Normalized to: Rafferty, T.
[1]
oai:arXiv.org:1605.09780 [pdf] - 1415310
W1J00 and W2J00: Results of the Observations made with the Six-inch
Transit Circle 1977-1982 AND Results of Pole-to-Pole Observations made with
the Six-inch and Seven-inch Transit Circles 1985-1996
Submitted: 2016-05-31
The astronomical results contained in this publication represent a
continuation of previous work of the United States Naval Observatory Six-inch
and Seven-inch transit circles. The results are also the last from United
States Naval Observatory transit circles, since those instruments are no longer
in service.
For the W1J00, we present the results of observations made with the Six-inch
Transit Circle in Washington, D.C., between September 1977 and July 1982. The
catalog, called W1J00, contains mean positions of 7267 stars, all but five are
north of -30 degrees declination, and 4383 observations of solar system
objects. Positions of stars are for mean epoch of observation, on equator and
equinox J2000.0. Positions of solar system objects are apparent places. Error
estimates are about 100 mas per coordinate for the majority of stars.
For the W2J00, we present the results of observations made with the Six-inch
Transit Circle in Washington, D.C. and the Seven-inch Transit Circle at the
Black Birch station near Blenheim, New Zealand between April 1985 and February
1996. The catalog, called W2J00, contains mean positions of 44,395 globally
distributed stars, 5048 observations of the planets, and 6518 observations of
the brighter minor planets. Positions of stars are for mean epoch of
observation, on equator and equinox J2000.0. Positions of solar system objects
are apparent places. Error estimates are about 75 mas per coordinate for the
majority of stars.
[2]
oai:arXiv.org:1508.04637 [pdf] - 1277193
The First U.S. Naval Observatory Robotic Astrometric Telescope Catalog
(URAT1)
Zacharias, Norbert;
Finch, Charlie;
Subasavage, John;
Bredthauer, Greg;
Crockett, Chris;
DiVittorio, Mike;
Ferguson, Erik;
Harris, Fred;
Harris, Hugh;
Henden, Arne;
Kilian, Chris;
Munn, Jeff;
Rafferty, Ted;
Rhodes, Al;
Schultheiss, Mike;
Tilleman, Trudy;
Wieder, Gary
Submitted: 2015-08-19
URAT1 is an observational, astrometric catalog covering most of the Dec >=
-15 deg area and a magnitude range of about R = 3 to 18.5. Accurate positions
(typically 10 to 30 mas standard error) are given for over 228 million objects
at a mean epoch around 2013.5. For the over 188 million objects matched with
the 2MASS point source catalog proper motions (typically 5 to 7 mas/yr std.
errors) are provided. These data are supplemented by 2MASS and APASS
photometry. Observations, reductions and catalog construction are described
together with results from external data verifications. The catalog data are
served by CDS, Starsbourg (I/329). There is no DVD release.
[3]
oai:arXiv.org:1305.0309 [pdf] - 659091
The Influence of Motion and Stress on Optical Fibers
Murphy, Jeremy D.;
Hill, Gary J.;
MacQueen, Phillip J.;
Taylor, Trey;
Soukup, Ian;
Moreira, Walter;
Cornell, Mark E.;
Good, John;
Anderson, Seth;
Fuller, Lindsay;
Lee, Hanshin;
Kelz, Andreas;
Rafal, Marc;
Rafferty, Tom;
Tuttle, Sarah;
Vattiat, Brian
Submitted: 2013-05-01
We report on extensive testing carried out on the optical fibers for the
VIRUS instrument. The primary result of this work explores how 10+ years of
simulated wear on a VIRUS fiber bundle affects both transmission and focal
ratio degradation (FRD) of the optical fibers. During the accelerated lifetime
tests we continuously monitored the fibers for signs of FRD. We find that
transient FRD events were common during the portions of the tests when motion
was at telescope slew rates, but dropped to negligible levels during rates of
motion typical for science observation. Tests of fiber transmission and FRD
conducted both before and after the lifetime tests reveal that while
transmission values do not change over the 10+ years of simulated wear, a clear
increase in FRD is seen in all 18 fibers tested. This increase in FRD is likely
due to microfractures that develop over time from repeated flexure of the fiber
bundle, and stands in contrast to the transient FRD events that stem from
localized stress and subsequent modal diffusion of light within the fibers.
There was no measurable wavelength dependence on the increase in FRD over 350
nm to 600 nm. We also report on bend radius tests conducted on individual
fibers and find the 266 microns VIRUS fibers to be immune to bending-induced
FRD at bend radii of R > 10cm. Below this bend radius FRD increases slightly
with decreasing radius. Lastly, we give details of a degradation seen in the
fiber bundle currently deployed on the Mitchell Spectrograph (formally VIRUS-P)
at McDonald Observatory. The degradation is shown to be caused by a localized
shear in a select number of optical fibers that leads to an explosive form of
FRD. In a few fibers, the overall transmission loss through the instrument can
exceed 80%.
