradients of penetration depth in the niobium thin films of our
millimeter wave circuits. We also discuss how we have suppressed side lobe
response with a Gaussian taper of our antenna illumination pattern. These
improvements will be used in Spider, Polar-1, and this season's retrofit of
Keck Array.
[48]
oai:arXiv.org:1208.0857 [pdf] - 1150513
Optimization and sensitivity of the Keck Array
Kernasovskiy, S.;
Ade, P. A. R.;
Aikin, R. W.;
Amiri, M.;
Benton, S.;
Bischoff, C.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Burger, B.;
Davis, G.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hiltion, G.;
Hristov, V. V.;
Irwin, K.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E.;
Lueker, M.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Pryke, C. L.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z.;
Sudiwala, R.;
Teply, G.;
Tolan, J. E.;
Turner, A. D.;
Vieregg, A.;
Wiebe, D. V.;
Wilson, P.;
Wongg, C. L.
Submitted: 2012-08-03
The Keck Array (SPUD) began observing the cosmic microwave background's
polarization in the winter of 2011 at the South Pole. The Keck Array follows
the success of the predecessor experiments Bicep and Bicep2, using five on-axis
refracting telescopes. These have a combined imaging array of 2500
antenna-coupled TES bolometers read with a SQUID-based time domain multiplexing
system. We will discuss the detector noise and the optimization of the readout.
The achieved sensitivity of the Keck Array is 11.5 {\mu}K_(CMB)*sqrt{s} in the
2012 configuration.
[49]
oai:arXiv.org:1208.0638 [pdf] - 1150486
BICEP2 and Keck Array operational overview and status of observations
Ogburn, R. W.;
Ade, P. A. R.;
Aikin, R. W.;
Amiri, M.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Bullock, E.;
Burger, B.;
Davis, G.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Gordon, M.;
Halpern, M.;
Hasselfield, M.;
Hilton, G.;
Hristov, V. V.;
Hui, H.;
Irwin, K.;
Kaufman, J. P.;
Keating, B. G.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E. M.;
Lueker, M.;
Montroy, T.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Orlando, A.;
Pryke, C. L.;
Reintsema, C.;
Richter, S.;
Ruhl, J. E.;
Runyan, M. C.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z. K.;
Sudiwala, R. V.;
Teply, G. P.;
Thompson, K.;
Tolan, J. E.;
Turner, A. D.;
Vieregg, A. G.;
Wiebe, D. V.;
Wilson, P.;
Wong, C. L.
Submitted: 2012-08-02
The BICEP2 and Keck Array experiments are designed to measure the
polarization of the cosmic microwave background (CMB) on angular scales of 2-4
degrees (l=50-100). This is the region in which the B-mode signal, a signature
prediction of cosmic inflation, is expected to peak. BICEP2 was deployed to the
South Pole at the end of 2009 and is in the middle of its third year of
observing with 500 polarization-sensitive detectors at 150 GHz. The Keck Array
was deployed to the South Pole at the end of 2010, initially with three
receivers--each similar to BICEP2. An additional two receivers have been added
during the 2011-12 summer. We give an overview of the two experiments, report
on substantial gains in the sensitivity of the two experiments after
post-deployment optimization, and show preliminary maps of CMB polarization
from BICEP2.
[50]
oai:arXiv.org:1201.6289 [pdf] - 476260
Code-division multiplexing for x-ray microcalorimeters
Stiehl, G. M.;
Doriese, W. B.;
Fowler, J. W.;
Hilton, G. C.;
Irwin, K. D.;
Reintsema, C. D.;
Schmidt, D. R.;
Swetz, D. S.;
Ullom, J. N.;
Vale., L. R.
Submitted: 2012-01-30
We demonstrate the code-division multiplexed (CDM) readout of eight
transition-edge sensor microcalorimeters. The energy resolution is 3.0 eV (full
width at half-maximum) or better at 5.9 keV, with a best resolution of 2.3 eV
and a mean of 2.6 eV over the seven modulated detectors. The flux-summing CDM
system is described and compared with similar time-division multiplexed (TDM)
readout. We show that the sqrt(Npixels) multiplexing disadvantage associated
with TDM is not present in CDM. This demonstration establishes CDM as both a
simple route to higher performance in existing TDM microcalorimetric
experiments and a long-term approach to reaching higher multiplexing factors.
