Normalized to: Reichhart, L.
[1]
oai:arXiv.org:1907.06272 [pdf] - 2050176
Extending light WIMP searches to single scintillation photons in LUX
Akerib, D. S.;
Alsum, S.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Baxter, A.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Boxer, B.;
Brás, P.;
Burdin, S.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fallon, S. R.;
Fan, A.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Genovesi, J.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Grace, E.;
Gwilliam, C.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Jacobsen, R. G.;
Jahangir, O.;
Ji, W.;
Kamdin, K.;
Kazka, K.;
Khaitan, D.;
Knoche, R.;
Korolkova, E. V.;
Kravitz, S.;
Kudryavtsev, V. A.;
Larsen, N. A.;
Leason, E.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Levy, C.;
Liao, J.;
Lin, J.;
Lindote, A.;
Lopes, M. I.;
López-Paredes, B.;
Manalaysay, A.;
Mannino, R. L.;
Marangou, N.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Naylor, A.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
Nilima, A.;
O'Sullivan, K.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pease, E. K.;
Reichhart, L.;
Riffard, Q.;
Rischbieter, G. R. C.;
Rossiter, P.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, R.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Utku, U.;
Uvarov, S.;
Vacheret, A.;
Velan, V.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woodward, D.;
Xu, J.;
Yazdani, K.;
Young, S. K.;
Zhang, C.
Submitted: 2019-07-14, last modified: 2019-12-27
We present a novel analysis technique for liquid xenon time projection
chambers that allows for a lower threshold by relying on events with a prompt
scintillation signal consisting of single detected photons. The energy
threshold of the LUX dark matter experiment is primarily determined by the
smallest scintillation response detectable, which previously required a 2-fold
coincidence signal in its photomultiplier arrays, enforced in data analysis.
The technique presented here exploits the double photoelectron emission effect
observed in some photomultiplier models at vacuum ultraviolet wavelengths. We
demonstrate this analysis using an electron recoil calibration dataset and
place new constraints on the spin-independent scattering cross section of
weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass
using the 2013 LUX dataset. This new technique is promising to enhance light
WIMP and astrophysical neutrino searches in next-generation liquid xenon
experiments.
[3]
oai:arXiv.org:1704.02297 [pdf] - 1582421
First Searches for Axions and Axion-Like Particles with the LUX
Experiment
Akerib, D. S.;
Alsum, S.;
Aquino, C.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Brás, P.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
Davison, T. J. R.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fallon, S. R.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Manalaysay, A.;
Mannino, R. L.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
O'Sullivan, K.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pease, E. K.;
Reichhart, L.;
Rhyne, C.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Uvarov, S.;
Velan, V.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Xu, J.;
Yazdani, K.;
Young, S. K.;
Zhang, C.
Submitted: 2017-04-07, last modified: 2017-06-30
The first searches for axions and axion-like particles with the Large
Underground Xenon (LUX) experiment are presented. Under the assumption of an
axio-electric interaction in xenon, the coupling constant between axions and
electrons, gAe is tested, using data collected in 2013 with an exposure
totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood
ratio statistic test excludes gAe larger than 3.5 $\times$ 10$^{-12}$ (90%
C.L.) for solar axions. Assuming the DFSZ theoretical description, the upper
limit in coupling corresponds to an upper limit on axion mass of 0.12
eV/c$^{2}$, while for the KSVZ description masses above 36.6 eV/c$^{2}$ are
excluded. For galactic axion-like particles, values of gAe larger than 4.2
$\times$ 10$^{-13}$ are excluded for particle masses in the range 1-16
keV/c$^{2}$. These are the most stringent constraints to date for these
interactions.
[4]
oai:arXiv.org:1705.03380 [pdf] - 1583256
Limits on spin-dependent WIMP-nucleon cross section obtained from the
complete LUX exposure
LUX Collaboration;
Akerib, D. S.;
Alsum, S.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Brás, P.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
Davison, T. J. R.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fallon, S. R.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gilchriese, M. G. D.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Manalaysay, A.;
Mannino, R. L.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
O'Sullivan, K.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pease, E. K.;
Reichhart, L.;
Rhyne, C.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Uvarov, S.;
Velan, V.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Xu, J.;
Yazdani, K.;
Young, S. K.;
Zhang, C.
