Normalized to: Redfern, M.
[1]
oai:arXiv.org:1511.07641 [pdf] - 1347680
A recent change in the optical and {\gamma}-ray polarization of the Crab
nebula and pulsar
Submitted: 2015-11-24
We report on observations of the polarization of optical and {\gamma}-ray
photons from the Crab nebula and pulsar system using the Galway Astronomical
Stokes Polarimeter (GASP), the Hubble Space Telescope/Advanced Camera for
Surveys (HST/ACS) and the International Gamma-Ray Astrophysics Laboratory
satellite (Integral). These, when combined with other optical polarization
observations, suggest that the polarized optical emission and {\gamma}-ray
polarization changes in a similar manner. A change in the optical polarization
angle has been observed by this work, from 109.5 \pm 0.7\deg in 2005 to 85.3
\pm 1.4 \deg in 2012. On the other hand, the {\gamma}-ray polarization angle
changed from 115 \pm 11 \deg in 2003-2007 to 80 \pm 12 \deg in 2012-2014.
Strong flaring activities have been detected in the Crab nebula over the past
few years by the high energy {\gamma}-ray missions Agile and Fermi, and
magnetic reconnection processes have been suggested to explain these
observations. The change in the polarized optical and {\gamma}-ray emission of
the Crab nebula/pulsar as observed, for the first time, by GASP and Integral
may indicate that reconnection is possibly at work in the Crab nebula. We also
report, for the first time, a non-zero measure of the optical circular
polarization from the Crab pulsar+knot system.
[2]
oai:arXiv.org:1509.05270 [pdf] - 1278881
An investigation of the Eigenvalue Calibration Method (ECM) using GASP
for non-imaging and imaging detectors
Submitted: 2015-09-17
Polarised light from astronomical targets can yield a wealth of information
about their source radiation mechanisms, and about the geometry of the
scattered light regions. Optical observations, of both the linear and circular
polarisation components, have been impeded due to non-optimised
instrumentation. The need for suitable observing conditions and the
availability of luminous targets are also limiting factors. GASP uses division
of amplitude polarimeter (DOAP) (Compain and Drevillon) to measure the four
components of the Stokes vector simultaneously, which eliminates the
constraints placed upon the need for moving parts during observation, and
offers a real-time complete measurement of polarisation. Results from the GASP
calibration are presented in this work for both a 1D detector system, and a
pixel-by-pixel analysis on a 2D detector system. Following Compain et al. we
use the Eigenvalue Calibration Method (ECM) to measure the polarimetric
limitations of the instrument for each of the two systems. Consequently, the
ECM is able to compensate for systematic errors introduced by the calibration
optics, and it also accounts for all optical elements of the polarimeter in the
output. Initial laboratory results of the ECM are presented, using APD
detectors, where errors of 0.2% and 0.1{\deg} were measured for the degree of
linear polarisation and polarisation angle respectively. Channel-to-channel
image registration is an important aspect of 2-D polarimetry. We present our
calibration results of the measured Mueller matrix of each sample, used by the
ECM. A set of Zenith flat-field images were recorded during an observing
campaign at the Palomar 200 inch telescope in November 2012. From these we show
the polarimetric errors from the spatial polarimetry indicating both the
stability and absolute accuracy of GASP.
[3]
oai:arXiv.org:1305.6825 [pdf] - 1171658
The Galway Astronomical Stokes Polarimeter: An All-Stokes Optical
Polarimeter with Ultra-High Time Resolution
Submitted: 2013-05-29
Many astronomical objects emit polarised light, which can give information
both about their source mechanisms, and about (scattering) geometry in their
source regions. To date (mostly) only the linearly polarised components of the
emission have been observed in stellar sources. Observations have been
constrained because of instrumental considerations to periods of excellent
observing conditions, and to steady, slowly or periodically-varying sources.
This leaves a whole range of interesting objects beyond the range of
observation at present. The Galway Astronomical Stokes Polarimeter (GASP) has
been developed to enable us to make observations on these very sources. GASP
measures the four components of the Stokes Vector simultaneously over a broad
wavelength range 400-800nm., with a time resolution of order microseconds given
suitable detectors and a bright source - this is possible because the optical
design contains no moving or modulating components. The initial design of GASP
is presented and we include some preliminary observational results
demonstrating that components of the Stokes vector can be measured to <1% in
conditions of poor atmospheric stability. Issues of efficiency and stability
are addressed. An analysis of suitable astronomical targets, demanding the
unique properties of GASP, is also presented.
[4]
oai:arXiv.org:0905.0084 [pdf] - 23852
GASP - Galway Astronomical Stokes Polarimeter
Submitted: 2009-05-01
The Galway Astronomical Stokes Polarimeter (GASP) is an ultra-high-speed,
full Stokes, astronomical imaging polarimeter based upon a Division of
Amplitude Polarimeter. It has been developed to resolve extremely rapid
stochastic, millisecond variations in objects such as optical pulsars, RRATs
and magnetic cataclysmic variables. GASP has no moving parts or modulated
components, so the complete Stokes vector can be measured from just one
exposure - making it unique to astronomy. Furthermore the time required for the
determination of the full Stokes vector is limited only by the time resolution
of the detectors used and the incident photon fluxes. GASP utilizes a modified
Fresnel rhomb, which acts as a highly achromatic quarter wave plate and a
beamsplitter (referred to as an RBS). Here we present a description of how the
DOAP works, some of the optical designs for the polarimeter, and give some
preliminary results. Calibration is an important, and difficult issue with all
polarimeters, but particularly in astronomical polarimeters. We give a
description of calibration techniques appropriate to this type of polarimeter,
particularly the Eigenvalue Calibration Method of Compain & Drevillon
[5]
oai:arXiv.org:astro-ph/0609261 [pdf] - 84853
Short time scale pulse stability of the Crab pulsar in the optical band
Submitted: 2006-09-09
The fine structure and the variations of the optical pulse shape and phase of
the Crab pulsar are studied on various time scales. The observations have been
carried out on 4-m William Hershel and 6-m BTA telescopes with APD photon
counter, photomultiplier based 4-channel photometer and PSD based panoramic
spectrophotopolarimeter with 1$\mu$s time resolution in 1994, 1999, 2003 and
2005-2006 years. The upper limit on the pulsar precession on Dec 2, 1999 is
placed in the 10 s - 2 hours time range. The evidence of a varying from set to
set fine structure of the main pulse is found in the 1999 and 2003 years data.