[51]
oai:arXiv.org:1110.1608 [pdf] - 506520
Advanced code-division multiplexers for superconducting detector arrays
Irwin, K. D.;
Cho, H. M.;
Doriese, W. B.;
Fowler, J. W.;
Hilton, G. C.;
Niemack, M. D.;
Reintsema, C. D.;
Schmidt, D. R.;
Ullom, J. N.;
Vale, L. R.
Submitted: 2011-10-07
Multiplexers based on the modulation of superconducting quantum interference
devices are now regularly used in multi-kilopixel arrays of superconducting
detectors for astrophysics, cosmology, and materials analysis. Over the next
decade, much larger arrays will be needed. These larger arrays require new
modulation techniques and compact multiplexer elements that fit within each
pixel. We present a new in-focal-plane code-division multiplexer that provides
multiplexing elements with the required scalability. This code-division
multiplexer uses compact lithographic modulation elements that simultaneously
multiplex both signal outputs and superconducting transition-edge sensor (TES)
detector bias voltages. It eliminates the shunt resistor used to voltage bias
TES detectors, greatly reduces power dissipation, allows different dc bias
voltages for each TES, and makes all elements sufficiently compact to fit
inside the detector pixel area. These in-focal-plane code-division multiplexers
can be combined with multi-gigahertz readout based on superconducting
microresonators to scale to even larger arrays.
[52]
oai:arXiv.org:1106.2507 [pdf] - 372118
Thermal architecture for the SPIDER flight cryostat
Gudmundsson, J. E.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
O'Dea, D.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Gandilo, N. N.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Helson, K. R.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Montroy, T. E.;
Morford, T. A.;
Netterfield, C. B.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Schenker, M. A.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.
Submitted: 2011-06-13
We describe the cryogenic system for SPIDER, a balloon-borne microwave
polarimeter that will map 8% of the sky with degree-scale angular resolution.
The system consists of a 1284 L liquid helium cryostat and a 16 L
capillary-filled superfluid helium tank, which provide base operating
temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption
refrigerators supply sub-Kelvin cooling power to multiple focal planes, which
are housed in monochromatic telescope inserts. The main helium tank is
suspended inside the vacuum vessel with thermally insulating fiberglass
flexures, and shielded from thermal radiation by a combination of two vapor
cooled shields and multi-layer insulation. This system allows for an extremely
low instrumental background and a hold time in excess of 25 days. The total
mass of the cryogenic system, including cryogens, is approximately 1000 kg.
This enables conventional long duration balloon flights. We will discuss the
design, thermal analysis, and qualification of the cryogenic system.
[53]
oai:arXiv.org:1106.2158 [pdf] - 371654
SPIDER: a balloon-borne CMB polarimeter for large angular scales
Filippini, J. P.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S. A.;
Burger, B.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Doré, O.;
Farhang, M.;
Fissel, L. M.;
Gandilo, N. N.;
Golwala, S. R.;
Gudmundsson, J. E.;
Halpern, M.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Montroy, T. E.;
Morford, T. A.;
Netterfield, C. B.;
O'Dea, D. T.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Schenker, M. A.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.
Submitted: 2011-06-10
We describe SPIDER, a balloon-borne instrument to map the polarization of the
millimeter-wave sky with degree angular resolution. Spider consists of six
monochromatic refracting telescopes, each illuminating a focal plane of
large-format antenna-coupled bolometer arrays. A total of 2,624 superconducting
transition-edge sensors are distributed among three observing bands centered at
90, 150, and 280 GHz. A cold half-wave plate at the aperture of each telescope
modulates the polarization of incoming light to control systematics. Spider's
first flight will be a 20-30-day Antarctic balloon campaign in December 2011.
This flight will map \sim8% of the sky to achieve unprecedented sensitivity to
the polarization signature of the gravitational wave background predicted by
inflationary cosmology. The Spider mission will also serve as a proving ground
for these detector technologies in preparation for a future satellite mission.
[54]
oai:arXiv.org:1106.2173 [pdf] - 372068
Design and performance of the Spider instrument
Runyan, M. C.;
Ade, P. A. R.;
Amiri, M.;
Benton, S.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Dore, O.;
O'Dea, D.;
Farhang, M.;
Filippini, J. P.;
Fissel, L.;
Gandilo, N.;
Golwala, S. R.;
Gudmundsson, J. E.;
Hasselfield, M.;
Halpern, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Morford, T. A.;
Montroy, T. E.;
Netterfield, C. B.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Schenker, M. A.;
Shariff, J.;
Soler, J. D.;
Trangsrud, A.;
Tucker, R. S.;
Tucker, C.;
Turner, A.