Submitted: 2017-05-09, last modified: 2017-06-23
We present experimental constraints on the spin-dependent WIMP-nucleon
elastic cross sections from the total 129.5 kg-year exposure acquired by the
Large Underground Xenon experiment (LUX), operating at the Sanford Underground
Research Facility in Lead, South Dakota (USA). A profile likelihood ratio
analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton)
cross section of $\sigma_n$ = 1.6$\times 10^{-41}$ cm$^{2}$ ($\sigma_p$ =
5$\times 10^{-40}$ cm$^{2}$) at 35 GeV$c^{-2}$, almost a sixfold improvement
over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron
limit is the most sensitive constraint to date.
[6]
oai:arXiv.org:1608.07648 [pdf] - 1531370
Results from a search for dark matter in the complete LUX exposure
Akerib, D. S.;
Alsum, S.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Bramante, R.;
Brás, P.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
Davison, T. J. R.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Ihm, M.;
Jacobsen, R. G.;
Ji, W.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Manalaysay, A.;
Mannino, R. L.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
O`Sullivan, K.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pease, E. K.;
Phelps, P.;
Reichhart, L.;
Rhyne, C.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Uvarov, S.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Xu, J.;
Yazdani, K.;
Young, S. K.;
Zhang, C.
Submitted: 2016-08-26, last modified: 2017-01-13
We report constraints on spin-independent weakly interacting massive particle
(WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large
Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber
with 250 kg of active mass is operated at the Sanford Underground Research
Facility under Lead, South Dakota (USA). With roughly fourfold improvement in
sensitivity for high WIMP masses relative to our previous results, this search
yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2,
WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at
the 90% confidence level. When combined with the previously reported LUX
exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
[7]
oai:arXiv.org:1608.05381 [pdf] - 1503451
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark
matter experiment using D-D neutron scattering kinematics
LUX Collaboration;
Akerib, D. S.;
Alsum, S.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Bradley, A.;
Bramante, R.;
Brás, P.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Ihm, M.;
Jacobsen, R. G.;
Ji, W.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Malling, D. C.;
Manalaysay, A.;
Mannino, R. L.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
O'Sullivan, K.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pangilinan, M.;
Pease, E. K.;
Phelps, P.;
Reichhart, L.;
Rhyne, C. A.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Uvarov, S.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Xu, J.;
Yazdani, K.;
Young, S. K.;
Zhang, C.
Submitted: 2016-08-18, last modified: 2016-10-26
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon
time projection chamber (TPC) operating at the Sanford Underground Research
Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid
xenon was performed $\textit{in situ}$ in the LUX detector using a collimated
beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium
(D-D) fusion source. The nuclear recoil energy from the first neutron scatter
in the TPC was reconstructed using the measured scattering angle defined by
double-scatter neutron events within the active xenon volume. We measured the
absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric
field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to
74 keV, respectively. This calibration of the nuclear recoil signal yields will
permit the further refinement of liquid xenon nuclear recoil signal models and,
importantly for dark matter searches, clearly demonstrates measured ionization
and scintillation signals in this medium at recoil energies down to
$\mathcal{O}$(1 keV).
[8]
oai:arXiv.org:1512.03506 [pdf] - 1406496
Improved Limits on Scattering of Weakly Interacting Massive Particles
from Reanalysis of 2013 LUX data
LUX Collaboration;
Akerib, D. S.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Bradley, A.;
Bramante, R.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Ihm, M.;
Jacobsen, R. G.;
Ji, W.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Malling, D. C.;
Manalaysay, A.;
Mannino, R. L.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
O`Sullivan, K.;
Oliver-Mallory, K. C.;
Ott, R. A.;
Palladino, K. J.;
Pangilinan, M.;
Pease, E. K.;
Phelps, P.;
Reichhart, L.;
Rhyne, C.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Uvarov, S.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Yazdani, K.;
Young, S. K.;
Zhang, C.
Submitted: 2015-12-10, last modified: 2016-05-16
We present constraints on weakly interacting massive particles (WIMP)-nucleus
scattering from the 2013 data of the Large Underground Xenon dark matter
experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure.
