sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Redman, S. L.

Normalized to: Redman, S.

13 article(s) in total. 41 co-authors, from 1 to 11 common article(s). Median position in authors list is 4,0.

[1]  oai:arXiv.org:1403.6841  [pdf] - 1370150
Development of Fiber Fabry-Perot Interferometers as Stable Near-infrared Calibration Sources for High Resolution Spectrographs
Comments: 12 pages, 17 figures. Accepted in PASP
Submitted: 2014-03-26
We discuss the ongoing development of single-mode fiber Fabry-Perot (FFP) Interferometers as precise astro-photonic calibration sources for high precision radial velocity (RV) spectrographs. FFPs are simple, inexpensive, monolithic units that can yield a stable and repeatable output spectrum. An FFP is a unique alternative to a traditional etalon, as the interferometric cavity is made of single-mode fiber rather than an air-gap spacer. This design allows for excellent collimation, high spectral finesse, rigid mechanical stability, insensitivity to vibrations, and no need for vacuum operation. The device we have tested is a commercially available product from Micron Optics. Our development path is targeted towards a calibration source for the Habitable-Zone Planet Finder (HPF), a near-infrared spectrograph designed to detect terrestrial-mass planets around low-mass stars, but this reference could also be used in many existing and planned fiber-fed spectrographs as we illustrate using the Apache Point Observatory Galactic Evolution Experiment (APOGEE) instrument. With precise temperature control of the fiber etalon, we achieve a thermal stability of 100 $\mu$K and associated velocity uncertainty of 22 cm s$^{-1}$. We achieve a precision of $\approx$2 m s$^{-1}$ in a single APOGEE fiber over 12 hours using this new photonic reference after removal of systematic correlations. This high precision (close to the expected photon-limited floor) is a testament to both the excellent intrinsic wavelength stability of the fiber interferometer and the stability of the APOGEE instrument design. Overall instrument velocity precision is 80 cm s$^{-1}$ over 12 hours when averaged over all 300 APOGEE fibers and after removal of known trends and pressure correlations, implying the fiber etalon is intrinsically stable to significantly higher precision.
[2]  oai:arXiv.org:1308.5229  [pdf] - 1178752
The Spectrum of Thorium from 250 nm to 5500 nm: Ritz Wavelengths and Optimized Energy Levels
Comments: 15 pages, 8 figures, 7 tables. Revised to remove spurious lines in tables 1 and 6. Full versions of tables 1, 5, 6 and 7 uploaded as ancillary files
Submitted: 2013-08-23, last modified: 2014-01-23
We have made precise observations of a thorium-argon hollow cathode lamp emission spectrum in the region between 350 nm and 1175 nm using a high-resolution Fourier transform spectrometer. Our measurements are combined with results from seven previously published thorium line lists (Giacchetti et al. 1974; Zalubas & Corliss 1974; Zalubas 1976; Palmer & Engleman 1983; Engleman et al. 2003; Lovis & Pepe 2007; Kerber et al. 2008) to re-optimize the energy levels of neutral, singly-, and doubly-ionized thorium (Th I, Th II, and Th III). Using the optimized level values, we calculate accurate Ritz wavelengths for 19874 thorium lines between 250 nm and 5500 nm (40000 1/cm to 1800 1/cm). We have also found 102 new thorium energy levels. A systematic analysis of previous measurements in light of our new results allows us to identify and propose corrections for systematic errors in Palmer & Engleman (1983) and typographical errors and incorrect classifications in Kerber et al. (2008). We also found a large scatter in the thorium line list of Lovis & Pepe (2007). We anticipate that our Ritz wavelengths will lead to improved measurement accuracy for current and future spectrographs that make use of thorium-argon or thorium-neon lamps as calibration standards.
[3]  oai:arXiv.org:1209.3295  [pdf] - 1151415
A near infrared frequency comb for Y+J band astronomical spectroscopy
Comments: Submitted to SPIE, conference proceedings 8450
Submitted: 2012-09-14
Radial velocity (RV) surveys supported by high precision wavelength references (notably ThAr lamps and I2 cells) have successfully identified hundreds of exoplanets; however, as the search for exoplanets moves to cooler, lower mass stars, the optimum wave band for observation for these objects moves into the near infrared (NIR) and new wavelength standards are required. To address this need we are following up our successful deployment of an H band(1.45-1.7{\mu}m) laser frequency comb based wavelength reference with a comb working in the Y and J bands (0.98-1.3{\mu}m). This comb will be optimized for use with a 50,000 resolution NIR spectrograph such as the Penn State Habitable Zone Planet Finder. We present design and performance details of the current Y+J band comb.