Submitted: 2011-06-10
Here we describe the design and performance of the Spider instrument. Spider
is a balloon-borne cosmic microwave background polarization imager that will
map part of the sky at 90, 145, and 280 GHz with sub-degree resolution and high
sensitivity. This paper discusses the general design principles of the
instrument inserts, mechanical structures, optics, focal plane architecture,
thermal architecture, and magnetic shielding of the TES sensors and SQUID
multiplexer. We also describe the optical, noise, and magnetic shielding
performance of the 145 GHz prototype instrument insert.
[55]
oai:arXiv.org:1104.5516 [pdf] - 350687
The Keck Array: a pulse tube cooled CMB polarimeter
Sheehy, C. D.;
Ade, P. A. R.;
Aikin, R. W.;
Amiri, M.;
Benton, S.;
Bischoff, C.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Burger, B.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hilton, G.;
Hristov, V. V.;
Irwin, K.;
Kaufman, J. P.;
Keating, B. G.;
Kovac, J. M.;
Kuo, C. L.;
Lange, A. E.;
Leitch, E. M.;
Lueker, M.;
Netterfield, C. B.;
Nguyen, H. T.;
Ogburn, R. W.;
Orlando, A.;
Pryke, C. L.;
Reintsema, C.;
Richter, S.;
Ruhl, J. E.;
Runyan, M. C.;
Staniszewski, Z.;
Stokes, S.;
Sudiwala, R.;
Teply, G.;
Thompson, K. L.;
Tolan, J. E.;
Turner, A. D.;
Wilson, P.;
Wong, C. L.
Submitted: 2011-04-28
The Keck Array is a cosmic microwave background (CMB) polarimeter that will
begin observing from the South Pole in late 2010. The initial deployment will
consist of three telescopes similar to BICEP2 housed in ultra-compact, pulse
tube cooled cryostats. Two more receivers will be added the following year. In
these proceedings we report on the design and performance of the Keck cryostat.
We also report some initial results on the performance of antenna-coupled TES
detectors operating in the presence of a pulse tube. We find that the
performance of the detectors is not seriously impacted by the replacement of
BICEP2's liquid helium cryostat with a pulse tube cooled cryostat.
[56]
oai:arXiv.org:1102.0559 [pdf] - 1051855
Spider Optimization II: Optical, Magnetic and Foreground Effects
O'Dea, D. T.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S.;
Burger, B.;
Chiang, H. C.;
Clark, C. N.;
Contaldi, C. R.;
Crill, B. P.;
Davis, G.;
Dore, O.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Gandilo, N. N.;
Golwala, S.;
Gudmundsson, J. E.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Montroy, T. E.;
Morford, T. A.;
Netterfield, C. B.;
Rahlin, A. S.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Schenker, M. A.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Wiebe, D.
Submitted: 2011-02-02
Spider is a balloon-borne instrument designed to map the polarization of the
cosmic microwave background (CMB) with degree-scale resolution over a large
fraction of the sky. Spider's main goal is to measure the amplitude of
primordial gravitational waves through their imprint on the polarization of the
CMB if the tensor-to-scalar ratio, r, is greater than 0.03. To achieve this
goal, instrumental systematic errors must be controlled with unprecedented
accuracy. Here, we build on previous work to use simulations of Spider
observations to examine the impact of several systematic effects that have been
characterized through testing and modeling of various instrument components. In
particular, we investigate the impact of the non-ideal spectral response of the
half-wave plates, coupling between focal plane components and the Earth's
magnetic field, and beam mismatches and asymmetries. We also present a model of
diffuse polarized foreground emission based on a three-dimensional model of the
Galactic magnetic field and dust, and study the interaction of this foreground
emission with our observation strategy and instrumental effects. We find that
the expected level of foreground and systematic contamination is sufficiently
low for Spider to achieve its science goals.
