Normalized to: Reck, T.
[1]
oai:arXiv.org:1511.04488 [pdf] - 1347622
Low Noise Titanium Nitride KIDs for SuperSpec: A Millimeter-Wave On-Chip
Spectrometer
Hailey-Dunsheath, S.;
Shirokoff, E.;
Barry, P. S.;
Bradford, C. M.;
Chapman, S.;
Che, G.;
Glenn, J.;
Hollister, M.;
Kovács, A.;
LeDuc, H. G.;
Mauskopf, P.;
McKenney, C.;
O'Brient, R.;
Padin, S.;
Reck, T.;
Shiu, C.;
Tucker, C. E.;
Wheeler, J.;
Williamson, R.;
Zmuidzinas, J.
Submitted: 2015-11-13
SuperSpec is a novel on-chip spectrometer we are developing for multi-object,
moderate resolution (R = 100 - 500), large bandwidth (~1.65:1) submillimeter
and millimeter survey spectroscopy of high-redshift galaxies. The spectrometer
employs a filter bank architecture, and consists of a series of half-wave
resonators formed by lithographically-patterned superconducting transmission
lines. The signal power admitted by each resonator is detected by a lumped
element titanium nitride (TiN) kinetic inductance detector (KID) operating at
100 - 200 MHz. We have tested a new prototype device that achieves the targeted
R = 100 resolving power, and has better detector sensitivity and optical
efficiency than previous devices. We employ a new method for measuring photon
noise using both coherent and thermal sources of radiation to cleanly separate
the contributions of shot and wave noise. We report an upper limit to the
detector NEP of $1.4\times10^{-17}$ W Hz$^{-1/2}$, within 10% of the photon
noise limited NEP for a ground-based R=100 spectrometer.
[2]
oai:arXiv.org:1501.02295 [pdf] - 1223953
Status of SuperSpec: A Broadband, On-Chip Millimeter-Wave Spectrometer
Hailey-Dunsheath, S.;
Shirokoff, E.;
Barry, P. S.;
Bradford, C. M.;
Chattopadhyay, G.;
Day, P.;
Doyle, S.;
Hollister, M.;
Kovacs, A.;
LeDuc, H. G.;
Mauskopf, P.;
McKenney, C. M.;
Monroe, R.;
O'Brient, R.;
Padin, S.;
Reck, T.;
Swenson, L.;
Tucker, C. E.;
Zmuidzinas, J.
Submitted: 2015-01-09
SuperSpec is a novel on-chip spectrometer we are developing for multi-object,
moderate resolution (R = 100 - 500), large bandwidth (~1.65:1) submillimeter
and millimeter survey spectroscopy of high-redshift galaxies. The spectrometer
employs a filter bank architecture, and consists of a series of half-wave
resonators formed by lithographically-patterned superconducting transmission
lines. The signal power admitted by each resonator is detected by a lumped
element titanium nitride (TiN) kinetic inductance detector (KID) operating at
100-200 MHz. We have tested a new prototype device that is more sensitive than
previous devices, and easier to fabricate. We present a characterization of a
representative R=282 channel at f = 236 GHz, including measurements of the
spectrometer detection efficiency, the detector responsivity over a large range
of optical loading, and the full system optical efficiency. We outline future
improvements to the current system that we expect will enable construction of a
photon-noise-limited R=100 filter bank, appropriate for a line intensity
mapping experiment targeting the [CII] 158 micron transition during the Epoch
of Reionization
[3]
oai:arXiv.org:1411.1118 [pdf] - 915510
Normal Metal Hot-Electron Nanobolometer with Johnson Noise Thermometry
Readout
Submitted: 2014-11-04
The sensitivity of a THz hot-electron nanobolometer (nano-HEB) made from a
normal metal is analyzed. Johnson Noise Thermometry (JNT) is employed as a
readout technique. In contrast to its superconducting TES counterpart, the
normal-metal nano-HEB can operate at any cryogenic temperature depending on the
required radiation background limited Noise Equivalent Power (NEP). It does not
require bias lines; 100s of nano-HEBs can be read by a single low-noise X-band
amplifier via a filter bank channelizer. The modeling predicts that even with
the sensitivity penalty due to the amplifier noise, an NEP ~ 10$^{-20}$ -
10$^{-19}$ W/Hz$^{1/2}$ can be expected at 50-100 mK in 10-20 nm thin titanium
(Ti) normal metal HEBs with niobium (Nb) contacts. This NEP is fairly constant
over a range of readout frequencies ~ 10 GHz. Although materials with weaker
electron-phonon coupling (bismuth, graphene) do not improve the minimum
achievable NEP, they can be considered if a larger than 10 GHz readout
bandwidth is required.
[4]
oai:arXiv.org:1211.1652 [pdf] - 587352
MKID development for SuperSpec: an on-chip, mm-wave, filter-bank
spectrometer
Shirokoff, Erik;
Barry, Peter S.;
Bradford, Charles M.;
Chattopadhyay, Goutam;
Day, Peter;
Doyle, Simon;
Hailey-Dunsheath, Steve;
Hollister, Matthew I.;
Kovács, Attila;
McKenney, Christopher;
Leduc, Henry G.;
Llombart, Nuria;
Marrone, Daniel P.;
Mauskopf, Philip;
O'Brient, Roger;
Padin, Stephen;
Reck, Theodore;
Swenson, Loren J.;
Zmuidzinas, Jonas
Submitted: 2012-11-07
SuperSpec is an ultra-compact spectrometer-on-a-chip for millimeter and
submillimeter wavelength astronomy. Its very small size, wide spectral
bandwidth, and highly multiplexed readout will enable construction of powerful
multibeam spectrometers for high-redshift observations. The spectrometer
consists of a horn-coupled microstrip feedline, a bank of narrow-band
superconducting resonator filters that provide spectral selectivity, and
Kinetic Inductance Detectors (KIDs) that detect the power admitted by each
filter resonator. The design is realized using thin-film lithographic
structures on a silicon wafer. The mm-wave microstrip feedline and spectral
filters of the first prototype are designed to operate in the band from 195-310
GHz and are fabricated from niobium with at Tc of 9.2K. The KIDs are designed
to operate at hundreds of MHz and are fabricated from titanium nitride with a
Tc of 2K. Radiation incident on the horn travels along the mm-wave microstrip,
passes through the frequency-selective filter, and is finally absorbed by the
corresponding KID where it causes a measurable shift in the resonant frequency.
In this proceedings, we present the design of the KIDs employed in SuperSpec
and the results of initial laboratory testing of a prototype device. We will
also briefly describe the ongoing development of a demonstration instrument
that will consist of two 500-channel, R=700 spectrometers, one operating in the
1-mm atmospheric window and the other covering the 650 and 850 micron bands.