Normalized to: Raselli, G.
[1]
oai:arXiv.org:1108.5584 [pdf] - 1083670
Demonstration and Comparison of Operation of Photomultiplier Tubes at
Liquid Argon Temperature
Acciarri, R.;
Antonello, M.;
Boffelli, F.;
Cambiaghi, M.;
Canci, N.;
Cavanna, F.;
Cocco, A. G.;
Deniskina, N.;
Di Pompeo, F.;
Fiorillo, G.;
Galbiati, C.;
Grandi, L.;
Kryczynski, P.;
Meng, G.;
Montanari, C.;
Palamara, O.;
Pandola, L.;
Perfetto, F.;
Mortari, G. B. Piano;
Pietropaolo, F.;
Raselli, G. L.;
Rossella, M.;
Rubbia, C.;
Segreto, E.;
Szelc, A. M.;
Triossi, A.;
Ventura, S.;
Vignoli, C.;
Zani, A.
Submitted: 2011-08-29, last modified: 2011-09-26
Liquified noble gases are widely used as a target in direct Dark Matter
searches. Signals from scintillation in the liquid, following energy deposition
from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should
be recorded down to very low energies by photosensors suitably designed to
operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter
searches currently implement photo multiplier tubes for signal read-out. In the
last few years PMTs with photocathodes operating down to liquid Argon
temperatures (87 K) have been specially developed with increasing Quantum
Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod.
R11065 with peak QE up to about 35%, has been extensively tested within the R&D
program of the WArP Collaboration. During these testes the Hamamatsu PMTs
showed superb performance and allowed obtaining a light yield around 7
phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12%
range, sufficient for detection of events down to few keVee of energy
deposition. This shows that this new type of PMT is suited for experimental
applications, in particular for new direct Dark Matter searches with LAr-based
experiments.
[2]
oai:arXiv.org:astro-ph/0701286 [pdf] - 88415
First results from a Dark Matter search with liquid Argon at 87 K in the
Gran Sasso Underground Laboratory
Benetti, P.;
Acciarri, R.;
Adamo, F.;
Baibussinov, B.;
Baldo-Ceolin, M.;
Belluco, M.;
Calaprice, F.;
Calligarich, E.;
Cambiaghi, M.;
Carbonara, F.;
Cavanna, F.;
Centro, S.;
Cocco, A. G.;
Di Pompeo, F.;
Ferrari, N.;
Fiorillo, G.;
Galbiati, C.;
Gallo, V.;
Grandi, L.;
Ianni, A.;
Mangano, G.;
Meng, G.;
Montanari, C.;
Palamara, O.;
Pandola, L.;
Pietropaolo, F.;
Raselli, G. L.;
Rossella, M.;
Rubbia, C.;
Szelc, A. M.;
Ventura, S.;
Vignoli, C.
Submitted: 2007-01-10, last modified: 2007-01-16
A new method of searching for dark matter in the form of weakly interacting
massive particles (WIMP) has been developed with the direct detection of the
low energy nuclear recoils observed in a massive target (ultimately many tons)
of ultra pure Liquid Argon at 87 K. A high selectivity for Argon recoils is
achieved by the simultaneous observation of both the VUV scintillation
luminescence and of the electron signal surviving columnar recombination,
extracted through the liquid-gas boundary by an electric field. First physics
results from this method are reported, based on a small 2.3 litre test chamber
filled with natural Argon and an accumulated fiducial exposure of about 100 kg
x day, supporting the future validity of this method with isotopically purified
40Ar and for a much larger unit presently under construction with
correspondingly increased sensitivities.
[3]
oai:arXiv.org:astro-ph/0603131 [pdf] - 80340
Measurement of the specific activity of Ar-39 in natural argon
Benetti, P.;
Calaprice, F.;
Calligarich, E.;
Cambiaghi, M.;
Carbonara, F.;
Cavanna, F.;
Cocco, A. G.;
Di Pompeo, F.;
Ferrari, N.;
Fiorillo, G.;
Galbiati, C.;
Grandi, L.;
Mangano, G.;
Montanari, C.;
Pandola, L.;
Rappoldi, A.;
Raselli, G. L.;
Roncadelli, M.;
Rossella, M.;
Rubbia, C.;
Santorelli, R.;
Szelc, A. M.;
Vignoli, C.;
Zhao, Y.
Submitted: 2006-03-06, last modified: 2007-01-10
We report on the measurement of the specific activity of Ar-39 in natural
argon. The measurement was performed with a 2.3-liter two-phase (liquid and
gas) argon drift chamber. The detector was developed by the WARP Collaboration
as a prototype detector for WIMP Dark Matter searches with argon as a target.
The detector was operated for more than two years at Laboratori Nazionali del
Gran Sasso, Italy, at a depth of 3,400 m w.e. The specific activity measured
for Ar-39 is 1.01 +/- 0.02(stat) +/- 0.08(syst) Bq per kg of natural Ar.
[4]
oai:arXiv.org:astro-ph/0411491 [pdf] - 1507895
WARP: a WIMP double phase Argon detector
Brunetti, R.;
Calligarich, E.;
Cambiaghi, M.;
Carbonara, F.;
Cavanna, F.;
Cocco, A.;
De Vecchi, C.;
Dolfini, R.;
Ereditato, A.;
Ferrari, N.;
Fiorillo, G.;
Grandi, L.;
Mangano, G.;
Menegolli, A.;
Montanari, C.;
Palamara, O.;
Prata, M.;
Rappoldi, A.;
Raselli, G. L.;
Roncadelli, M.;
Rossella, M.;
Rubbia, C.;
Santorelli, R.;
Vignoli, C.
Submitted: 2004-11-17
The WARP programme for dark matter search with a double phase argon detector
is presented. In such a detector both excitation and ionization produced by an
impinging particle are evaluated by the contemporary measurement of primary
scintillation and secondary (proportional) light signal, this latter being
produced by extracting and accelerating ionization electrons in the gas phase.
The proposed technique, verified on a 2.3 liters prototype, could be used to
efficiently discriminate nuclear recoils, induced by WIMP's interactions, and
measure their energy spectrum. An overview of the 2.3 liters results and of the
proposed 100 liters detector is shown.
[5]
oai:arXiv.org:astro-ph/0405342 [pdf] - 64862
WARP liquid argon detector for dark matter survey
Brunetti, R.;
Calligarich, E.;
Cambiaghi, M.;
Carbonara, F.;
Cocco, A.;
De Vecchi, C.;
Dolfini, R.;
Ereditato, A.;
Fiorillo, G.;
Grandi, L.;
Mangano, G.;
Menegolli, A.;
Montanari, C.;
Prata, M.;
Rappoldi, A.;
Raselli, G. L.;
Roncadelli, M.;
Rossella, M.;
Rubbia, C.;
Santorelli, R.;
Vignoli, C.
Submitted: 2004-05-18
The WARP programme is a graded programme intended to search for cold Dark
Matter in the form of WIMP's. These particles may produce via weak interactions
nuclear recoils in the energy range 10-100 keV. A cryogenic noble liquid like
argon, already used in the realization of very large detector, permits the
simultaneous detection of both ionisation and scintillation induced by an
interaction, suggesting the possibility of discriminating between nuclear
recoils and electrons mediated events. A 2.3 litres two-phase argon detector
prototype has been used to perform several tests on the proposed technique.
Next step is the construction of a 100 litres sensitive volume device with
potential sensitivity a factor 100 better than presently existing experiments.