[57]
oai:arXiv.org:1009.3685 [pdf] - 1040693
Antenna-coupled TES Bolometer Arrays for BICEP2/Keck and SPIDER
Orlando, A.;
Aikin, R. W;
Amiri, M.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Burger, B.;
Chattopadthyay, G.;
Day, P. K.;
Filippini, J. P.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hilton, G. C.;
Irwin, K. D.;
Kenyon, M.;
Kovac, J. M.;
Kuo, C. L.;
Lange, A. E.;
LeDuc, H. G.;
Llombart, N.;
Nguyen, H. T.;
Ogburn, R. W.;
Reintsema, C. D.;
Runyan, M. C.;
Staniszewski, Z.;
Sudiwala, R.;
Teply, G.;
Trangsrud, A. R.;
Turner, A. D.;
Wilson, P.
Submitted: 2010-09-19
BICEP2/Keck and SPIDER are cosmic microwave background (CMB) polarimeters
targeting the B-mode polarization induced by primordial gravitational waves
from inflation. They will be using planar arrays of polarization sensitive
antenna-coupled TES bolometers, operating at frequencies between 90 GHz and 220
GHz. At 150 GHz each array consists of 64 polarimeters and four of these arrays
are assembled together to make a focal plane, for a total of 256
dual-polarization elements (512 TES sensors). The detector arrays are
integrated with a time-domain SQUID multiplexer developed at NIST and read out
using the multi-channels electronics (MCE) developed at the University of
British Columbia. Following our progress in improving detector parameters
uniformity across the arrays and fabrication yield, our main effort has focused
on improving detector arrays optical and noise performances, in order to
produce science grade focal planes achieving target sensitivities. We report on
changes in detector design implemented to optimize such performances and
following focal plane arrays characterization. BICEP2 has deployed a first 150
GHz science grade focal plane to the South Pole in December 2009.
[58]
oai:arXiv.org:1008.5106 [pdf] - 1034561
Time-division SQUID multiplexers with reduced sensitivity to external
magnetic fields
Submitted: 2010-08-30
Time-division SQUID multiplexers are used in many applications that require
exquisite control of systematic error. One potential source of systematic error
is the pickup of external magnetic fields in the multiplexer. We present
measurements of the field sensitivity figure of merit, effective area, for both
the first stage and second stage SQUID amplifiers in three NIST SQUID
multiplexer designs. These designs include a new variety with improved
gradiometry that significantly reduces the effective area of both the first and
second stage SQUID amplifiers.
[59]
oai:arXiv.org:1006.3874 [pdf] - 934286
Modeling and characterization of the SPIDER half-wave plate
Bryan, Sean A.;
Ade, Peter A. R.;
Amiri, Mandana;
Benton, Steve;
Bihary, Richard;
Bock, James J.;
Bond, J. Richard;
Bonetti, Joseph A.;
Chiang, H. Cynthia;
Contaldi, Carlo R.;
Crill, Brendan P.;
O'Dea, Daniel;
Dore, Olivier;
Farhang, Marzieh;
Filippini, Jeffrey P.;
Fissel, Laura;
Gandilo, Natalie;
Golwala, Sunil;
Gudmundsson, Jon E.;
Hasselfield, Matthew;
Halpern, Mark;
Helson, Kyle R.;
Hilton, Gene;
Holmes, Warren;
Hristov, Viktor V.;
Irwin, Kent D.;
Jones, William C.;
Kuo, Chao Lin;
MacTavish, Carrie J.;
Mason, Peter;
Morford, Tracy;
Montroy, Thomas E.;
Netterfield, C. Barth;
Rahlin, Alexandra S.;
Reintsema, Carl D.;
Riley, Daniel;
Ruhl, John E.;
Runyan, Marcus C.;
Schenker, Matthew A.;
Shariff, Jamil;
Soler, Juan Diego;
Trangsrud, Amy;
Tucker, Rebecca;
Tucker, Carole;
Turner, Anthony
Submitted: 2010-06-19
Spider is a balloon-borne array of six telescopes that will observe the
Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the
instrument will make a polarization map of the CMB with approximately one-half
degree resolution at 145 GHz. Polarization modulation is achieved via a
cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have
measured millimeter-wave transmission spectra of the sapphire at room and
cryogenic temperatures. The spectra are consistent with our physical optics
model, and the data gives excellent measurements of the indices of A-cut
sapphire. We have also taken preliminary spectra of the integrated HWP, optical
system, and detectors in the prototype Spider receiver. We calculate the
variation in response of the HWP between observing the CMB and foreground
spectra, and estimate that it should not limit the Spider constraints on
inflation.
