Normalized to: Rabin, D.
[1]
oai:arXiv.org:1109.6598 [pdf] - 967079
Underflight calibration of SOHO/CDS and Hinode/EIS with EUNIS-07
Submitted: 2011-09-29
Flights of Goddard Space Flight Center's Extreme-Ultraviolet Normal-Incidence
Spectrograph (EUNIS) sounding rocket in 2006 and 2007 provided updated
radiometric calibrations for SOHO/CDS and Hinode/EIS. EUNIS carried two
independent imaging spectrographs covering wavebands of 300-370 A in first
order and 170-205 A in second order. After each flight, end-to-end radiometric
calibrations of the rocket payload were carried out in the same facility used
for pre-launch calibrations of CDS and EIS. During the 2007 flight, EUNIS, SOHO
CDS and Hinode EIS observed the same solar locations, allowing the EUNIS
calibrations to be directly applied to both CDS and EIS. The measured CDS NIS 1
line intensities calibrated with the standard (version 4) responsivities with
the standard long-term corrections are found to be too low by a factor of 1.5
due to the decrease in responsivity. The EIS calibration update is performed in
two ways. One is using the direct calibration transfer of the calibrated
EUNIS-07 short wavelength (SW) channel. The other is using the insensitive line
pairs, in which one member was observed by EUNIS-07 long wavelength (LW)
channel and the other by EIS in either LW or SW waveband. Measurements from
both methods are in good agreement, and confirm (within the measurement
uncertainties) the EIS responsivity measured directly before the instrument's
launch. The measurements also suggest that the EIS responsivity decreased by a
factor of about 1.2 after the first year of operation. The shape of the EIS SW
response curve obtained by EUNIS-07 is consistent with the one measured in
laboratory prior to launch. The absolute value of the quiet-Sun He II 304 A
intensity measured by EUNIS-07 is consistent with the radiance measured by CDS
NIS in quiet regions near the disk center and the solar minimum irradiance
obtained by CDS NIS and SDO/EVE recently.
[2]
oai:arXiv.org:1011.4052 [pdf] - 264469
Science Objectives for an X-Ray Microcalorimeter Observing the Sun
Laming, J. Martin;
Adams, J.;
Alexander, D.;
Aschwanden, M;
Bailey, C.;
Bandler, S.;
Bookbinder, J.;
Bradshaw, S.;
Brickhouse, N.;
Chervenak, J.;
Christe, S.;
Cirtain, J.;
Cranmer, S.;
Deiker, S.;
DeLuca, E.;
Del Zanna, G.;
Dennis, B.;
Doschek, G.;
Eckart, M.;
Fludra, A.;
Finkbeiner, F.;
Grigis, P.;
Harrison, R.;
Ji, L.;
Kankelborg, C.;
Kashyap, V.;
Kelly, D.;
Kelley, R.;
Kilbourne, C.;
Klimchuk, J.;
Ko, Y. -K.;
Landi, E.;
Linton, M.;
Longcope, D.;
Lukin, V.;
Mariska, J.;
Martinez-Galarce, D.;
Mason, H.;
McKenzie, D.;
Osten, R.;
Peres, G.;
Pevtsov, A.;
Porter, K. Phillips F. S.;
Rabin, D.;
Rakowski, C.;
Raymond, J.;
Reale, F.;
Reeves, K.;
Sadleir, J.;
Savin, D.;
Schmelz, J.;
Smith, R. K.;
Smith, S.;
Stern, R.;
Sylwester, J.;
Tripathi, D.;
Ugarte-Urra, I.;
Young, P.;
Warren, H.;
Wood, B.
Submitted: 2010-11-17
We present the science case for a broadband X-ray imager with high-resolution
spectroscopy, including simulations of X-ray spectral diagnostics of both
active regions and solar flares. This is part of a trilogy of white papers
discussing science, instrument (Bandler et al. 2010), and missions (Bookbinder
et al. 2010) to exploit major advances recently made in transition-edge sensor
(TES) detector technology that enable resolution better than 2 eV in an array
that can handle high count rates. Combined with a modest X-ray mirror, this
instrument would combine arcsecondscale imaging with high-resolution spectra
over a field of view sufficiently large for the study of active regions and
flares, enabling a wide range of studies such as the detection of microheating
in active regions, ion-resolved velocity flows, and the presence of non-thermal
electrons in hot plasmas. It would also enable more direct comparisons between
solar and stellar soft X-ray spectra, a waveband in which (unusually) we
currently have much better stellar data than we do of the Sun.
[3]
oai:arXiv.org:0912.2328 [pdf] - 260256
Absolute radiometric calibration of the EUNIS-06 170-205 A channel and
calibration update for CDS/NIS
Submitted: 2009-12-11
The Extreme-Ultraviolet Normal-Incidence Spectrograph sounding-rocket payload
was flown on 2006 April 12 (EUNIS-06), carrying two independent imaging
spectrographs covering wave bands of 300-370 A in first order and 170-205 A in
second order, respectively. The absolute radiometric response of the EUNIS-06
long-wavelength (LW) channel was directly measured in the same facility used to
calibrate CDS prior to the SOHO launch. Because the absolute calibration of the
short-wavelength (SW) channel could not be obtained from the same lab
configuration, we here present a technique to derive it using a combination of
solar LW spectra and density- and temperature-insensitive line intensity
ratios. The first step in this procedure is to use the coordinated, cospatial
EUNIS and SOHO/CDS spectra to carry out an intensity calibration update for the
CDS NIS-1 waveband, which shows that its efficiency has decreased by a factor
about 1.7 compared to that of the previously implemented calibration. Then,
theoretical insensitive line ratios obtained from CHIANTI allow us to determine
absolute intensities of emission lines within the EUNIS SW bandpass from those
of cospatial CDS/NIS-1 spectra after the EUNIS LW calibration correction. A
total of 12 ratios derived from intensities of 5 CDS and 12 SW emission lines
from Fe Fe X - Fe XIII yield an instrumental response curve for the EUNIS-06 SW
channel that matches well to a relative calibration which relied on combining
measurements of individual optical components. Taking into account all
potential sources of error, we estimate that the EUNIS-06 SW absolute
calibration is accurate to about 20%.
[4]
oai:arXiv.org:0804.1629 [pdf] - 11650
Transition-Region Velocity Oscillations Observed by EUNIS-06
Submitted: 2008-04-10
Spectroscopic measurements of AR NOAA 10871, obtained with the Extreme
Ultraviolet Normal Incidence Spectrograph (EUNIS) sounding rocket instrument on
2006 April 12, reveal velocity oscillations in the He II 303.8 Angstrom
emission line formed at T ~ 50000K. The oscillations appear to arise in a
bright active-region loop arcade about 25" wide which crosses the EUNIS slit.
The period of these transition region oscillations is 26 +/- 4 s, coupled with
a velocity amplitude of +/- 10 km/s, detected over 4 complete cycles. Similar
oscillations are observed in lines formed at temperatures up to T ~ 400000K,
but we find no evidence for the coupling of these velocity oscillations with
corresponding phenomena in the corona. We interpret the detected oscillations
as originating from an almost purely adiabatic plasma, and infer that they are
generated by the resonant transmission of MHD waves through the lower
active-region atmospheres. Through use of seismological techniques, we
establish that the observed velocity oscillations display wave properties most
characteristic of fast-body global sausage modes.