This new analysis incorporates several advances: single-photon calibration at
the scintillation wavelength, improved event-reconstruction algorithms, a
revised background model including events originating on the detector walls in
an enlarged fiducial volume, and new calibrations from decays of an injected
tritium $\beta$ source and from kinematically constrained nuclear recoils down
to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to
our previous results which modeled the signal only above a 3 keV minimum
energy. Under standard dark matter halo assumptions and in the mass range above
4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct
limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper
limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
[9]
oai:arXiv.org:1512.03133 [pdf] - 1402511
Tritium calibration of the LUX dark matter experiment
LUX Collaboration;
Akerib, D. S.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Bradley, A.;
Bramante, R.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Ihm, M.;
Jacobsen, R. G.;
Ji, W.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Malling, D. C.;
Manalaysay, A. G.;
Mannino, R. L.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
O`Sullivan, K.;
Oliver-Mallory, K. C.;
Ott, R. A.;
Palladino, K. J.;
Pangilinan, M.;
Pease, E. K.;
Phelps, P.;
Reichhart, L.;
Rhyne, C.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Uvarov, S.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Young, S. K.;
Zhang, C.
Submitted: 2015-12-09, last modified: 2016-05-05
We present measurements of the electron-recoil (ER) response of the LUX dark
matter detector based upon 170,000 highly pure and spatially-uniform tritium
decays. We reconstruct the tritium energy spectrum using the combined energy
model and find good agreement with expectations. We report the average charge
and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and
compare the results to the NEST model. We also measure the mean charge
recombination fraction and its fluctuations, and we investigate the location
and width of the LUX ER band. These results provide input to a re-analysis of
the LUX Run3 WIMP search.
[10]
oai:arXiv.org:1509.02910 [pdf] - 1286987
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration;
Akerib, D. S.;
Akerlof, C. W.;
Akimov, D. Yu.;
Alsum, S. K.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Barry, M. J.;
Bauer, P.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boast, K. E.;
Bolozdynya, A. I.;
Boulton, E. M.;
Bramante, R.;
Buckley, J. H.;
Bugaev, V. V.;
Bunker, R.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Cascella, M.;
Chan, C.;
Cherwinka, J. J.;
Chiller, A. A.;
Chiller, C.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
da Cunha, J. P.;
Dahl, C. E.;
Dasu, S.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, B. N.;
Edwards, W. R.;
Elnimr, M. M.;
Emmet, W. T.;
Faham, C. H.;
Fiorucci, S.;
Ford, P.;
Francis, V. B.;
Fu, C.;
Gaitskell, R. J.;
Gantos, N. J.;
Gehman, V. M.;
Gerhard, R. M.;
Ghag, C.;
Gilchriese, M. G. D.;
Gomber, B.;
Hall, C. R.;
Harris, A.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hoff, M. D.;
Holbrook, B.;
Holtom, E.;
Huang, D. Q.;
Hurteau, T. W.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Ji, X.;
Johnson, M.;
Ju, Y.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Khazov, A.;
Khromov, A. V.;
Konovalov, A. M.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kudryavtsev, V. A.;
Kumpan, A. V.;
Kyre, S.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Lippincott, W. H.;
Liu, J.;
Liu, X.;
Lopes, M. I.;
Lorenzon, W.;
Luitz, S.;
Majewski, P.;
Malling, D. C.;
Manalaysay, A. G.;
Manenti, L.;
Mannino, R. L.;
Markley, D. J.;
Martin, T. J.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. -M.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikkel, J. A.;
O'Neill, F. G.;
O'Dell, J.;
O'Sullivan, K.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pangilinan, M.;
Patton, S. J.;
Pease, E. K.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Reichhart, L.;
Rhyne, C.;
Rodrigues, J. P.;
Rose, H. J.;
Rosero, R.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M. S. G.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Sosnovtsev, V. V.;
Stancu, I.;
Stark, M. R.;
Stephenson, S.;
Stiegler, T. M.;
Sumner, T. J.;
Sundarnath, K.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W.;
Tennyson, B. P.;
Terman, P. A.;
Thomas, K. J.;
Thomson, J. A.;
Tiedt, D. R.;
To, W. H.;
Tomás, A.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Uvarov, S.;
Va'vra, J.;
van der Grinten, M. G. D.;
Verbus, J. R.;
Vuosalo, C. O.;
Waldron, W. L.;
Wang, L.;
Webb, R. C.;
Wei, W. -Z.;
While, M.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, E.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, S. K.;
Zhang, C.
Submitted: 2015-09-09, last modified: 2015-09-23
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of
March 2015 in this Conceptual Design Report. LZ is a second-generation
dark-matter detector with the potential for unprecedented sensitivity to weakly
interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds
of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most
sensitive experiment for WIMPs in this mass region by the end of the decade.
This report describes in detail the design of the LZ technical systems.