[60]
oai:arXiv.org:1005.3339 [pdf] - 168465
The EBEX Cryostat and Supporting Electronics
Sagiv, Ilan;
Aboobaker, Asad M.;
Bao, Chaoyun;
Hanany, Shaul;
Jones, Terry;
Klein, Jeffrey;
Milligan, Michael;
Polsgrove, Daniel E.;
Raach, Kate;
Zilic, Kyle;
Korotkov, Andrei;
Tucker, Gregory S.;
Vinukurov, Yuri;
Matsumura, Tomotake;
Ade, Peter;
Grainger, Will;
Pascale, Enzo;
Chapman, Daniel;
Didier, Joy;
Hillbrand, Seth;
Reichborn-Kjennerud, Britt;
Limon, Michele;
Miller, Amber;
Jaffe, Andrew;
Yadav, Amit;
Zaldarriaga, Matias;
Ponthieu, Nicolas;
Tristram, Matthieu;
Borrill, Julian;
Cantalupo, Christopher;
Kisner, Ted;
Aubin, Francois;
Dobbs, Matt;
MacDermid, Kevin;
Hilton, Gene;
Hubmayr, Johhannes;
Irwin, Kent;
Reintsema, Carl;
Baccigalupi, Carlo;
Leach, Sam;
Johnson, Bradley;
Lee, Adrian;
Tran, Huan;
Levinson, Lorne
Submitted: 2010-05-18
We describe the cryostat and supporting electronics for the EBEX experiment.
EBEX is a balloon-borne polarimeter designed to measure the B-mode polarization
of the cosmic microwave background radiation. The instrument includes a 1.5
meter Gregorian-type telescope and 1432 bolometric transition edge sensor
detectors operating at 0.3 K. Electronics for monitoring temperatures and
controlling cryostat refrigerators is read out over CANbus. A timing system
ensures the data from all subsystems is accurately synchronized. EBEX completed
an engineering test flight in June 2009 during which the cryogenics and
supporting electronics performed according to predictions. The temperatures of
the cryostat were stable, and an analysis of a subset of the data finds no scan
synchronous signal in the cryostat temperatures. Preparations are underway for
an Antarctic flight.
[61]
oai:arXiv.org:0805.3690 [pdf] - 12907
Detecting the B-mode Polarisation of the CMB with Clover
North, C. E.;
Johnson, B. R.;
Ade, P. A. R.;
Audley, M. D.;
Baines, C.;
Battye, R. A.;
Brown, M. L.;
Cabella, P.;
Calisse, P. G.;
Challinor, A. D.;
Duncan, W. D.;
Ferreira, P. G.;
Gear, W. K.;
Glowacka, D.;
Goldie, D. J.;
Grimes, P. K.;
Halpern, M.;
Haynes, V.;
Hilton, G. C.;
Irwin, K. D.;
Jones, M. E.;
Lasenby, A. N.;
Leahy, P. J.;
Leech, J.;
Maffei, B.;
Mauskopf, P.;
Melhuish, S. J.;
O'Dea, D.;
Parsley, S. M.;
Piccirillo, L.;
Pisano, G.;
Reintsema, C. D.;
Savini, G.;
Sudiwala, R.;
Sutton, D.;
Taylor, A. C.;
Teleberg, G.;
Titterington, D.;
Tsaneva, V.;
Tucker, C.;
Watson, R.;
Withington, S.;
Yassin, G.;
Zhang, J.
Submitted: 2008-05-23, last modified: 2008-06-03
We describe the objectives, design and predicted performance of Clover, which
is a ground-based experiment to measure the faint ``B-mode'' polarisation
pattern in the cosmic microwave background (CMB). To achieve this goal, clover
will make polarimetric observations of approximately 1000 deg^2 of the sky in
spectral bands centred on 97, 150 and 225 GHz. The observations will be made
with a two-mirror compact range antenna fed by profiled corrugated horns. The
telescope beam sizes for each band are 7.5, 5.5 and 5.5 arcmin, respectively.
The polarisation of the sky will be measured with a rotating half-wave plate
and stationary analyser, which will be an orthomode transducer. The sky
coverage combined with the angular resolution will allow us to measure the
angular power spectra between 20 < l < 1000. Each frequency band will employ
192 single polarisation, photon noise limited TES bolometers cooled to 100 mK.
