Normalized to: Reddy, L.
[1]
oai:arXiv.org:2005.00994 [pdf] - 2088316
Energy sensitivity of the GRAPES-3 EAS array for primary cosmic ray
protons
Hariharan, B.;
Ahmad, S.;
Chakraborty, M.;
Chandra, A.;
Dugad, S. R.;
Gupta, S. K.;
Hayashi, Y.;
Kojima, H.;
Inbanathan, S. S. R.;
Jagadeesan, P.;
Jain, A.;
Jain, P.;
Jhansi, V. B.;
Kawakami, S.;
Mohanty, P. K.;
Morris, S. D.;
Nayak, P. K.;
Oshima, A.;
Pattanaik, D.;
Rakshe, P. S.;
Ramesh, K.;
Rao, B. S.;
Reddy, L. V.;
Shibata, S.;
Varsi, F.;
Zuberi, M.
Submitted: 2020-05-03
Low energy ground-based cosmic ray air shower experiments generally have
energy threshold in the range of a few tens to a few hundreds of TeV. The
shower observables are measured indirectly with an array of detectors. The
atmospheric absorption of low energy secondaries limits their detection
frequencies at the Earth's surface. However, due to selection effects, a tiny
fraction of low energy showers, which are produced in the lower atmosphere can
reach the observational level. But, due to less information of shower
observables, the reconstruction of these showers are arduous. Hence, it is
believed that direct measurements by experiments aboard on satellites and
balloon flights are more reliable at low energies. Despite having very small
efficiency ($\sim$0.1%) at low energies, the large acceptance ($\sim$5 m$^2$sr)
of GRAPES-3 experiment allows observing primary cosmic rays down below to
$\sim$1 TeV and opens up the possibility to measure primary energy spectrum
spanning from a few TeV to beyond cosmic ray knee (up to 10$^{16}$ eV),
covering five orders of magnitude. The GRAPES-3 energy threshold for primary
protons through Monte Carlo simulations are calculated, which gives reasonably
good agreement with data. Furthermore, the total efficiencies and acceptance
are also calculated for protons primaries. The ability of GRAPES-3 experiment
to cover such a broader energy range may provide a unique handle to bridge the
energy spectrum between direct measurements at low energies and indirect
measurements at ultra-high energies.
[2]
oai:arXiv.org:1911.04715 [pdf] - 1996827
The angular resolution of GRAPES-3 EAS array after correction for the
shower front curvature
Jhansi, V. B.;
Ahmad, S.;
Chakraborty, M.;
Dugad, S. R.;
Gupta, S. K.;
Hariharan, B.;
Hayashi, Y.;
Jagadeesan, P.;
Jain, A.;
Jain, P.;
Kawakami, S.;
Kojima, H.;
Mahapatra, S.;
Mohanty, P. K.;
Morris, S. D.;
Nayak, P. K.;
Oshima, A.;
Pattanaik, D.;
Rakshe, P. S.;
Ramesh, K.;
Rao, B. S.;
Reddy, L. V.;
Shibata, S.;
Varsi, F.;
Zuberi, M.
Submitted: 2019-11-12
The angular resolution of an extensive air shower (EAS) array plays a
critical role in determining its sensitivity for the detection of point
$\gamma$-ray sources in the multi-TeV energy range. The GRAPES-3 an EAS array
located at Ooty in India (11.4$^{\circ}$N, 76.7$^{\circ}$E, 2200 m altitude) is
designed to study $\gamma$-rays in the TeV-PeV energy range. It comprises of a
dense array of 400 plastic scintillators deployed over an area of 25000 m$^2$
and a large area (560 m$^2$) muon telescope. A new statistical method allowed
real time determination of the propagation delay of each detector in the
GRAPES-3 array. The shape of shower front is known to be curved and here the
details of a new method developed for accurate measurement of the shower front
curvature is presented. These two developments have led to a sizable
improvement in the angular resolution of GRAPES-3 array. It is shown that the
curvature depends on the size and age of an EAS. By employing two different
techniques, namely, the odd-even and the left-right methods, independent
estimates of the angular resolution are obtained. The odd-even method estimates
the best achievable resolution of the array. For obtaining the angular
resolution, the left-right method is used after implementing the size and age
dependent curvature corrections. A comparison of the angular resolution as a
function of EAS energy by these two methods shows them be virtually
indistinguishable. The angular resolution of GRAPES-3 array is 47$^{\prime}$
for energies E$>$5 TeV and improves to 17$^{\prime}$ at E$>$100 TeV and finally
approaching 10$^{\prime}$ at E$>$500 TeV.