Normalized to: Raley, M.
[1]
oai:arXiv.org:astro-ph/0209161 [pdf] - 51567
The Flight Spectral Response of the ACIS Instrument
Plucinsky, Paul P.;
Schulz, Norbert S.;
Marshall, Herman L.;
Grant, Catherine E.;
Chartas, George;
Sanwal, Divas;
Teter, Marcus A.;
Vikhlinin, Alexey A.;
Edgar, Richard J.;
Wise, Michael W.;
Allen, Glenn E.;
Virani, Shanil N.;
DePasquale, Joseph M.;
Raley, Michael T.
Submitted: 2002-09-09, last modified: 2002-09-24
We discuss the flight calibration of the spectral response of the Advanced
CCD Imaging Spectrometer (ACIS) on-board the Chandra X-ray Observatory (CXO).
The spectral resolution and sensitivity of the ACIS instrument have both been
evolving over the course of the mission. The spectral resolution of the
frontside-illuminated (FI) CCDs changed dramatically in the first month of the
mission due to radiation damage. Since that time, the spectral resolution of
the FI CCDs and the backside-illuminated (BI) CCDs have evolved gradually with
time. We demonstrate the efficacy of charge-transfer inefficiency (CTI)
correction algorithms which recover some of the lost performance. The detection
efficiency of the ACIS instrument has been declining throughout the mission,
presumably due to a layer of contamination building up on the filter and/or
CCDs. We present a characterization of the energy dependence of the excess
absorption and demonstrate software which models the time dependence of the
absorption from energies of 0.4 keV and up. The spectral redistribution
function and the detection efficiency are well-characterized at energies from
1.5 to 8.0 keV. The calibration at energies below 1.5 keV is challenging
because of the lack of strong lines in the calibration source and also because
of the inherent non-linear dependence with energy of the CTI and the absorption
by the contamination layer. We have been using data from celestial sources with
relatively simple spectra to determine the quality of the calibration below 1.5
keV. The analysis of these observations demonstrate that the CTI correction
recovers a significant fraction of the spectral resolution of the FI CCDs and
the models of the time-dependent absorption result in consistent measurements
of the flux at low energies for data from a BI (S3) CCD.
[2]
oai:arXiv.org:astro-ph/0203190 [pdf] - 48211
A Mini-survey of X-ray Point Sources in Starburst and Non-Starburst
Galaxies
Submitted: 2002-03-12
We present a comparison of X-ray point source luminosity functions of 3
starburst galaxies (the Antennae, M82, and NGC 253) and 4 non-starburst spiral
galaxies (NGC 3184, NGC 1291, M83, and IC 5332). We find that the luminosity
functions of the starbursts are flatter than those of the spiral galaxies; the
starbursts have relatively more sources at high luminosities. This trend
extends to early-type galaxies which have steeper luminosity functions than
spirals. We show that the luminosity function slope is correlated with 60
micron luminosity, a measure of star formation. We suggest that the difference
in luminosity functions is related to the age of the X-ray binary populations
and present a simple model which highlights how the shape of the luminosity
distribution is affected by the age of the underlying X-ray binary population.