Expected backgrounds are quantified and the performance of the experiment is
presented. The LZ detector will be located at the Sanford Underground Research
Facility in South Dakota. The organization of the LZ Project and a summary of
the expected cost and current schedule are given.
[11]
oai:arXiv.org:1403.1299 [pdf] - 862558
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Coffey, T.;
Currie, A.;
de Viveiros, L.;
Dobi, A.;
Dobson, J.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Flores, C.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C.;
Hertel, S. A.;
Horn, M.;
Huang, D. Q.;
Ihm, M.;
Jacobsen, R. G.;
Kazkaz, K.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lindote, A.;
Lopes, M. I.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Moongweluwan, M.;
Morad, J.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H.;
Neves, F.;
Ott, R. A.;
Pangilinan, M.;
Parker, P. D.;
Pease, E. K.;
Pech, K.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Solovov, V. N.;
Sorensen, P.;
O'Sullivan, K.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D.;
Tennyson, B.;
Tiedt, D. R.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2014-03-05
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare
low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The
radiogenic backgrounds in the LUX detector have been measured and compared with
Monte Carlo simulation. Measurements of LUX high-energy data have provided
direct constraints on all background sources contributing to the background
model. The expected background rate from the background model for the 85.3 day
WIMP search run is
$(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$
in a 118~kg fiducial volume. The observed background rate is
$(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$,
consistent with model projections. The expectation for the radiogenic
background in a subsequent one-year run is presented.
[12]
oai:arXiv.org:1402.3731 [pdf] - 788195
A Detailed Look at the First Results from the Large Underground Xenon
(LUX) Dark Matter Experiment
Szydagis, M.;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Coffey, T.;
Currie, A.;
de Viveiros, L.;
Dobi, A.;
Dobson, J.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Flores, C.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C.;
Hertel, S. A.;
Horn, M.;
Huang, D. Q.;
Ihm, M.;
Jacobsen, R. G.;
Kazkaz, K.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lindote, A.;
Lopes, M. I.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Moongweluwan, M.;
Morad, J.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H.;
Neves, F.;
Ott, R. A.;
Pangilinan, M.;
Parker, P. D.;
Pease, E. K.;
Pech, K.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Solovov, V. N.;
Sorensen, P.;
O'Sullivan, K.;
Sumner, T.;
Taylor, D.;
Tennyson, B.;
Tiedt, D. R.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2014-02-15, last modified: 2014-02-25
LUX, the world's largest dual-phase xenon time-projection chamber, with a
fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is
currently the most sensitive direct dark matter search experiment. The initial
null-result limit on the spin-independent WIMP-nucleon scattering cross-section
was released in October 2013, with a primary scintillation threshold of 2 phe,
roughly 3 keVnr for LUX. The detector has been deployed at the Sanford
Underground Research Facility (SURF) in Lead, South Dakota, and is the first
experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$
cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale
employed to better understand the nuclear recoil light and charge yields, and
of the calibration sources, including the new internal tritium source. We found
the LUX data to be in conflict with low-mass WIMP signal interpretations of
other results.
[13]
oai:arXiv.org:1310.8214 [pdf] - 795009
First results from the LUX dark matter experiment at the Sanford
Underground Research Facility
LUX Collaboration;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Clark, K.;
Coffey, T.;
Currie, A.;
Curioni, A.;
Dazeley, S.;
de Viveiros, L.;
Dobi, A.;
Dobson, J.;
Dragowsky, E. M.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Flores, C.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C.;
Hanhardt, M.;
Hertel, S. A.;
Horn, M.;
Huang, D. Q.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Knoche, R.;
Kyre, S.;
Lander, R.;
Larsen, N. A.;
Lee, C.;
Leonard, D. S.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Moongweluwan, M.;
Morad, J.;
Morii, M.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Ott, R. A.;
Pangilinan, M.;
Parker, P. D.;
Pease, E. K.;
Pech, K.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Sofka, C. J.;
Solovov, V. N.;
Sorensen, P.;
Stiegler, T.;
O`Sullivan, K.;
Sumner, T. J.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Tennyson, B.;
Tiedt, D. R.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
White, D.;
Witherell, M. S.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2013-10-30, last modified: 2014-02-05
The Large Underground Xenon (LUX) experiment, a dual-phase xenon
time-projection chamber operating at the Sanford Underground Research Facility
(Lead, South Dakota), was cooled and filled in February 2013. We report results
of the first WIMP search dataset, taken during the period April to August 2013,
presenting the analysis of 85.3 live-days of data with a fiducial volume of 118
kg. A profile-likelihood analysis technique shows our data to be consistent
with the background-only hypothesis, allowing 90% confidence limits to be set
on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit
on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33
GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass
WIMP signal interpretations of the results from several recent direct detection
experiments.