The background-limited sensitivity of these detector arrays will allow us to
constrain the tensor-to-scalar ratio to 0.026 at 3sigma, assuming any polarised
foreground signals can be subtracted with minimal degradation to the 150 GHz
sensitivity. Systematic errors will be mitigated by modulating the polarisation
of the sky signals with the rotating half-wave plate, fast azimuth scans and
periodic telescope rotations about its boresight. The three spectral bands will
be divided into two separate but nearly identical instruments - one for 97 GHz
and another for 150 and 225 GHz. The two instruments will be sited on identical
three-axis mounts in the Atacama Desert in Chile near Pampa la Bola.
Observations are expected to begin in late 2009.
[62]
oai:arXiv.org:astro-ph/0608285 [pdf] - 84162
Prototype finline-coupled TES bolometers for CLOVER
Audley, Michael D.;
Barker, Robert W.;
Crane, Michael;
Dace, Roger;
Glowacka, Dorota;
Goldie, David J.;
Lasenby, Anthony N.;
Stevenson, Howard M.;
Tsaneva, Vassilka;
Withington, Stafford;
Grimes, Paul;
Johnson, Bradley;
Yassin, Ghassan;
Piccirillo, Lucio;
Pisano, Giampaolo;
Duncan, William D.;
Hilton, Gene C.;
Irwin, Kent D.;
Reintsema, Carl D.;
Halpern, Mark
Submitted: 2006-08-14
CLOVER is an experiment which aims to detect the signature of gravitational
waves from inflation by measuring the B-mode polarization of the cosmic
microwave background. CLOVER consists of three telescopes operating at 97, 150,
and 220 GHz. The 97-GHz telescope has 160 feedhorns in its focal plane while
the 150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a
hexagonal array and feed a polarimeter which uses finline-coupled TES
bolometers as detectors. To detect the two polarizations the 97-GHz telescope
has 320 detectors while the 150 and 220-GHz telescopes have 512 detectors each.
To achieve the target NEPs (1.5, 2.5, and 4.5x10^-17 W/rtHz) the detectors are
cooled to 100 mK for the 97 and 150-GHz polarimeters and 230 mK for the 220-GHz
polarimeter. Each detector is fabricated as a single chip to ensure a 100%
operational focal plane. The detectors are contained in linear modules made of
copper which form split-block waveguides. The detector modules contain 16 or 20
detectors each for compatibility with the hexagonal arrays of horns in the
telescopes' focal planes. Each detector module contains a time-division SQUID
multiplexer to read out the detectors. Further amplification of the multiplexed
signals is provided by SQUID series arrays. The first prototype detectors for
CLOVER operate with a bath temperature of 230 mK and are used to validate the
detector design as well as the polarimeter technology. We describe the design
of the CLOVER detectors, detector blocks, and readout, and present preliminary
measurements of the prototype detectors performance.
[63]
oai:arXiv.org:astro-ph/0607067 [pdf] - 1463183
TES imaging array technology for CLOVER
Audley, Michael D.;
Barker, Robert W.;
Crane, Michael;
Dace, Roger;
Glowacka, Dorota;
Goldie, David J.;
Lasenby, Anthony N.;
Stevenson, Howard M.;
Tsaneva, Vassilka;
Withington, Stafford;
Grimes, Paul;
Johnson, Bradley;
Yassin, Ghassan;
Piccirillo, Lucio;
Pisano, Giampaolo;
Duncan, William D.;
Hilton, Gene C.;
Irwin, Kent D.;
Reintsema, Carl D.;
Halpern, Mark
Submitted: 2006-07-05
CLOVER is an experiment which aims to detect the signature of gravitational
waves from inflation by measuring the B-mode polarization of the cosmic
microwave background. CLOVER consists of three telescopes operating at 97, 150,
and 220 GHz. The 97-GHz telescope has 160 horns in its focal plane while the
150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a
hexagonal array and feed a polarimeter which uses finline-coupled TES
bolometers as detectors. To detect the two polarizations the 97-GHz telescope
has 320 detectors while the 150 and 220-GHz telescopes have 512 detectors each.
