Normalized to: Rapidis, N.
[1]
oai:arXiv.org:2003.08510 [pdf] - 2124673
An improved analysis framework for axion dark matter searches
Palken, D. A.;
Brubaker, B. M.;
Malnou, M.;
Kenany, S. Al;
Backes, K. M.;
Cahn, S. B.;
Gurevich, Y. V.;
Lamoreaux, S. K.;
Lewis, S. M.;
Maruyama, R. H.;
Rapidis, N. M.;
Root, J. R.;
Simanovskaia, M.;
Shokair, T. M.;
Singh, Sukhman;
Speller, D. H.;
Urdinaran, I.;
van Bibber, K.;
Zhong, L.;
Lehnert, K. W.
Submitted: 2020-03-18, last modified: 2020-06-13
In experiments searching for axionic dark matter, the use of the standard
threshold-based data analysis discards valuable information. We present a
Bayesian analysis framework that builds on an existing processing protocol to
extract more information from the data of coherent axion detectors such as
operating haloscopes. The analysis avoids logical subtleties that accompany the
standard analysis framework and enables greater experimental flexibility on
future data runs. Performing this analysis on the existing data from the
HAYSTAC experiment, we find improved constraints on the axion-photon coupling
$g_\gamma$ while also identifying the most promising regions of parameter space
within the $23.15$--$24.0$ $\mu$eV mass range. A comparison with the standard
threshold analysis suggests a $36\%$ improvement in scan rate from our
analysis, demonstrating the utility of this framework for future axion
haloscope analyses.
[2]
oai:arXiv.org:2005.03700 [pdf] - 2091791
Resonant Conversion of Dark Matter Oscillons in Pulsar Magnetospheres
Submitted: 2020-05-07
Due to their high magnetic fields and plasma densities, pulsars provide
excellent laboratories for tests of beyond Standard Model (BSM) physics. When
axions or axion-like particles (ALPs) approach closely enough to pulsars, they
can be resonantly converted to photons, yielding dramatic electromagnetic
signals. We discuss the possibility of detecting such signals from bound
configurations of axions, colliding with pulsar magnetospheres. We find that
all but the densest axion stars, $\textit{oscillons}$, are tidally destroyed
well before resonant conversion can take place. Oscillons can be efficiently
converted to photons, leading to bright, ephemeral radio flashes. Observation
of the galactic bulge using existing (Very Large Array and LOFAR) and
forthcoming (Square Kilometer Array) radio missions has the potential to detect
such events for axion masses in the range $m_a \in \left[0.1 \ \mu\text{eV},
200 \ \mu\text{eV}\right]$, even if oscillons make up a negligible fraction of
dark matter.
[3]
oai:arXiv.org:1708.04276 [pdf] - 1723415
Application of the Bead Perturbation Technique to a Study of a Tunable 5
GHz Annular Cavity
Submitted: 2017-08-14
Microwave cavities for a Sikivie-type axion search are subject to several
constraints. In the fabrication and operation of such cavities, often used at
frequencies where the resonator is highly overmoded, it is important to be able
to reliably identify several properties of the cavity. Those include
identifying the symmetry of the mode of interest, confirming its form factor,
and determining the frequency ranges where mode crossings with intruder levels
cause unacceptable admixture, thus leading to the loss of purity of the mode of
interest. A simple and powerful diagnostic for mapping out the electric field
of a cavity is the bead perturbation technique. While a standard tool in
accelerator physics, we have, for the first time, applied this technique to
cavities used in the axion search. We report initial results from an extensive
study for the initial cavity used in the HAYSTAC experiment. Two effects have
been investigated: the role of rod misalignment in mode localization, and
mode-mixing at avoided crossings of TM/TE modes. Future work will extend these
results by incorporating precision metrology and high-fidelity simulations.
[4]
oai:arXiv.org:1611.07123 [pdf] - 1537416
Design and Operational Experience of a Microwave Cavity Axion Detector
for the 20-100 micro-eV Range
Kenany, S. Al;
Anil, M. A.;
Backes, K. M.;
Brubaker, B. M.;
Cahn, S. B.;
Carosi, G.;
Gurevich, Y. V.;
Kindel, W. F.;
Lamoreaux, S. K.;
Lehnert, K. W.;
Lewis, S. M.;
Malnou, M.;
Palken, D. A.;
Rapidis, N. M.;
Root, J. R.;
Simanovskaia, M.;
Shokair, T. M.;
Urdinaran, I.;
van Bibber, K. A.;
Zhong, L.
Submitted: 2016-11-21, last modified: 2017-02-22
We describe a dark matter axion detector designed, constructed, and operated
both as an innovation platform for new cavity and amplifier technologies and as
a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: \mu$eV). The
platform is small but flexible to facilitate the development of new microwave
cavity and amplifier concepts in an operational environment. The experiment has
recently completed its first data production; it is the first microwave cavity
axion search to deploy a Josephson parametric amplifier and a dilution
refrigerator to achieve near-quantum limited performance.
[5]
oai:arXiv.org:1610.02580 [pdf] - 1531959
First results from a microwave cavity axion search at 24 micro-eV
Brubaker, B. M.;
Zhong, L.;
Gurevich, Y. V.;
Cahn, S. B.;
Lamoreaux, S. K.;
Simanovskaia, M.;
Root, J. R.;
Lewis, S. M.;
Kenany, S. Al;
Backes, K. M.;
Urdinaran, I.;
Rapidis, N. M.;
Shokair, T. M.;
van Bibber, K. A.;
Palken, D. A.;
Malnou, M.;
Kindel, W. F.;
Anil, M. A.;
Lehnert, K. W.;
Carosi, G.
Submitted: 2016-10-08, last modified: 2017-02-09
We report on the first results from a new microwave cavity search for dark
matter axions with masses above $20~\mu\text{eV}$. We exclude axion models with
two-photon coupling $g_{a\gamma\gamma} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$
over the range $23.55~\mu\text{eV} < m_a < 24.0~\mu\text{eV}$. These results
represent two important achievements. First, we have reached cosmologically
relevant sensitivity an order of magnitude higher in mass than any existing
limits. Second, by incorporating a dilution refrigerator and Josephson
parametric amplifier, we have demonstrated total noise approaching the standard
quantum limit for the first time in an axion search.