[14]
oai:arXiv.org:1112.1481 [pdf] - 1092209
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
Solovov, V. N.;
Belov, V. A.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Majewski, P.;
Murphy, A. St J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-12-07, last modified: 2012-09-26
We studied the application of statistical reconstruction algorithms, namely
maximum likelihood and least squares methods, to the problem of event
reconstruction in a dual phase liquid xenon detector. An iterative method was
developed for in-situ reconstruction of the PMT light response functions from
calibration data taken with an uncollimated gamma-ray source. Using the
techniques described, the performance of the ZEPLIN-III dark matter detector
was studied for 122 keV gamma-rays. For the inner part of the detector (R<100
mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the
horizontal plane for primary and secondary scintillation, respectively. An
energy resolution of 8.1% FWHM was achieved at that energy. The possibility of
using this technique for improving performance and reducing cost of
scintillation cameras for medical applications is currently under study.
[15]
oai:arXiv.org:1110.4769 [pdf] - 1085051
WIMP-nucleon cross-section results from the second science run of
ZEPLIN-III
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Bewick, A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Jones, W. G.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-10-21, last modified: 2011-12-16
We report experimental upper limits on WIMP-nucleon elastic scattering cross
sections from the second science run of ZEPLIN-III at the Boulby Underground
Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days
of continuous operation between June 2010 and May 2011. A total of eight events
was observed in the signal acceptance region in the nuclear recoil energy range
7-29 keV, which is compatible with background expectations. This allows the
exclusion of the scalar cross-section above 4.8E-8 pb near 50 GeV/c^2 WIMP mass
with 90% confidence. Combined with data from the first run, this result
improves to 3.9E-8 pb. The corresponding WIMP-neutron spin-dependent
cross-section limit is 8.0E-3 pb. The ZEPLIN programme reaches thus its
conclusion at Boulby, having deployed and exploited successfully three liquid
xenon experiments of increasing reach.
[16]
oai:arXiv.org:1111.2248 [pdf] - 1091528
Quenching Factor for Low Energy Nuclear Recoils in a Plastic
Scintillator
Reichhart, L.;
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Francis, V.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. St J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-11-09
Plastic scintillators are widely used in industry, medicine and scientific
research, including nuclear and particle physics. Although one of their most
common applications is in neutron detection, experimental data on their
response to low-energy nuclear recoils are scarce. Here, the relative
scintillation efficiency for neutron-induced nuclear recoils in a
polystyrene-based plastic scintillator (UPS-923A) is presented, exploring
recoil energies between 125 keV and 850 keV. Monte Carlo simulations,
incorporating light collection efficiency and energy resolution effects, are
used to generate neutron scattering spectra which are matched to observed
distributions of scintillation signals to parameterise the energy-dependent
quenching factor. At energies above 300 keV the dependence is reasonably
described using the semi-empirical formulation of Birks and a kB factor of
(0.014+/-0.002) g/MeVcm^2 has been determined. Below that energy the measured
quenching factor falls more steeply than predicted by the Birks formalism.
[17]
oai:arXiv.org:1110.0103 [pdf] - 967104
After LUX: The LZ Program
Malling, D. C.;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Coffey, T.;
Curioni, A.;
Currie, A.;
Dazeley, S.;
de Viveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Larsen, N.;
Lee, C.;
Leonard, D.;
Lesko, K.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Majewski, P.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Morii, M.;
Murphy, A. St J.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Sumner, T. J.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Thomson, J.;
Tripathi, M.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2011-10-01, last modified: 2011-10-13
The LZ program consists of two stages of direct dark matter searches using
liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the
last stage will be a 20 tonne detector. Both devices will benefit tremendously
from research and development performed for the LUX experiment, a 350 kg liquid
Xe dark matter detector currently operating at the Sanford Underground
Laboratory. In particular, the technology used for cryogenics and electrical
feedthroughs, circulation and purification, low-background materials and
shielding techniques, electronics, calibrations, and automated control and
recovery systems are all directly scalable from LUX to the LZ detectors.
Extensive searches for potential background sources have been performed, with
an emphasis on previously undiscovered background sources that may have a
significant impact on tonne-scale detectors. The LZ detectors will probe
spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV
WIMPs, which represents the ultimate limit for dark matter detection with
liquid xenon technology.