[4]  oai:arXiv.org:1209.2906  [pdf] - 1151383
Optical fiber modal noise in the 0.8 to 1.5 micron region and implications for near infrared precision radial velocity measurements
Comments: To appear in the proceedings of the SPIE 2012 Astronomical Instrumentation and Telescopes conference
Submitted: 2012-09-13
Modal noise in fibers has been shown to limit the signal-to-noise ratio achievable in fiber-coupled, high-resolution spectrographs if it is not mitigated via modal scrambling techniques. Modal noise become significantly more important as the wavelength increases and presents a risk to the new generation of near-infrared precision radial spectrographs under construction or being proposed to search for planets around cool M-dwarf stars, which emit most of their light in the NIR. We present experimental results of tests at Penn State University characterizing modal noise in the far visible out to 1.5 microns and the degree of modal scrambling we obtained using mechanical scramblers. These efforts are part of a risk mitigation effort for the Habitable Zone Planet Finder spectrograph currently under development at Penn State University.
[5]  oai:arXiv.org:1209.2704  [pdf] - 622877
Development of a New, Precise Near-infrared Doppler Wavelength Reference: A Fiber Fabry-Perot Interferometer
Comments: 16 pages, 11 figures. To appear in the proceedings of the SPIE 2012 Astronomical Instrumentation and Telescopes conference
Submitted: 2012-09-12, last modified: 2012-09-13
We present the ongoing development of a commercially available Micron Optics fiber-Fabry Perot Interferometer as a precise, stable, easy to use, and economic spectrograph reference with the goal of achieving <1 m/s long term stability. Fiber Fabry-Perot interferometers (FFP) create interference patterns by combining light traversing different delay paths. The interference creates a rich spectrum of narrow emission lines, ideal for use as a precise Doppler reference. This fully photonic reference could easily be installed in existing NIR spectrographs, turning high resolution fiber-fed spectrographs into precise Doppler velocimeters. First light results on the Sloan Digital Sky Survey III (SDSS-III) Apache Point Observatory Galactic Evolution Experiment (APOGEE) spectrograph and several tests of major support instruments are also presented. These instruments include a SuperK Photonics fiber supercontinuum laser source and precise temperature controller. A high resolution spectrum obtained using the NIST 2-m Fourier transform spectrometer (FTS) is also presented. We find our current temperature control precision of the FFP to be 0.15 mK, corresponding to a theoretical velocity stability of 35 cm/s due to temperature variations of the interferometer cavity.
[6]  oai:arXiv.org:1209.1686  [pdf] - 1151246
The Habitable-Zone Planet Finder: A Stabilized Fiber-Fed NIR Spectrograph for the Hobby-Eberly Telescope
Comments: 14 pages, 9 figures. To appear in the proceedings of the SPIE 2012 Astronomical Instrumentation and Telescopes conference
Submitted: 2012-09-07
We present the scientific motivation and conceptual design for the recently funded Habitable-zone Planet Finder (HPF), a stabilized fiber-fed near-infrared (NIR) spectrograph for the 10 meter class Hobby-Eberly Telescope (HET) that will be capable of discovering low mass planets around M dwarfs. The HPF will cover the NIR Y & J bands to enable precise radial velocities to be obtained on mid M dwarfs, and enable the detection of low mass planets around these stars. The conceptual design is comprised of a cryostat cooled to 200K, a dual fiber-feed with a science and calibration fiber, a gold coated mosaic echelle grating, and a Teledyne Hawaii-2RG (H2RG) NIR detector with a 1.7$\mu$m cutoff. A uranium-neon hollow-cathode lamp is the baseline wavelength calibration source, and we are actively testing laser frequency combs to enable even higher radial velocity precision. We will present the overall instrument system design and integration with the HET, and discuss major system challenges, key choices, and ongoing research and development projects to mitigate risk. We also discuss the ongoing process of target selection for the HPF survey.
