sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Ramberg, E.

Normalized to: Ramberg, E.

11 article(s) in total. 168 co-authors, from 1 to 9 common article(s). Median position in authors list is 18,0.

[1]  oai:arXiv.org:1510.07754  [pdf] - 1382070
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Comments: v3 to reflect published version
Submitted: 2015-10-26, last modified: 2016-03-03
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. These behaviors allow for analysis cuts to remove all background events while retaining $48.2\%$ of the exposure. Stringent limits on weakly interacting massive particles interacting via spin-dependent proton and spin-independent processes are set, and most interpretations of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei are ruled out.
[2]  oai:arXiv.org:1304.6001  [pdf] - 778562
Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I Bubble Chamber
Comments: 5 pages, 3 figures
Submitted: 2013-04-22, last modified: 2014-01-31
We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel telescope and the reconstructed scattering angle provides a measure of the nuclear recoil kinetic energy. The bubble chamber was operated with a nominal threshold of (13.6+-0.6) keV. Interpretation of the results depends on the response to fluorine and carbon recoils, but in general we find agreement with the predictions of the classical bubble nucleation theory. This measurement confirms the applicability of CF3I as a target for spin-independent dark matter interactions and represents a novel technique for calibration of superheated fluid detectors.
[3]  oai:arXiv.org:1204.3094  [pdf] - 565655
First dark matter search results from a 4-kg CF$_3$I bubble chamber operated in a deep underground site
Comments: 9 pages, 7 figures, 2 tables
Submitted: 2012-04-13, last modified: 2012-09-19
New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of ultrasound analysis in discriminating alpha-decay background events from single nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of alpha-decay events. Twenty single nuclear recoil event candidates and three multiple bubble events were observed during a total exposure of 553 kg-days distributed over three different bubble nucleation thresholds. The effective exposure for single bubble recoil-like events was 437.4 kg-days. A neutron background internal to the apparatus, of known origin, is estimated to account for five single nuclear recoil events and is consistent with the observed rate of multiple bubble events. This observation provides world best direct detection constraints on WIMP-proton spin-dependent scattering for WIMP masses $>$20 GeV/c$^{2}$ and demonstrates significant sensitivity for spin-independent interactions.
[4]  oai:arXiv.org:1012.5078  [pdf] - 371990
Search for inelastic dark matter with the CDMS II experiment
Comments: 10 pages, 10 figures, minor changes to match published version, conclusion unchanged
Submitted: 2010-12-22, last modified: 2011-06-12
Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the inelastic dark matter (iDM) model. Three dark matter candidates were found between 25 keV and 150 keV. The probability to observe three or more background events in this energy range is 11%. Because of the occurrence of these events the constraints on the iDM parameter space are slightly less stringent than those from our previous analysis, which used an energy window of 10-100 keV.
[5]  oai:arXiv.org:1011.2482  [pdf] - 347805
Results from a Low-Energy Analysis of the CDMS II Germanium Data
Comments: 9 pages, 8 figures. Supplemental material included as ancillary files. v3) Added appendix with additional details regarding energy scale and backgrounds
Submitted: 2010-11-10, last modified: 2011-04-21
We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below ~10 GeV/c^2. This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.
[6]  oai:arXiv.org:1008.3518  [pdf] - 326586
Improved Limits on Spin-Dependent WIMP-Proton Interactions from a Two Liter CF$_3$I Bubble Chamber
Comments: 4 pages, 4 figures V2 submitted to match journal version
Submitted: 2010-08-20, last modified: 2011-03-07
Data from the operation of a bubble chamber filled with 3.5 kg of CF$_{3}$I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during an effective exposure of 28.1 kg-day, consistent with a neutron background. This observation provides the strongest direct detection constraint to date on WIMP-proton spin-dependent scattering for WIMP masses $>20$ GeV/c$^{2}$.
[7]  oai:arXiv.org:0907.1438  [pdf] - 142195
Analysis of the low-energy electron-recoil spectrum of the CDMS experiment
Comments: 4 pages, 3 figures
Submitted: 2009-07-09
