sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Rapidis, N. M.

Normalized to: Rapidis, N.

5 article(s) in total. 23 co-authors, from 1 to 3 common article(s). Median position in authors list is 11,0.

[1]  oai:arXiv.org:2003.08510  [pdf] - 2124673
An improved analysis framework for axion dark matter searches
Comments: 22 pages, 5 figures
Submitted: 2020-03-18, last modified: 2020-06-13
In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis framework and enables greater experimental flexibility on future data runs. Performing this analysis on the existing data from the HAYSTAC experiment, we find improved constraints on the axion-photon coupling $g_\gamma$ while also identifying the most promising regions of parameter space within the $23.15$--$24.0$ $\mu$eV mass range. A comparison with the standard threshold analysis suggests a $36\%$ improvement in scan rate from our analysis, demonstrating the utility of this framework for future axion haloscope analyses.
[2]  oai:arXiv.org:2005.03700  [pdf] - 2091791
Resonant Conversion of Dark Matter Oscillons in Pulsar Magnetospheres
Comments: 20 pages, 2 figures
Submitted: 2020-05-07
Due to their high magnetic fields and plasma densities, pulsars provide excellent laboratories for tests of beyond Standard Model (BSM) physics. When axions or axion-like particles (ALPs) approach closely enough to pulsars, they can be resonantly converted to photons, yielding dramatic electromagnetic signals. We discuss the possibility of detecting such signals from bound configurations of axions, colliding with pulsar magnetospheres. We find that all but the densest axion stars, $\textit{oscillons}$, are tidally destroyed well before resonant conversion can take place. Oscillons can be efficiently converted to photons, leading to bright, ephemeral radio flashes. Observation of the galactic bulge using existing (Very Large Array and LOFAR) and forthcoming (Square Kilometer Array) radio missions has the potential to detect such events for axion masses in the range $m_a \in \left[0.1 \ \mu\text{eV}, 200 \ \mu\text{eV}\right]$, even if oscillons make up a negligible fraction of dark matter.
[3]  oai:arXiv.org:1708.04276  [pdf] - 1723415
Application of the Bead Perturbation Technique to a Study of a Tunable 5 GHz Annular Cavity
Comments: 6 pages, 4 figures, submitted to the 2nd Workshop on Microwave Cavities and Detectors for Axion Research
Submitted: 2017-08-14
Microwave cavities for a Sikivie-type axion search are subject to several constraints. In the fabrication and operation of such cavities, often used at frequencies where the resonator is highly overmoded, it is important to be able to reliably identify several properties of the cavity. Those include identifying the symmetry of the mode of interest, confirming its form factor, and determining the frequency ranges where mode crossings with intruder levels cause unacceptable admixture, thus leading to the loss of purity of the mode of interest. A simple and powerful diagnostic for mapping out the electric field of a cavity is the bead perturbation technique. While a standard tool in accelerator physics, we have, for the first time, applied this technique to cavities used in the axion search. We report initial results from an extensive study for the initial cavity used in the HAYSTAC experiment. Two effects have been investigated: the role of rod misalignment in mode localization, and mode-mixing at avoided crossings of TM/TE modes. Future work will extend these results by incorporating precision metrology and high-fidelity simulations.
[4]  oai:arXiv.org:1611.07123  [pdf] - 1537416
Design and Operational Experience of a Microwave Cavity Axion Detector for the 20-100 micro-eV Range
Comments: 17 pages, published in NIM A. v2: added changes made during the review process
Submitted: 2016-11-21, last modified: 2017-02-22
We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: \mu$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently completed its first data production; it is the first microwave cavity axion search to deploy a Josephson parametric amplifier and a dilution refrigerator to achieve near-quantum limited performance.
[5]  oai:arXiv.org:1610.02580  [pdf] - 1531959
First results from a microwave cavity axion search at 24 micro-eV
Comments: 5 pages, 3 figures, accepted for publication in PRL. v2: added changes made during the review process
Submitted: 2016-10-08, last modified: 2017-02-09
We report on the first results from a new microwave cavity search for dark matter axions with masses above $20~\mu\text{eV}$. We exclude axion models with two-photon coupling $g_{a\gamma\gamma} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$ over the range $23.55~\mu\text{eV} < m_a < 24.0~\mu\text{eV}$. These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an order of magnitude higher in mass than any existing limits. Second, by incorporating a dilution refrigerator and Josephson parametric amplifier, we have demonstrated total noise approaching the standard quantum limit for the first time in an axion search.