Ravensberg, Kevin
Normalized to: Ravensberg, K.
2 article(s) in total. 16 co-authors, from 1 to 2 common article(s). Median position in authors list is 8,0.
[1]
oai:arXiv.org:2003.11899 [pdf] - 2070581
Progress in the development of frequency domain multiplexing for the
X-ray Integral Field Unit on board the Athena mission
Akamatsu, H.;
Gottardi, L.;
van der Kuur, J.;
de Vries, C. P.;
Bruijn, M. P.;
Chervenak, J. A.;
Kiviranta, M.;
Linden, A. J. van den;
Jackson, B. D.;
Miniussi, A.;
Ravensberg, K.;
Sakai, K.;
Smith, S. J.;
Wakeham, N.
Submitted: 2020-03-26
Frequency domain multiplexing (FDM) is the baseline readout system for the
X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM
scheme, TESs are coupled to a passive LC filter and biased with alternating
current (AC bias) at MHz frequencies. Using high-quality factor LC filters and
room temperature electronics developed at SRON and low-noise two-stage SQUID
amplifiers provided by VTT, we have recently demonstrated good performance with
the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have
achieved a performance requested for the demonstration model (DM) with the
single pixel AC bias ($\Delta E=$1.8 eV) and 9 pixel multiplexing ($\Delta
E=$2.6 eV) modes. We have also demonstrated 14-pixel multiplexing with an
average energy resolution of 3.3 eV, which is limited by non-fundamental issues
related to FDM readout in our lab setup.
[2]
oai:arXiv.org:1611.00956 [pdf] - 1521434
Development of frequency domain multiplexing for the X-ray Integral
Field Unit (X-IFU) on the Athena
Akamatsu, Hiroki;
Gottardi, Luciano;
van der Kuur, Jan;
de Vries, Cor P.;
Ravensberg, Kevin;
Adams, Joseph S.;
Bandler, Simon R.;
Bruijn, Marcel P.;
Chervenak, James A.;
Kilbourne, Caroline A;
Kiviranta, Mikko;
Linden, A. J. van den;
Jackson, Brian D.;
Smith, Stephen J.
Submitted: 2016-11-03
We are developing the frequency domain multiplexing (FDM) read-out of
transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field
Unit (X-IFU) instrument on board of the future European X-Ray observatory
Athena. The X-IFU instrument consists of an array of $\sim$3840 TESs with a
high quantum efficiency ($>$90 \%) and spectral resolution $\Delta E$=2.5 eV
$@$ 7 keV ($E/\Delta E\sim$2800). FDM is currently the baseline readout system
for the X-IFU instrument. Using high quality factor LC filters and room
temperature electronics developed at SRON and low-noise two stage SQUID
amplifiers provided by VTT, we have recently demonstrated good performance with
the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. An integrated
noise equivalent power resolution of about 2.0 eV at 1.7 MHz has been
demonstrated with a pixel from a new TES array from NASA/Goddard (GSFC-A2). We
have achieved X-ray energy resolutions $\sim$2.5 eV at AC bias frequency at 1.7
MHz in the single pixel read-out. We have also demonstrated for the first time
an X-ray energy resolution around 3.0 eV in a 6 pixel FDM read-out with TES
array (GSFC-A1). In this paper we report on the single pixel performance of
these microcalorimeters under MHz AC bias, and further results of the
performance of these pixels under FDM.