[4]
oai:arXiv.org:1003.2136 [pdf] - 1025634
The Third US Naval Observatory CCD Astrograph Catalog (UCAC3)
Zacharias, N.;
Finch, C.;
Girard, T.;
Hambly, N.;
Wycoff, G.;
Zacharias, M.;
Castillo, D.;
Corbin, T.;
DiVittorio, M.;
Dutta, S.;
Gaume, R.;
Gauss, S.;
Germain, M.;
Hall, D.;
Hartkopf, W.;
Hsu, D.;
Holdenried, E.;
Makarov, V.;
Martines, M.;
Mason, B.;
Monet, D.;
Rafferty, T.;
Rhodes, A.;
Siemers, T.;
Smith, D.;
Tilleman, T.;
Urban, S.;
Wieder, G.;
Winter, L.;
Young, A.
Submitted: 2010-03-09
The third US Naval Observatory (USNO) CCD Astrograph Catalog, UCAC3 was
released at the IAU General Assembly on 2009 August 10. It is the first all-sky
release in this series and contains just over 100 million objects, about 95
million of them with proper motions, covering about R = 8 to 16 magnitudes.
Current epoch positions are obtained from the observations with the 20 cm
aperture USNO Astrograph's "red lens", equipped with a 4k by 4k CCD. Proper
motions are derived by combining these observations with over 140 ground- and
space-based catalogs, including Hipparcos/Tycho and the AC2000.2, as well as
unpublished measures of over 5000 plates from other astrographs. For most of
the faint stars in the Southern Hemisphere the Yale/San Juan first epoch plates
from the SPM program (YSJ1) form the basis for proper motions. These data are
supplemented by all-sky Schmidt plate survey astrometry and photometry obtained
from the SuperCOSMOS project, as well as 2MASS near-IR photometry. Major
differences of UCAC3 data as compared to UCAC2 include a completely new raw
data reduction with improved control over systematic errors in positions,
significantly improved photometry, slightly deeper limiting magnitude, coverage
of the north pole region, greater completeness by inclusion of double stars and
weak detections. This of course leads to a catalog which is not as "clean" as
UCAC2 and problem areas are outlined for the user in this paper. The positional
accuracy of stars in UCAC3 is about 15 to 100 mas per coordinate, depending on
magnitude, while the errors in proper motions range from 1 to 10 mas/yr
depending on magnitude and observing history, with a significant improvement
over UCAC2 achieved due to the re-reduced SPM data and inclusion of more
astrograph plate data unavailable at the time of UCAC2.
[5]
oai:arXiv.org:0806.0256 [pdf] - 13141
The StarScan plate measuring machine: overview and calibrations
Submitted: 2008-06-02
The StarScan machine at the U.S. Naval Observatory (USNO) completed measuring
photographic astrograph plates to allow determination of proper motions for the
USNO CCD Astrograph Catalog (UCAC) program. All applicable 1940 AGK2 plates,
about 2200 Hamburg Zone Astrograph plates, 900 Black Birch (USNO Twin
Astrograph) plates, and 300 Lick Astrograph plates have been measured. StarScan
comprises of a CCD camera, telecentric lens, air-bearing granite table, stepper
motor screws, and Heidenhain scales to operate in a step-stare mode. The
repeatability of StarScan measures is about 0.2 micrometer. The CCD mapping as
well as the global table coordinate system has been calibrated using a special
dot calibration plate and the overall accuracy of StarScan x,y data is derived
to be 0.5 micrometer. Application to real photographic plate data shows that
position information of at least 0.65 micrometer accuracy can be extracted from
course grain 103a-type emulsion astrometric plates. Transformations between
"direct" and "reverse" measures of fine grain emulsion plate measures are
obtained on the 0.3 micrometer level per well exposed stellar image and
coordinate, which is at the limit of the StarScan machine.
[6]
oai:arXiv.org:astro-ph/0403060 [pdf] - 63251
The second US Naval Observatory CCD Astrograph Catalog (UCAC2)
Submitted: 2004-03-02
The second USNO CCD Astrograph Catalog, UCAC2 was released in July 2003.
Positions and proper motions for 48,330,571 sources (mostly stars) are
available on 3 CDs, supplemented with 2MASS photometry for 99.5% of the
sources. The catalog covers the sky area from -90 to +40 degrees declination,
going up to +52 in some areas; this completely supersedes the UCAC1 released in
2001. Current epoch positions are obtained from observations with the USNO
8-inch Twin Astrograph equipped with a 4k CCD camera. The precision of the
positions are 15 to 70 mas, depending on magnitude, with estimated systematic
errors of 10 mas or below. Proper motions are derived by utilizing over 140
ground-and space-based catalogs, including Hipparcos/Tycho, the AC2000.2, as
well as yet unpublished re-measures of the AGK2 plates and scans from the NPM
and SPM plates. Proper motion errors are about 1 to 3 mas/yr for stars to 12th
magnitude, and about 4 to 7 mas/yr for fainter stars to 16th magnitude. The
observational data, astrometric reductions, results, and important information
for the users of this catalog are presented.