We report on the analysis of the low-energy electron-recoil spectrum from the CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis provides details on the observed counting rate and possible background sources in the energy range of 2 - 8.5 keV. We find no significant excess in the counting rate above background, and compare this observation to the recent DAMA results. In the framework of a conversion of a dark matter particle into electromagnetic energy, our 90% confidence level upper limit of 0.246 events/kg/day at 3.15 keV is lower than the total rate above background observed by DAMA by 8.9$\sigma$. In absence of any specific particle physics model to provide the scaling in cross section between NaI and Ge, we assume a Z^2 scaling. With this assumption the observed rate in DAMA differs from the upper limit in CDMS by 6.8$\sigma$. Under the conservative assumption that the modulation amplitude is 6% of the total rate we obtain upper limits on the modulation amplitude a factor of ~2 less than observed by DAMA, constraining some possible interpretations of this modulation.
[8]  oai:arXiv.org:0904.3565  [pdf] - 23601
The Next Generation of Photo-Detectors for Particle Astrophysics
Comments: Astro2010 Technology Development White Paper; 11 pages, 3 figures
Submitted: 2009-04-22
We advocate support of research aimed at developing alternatives to the photomultiplier tube for photon detection in large astroparticle experiments such as gamma-ray and neutrino astronomy, and direct dark matter detectors. Specifically, we discuss the development of large area photocathode microchannel plate photomultipliers and silicon photomultipliers. Both technologies have the potential to exhibit improved photon detection efficiency compared to existing glass vacuum photomultiplier tubes.
[9]  oai:arXiv.org:0804.2886  [pdf] - 11873
Improved Spin-Dependent WIMP Limits from a Bubble Chamber
Comments: This is the author's version of the work. It is posted here by permission of the AAAS for personal use, not for redistribution. The definitive version was published in Science 319, 15 February 2008, doi:10.1126/science.1149999
Submitted: 2008-04-17
Bubble Chambers provided the dominant particle detection technology in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on the first period of operation of an ultra-clean, room-temperature bubble chamber containing 1.5 kg of superheated CF$_{3}$I, a target maximally sensitive to spin-dependent and -independent Weakly Interacting Massive Particle (WIMP) couplings. An exposure in excess of 250 kg-days is obtained, with a live-time fraction reaching 80%. This illustrates the ability to employ bubble chambers in a new realm, the search for dark matter particles. Improved limits on the spin-dependent WIMP-proton scattering cross section are extracted from this first period. An extreme intrinsic insensitivity to the backgrounds commonly limiting these experiments (a rejection factor for photon-induced electrons of $\sim10^{-10}$) has been measured in operating conditions leading to the detection of low-energy nuclear recoils such as those expected from WIMPs.
[10]  oai:arXiv.org:astro-ph/0503583  [pdf] - 880834
Beyond the CDMS-II Dark Matter Search: SuperCDMS
Comments: Submitted to Texas Symposium on Relativistic Astrophysics held at Stanford, Dec. 2004. Paper has 6 pages, 4 figures
Submitted: 2005-03-27
Presently the CDMS-II collaboration's Weakly Interacting Massive Particle (WIMP) search at the Soudan Underground Laboratory sets the most stringent exclusion limits of any WIMP cold dark matter direct-detection experiment. To extend our reach further, to WIMP-nucleon cross sections in the range $10^{-46} - 10^{-44}$cm$^2$, we propose SuperCDMS, which would take advantage of a very deep site. One promising site is the recently approved SNOLab facility in Canada. In this paper we will present our overall plan, identify primary issues, and set the goals that need to be met prior to embarking upon each phase of SuperCDMS.
[11]  oai:arXiv.org:astro-ph/0503398  [pdf] - 358287
Development of Bubble Chambers With Enhanced Stability and Sensitivity to Low-Energy Nuclear Recoils
Comments: 4 pages, 3 figures. Submitted to Phys. Rev. Lett
Submitted: 2005-03-17
The viability of using a Bubble Chamber for rare event searches and in particular for the detection of dark matter particle candidates is considered. Techniques leading to the deactivation of inhomogeneous nucleation centers and subsequent enhanced stability in such a detector are described. Results from prototype trials indicate that sensitivity to low-energy nuclear recoils like those expected from Weakly Interacting Massive Particles can be obtained in conditions of near total insensitivity to minimum ionizing backgrounds. An understanding of the response of superheated heavy refrigerants to these recoils is demonstrated within the context of existing theoretical models. We comment on the prospects for the detection of supersymmetric dark matter particles with a large $CF_{3}I$ chamber.