[7]  oai:arXiv.org:1201.5125  [pdf] - 496339
Demonstration of On-Sky Calibration of Astronomical Spectra using a 25 GHz near-IR Laser Frequency Comb
Comments: 12 pages, 7 figures
Submitted: 2012-01-23, last modified: 2012-04-04
We describe and characterize a 25 GHz laser frequency comb based on a cavity-filtered erbium fiber mode-locked laser. The comb provides a uniform array of optical frequencies spanning 1450 nm to 1700 nm, and is stabilized by use of a global positioning system referenced atomic clock. This comb was deployed at the 9.2 m Hobby-Eberly telescope at the McDonald Observatory where it was used as a radial velocity calibration source for the fiber-fed Pathfinder near-infrared spectrograph. Stellar targets were observed in three echelle orders over four nights, and radial velocity precision of \sim10 m/s (\sim6 MHz) was achieved from the comb-calibrated spectra.
[8]  oai:arXiv.org:1112.1062  [pdf] - 1092165
A High-Resolution Atlas of Uranium-Neon in the H Band
Comments: 23 pages, 7 figures, submitted and accepted in ApJSS. Online-only material to be published online by ApJSS
Submitted: 2011-12-05
We present a high-resolution (R ~ 50 000) atlas of a uranium-neon (U/Ne) hollow-cathode spectrum in the H-band (1454 nm to 1638 nm) for the calibration of near-infrared spectrographs. We obtained this U/Ne spectrum simultaneously with a laser-frequency comb spectrum, which we used to provide a first-order calibration to the U/Ne spectrum. We then calibrated the U/Ne spectrum using the recently-published uranium line list of Redman et al. (2011), which is derived from high-resolution Fourier transform spectrometer measurements. These two independent calibrations allowed us to easily identify emission lines in the hollow cathode lamp that do not correspond to known (classified) lines of either uranium or neon, and to compare the achievable precision of each source. Our frequency comb precision was limited by modal noise and detector effects, while the U/Ne precision was limited primarily by the signal-to-noise ratio (S/N) of the observed emission lines and our ability to model blended lines. The standard deviation in the dispersion solution residuals from the S/N-limited U/Ne hollow cathode lamp were 50% larger than the standard deviation of the dispersion solution residuals from the modal-noise-limited laser frequency comb. We advocate the use of U/Ne lamps for precision calibration of near-infrared spectrographs, and this H-band atlas makes these lamps significantly easier to use for wavelength calibration.
[9]  oai:arXiv.org:1107.4091  [pdf] - 447605
The Infrared Spectrum of Uranium Hollow Cathode Lamps from 850 nm to 4000 nm: Wavenumbers and Line Identifications from Fourier Transform Spectra
Comments: 23 pages, 6 Figures
Submitted: 2011-07-20
We provide new measurements of wavenumbers and line identifications of 10 100 UI and UII near-infrared (NIR) emission lines between 2500 cm-1 and 12 000 cm-1 (4000 nm to 850 nm) using archival FTS spectra from the National Solar Observatory (NSO). This line list includes isolated uranium lines in the Y, J, H, K, and L bands (0.9 {\mu}m to 1.1 {\mu}m, 1.2 {\mu}m to 1.35 {\mu}m, 1.5 {\mu}m to 1.65 {\mu}m, 2.0 {\mu}m to 2.4 {\mu}m, and 3.0 {\mu}m to 4.0 {\mu}m, respectively), and provides six times as many calibration lines as thorium in the NIR spectral range. The line lists we provide enable inexpensive, commercially-available uranium hollow-cathode lamps to be used for high-precision wavelength calibration of existing and future high-resolution NIR spectrographs.