To achieve the required NEPs the detectors are cooled to 100 mK for the 97 and
150-GHz polarimeters and 230 mK for the 220-GHz polarimeter. Each detector is
fabricated as a single chip to guarantee fully functioning focal planes. The
detectors are contained in linear modules made of copper which form split-block
waveguides. The detector modules contain 16 or 20 detectors each for
compatibility with the hexagonal arrays of horns in the telescopes' focal
planes. Each detector module contains a time-division SQUID multiplexer to read
out the detectors. Further amplification of the multiplexed signals is provided
by SQUID series arrays. The first prototype detectors for CLOVER operate with a
bath temperature of 230 mK and are used to validate the detector design as well
as the polarimeter technology. We describe the design of the CLOVER detectors,
detector blocks, and readout, and give an update on the detector development.
[64]
oai:arXiv.org:astro-ph/0606338 [pdf] - 82778
SCUBA-2: a 10,000 pixel submillimeter camera for the James Clerk Maxwell
Telescope
Holland, Wayne;
MacIntosh, Michael;
Fairley, Alasdair;
Kelly, Dennis;
Montgomery, David;
Gostick, David;
Atad-Ettedgui, Eli;
Ellis, Maureen;
Robson, Ian;
Hollister, Matthew;
Woodcraft, Adam;
Ade, Peter;
Walker, Ian;
Irwin, Kent;
Hilton, Gene;
Duncan, William;
Reintsema, Carl;
Walton, Anthony;
Parkes, William;
Dunare, Camelia;
Fich, Michel;
Kycia, Jan;
Halpern, Mark;
Scott, Douglas;
Gibb, Andy;
Molnar, Janos;
Chapin, Ed;
Bintley, Dan;
Craig, Simon;
Chylek, Tomas;
Jenness, Tim;
Economou, Frossie;
Davis, Gary
Submitted: 2006-06-14
SCUBA-2 is an innovative 10,000 pixel submillimeter camera due to be
delivered to the James Clerk Maxwell Telescope in late 2006. The camera is
expected to revolutionize submillimeter astronomy in terms of the ability to
carry out wide-field surveys to unprecedented depths addressing key questions
relating to the origins of galaxies, stars and planets. This paper presents an
update on the project with particular emphasis on the laboratory commissioning
of the instrument. The assembly and integration will be described as well as
the measured thermal performance of the instrument. A summary of the
performance results will be presented from the TES bolometer arrays, which come
complete with in-focal plane SQUID amplifiers and multiplexed readouts, and are
cooled to 100mK by a liquid cryogen-free dilution refrigerator. Considerable
emphasis has also been placed on the operating modes of the instrument and the
common-user aspect of the user interface and data reduction pipeline. These
areas will also be described in the paper.
[65]
oai:arXiv.org:astro-ph/0410439 [pdf] - 1463182
An update on the SCUBA-2 project
Audley, Michael;
Holland, Wayne;
Hodson, Trevor;
MacIntosh, Mike;
Robson, Ian;
Irwin, Kent;
Hilton, Gene;
Duncan, William;
Reintsema, Carl;
Walton, Anthony;
Parkes, William;
Ade, Peter;
Walker, Ian;
Fich, Michel;
Kycia, Jan;
Halpern, Mark;
Naylor, David;
Mitchell, George;
Bastien, Pierre
Submitted: 2004-10-19
SCUBA-2, which replaces SCUBA (the Submillimeter Common User Bolometer Array)
on the James Clerk Maxwell Telescope (JCMT) in 2006, is a large-format
bolometer array for submillimeter astronomy. Unlike previous detectors which
have used discrete bolometers, SCUBA-2 has two dc-coupled, monolithic, filled
arrays with a total of ~10,000 bolometers. It will offer simultaneous imaging
of a 50 sq-arcmin field of view at wavelengths of 850 and 450 microns. SCUBA-2
is expected to have a huge impact on the study of galaxy formation and
evolution in the early Universe as well as star and planet formation in our own
Galaxy. Mapping the sky to the same S/N up to 1000 times faster than SCUBA, it
will also act as a pathfinder for the new submillimeter interferometers such as
ALMA. SCUBA-2's absorber-coupled pixels use superconducting transition edge
sensors operating at 120 mK for performance limited by the sky background
photon noise. The monolithic silicon detector arrays are deep-etched by the
Bosch process to isolate the pixels on silicon nitride membranes. Electrical
connections are made through indium bump bonds to a SQUID time-domain
multiplexer (MUX). We give an overview of the SCUBA-2 system and an update on
its status, and describe some of the technological innovations that make this
unique instrument possible.