[18]
oai:arXiv.org:1106.0808 [pdf] - 1077078
ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Neves, F.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Majewski, P.;
Murphy, A. St J.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Rodrigues, S.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-06-04
ZE3RA is the software package responsible for processing the raw data from
the ZEPLIN-III dark matter experiment and its reduction into a set of
parameters used in all subsequent analyses. The detector is a liquid xenon time
projection chamber with scintillation and electroluminescence signals read out
by an array of 31 photomultipliers. The dual range 62-channel data stream is
optimised for the detection of scintillation pulses down to a single
photoelectron and of ionisation signals as small as those produced by single
electrons. We discuss in particular several strategies related to data
filtering, pulse finding and pulse clustering which are tuned to recover the
best electron/nuclear recoil discrimination near the detection threshold, where
most dark matter elastic scattering signatures are expected. The software was
designed assuming only minimal knowledge of the physics underlying the
detection principle, allowing an unbiased analysis of the experimental results
and easy extension to other detectors with similar requirements.
[19]
oai:arXiv.org:1103.0393 [pdf] - 385243
Performance of the veto detector incorporated into the ZEPLIN-III
experiment
Ghag, C.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Francis, V.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Lyons, K.;
Majewski, P.;
St, A.;
Murphy, J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-03-02, last modified: 2011-05-01
The ZEPLIN-III experiment is operating in its second phase at the Boulby
Underground Laboratory in search of dark matter WIMPs. The major upgrades to
the instrument over its first science run include lower background
photomultiplier tubes and installation of a plastic scintillator veto system.
Performance results from the veto detector using calibration and science data
in its first six months of operation in coincidence with ZEPLIN-III are
presented. With fully automated operation and calibration, the veto system has
maintained high stability and achieves near unity live time relative to
ZEPLIN-III. Calibrations with a neutron source demonstrate a rejection of 60%
of neutron-induced nuclear recoils in ZEPLIN-III that might otherwise be
misidentified as WIMPs. This tagging efficiency reduces the expected untagged
nuclear recoil background from neutrons during science data taking to a very
low rate of ~0.2 events per year in the WIMP acceptance region. Additionally,
the veto detector provides rejection of 28% of gamma-ray induced background
events, allowing the sampling of the dominant source of background in
ZEPLIN-III - multiple scatter gamma-rays with rare topologies. Since WIMPs will
not be tagged by the veto detector, and tags due to gamma-rays and neutrons are
separable, this population of multiple scatter events may be characterised
without biasing the analysis of candidate WIMP signals in the data.
[20]
oai:arXiv.org:1004.4207 [pdf] - 325335
The ZEPLIN-III Anti-Coincidence Veto Detector
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
Edwards, B.;
Francis, V.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Lyons, K.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Taylor, R.;
Thorne, C.;
Walker, R. J.
Submitted: 2010-04-23, last modified: 2010-04-27
The design, optimisation and construction of an anti-coincidence veto
detector to complement the ZEPLIN-III direct dark matter search instrument is
described. One tonne of plastic scintillator is arranged into 52 bars
individually read out by photomultipliers and coupled to a gadolinium-loaded
passive polypropylene shield. Particular attention has been paid to
radiological content. The overall aim has been to achieve a veto detector of
low threshold and high efficiency without the creation of additional background
in ZEPLIN-III, all at a reasonable cost. Extensive experimental measurements of
the components have been made, including radioactivity levels and performance
characteristics. These have been used to inform a complete end-to-end Monte
Carlo simulation that has then been used to calculate the expected performance
of the new instrument, both operating alone and as an anti-coincidence detector
for ZEPLIN-III. The veto device will be capable of rejecting over 65% of
coincident nuclear recoil events from neutron background in the energy range of
interest in ZEPLIN-III. This will reduce the background in ZEPLIN-III from ~0.4
to ~0.14 events per year in the WIMP acceptance region, a significant factor in
the event of a non-zero observation. Furthermore, in addition to providing
valuable diagnostic capabilities, the veto is capable of tagging over 15% for
gamma-ray rejection, all whilst contributing no significant additional
background. In conjunction with the replacement of the internal ZEPLIN-III
photomultiplier array, the new veto is expected to improve significantly the
sensitivity of the ZEPLIN-III instrument to dark matter, allowing spin
independent WIMP-nucleon cross sections below 1E-8 pb to be probed.