[10]  oai:arXiv.org:1009.0477  [pdf] - 1034656
The Pathfinder Testbed: Exploring Techniques for Achieving Precision Radial Velocities in the Near-Infrared
Comments: To appear in Proc. SPIE 2010 Vol. 7735
Submitted: 2010-09-02
The Penn State Pathfinder is a prototype warm fiber-fed Echelle spectrograph with a Hawaii-1 NIR detector that has already demonstrated 7-10 m/s radial velocity precision on integrated sunlight. The Pathfinder testbed was initially setup for the Gemini PRVS design study to enable a systematic exploration of the challenges of achieving high radial velocity precision in the near-infrared, as well as to test possible solutions to these calibration challenges. The current version of the Pathfinder has an R3 echelle grating, and delivers a resolution of R~50,000 in the Y, J or H bands of the spectrum. We will discuss the on sky-performance of the Pathfinder during an engineering test run at the Hobby Eberly Telescope as well the results of velocity observations of M dwarfs. We will also discuss the unique calibration techniques we have explored, like Uranium-Neon hollow cathode lamps, notch filter, and modal noise mitigation to enable high precision radial velocity observation in the NIR. The Pathfinder is a prototype testbed precursor of a cooled high-resolution NIR spectrograph capable of high radial velocity precision and of finding low mass planets around mid-late M dwarfs.
[11]  oai:arXiv.org:1007.3235  [pdf] - 1033765
The Habitable Zone Planet Finder: A Proposed High Resolution NIR Spectrograph for the Hobby Eberly Telescope to Discover Low Mass Exoplanets around M Dwarfs
Comments: 11 pages, 8 figures, to appear in Proc. SPIE 2010 Vol. 7735
Submitted: 2010-07-19
The Habitable Zone Planet Finder (HZPF) is a proposed instrument for the 10m class Hobby Eberly telescope that will be capable of discovering low mass planets around M dwarfs. HZPF will be fiber-fed, provide a spectral resolution R~ 50,000 and cover the wavelength range 0.9-1.65{\mu}m, the Y, J and H NIR bands where most of the flux is emitted by mid-late type M stars, and where most of the radial velocity information is concentrated. Enclosed in a chilled vacuum vessel with active temperature control, fiber scrambling and mechanical agitation, HZPF is designed to achieve a radial velocity precision < 3m/s, with a desire to obtain <1m/s for the brightest targets. This instrument will enable a study of the properties of low mass planets around M dwarfs; discover planets in the habitable zones around these stars, as well serve as an essential radial velocity confirmation tool for astrometric and transit detections around late M dwarfs. Radial velocity observation in the near-infrared (NIR) will also enable a search for close in planets around young active stars, complementing the search space enabled by upcoming high-contrast imaging instruments like GPI, SPHERE and PALM3K. Tests with a prototype Pathfinder instrument have already demonstrated the ability to recover radial velocities at 7-10 m/s precision from integrated sunlight and ~15-20 m/s precision on stellar observations at the HET. These tests have also demonstrated the ability to work in the NIR Y and J bands with an un-cooled instrument. We will also discuss lessons learned about calibration and performance from our tests and how they impact the overall design of the HZPF.
[12]  oai:arXiv.org:0806.3749  [pdf] - 13812
A Pathfinder Instrument for Precision Radial Velocities in the Near-Infrared
Comments: 18 pages, 8 figures, accepted for publication in PASP
Submitted: 2008-06-23
We have designed and tested an in-plane echelle spectrograph configured to investigate precision radial velocities from ground-based near-infrared observations. The spectrograph operates across the spectral range of 0.9-1.7 mm at a spectral resolution of R = 50,000, and uses a liquid nitrogen-cooled HAWAII 1K detector. Repeated measurements of the Earth's rotation via integrated Sunlight with two different instrument arrangements in the near infrared Y band have produced radial velocities with ~10 m/s RMS over a period of several hours. The most recent instrument configuration has achieved an unbinned RMS of 7 m/s and suggests that infrared radial velocity precisions may be able to approach those achieved at optical wavelengths.
[13]  oai:arXiv.org:astro-ph/0407540  [pdf] - 66382
PSR 2303+30: A single system of drifting subpulses, moding and nulling
Comments: 15 pages. 19 figures, submitted to MNRAS
Submitted: 2004-07-26, last modified: 2004-07-28
Analyses of multiple pulse sequences of B2303+30 reveal that this pulsar has two distinct emission modes. One mode (B) follows a steady even-odd pattern and is more intense. The second mode (Q) is characteristically weak, but has intermittent driftbands with a periodicity of approximately 3 P/cycles, and nulls much more frequently than the B mode. Both modes occur with roughly equal frequency and their profiles have a similar single-humped form with a slight asymmetry. Our observations and analyses strongly suggest that the subpulse driftrates in both modes are linked in a series of cycles, which can be modelled as relaxing oscillations in the underlying circulation rate.