No such fine structure is detected in the integral pulse shape of 1994, 1999
and 2003 years.
The drastic change of the pulse shape in the 2005-2006 years set is detected
along with the pulse shape variability and quasi-periodic phase shifts.
[6]
oai:arXiv.org:astro-ph/0308271 [pdf] - 58550
Enhanced Optical Emission During Crab Giant Radio Pulses
Submitted: 2003-08-15
We detected a correlation between optical and giant radio pulse emission from
the Crab pulsar. Optical pulses coincident with the giant radio pulses were on
average 3% brighter than those coincident with normal radio pulses. Combined
with the lack of any other pulse profile changes, this result indicates that
both the giant radio pulses and the increased optical emission are linked to an
increase in the electron-positron plasma density.
[7]
oai:arXiv.org:astro-ph/0212478 [pdf] - 53868
A new survey of variability in the core of M15 with TRIFFID-2
Submitted: 2002-12-20
A two-week campaign of high-resolution imaging of the centre of M15 using the
tip/tilt correcting TRIFFID-2 camera, followed by analysis with ISIS (image
matching & subtraction software), has produced the most sensitive survey to
date of variable stars in the central ~1x1 arcmin^2 - a total of 48 were
detected -, and constrains the size of the dwarf nova population.
[8]
oai:arXiv.org:astro-ph/0010044 [pdf] - 38392
A 2.14 ms Candidate Optical Pulsar in SN1987A
Middleditch, J.;
Kristian, J. A.;
Kunkel, W. E.;
Hill, K. M.;
Watson, R. M.;
Luicio, R.;
Imamura, J. N.;
Steiman-Cameron, T. Y.;
Shearer, A.;
Redfern, M.;
Butler, R.;
Danks, A. C.;
.
Submitted: 2000-10-02, last modified: 2000-10-11
We have monitored Supernova 1987A in optical/near-infrared bands from a few
weeks following its birth until the present time in order to search for a
pulsar remnant. We have found an apparent pattern of emission near the
frequency of 467.5 Hz - a 2.14 ms pulsar candidate, first detected in data
taken on the remnant at the Las Campanas Observatory (LCO) 2.5-m Dupont
telescope during 14-16 Feb. 1992 UT. We detected further signals near the 2.14
ms period on numerous occasions over the next four years in data taken with a
variety of telescopes, data systems and detectors, at a number of ground- and
space-based observatories. The sequence of detections of this signal from Feb.
`92 through August `93, prior to its apparent subsequent fading, is highly
improbable (< 1.e-10) for any noise source). We also find evidence for
modulation of the 2.14 ms period with a ~1,000 s period which, when taken with
the high spindown of the source (2-3e-10 Hz/s), is consistent with precession
and spindown via gravitational radiation of a neutron star with a
non-axisymmetric oblateness of ~1e-6, and an implied gravitational luminosity
exceeding that of the Crab Nebula pulsar by an order of magnitude.
[9]
oai:arXiv.org:astro-ph/9803109 [pdf] - 100644
A Search for the Optical Counterpart of PSR B1951+32 in the Supernova
Remnant CTB 80
O'Sullivan, Creidhe;
Shearer, A.;
Colhoun, M.;
Golden, A.;
Redfern, M.;
Butler, R.;
Beskin, G. M.;
Neizvestny, S. I.;
Neustroev, V. V.;
Plokhotnichenko, V. L.;
Danks, A.
Submitted: 1998-03-10, last modified: 1998-03-12
Using time-resolved two-dimensional aperture photometry we have put upper
limits on the pulsed emission from two proposed optical counterparts for PSR
B1951+32. Our pulsed upper limits of m_{vpulsed}>23.3, m_{bpulsed}>24.4$, for
the first candidate and m_{vpulsed}>23.6$, m_{bpulsed}>24.3 for the second,
make it unlikely that either of these is, in fact, the pulsar. We discuss three
further candidates, but also reject these on the basis of timing results. A
search of a 5.5arcs x 5.5arcs area centred close to these stars failed to find
any significant pulsations at the reported pulsar period.
[10]
oai:arXiv.org:astro-ph/9803107 [pdf] - 100642
Time-Resolved Optical Observations of PSR 1509-58
Submitted: 1998-03-10
Using time resolved 2-dimensional aperture photometry we have established
that the optical candidate for PSR 1509-58 does not pulse. Our pulsed upper
limits (m_V = 24.3 and m_B = 25.7) put severe constraints on this being the
optical counterpart. Furthermore the colours of the candidate star are
consistent with a main sequence star at a distance of 2-4 kpc. The probability
of a chance coincidence with a normal star and the difficulty of explaining the
lack of pulsed emission leads us to conclude that this object is an
intermediate field star.